Project Name: WYNSTONE LOT 11
Project Address: 33831 12TH PL SW
4#uilding - Single`Family
Permit #: 11 -103843 -00 -SF
Inspection Request Line: (253) 835-3050
Parcel Number: 957814 0110
Project Description: NEW - Construction of 1,698 square foot 2 -story single family residence with a 147 square
foot covered entry and 400 square foot attached garage. Includes plumbing & mechanical.
***4 Bedrooms; Estimated selling price $260,000***
Owner
Aaalicant
Contractor
Lender
QUADRANT CORPORATION
QUADRANT CORPORATION
QUADRANT CORPORATION
QUADRANT CORPORATION
14725 SE 36TH ST UNIT 200
PO BOX 130
QUADRC*221OF (9/10/13)
PO BOX 130
BELLEVUE WA
BELLEVUE WA 98009
PO BOX 130
BELLEVUE WA 98009
BELLEVUE WA 98009
Census Category: 101 - New Single Family House
Includes:
41
#2 43 #4
Occupancy Class:
R-3
R-3
Construction Type:
Type V- B
Type V- B
Occupancy Load:
Floor Area (sq. ft.) 1
1,845 1
400 0 0
si
Air Handling Units...C-4..
Furnaces ......... ................ .........
�
Hot Water Tank ... J ..... — a'..
..........y ..............
.,..,..................................
,Piping ...........................
Showers..........................................
Hose Bibbs.....................................
Fireplace Inserts .............................
Gas Pipe Outlets ............................
PERMIT EXPIRES Tuesday, April 10, 2012
Permit Issued on Thursday, October 13, 2011
hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and he City of Federal Way. j
Owner or agent: Date: t
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that
at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building
construction or use. This certificate is valid ONLY when endorsed by City staff -
Tenant Name: WYNSTONE LOT 11
Address: 33831 12TH PL SW
Permit #: 11 -103843 -00 -SF
Includes:
#1
#2 #3 #4
Occupancy Class:
R-3
R-3
Construction Type:
Type V- B
Type V- B
Occupancy Load:
Floor Area (sq. ft.) 1
1,845 1
400 0 0
Owner Name:
Owner Address:
Building
QUADRANT CORPORATION
14725 SE 36TH ST UNIT 200
BELLEVUE WA
Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most sevedy affect the health and safety of the general public. Although, the City has made as complete a
review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor
warrants to the owner/ occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which itis situated. Such compliance is the responsibility of the owner and / or occupant of the premises.
C" OF
Federal Way
PERMIT #:
Project:
THIS CARD IS TO MAIN ON-SITE
Construction I ection Record
INSPECTION REQUE TS: (253) 835-3050
11 -103842 -00 -SF Address: 1320 SW 340TH ST
QUADRANT CORPORATION FEDERAL WAY, WA 98023
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
rl SWM Precon Site Mtg (4400)
Initial Erosion Control (4365)
❑ Footings/Setback (4110)
Approved
To be done prior to breaking ground
Approved to place concrete
By Date
By Date
BS C Date
Foundation Wall (4115)
Approved to place concrete
By Date /_-9 -;?,o -/,/
Slab/Concrete Floor (4255)
Approved to place concrete
By Date
Shear Walls (4245)
Approved to install siding
B Date
Mechanical Rough -in (4165)
Approved
By Date 1 V" %q -•t ( .
rg Interim Erosion Control (4370)
Approved
By Date
Drainage/Downspout (4040)
Approved to backfill
By Date
Underfloor Framing (4285)
Approved to sheath floor
By Date
- 2
Roof Sheathing ,(4220)
Approved to install roofing
B Date(l=l�¢--l(
❑ Gas Piping (4125)
Approved to release test
By � � Date �J._'JA— A
Prior to scheduling a Framing inspection;
Electrical, Plumbing & Mechanical Rough -in and
Fire/Draft Stop inspections must be signed -off and
approved. IBC 109.3.4
Plumbing Groundwork (4190)
Approved to cover
By Date
Floor Sheathing (4105)
Approved to install flooring
B C_S Date C l
Rough Plumbing (4230)
Approved
By Q� J Date ,1_2 i
Fire/Draft Stops (4095)
Approved
B �(57S Date
El Framing (4120) _
Approved to insulate
By Date _
El Final - Mechanical (4065)
Approved
By Date
Final - Plumbing (4075)
Approved
By Date
FILE
Final - Building (4050)
Approved
Date t.—�r?
EJ
Insulation (4150)
Approved to install wallboard
❑ Gypsum Wallboard Nailing (4130)
Approved to install mud & tape
❑
Final Erosion Control (4375)
Approved
By
Date
.Z -
By
By -T Datel2-- (
By
Date
El Final - Mechanical (4065)
Approved
By Date
Final - Plumbing (4075)
Approved
By Date
FILE
Final - Building (4050)
Approved
Date t.—�r?
EJ
Rough Electrical
Approved
Final Electrical
Approved
Right of Way
Approved
By
Date
By
Date
By
Date
c
AL
F�" PERMIT
ed
COMMUNITY DEVELOPMENT SF$�TCS ]ROL I C A T I O N
253 835-2607 FAX 253 835--
f-/63383
(SF MF CO M PL D EN FP
#
SITE ADDRED9PSUITE/UNIT
33831 12th. Place Southwest
PROJECT VALUATION
ZONING
ASSESSOR'S TAX/PARCEL #
$
S 7et,
957814-0110
TYPE OF PERMIT
X BUILDING X PLUMBING X MECHANICAL
❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
(Tenant Name/Homeowner Last
WYNSTONE LOT # 11
Name
PROJECT DESCRIPTION
Detailed description of work to
New construction of Single Family Residence
Quadrant Homes Plan # 1629 A
be included on this permit only
PROPERTY OWNER
NAME Quadrant Homes
PRIMARYPxOxE 425-455-2900
MAILING ADDRESS PO Box 130
=TY Bellevue
TE
w A
Z=P 98009
NAME Quadrant Homes
PHONE 425-455-2900
MAILING ADDRESS PO Box 130
E-MAIL
CONTRACTOR
=TY Bellevue
STATE
ZIP 98009
FAX
WA
WA STATE CONTRACTOR'S LICENSE #
EXPIRATION DATE
FEDERAL WAY BUSINESS LICENSE #
QUADRC*221OF
9110111
19 -90 -101914 -00 -BL
NAME Quadrant Homes
PHONE 425-455-2900
APPLICANT
MAILING ADDRESSPO Box 130
E-MAIL
=TY Bellevue
wA
ZIP 98009
FAX
PROJECT CONTACT
(The individual to receive and
NAME Jennifer Warner
-ONE 425-688-3708
MAILING ADDRESSPO Box 130
E-MAIL
'ennifer.warne uadranthomes.com
respond to all correspondence
concerning this application)
=TY Bellevue
wA
ZIP 98009
FAX 253-928-1560
ALTERNATE CONTACT NAME:
PHONE
E-MAIL
Quinn Wyatt
425-452-6506
quinn.wyatt@quadranthomes.com
PROJECT FINANCING
NAME
OWNER -FINANCED
Required value of $5, 000 or more
MADdNG ADDRESS, CITY, STATE, ZIP
PHONE
(RCW 19.27.095)
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. 1 understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as a part of this applicab"�' ...-i
SIGNATURE: DATE 9/21/2011
PRINT NAME: Jennifer Warner for Quadrant Homes
VALUE OF MECHANICAL WORK $ 0 (a copy of bid or estimate must be provided)
Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain.
1 AIR HANDLING UNITS 6 FANS 3 GAS PIPE OUTLETS OTHER (Describe)
1 AIR CONDITIONER 1 FIREPLACE INSERTS HOODS (Commemiaq
BOILERS 1 1 FURNACES 1 HOT WATER TANKS (Gas)
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
DUCTING 1 GAS PIPING WOODSTOVES
Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain
2 BATHTUBS (or Tub/ Sbo—t Combo)
4 LAVS (Hand Sink,)
3 TOILETS
1 WATER PIPING
1 DISHWASHERS
RAINWATER SYSTEMS
URINALS
OTHER (Describe)
DRAINS
1 SHOWERS
VACUUM BREAKERS
DRINKING FOUNTAINS
2 SINKS (wtoben/utility(
WATER HEATERS (Electric(
2 HOSE BIBBS
SUMPS
1 WASHING MACHINES
LaN 1 5
CRITICAL AREAS ON PROPERTY?
no
EXISTING/PREVIOUS USE
none
WATER PURVEYOR
Lake Haven Utility
LOT SIZE (In Square Feet(
5,105 SF
SEWER PURVEYORI VALUE OF EXISTING IMPROVEMENTS
Lake Haven Utility
EXISTING FIRE SPRINKLER SYSTEM? I PROPOSED FIRE SUPPRESSION SYSTEM?
❑ Yes X No ❑ Yes X No
Bulletin #100 — January 1, 2011 Page 2 of 3 k:AHandouts\Permit Application
hti
-
ADDRESS:
Ln'
PROJECT:
O
l
I\ \
U)
DATE:
9/26/11
3 c o
c0 02f� o 'n
U V d
d N
d O
U N O >li O
a`� °p CD a> O � �
y,
o
d �
L C CJ G
L �-O U� LVi N
� F
rt ¢�aa
p Quo
C/2 3 > m
o N oU�rza
pw1 � zF
co FwOO
ti Q W p U
a �aq
E z w n
C\2 o�qx
�
zo�F
OFpE
co og5zz
0
C4
O V
OFE,OG
?zQQw
ra- a 2,
CD
V
V �U�
gzoWo
�FzwF
a[ev�wa
OF(YO
x0.VOC.
O Hw0? w
N o �E^rt7E-
¢F�WF
FGO 0
O
PERMIT #:
11 -103843 -00 -SF
ADDRESS:
33831 12th PI SW
PROJECT:
New Single Family
WYNSTONE LOT 1 1
DATE:
9/26/11
c
co
0
z
z
0
7)
zi
O o
0
C�2
z
a
o p
3 O C\2
co
Q O N
LU
re
o u)
LU 'CIZ4 LU U
LU w 0