Loading...
17-103930 ' he, V • Building - Single Family City of Federal Way Permit #:17-103930-00-SF Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax(253)835-2609 Project Name: DUENAS Project Address: 2104 SW 349TH PL Parcel Number: 176110 0010 Project Description: ADD-Construct 200 square foot addition on second story level.No plumbing or mechanical. Owner Applicant Contractor Lender LUCIANO DUENAS LUCIANO DUENAS OWNER IS CONTRACTOR HOMEOWNER IS LENDER 2104 SW 349TH PL 2104 SW 349TH PL FEDERAL WAY WA FEDERAL WAY WA 98023-3071 98023-3071 Census Category:434-Residential alt/add-no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 0.00 0.00 Additional Permit Information New/Additional Sq.Feet-1st Floor 0 New/Additional Sq.Feet-2nd Floor 200 New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 0 New/Additional Sq.Feet-Basement. 0 Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 0 Mechanical to be Included? No Plumbing Work Valuation 0 Mechanical Work Valuation 0 Number of Stories 2 New/Additional Sq.Feet-Other 0 Is this an Online or O.T.C.application No Plumbing to be Included? No New/Additional Sq.Feet-Total 200 Occupancy#1-Use Residence(1 or 2 Comprehensive Plan Designation SF-High-Density family) Residential Zoning Designation RS 7.2 Total Valuation:23,230.00 PERMIT EXPIRES Monday,7 May,2018 Permit Issued on Wednesday,November 8,2017 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: U) tlin CO ‘..ypin cts Date: 11 02— • II.-ATFINSPECTOR AREA AND TYPE. OF INSPECT iO ;' .VA))./A ,Y 0 - Y1.5‘41 "' N �,� r, a K (e( 7/6/1 r ..(2142v - s,;�s oma. +- THIS CARD IS TO REMAIN ON-SITE _ ' CITY Of Construction Inspection Record ' Federal Way INSPECTION REQUESTS:(253)835-3050 PERMIT#: 17 103930 00 Address: 2104 SW 349T1I PL Project: LUCIANO DUENAS FEDERAL WAY WA 98023-3071 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. • 0 SWM Precon Site Mtg(4400) 2❑ Initial Erosion Control(4365) 3 Q Footings/Setback(4110) Approved To be done PRIOR to breaking ground Approved to place concrete �By Date ,...EI Date �`By Date ® Foundation Wall(4115) ' E Drainage/Downspout(4040) ® Slab/Concrete Floor(4255) Approved to place concrete Approved to backfill Approved to place concrete By Date ! By Date By Date 7❑ Underfloor Framing(4285) I ® Floor Sheathing(4105) j ® Shear Walls(4245) Approved to sheath floor Approved to install flooring Approved to install siding By Date By,, < > Date I k.1 = By k` Date 1q Roof Sheathing(4220) 0 Fire/Draft Stops(4095) EiInterim Erosion Control(4370) Approved to install roofmg Approved Approved e. Date l 01 t(f7 By Date ABy Date Prior to scheduling a Framing inspection; ©3 Framing(4120) 14 Insulation(4150) Electrical,Plumbing&Mechanical Rough-inibm, Approved to insulate j Approved to install wallboard and Fire/Draft Stop roved. ionsIBC mast be andslppaed- ottapproved. IBC 109 3.4 By ila Date I a By 4` Date 2 4 IS/ 0 Gypsum Wallboard Nailing(11A 00) ' Final Erosion Control(4375) I Final-Building(4050) Approved to install mud&tape �J// Approved i Approved By Date .�_By Date �_ByQ � Date 2 l L.f� 0 Rough Electrical 0 Final Electrical 0 Right of Way Approved Approved Approved By Date By Date By Date milli :44 a RECEIVED I RMIT APPLICATION,T ceeraF 1 Way Al 156i.iJii /�JMIT CENTER+33325 8th Avenue South+Federal Way,WA 98003-6325 3-835-2607+FAX 253-835-2609+permitcente i cityoffederalwaY.com CITY OF FEDERAL WAY CcMurv03 '30a ` s/12/11 PERMIT NUMBERI7".._ 1 DEVELO - - - TARGET DATE SITE ADDRESS SUITE/UNIT# 2 r 041 5W Li K Th PL rectevctl 0),w Lull tS'©Z3 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# TYPE OF PERMIT ZBUILDING 0 PLUMBING 0 MECHANICAL Jd DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT YVCNA PROJECT DESCRIPTION g w'6 d t l 1.4-€ U e r t V f know- PROJECT Detailed description of work to be included on this permit only — NAME PRIMARY PHONE Luciano Duerr 253- of/ 3l 7L PROPERTY OWNER MAILING ADDRESS EMAIL 2,101 5w 341Ci" PL CITY STATE ZIP Fecett,\ way w" etY0Z3 }NAME ` PHONE !)OW E-MAIL MAILING ADDRESS CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# / / NAME PRIMARY PHONE LuCfgr-t, OU'e A ct . 75'5 - z' 7-5/32. APPLICANT MAILING ADDRESS E-MAIL Zt 04 5u� 340 r°L CITY STATE ZIP FAX f ed t Kt t t y wA t s`o L3 NAME PRIMARY PHONE PROJECT CONTACT c 121W L 61412--C-I i 50 3 PO zii / ? (The individual to receive and MAILING ADDRESS EMAIL respond to all correspondence 5li r R p n h -AOL• ''I concerning this application) CITY STATE ZIP FAX NAME PROJECT FINANCING 0 OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. L (kclfl p /SIGNATURE: •1')u? DATE ' 1 is I zo t+ PRINT NAME: L i'C(A-,) " r)lt' c1 Bulletin#100–January 29,2016 Page 1 of 2 k:\Handouts\Permit Application VALUE OF MECHANICAL WORK MECHANICAL PERMIT Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include - g fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS(Commercial) BOILERS FURNACES HOT WATER Ti 'S(Gas) COMPRESSORS GAS LOG SETSREFRIG '.• ION SYST GAS PIPING \DUCTING W•'s D STOVES VALUE OF PLUMBING WORK PLUMBING PERMIT `V\ Indicate how many of each type of fixture to be tal-• or relocated as part of this project.Do not include existing fixtures to remain. BATHTUBS(or Tb/shower Combo) LAVS and sinks) TOILETS WATER PIPING DISHWASHERS '.N NWATER SYSTEMS URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS(Kitchen/utility) WATER HEATERS(ElecGic) -_ HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS 5000 EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? (' 2 ❑Yes❑ No 0 Yes ❑ No �eS`(aevt -;Ct� �S RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT FIRST FLOOR(or Mobile Home) ! ( ( SECOND FLOOR Z� '1-00 C 2.0 COVERED ENTRY DECK GARAGE ❑ CARPORT ❑ OTHER(describe) EXISTING PROPOSED TOTAL Area Totals 1530 2-00 (7-3 **NEW HOMES ONLY** ESTIMATED SELLING PRICE$ #OF BEDROOMS COMMERCIAL-NEW/ADDITION AREA DESCRIPTION Area m OccupancyConstruction #of Square Feet Group(s) Type Stories Additional Information NEW BUILDING ADDITION 200 1 vif $1'lq Ce—: /WW1 ) EJC'-fn bed reel is-‘ COMMERCIAL-REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area In Occupancy Group(s) Construction #of Additional Information Square FeetType Stories TOTAL BUILDING TENANT AREA ONLY PROJECT AREA ONLY 2,00 1:01 ( t Bulletin#100-January 29,2016 Page 2 of 2 k:\Handouts\Permit Application DUENA5 ADDITION OWNERS) LUCIANA DUENAS LEGAL DE5RIPTION 2104 5E 349TH PL FEDERAL WAY, WA 98023 PIERCE COUNTY PARCEL #G825000290 ZONE: SINGLE FAMILY/ RE51DENCTIAL USE JURISDICTION: FEDERAL WAY PL55: 5E-24-21-3 GENERAL SITE WORK NOTES: DESIGN CRITERIA: LIST OF DRAWINGS ROOF G 1.0 GENERAL NOTES LIVE LOAD = 25P51 PLOT PLAN DEAD LOAD = 151`51 A1.0 2ND FLR PLAN (A5-BUILT) FLOOR 2ND FLOOR FRAMING _LIVE LOAD = 451`51 A2.0 2ND FLR ADDITION DEAD LOAD - 151`51 ROOF FRAMING WIND = 85 MPH A3.0 ROOF PLAN EXPOSURE = C SECTIONDETAILS 51E5MIC ZONE = D I A4.0 ELEVATIONS I . CONTRACTOR TO PROVIDE EROSION, SILTATION AND CONSTRUCTION ACCESS CONTROL MEASURES, IF NEEDED, PER THE CITY OF FEDERAL WAY AND THE 2014 5TORMWATER MAINTENACE MANUAL FOR WESTERN WASHINGTON. 2. PLACE COMP05T SOCKS, COMPOST BERMS, FILTER FABRIC FENCING, STRAW WATTLES, STRAW BALES OR OTHER APPROVED PERIMETER 15MP5 TO ELEMINATE CONSTRUCTION 5TORMWATER RUNOFF. 3. COVER BARE SOIL WITH COMPOST BLANKETS, STRAW, MULCH, MATTING OR OTHER APPROVED EQUAL TO CONTROL CONSTRUCTION 5TORMWATER RUNOFF. 4. COVER ANY STOCKPILES WITH MATTING OR POLY TO PREVENT RUNOFF 5. IF CONSTRUCTION ACCESS IS NEEDED, OTHER THAN EXISTING PAVED ROADS, A TEMPORARY BARRIER MUST BE USED TO PROTECT VEGETATION, SUCH AS PLYWOOD, THEN REMOVED AS 50ON AS CONSTRUCTION 15 COMPLETE. G. CONTROL AND STORAGE OF ANY POLLUTION GENERATING MATERIALS SUCH AS CONCRETE, SOLVENTS, CONCRETE WASH WATER, PAINT OR DRYWALL MATERIALS, MUST BE MAINTANED TO PREVENT IT FROM ENTERING INTO 5TORMDRAIN5. 7. DE -WATERING BAG5 5HALL BE USED WHERE VEGETATION IS NOT ADAQUATE TO PREVENT RUNOFF OF FOUNDATION DE -WATERING, AND IS RECOMENDED. 8. SPILL KITS SHALL BE KEPT ON51TE AS A PRECAUTION. 9. ALL NEW GUTTER AND DOWNSPOUTS SHALL CONNECT TO EX151TING GUTTERS AND DOWNSPOUTS PER PLAN. FOUNDATION NOTES: I . ALL FOOTINGS SHALL BEAR ON FIRM, UN DISTURBED 501L OR ROCK. 2. ALL WELDED WIRE AND REINFORCING STEEL SHALL CONFORM TO ASTM 5TD5. 3. PROVIDE 3" MINIMUM CONCRETE PROTECTION FOR ALL REINFORCING STEEL. 4. DAMP-PROOF ALL BELOW -GRADE FOUNDATION WALL WITH 2 COATS OF ASPHALT EMULSION IF REQUIRED BY LOCAL BUILDING CODE. 5. 2X FOUNDATION PLATES OF PRESSURE TRT'D MATERIAL 5HALL BE INSTALLED G" MINIMUM ABOVE GRADE WITH %8' 0 X 10" ANCHOR BOLTS @ 4' O.C. WITH 3" X 3"X 1/4" PLATE WASHERS. FLOOR FRAMING NOTES: I . DOUBLE JOISTS UNDER ALL INTERIOR BEARING WALLS. 2. ANY BUILT UP JOISTS AND HEADERS SHALL BE BOTH GLUED AND NAILED. 3. JOISTS SHALL BE SUPPORTED LATERALLY AT EACH END BY BLOCKING OR CONTINUOUS RIM BOARD TO PREVENT ROTATION. 4. FRAMING CONNECTORS SHALL BE 51MP50N STRONG TIE OR EQUIVALENT, INSTALLED PER MANUFACTURER'S 5PEC'5. 5. FLOOR SHEATHING SHALL BE 3/4" APA RATED MINIMUM APPLIED WITH LONG AXI5 PERPENDICULAR TO JOISTS, GLUED AND NAILED. STAGGER PANELS. G. GIRDER SPLICES SHALL OCCUR OVER SUPPORT AND BE ADEQUATELY TIED. ENDS TO HAVE 3" MINIMUM BEARING AND 1/2" MINIMUM AIR SPACE. 7. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TRT'D OR EQUIVALENT. 8. ALL FLOOR SHEATHING SHALL BE %` APA RATED TAG SHEATHING W/ 8d NAILS @ G" O.C. EDGE NAILING * 12" O.C, FIELD NAILING, UNLE55 NOTED OTHERWISE. GLUE SHEATHING TO SUPPORTING FRAMING PRIOR TO NAILING. FRAMING * GENERAL NOTES: I . THE CURRENT BUILDING CODE AND ALL OTHER LOCAL CODES SHALL BE STRICTLY FOLLOWED DURING CONSTRUCTION. 2. DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS. NOTIFY DESIGNER OF ANY SUSPECTED ERRORS OR OMISSIONS PRIOR TO PROCEEDING. 3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO CONSTRUCTION OR ORDERING MATERIALS. Z 4. UNLE55 OTHERWISE NOTED, PLAN DIMENSIONS ARE TO FACE OF STUDS. FACE OF CONCRETE AND CENTERLINE OF OPENINGS. o 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES REQUIRED TO PERFORM THE WORK DESCRIBED. G. CONTRACTOR SHALL PROVIDE TEMPORARILY BRACING AS REQUIRED UNTIL ALL PERMANENT MEMBERS AND CONNECTIONS HAVE BEEN INSTALLED. 7. ALL EXTERIOR FRAME WALLS SHALL BE 2XG UNLE55 NOTED. ALL INTERIOR WALLS SHALL BE 2X4 UNLE55 OTHEKW15E NOTED. 8. STUDS IN BEARING WALLS SHALL BE DOUBLED IF MORE THAN GO% OF STUD WIDTH IS REMOVED. IN NO CASE SHALL BORED HOLES BE LE55 THAN 5/8" FROM STUD FACE. 9, UPLIFT AND SLIDING ANCHORAGE SHALL BE ADEQUATELY PROVIDED TO ALL ROOFS, BEAMS, POSTS, AND WALLS (8' IN FIRE WALLS) 10, GIRDER5, BEAMS, CONNECTORS AND ALL STRUCTURAL COMPONENTS SHALL BE CAPABLE OF CARRYING THE LOADS IMP05ED 50LIDLY TO GRADE, ALL COMPONENTS TO BE SOLIDLY BLOCKED OR HAVE METAL FRAME CONNECTORS INSTALLED AS PER MANUFACTURER. 1 1. ALL TOP PLATES SHALL BE DBL 2xG OR 2X4 DF #2 OR BTR 12. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TRT'D. 13. ALL FOUNDATION PLATES SHALL BE A MIN. G" ABOVE GRADE AND PRE55URE TRT'D, PLATES TO BE BOLTED WITH 5/8" X 10" ANCHORS @ G' O.C. AND SECURED WITH 3" X 3" X 1/4" PLATE5 (MIN. 2 PER BOARD AND NOT MORE THAN 12" FROM AN END, UNLE55 SPECIFIED BY AN ENGINEER. 14. GIRDER SPLICES SHALL OCCUR OVER SUPPORT AND BE ADEQUATELY TIED. ENDS TO HAVE 3" MIN. BEARING AND I/2" MIN. AIR SPACE. 15, COLUMNS AND POSTS SUPPORTED ON PIERS OR METAL PEDESTALS SHALL BE KEPT I " ABOVE ALL FLOOR S AND G" ABOVE EARTH I G. FIREBLOCK SHALL B E PROVID� CONCEALED DRAFT OPENINGS �P�iGS,I� kT f l0•1�./�.t.�I��`j AND AT I O' MAX. IN ALL 5TAN LL5 (8' MAX. IN FIRE WALLS). 17, REFERENCE ELECTRICAL PLAN FOR SMOKE AND CO DETECTION DEVICES Aor"3lot a/C. (EI.0) r 18. PER 2015 W5EC, R402.4.1.2, AN AIR LEAKAGE TEST SHALL BE PERFORMED AFTER ROUGH IN CONSTRUCTION 15 COMPLETED. ROOF FRAMING NOTES: I . HEADERS TO BE (2) 2 X 10 #2 DOUGLAS FIR UNLE55 NOTED OTHERWISE, 2. JOISTS AND RAFTERS TO BE #2 DOUGLAS FIR UNLE55 NOTED OTHERWISE 3. TRUSSES SHALL CARRY THE MANUFACTURERS STAMP AND HAVE THE ENGINEERING DRAWING ON 51TE FOR INSPECTION, 4. NO TRUSS SHALL BE FIELD MODIFIED WITHOUT PRIOR APPROVAL OF ENGINEER AND/OR THE BUILDING DEPT. 5. FRAMING CONNECTORS SHALL BE 51MP50N STRONG TIE OR AN APPROVED EQUAL AND INSTALLED PER MANUFACTURERS SPECIFICATIONS. G. INSTALL 51MP50N H I CLIPS AT EACH END OF EACH RAFTER OR TRUSS. 7. ALL ROOF SHEATHING SHALL 15EV2" NOMINAL APA RATED SHEATHING W/ 8d NAILS @ G" O.C. EDGE NAILING � 8d NAILS @ 12" O.C. FIELD NAILING, UNLESS NOTED OTHERWISE 92' 51DEWALK PROPERTY LINE 2015 IRC R109.4 Approval Required Work shall not be done beyond the point indicated in each SW349TH PL successive inspection without first obtaining the approval of the building official The building official upon notification shall SITE PLAN SCALE: I "= 10' official. Egress Windows required for bedrooms shal ' fy the following requirements, per 2015 R 310 • Minimum net clear opening of 5.7 s.f. (grade floor windows may have a minimum opening of 5 sf) • Minimum net clear opening width of 20 inches. • Minimum net clear opening height of 24 inches. • Maximum sill height of 44 inches above floor. /_� AIVE IN W1 F co;'-Aa th (ti S i (' C LUka�-- 011 � WU Qt IJCC� G RECEIVED AUG 15 2017 CITY F FEDERAL y COA4 U�TYDEVELOPNENT f- r� boo - 641 4k z ago O a� z �Q � N z0�» U=�=aN 8VILak 9nEs>g���l� W I-E -gag, 2f O 6 PC pp U GCC0 2 llIIhh Er T p 3 m O J Z D_ Q Oz�� C) ) Q E U� Q (n J :;7z Q w w U O p i�JNIWL REVISIONS NO. DATE BY I z, E DATEOVAL:MITTAL:IVED:CS: jAR Ili I 24"x36" SCALE: AS NOTED PLOT DATE:7/20/17 CAD FILE: JOB NUMBER: 071 CHECKED: DRAWN: MPM STATUS: REVIEW. COVER SHEET - R � 5�F GI.