Loading...
17-101545 Building - Conm ercial Commityof Way Permit #:17-101545-00-CO 33325 8th Ave S Federal way, Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: LAKEHAVEN WELL 25 GENERATOR Project Address: 31001 8TH AVE S Parcel Number:082104 9029 Project Description: ADD-Construction of a structural slab for the installation(by separate permit)of a diesel- fueled emergency back-up generator. Installation of UL listed equipment by Electrical Permit. Fire department final required. Owner Applicant Contractor Lender LAKEHAVEN UTILITY DISTRICT KENNEDY/JENKS NORTHEAST ELECTRIC LLC OWNER IS LENDER PO BOX 4249 CONSULTANTS,INC 1780 DOWN RIVER DR FEDERAL WAY WA 98063 32001 32ND AVE S SUITE 100 WOODLAND WA 98674 FEDERAL WAY WA 98001 Census Category: 437-Commercial alt/add/conversion Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area(sq.ft.) Additional Permit Information Mechanical to be Included? No Number of Stories 1 Is this an Online or O.T.C.application? No Permit for Building Shell Only? No Plumbing to be Included? No Comprehensive Plan Designation SF-High-Density Residential Zoning Designation RS 7.2 Total Valuation:10,000.00 PERMIT EXPIRES Monday,7 May,2018 Permit Issued on Wednesday,November 8,2017 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Kr 91 Washington and the City of Federal Way. Owner or agent: �/ /J4 Date: I/ 8- 17 ` ch .k./Y1 THIS CARD IS TO REMAIN ON-SITE `m°* Construction Inspection Record Federal Way INSPECTION REQUESTS:(253)835-3050 PERMIT#: 17 101.545 00 Address: 31001 8TH AVE S Project: LAKEHAYEN UTILITY DISTRICT FEDERAL WAY WA 98003-4703 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. /El Initial Erosion Control(4365) • ,, El Footings/Setback(4110) El Foundation Wall(4115) To be done PRIOR to breaking ground Approved to place concrete Approved to place concrete By Date By Date By Date ® Drainage/Downspout(4040) ' El Re-steel(4215) El Slab/Concrete Floor(4255) Approved to backfill Approved to place concrete or grout Approved to place concrete By Date By Date By Date 1 17,.y.1(e r El Underfloor Framing(4285) El Floor Sheathing(4105) ® Shear Walls(4245) Approved to sheath floor Approved to install flooring Approved to install siding By Date BY Date By Date "to Roof Sheathing(4220) El Fire/Draft Stops(4095) ' El Interim Erosion Control(4370) Approved to install roofmg Approved Approved . By Date By Date By Date Prior to scheduling a Framing inspection; 13 Framing(4120) • El Insulation(4150) Electrical,Phumbing&Mechanical Rough-in Approved to insulate Approved to install wallboard and Fire/Dratt Stop inspections must be signed- off and approved. IBC 109.3.4 By Date : By Date El Gypsum Wallboard Nailing(4130) '. [El Suspended Ceiling Grid(4265) El Final-S K F&R(4060) Approved to install mud&tapeApproved to drop tile Approved By Date By Date By Date 18 Final-Planning ' 19 Final Erosion Control(4375) El Final-Building(4050) Approved Approved Approved By Date r•By Date By ( 03,„� Date 3 --3 a _) g 0 Rough Electrical El Final Electrical 0 Right of Way Approved Approved Approved By Date By Date By Date RECEIVED ‘6,.. PERMIT APPLICATION CITY OF APR 05 2017Federal Way PERMIT CENTER+33325 8th Avenue South+Federal Way,WA 98003-6325 253-835-2607+FAX 253-835-2609+permitcenter[icitvoffederalway.com CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT` PERMIT NUMBER / - / d / 5 (G J - l/r� TARGET DATE SITE ADDRESS 31 01 8th Avenue South SUITE/UNIT# Federal Way, WA 98003 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ /;x , 000 RS7 . 2 0 8 2 1 0 4 _ 9 0 2 9 TYPE OF PERMIT (E BUILDING 0 PLUMBING ❑ MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT Well 25 Generator Improvements Project (38989) Installation of 300 kW emergency diesel engine-generator PROJECT DESCRIPTION in sound-attenuating enclosure with UL-142 listed Detailed description of work to be included on this permit only subbase 72 hour (1700 gallon) fuel tank on concrete foundation. NAME PRIMARY PHONE Lakehaven Water & Sewer District (LWSD) (253) 941-1516 PROPERTY OWNER MAILING ADDRESS E-MAIL 31627 1st Avenue South CITY STATE ZIP Federal Way WA 98003 NAME - d A q,vCa 4 �� i PHONE E'} '' 0111y r�-rrrrt (- 2Q� G ria c, MAILING ADDRESS E-MAIL CONTRACTOR 1 7, © %fin !'I've;- Dr,VR, CIT,Y n�1 L�� STATFN ZIP 6., y FAX WA STATE CONTRACTOR'S LICENSE# V•['14EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# / / NAME PRIMARY PHONE Ryan Ray, Kennedy/Jenks Consultants (253) 835-6400 MAILING APPLICANT 32001 32nd Avenue South, Suite 100 ryannrray@kennedyjenks.com CITY STATE Z8 O 0 1 FAX Federal Way WA (253) 952-3435 PROJECT CONTACT StaY PHONE n French, LWSD (253) 946-5410 (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence 31623 1st Avenue South sfrench@lakehaven.org concerning this application) CITY STATE ZIP FAX Federal Way WA 98003 NAME PROJECT FINANCING ID OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE: f� DATE April 4, 2017 PRINT NAME: Stan French Bulletin#100—January 29,2016 Page 1 of 2 k:\Handouts\Permit Application VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS(commerelaq BOILERS FURNACES HOT WATER TANKS(cas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT $ Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. BATHTUBS(or Tub/shower Combo) LAVS(Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS K schen/utility) WATER HEATERS(Electric HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS None LWSD LWSD EXISTING/PREVIOUS USE LOT SIZE(Iu Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? 133294 ❑Yes X No ❑Yes XI No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMEN FIRST FLOOR(or Mobile Home) SECOND I LOOR COVERED ENTRY DECK GARAGE ❑ CARPORT ❑ OTHER(cam, ._ EXISTING PROPOSED TOTAL Area Totals **taw HOMES OW" J ESTIMATED SELLING PRICE$ #OF BEDROOMS COMMERCIAL—NEW/ADDITION AREA DESCRIPTION Area m Occupancy Groups) Construction #of Additional Information Square Feet Type Stories Nsw Bunansa Outdoor concrete ADDITION 430 NA NA NA slab/foundation COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area m Occupancy Group(s) Construction #of Additional Information Square FeetType Stories TOTAL BUILDING TENANT AREA ONLY PROJECT AREA ONLY Bulletin#100—January 29,2016 Page 2 of 2 k:\Handouts\Pennit Application