Loading...
02-104299 Fece o€ 110 CityraiWay S , Codon yDeveiopr•ntservices Building - Commercial Permit #:02 - 104299 - 00 - CO ommun33530 1st Way S Federal Way,WA Q8003-6210 Ph:253.661 4000 Fax:253.641 4,129 Inspection request line: 253.835.3050 Project Name: KENNEDY JENKS Project Address: 32001 32ND S 5u.,*1_, i ob Parcel Number: 162104 9001 Project Description: TI-Initial tenant improvement to portion of 1st floor for new office space; Includes plumbing and mechanical work. Owner Applicant Contractor Lender FOSS REDEVELOPMENT JPC ARCHITECTS*DAVID HELTOI G L Y CONSTRUCTION FOSS REDEVELOPMENT PO BOX 94449 13201 BEL-RED RD GLYCOI01809 9/30/02 PO BOX 94449 SEATTLE WA 98124 BELLEVUE WA 98005 PO BOX 6728 SEATTLE WA 98124 BELLEVUE WA 98008-0728 Includes: Census category: 437-Comm #1 #2 #3 #4 i Occupancy Group: B Construction Type: Type II-FR -- Occupancy Load: 160 Floor Area(Sq.Ft,): 16387 1st Floor Proposed Sq.Feet 16387 Building Pre-con.Meeting Required No Census Category 437-Commercial alt/add Fire Sprinklers Yes Mechanical Yes Number of Stories 4 Permit for Building Shell Only No Permit for Foundation Only No Plumbing Yes Special Inspection Required No Will Certificate of Occupancy be Issued? Yes Zoning Designation OP-1 Plumbing Fixtures Quantity Qcian Drains . :Description , k, a K Q_ ij'aritity 2 Dishwashers 1 Lavatories 2 Water Heaters 1 Showers L 4 Sinks 2 1 Mechanical Fixtures f e crept©n .. uartti Descri tion;NMI N 'g�i r tl# .. � P _ ! p � _ "�flescei tion Qilantit' Air Handling Units 13 Compressors 1 Fans Ducts 1 CONDITIONS: 1.All new and refaced signs require a separate sign application and review.(FWCC,Sec.22-335(g)(6)). PERMIT EXPIRES April 26,2003,IF NO WORK IS STARTED. Permit issued on October 28,2002 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washington and the City of Federal / Owner or agent: Date: (0 / 2 & ` 02, • 411/ Ci� bf Ftderal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code certifying that at the time of issuance,this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: KENNEDY JENKS Permit number: 02- 104299-00 Address: 32001 32ND S #1 #2 #3 #4 Occupancy Group: Construction Type: Type II-FR Occupancy Load: 160 Floor Area(Sq.Ft.): 16387 Owner FOSS REDEVELOPMENT Name: PO BOX 94449 Address: SEATTLE WA 98124 MA. 4146.6..t coo 104701 --0 3 Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. 1 0 , - INSPECTION LOG DATE lltiAl INSPECTOR' OK CORR/REJ AREA AND TYPE OF INSPECTION l ' � -era pirkr t(o b ails( we6 c.or -i /1-9,2 S7 i'yH ,,, 562. c //, u:.4✓l//Vo-Sac a / ./.4 C',rd _h- - Z, , . i 'au- s'I- .. P .S' aZj s-e_../ hood "r"ot.._ ,,,fik'—'-----.2712t..te. ..----- ..rt.,.,_II 1,3.t:t.i., ..,,.....A-L_ .1,3e) , s/� yIrSfri L A-------- el€.61 i It o!l it\ etr pert,«- - L,1°uO < , cete 1 e X01,4 sJr/2. iZ (y .1p—foil/lei (eltr 'lir Saulk todAc rx(-ep 1031/ 1033/ 103.5 1cA7/ 3 f %)lips oz ss l `I POSTHIS CARD ON THE FRONT OF BUILDIN "`"°F G BUI NG DIVISION uv Ffl' INSPECTION RECORD INSPECTION REQUEST PHONE#: 253-835-3050 PERMIT#: 02-104299-00-CO OWNER'S NAME: WEYERHAEUSER REAL ESTATE SITE ADDRESS: 32001 32ND S ( ) FOOTINGS/SETBACKS ( ) FOUNDATION WALL DO NOT POUR CONCRETE UNTIL THE ABOVE IS APPROVED ( ) DRAINAGE: Line ( ) Connection ,33` DO NOT POUR S>.AB UNTIL'THE ABOVE IS APPRO'�ED ( ) UNDERFLOOR FRAMING ( ) ROUGH PLUMBING: DWV,�q �/ /7/lel' Water piping 0 ROUGH MECHANICAL U Gas piping ( ) SHEATHING Roof Floor ( ) SHEAR WALLS () ELECTRICAL ROUGH-IN Ditch Cover () FIRE/DRAFTSTOPS ALL THE ABOVE"MUST BE APPROVED ERIOR TO FRAMING INSPECTION; ( ) FRAMING/FIRESTOPPING THE A1OVE MUST,BE APPRO\'ED PRIOR TO INSULATING,OR'SHEETR,OCKING ( ) INSULATION: Floors Walls Attic „"THE ABOVE MUST°BE APPROVED„PRIOR TO APPLYING"SHEETROCK , 0) WALLBOARD NAILING () SUSPENDED CEILING %z — /6-aZ THE ABOVE MUST-BE"APPROVED PRIOR TO 5fAPING,OR INSTALLINGG CEWING"TILE 0) ELECTRICAL FINAL ( ) PLANNING FINAL () PUBLIC WORKS FINAL 0) FIRE FINAL THE ABOVE;MUST BE APPROVED PRI R;TO BUILDING D PARTMENT FINAL O BUILDING FINAL 12 le DO 'NOT OCCUPY THIS BUILDING�UNTIL BUILDING FINAL IS.APPROVEI) • , _ RPCEIVED G CONSTRUCTION PERMIT APPLICATION W OCT 0 2 2002 APPLICATION NUMBER: OZ — / Z f 1 — &to CO • APPLICATION NUMBER: _ _ — _ _ _ _ _ __ _ r CITY OF FEDERAL WAY BUILDING DEPT. APPLICATION NUMBER: _ _ — **The following is required information—Please print(in ink)or type** Please note: Electrical,Fire Prevention Systems and Engineering permits may require a separate application. • PROPERTY INFORMATION SITE ADDRESS: 32001 32nd Ave.South ASSESSOR'S TAX/PARCEL#: 2 1 5 4 6 5 - 0 0 1 0 LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY): Lot A of"East Campus Corporate Park Parcel"1",as described in City of Federal Way Site Plan(City File No. BSP 98-0003)recorded September 16, 1999(note to Dave-this date is not a typo)under recording No. 19990916001397,in King County,Washington. LOT B Lot B of"East Campus Corporate Park Parcel"1",as described in City of Federal Way Site Plan(City File No. BSP 98-0003)recorded September 16, 1999 under recording No. 19990916001397,in King County,Washington. • PROJECT INFORMATION TYPE OF PROJECT(This application): BUILDING ,LUMBING ;,MECHANICAL ❑ DEMOLITION ❑ ELECTRICAL 0 ENGINEERING 0 FIRE PREVENTION SYSTEM • PROJECT DESCRIPTION(Provide detailed description): Tenant improvement in existing building-location on the first floor. PROJECT NAME: Kennedy Jenks Tenant Improvement • PEOPLE INFORMATION PROPERTY OWNER: NAME: DAYTIME PHONE: FRC Federal Wav LLC ( 206 ) 262-1400 MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): PO Box 94449 Seattle,WA 98124 CONTRACTOR: NAME: DAYTIME PHONE: GLY ( 425 ) 451 — 8877 MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): EVENING PHONE: 100—116th Avenue S.E. Bellevue,WA 98008 ( 425 ) 451 — 8877 CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: FAX NUMBER: 2 0 - 10 16 4 4 - B L ( 425 ) 453 -5680 CONTRACTOR'S REGISTRATION NUMBER: EXPIRATION DATE: (copy of card required) G L Y C O I * 018 0 9 9 /30 /2002 APPLICANT: NAME: DAYTIME PHONE: David Helton/JPC Architects ( 425 ) 641 — 9200 MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP): EVENING PHONE: 13201 Bel-Red Road Bellevue,WA 98005 ( ) - RELATIONSHIP TO PROJECT: FAX NUMBER: X ARCHITECT ❑TENANT ❑ OTHER(DESCRIBE): ( 425 ) 637 — 8200 E-MAIL ADDRESS: CONTACT PERSON FOR THIS PROJECT: 0 PROPERTY OWNER X APPLICANT o CONTRACTOR davidhCalipcarchitects.com • DETAILED BUILDING INFORMATION EXISTING USE: Type B-Office EXISTING BUILDING ASSESSED/APPRAISED VALUATION $ 12,176,100.00 PROPOSED USE: Type B-Office PROPOSED VALUATION FOR IMPROVEMENTS: $ 700,000.00 SPRINKLERED BUILDING? X YES ❑ NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED: X YES o NO WATER SERVICE PROVIDER: X LAKEHAVEN ❑ HIGHLINE 0 TACOMA ❑ PRIVATE(WELL) SEWER SERVICE PROVIDER: X LAKEHAVEN o HIGHLINE o PRIVATE(SEPTIC) I • **NEW RESIDENTIAL CONSTRUCTION ONLY** • NUMBER OF BEDROOMS: ESTIMATED SELLING PRICE: $ • PROJECT FLOOR AREAS FLOOR EXISTING SQ.FT. PROPOSED SQ.FT. TOTAL BASEMENT FIRST 0 16,387 SECOND THIRD FOURTH OTHER FLOORS(DESCRIBE) DECK GARAGE HOW MANY FLOORS? TOTAL: • FIXTURES Indicate number of each type of fixture MECHANICAL CL/i4-v 5 C3 AIR HANDLING UNITS) EVAPORATIVE COOLER(S) GAS LOG(S) REFRIG.SYSTEM(S) BBQ(S) 1 FAN(S) HOOD(S) WOODSTOVE(S) BOILER(S) FIREPLACE INSERT(S) RANGE(S) t3 141SC4.MAV) I COMPRESSOR(S) FURNACE(S) X - DUCT(S) GAS PIPE OUTLET(S) HEAT SOURCE:X ELECTRIC o GAS PLUMBING BATHTUB(S) 2 LAVATORY(S) URINAL(S) 1 WATER HEATER(S) 1 DISHWASHER(S) RAIN WATER SYS. VACUUM BREAKER(S) ❑ ELECTRIC o GAS DRINKING FOUNTAIN(S) 4 SHOWER(S) WASH MACHINE OUTLET GAS PIPE OUTLET(S) 2 SINK(S) WATER CLOSET(S) 2 MISC. (Drains_) INTERCEPTOR(S) SUMP(S) • DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the City of Federal Way,but only where such claim arises out of the reliance of the city,including its officers and employees,upon the accuracy of the information supplied to the city as a part of this application. NAME/TITLE: David Helton/Project Architect DATE: 10.2.2002 o PROPERTY OWNER X APPLICANT ❑ CONTRACTOR N.:1) FOR OFFICE USE ONLY:.. o NEW o ADDITION ❑ALTERATION ❑ REPAIR o TENANT IMPROVEMENT CENSUS CODE: LOT SIZE: ZONING DESIGNATION : BUILDING SHELL ONLY? ❑YES 0 NO COMP PLAN DESIGNATION BASIC PLAN? o YES o NO SECTION TOWNSHIP RANGE NEW ADDRESS REQUIRED? o YES ❑ NO PLATTED LOT? o YES ❑ NO CHANGE OF USE? ❑YES ❑ NO COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•PO BOX 9718•FEDERAL WAY,WA 98063-9718•253-661-4000•FAX:253-661-4129 ww.atvoffecera!wav corn • Construction Permit Fee Calculation Sheet *******PLEASE NOTE: ALL FEES MUST BE VERIFIED BY CITY STAFF PRIOR TO ACCEPTANCE OF PAYMENT. CHECKS FOR INCORRECT AMOUNTS WILL NOT BE ACCEPTED!******* Building,mechanical,and fire prevention system fees are based on the following schedule. TABLE A TOTAL VALUATION FEE FACTOR (1)$1.00 to$500.00 (1)$26.00 (2)$501.00 to$2,000.00 (2)$26.00 for the first$500.00 plus$3.50 for each additional$100.00 or fraction thereof,to and including $2,000.00 (3)$2,001.00 to$25,000.00 (3)$78.50 for the first$2,000.00 plus$15.50 for each additional$1,000.00or fraction thereof,to and including$25,000.00 (4)$25,001.00 to$50,000.00 (4)$435.00 for the first$25,000.00 plus$11.00 for each additional$1,000.00or fraction thereof,to and including$50,000.00. (5)$50,001.00 to$100,000.00 (5)$710.00 for the first$50,000.00 plus$8.00 for each additional$1,000.00 or fraction thereof,to and including$100,000.00. (6)$100,001.00 to$500,000.00 (6)$1,110.00 for the first$100,000.00 plus$6.00 for each additional$1,000.00 or fraction thereof,to and including$500,000.00 (7)$500,001.00 to$1,000,000.00 (7)$3,510.00 for the fist$500,000.00 plus$5.50 for each additional$1,000.00 or fraction thereof,to and including$1,000,000.00. (8)$1,000,001.00 and up (8)$6,260.00 for the first$1,000,000.00 plus$4.00 for each additional$1,000.00 or fraction thereof. Bold number is the base fee for the specified increment Italicized,underlined number is the fee per additional specified increment PLUS: Add 65 percent of the base building permit fee for plan review fee. Add 25 percent of the base mechanical permit fee for mechanical plan review fee. Add 15 percent of the base building permit fee for Fire District#39 surcharge,commercial only. Add$4.50 for WA State Building Code Council,plus$2.00 per unit for duplex&above. **Electrical,plumbing,and mechanical fees are calculated separately** • BUILDING PROPOSED VALUATION: $700,000.00 FEE FACTOR FROM TABLE A: Number: 7 (a)Base Fee: 3510 (b)Additional Increment Fee: 1110 Estimated Permit Fee: (1) 4620 Estimated Plan Review Fee: (2) 3003 Estimated FIN Fire Department Surcharge: (3) 693 (COMMERCIAL ONLY) ■ MECHANICAL PROPOSED VALUATION: $67,900 FEE FACTOR FROM TABLE A: Number: 5 (a)Base Fee: $710 (b)Additional Increment Fee: $143.20 Estimated Permit Fee: (4) $853.20 Estimated Plan Review Fee: (5) $213.30 • FIRE PREVENTION SYSTEM PROPOSED VALUATION: 15,000 FEE FACTOR FROM TABLE A: Number: 3 (a)Base Fee: 78.50 (b)Additional Increment Fee: 201.50 Estimated Permit Fee: (6) 280 Estimated Plan Review Fee: (7) ■ PLUMBING Base Fee Number of Fixtures $22.50+{ 12 X$8.00/fixture}= $96.00 (8)Estimated Permit Fee Estimated Permit Fee 96 X .65= $62.40 (9)Estimated Plan Review Fee Miscellaneous Fixture Charge:(10) 0 Sub Total (Page One): Line(s)(1)+(2)+(3)+(4)+(5)+(6)+(7)+(8)+(9)+(10)= (11)