17-103992 Electrical City of Federal Way Permit #:17-103992-00-EL Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 � ' Inspection Request Line: (253) 835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: ELLENOS YOGURT WAREHOUSE Project Address: 34114 21ST AVE S Parcel Number: 212104 9033 Project Description: 200A 480Vac 3Ph Feeder for Process MCC &equipment. Owner Applicant Contractor SCHINDLER FAMILY LIMITED DONLEY ZWARTCUTTER ELECTRIC LLC CUTTER ELECTRIC LLC PARTNERSHIP 8614 S 222ND ST CUTTEEL933JS(4/10/19) C/O STEPHEN K USSEEUX,JR. KENT WA 98032 902 S 10TH ST 8614 S 222ND ST TACOMA WA 98405 KENT WA 98032 Additional Permit Information Is this an Online or O.T.C.application'? Yes /// s 41CetriC F nir A� Alt. Srvc/Feeder 0 to 200 ami 1 PERMIT EXPIRES Friday, 17 August,2018 Permit Issued on Thursday,August 17,2017 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: ' DATE INSPECTOR AREA AND TYPE OF INSPECTION 1 I13I17 Vag Pk✓{-ea( X11. - Cvwkycrosc r) 1r46 AV Cc, lir4kJt S;wti-1 1 164,4 Pte} Wast*a Ute. . _ 11-(l t I n Fowl SollatA•cl VPD G417444 + Pit c . 1 1-4-1 14' v ‘76444",5 r• �1._14 pv►.fwt + go i 14 u vksw.-i-. — • • - THIS CARD IS TO REMAIN ON-SITE Federal Way Construction Inspection Record y INSPECTION REQUESTS: (253)835-3050 PERMIT#: 17 103992 00 Address: 34114 21ST AVE S Project: SCHINDLER FAMILY LIMITED PA FEDERAL WAY WA 98003-8984 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. e ® UFER Ground(4295) ® Ditch cover(4030) ® Slab/Concrete Floor(4255) Approved Approved Approved to place concrete By Date By Date By Date ❑ Pool Bonding(4195) ,® Temporary Power(4275) ® Service(4235) , Approved Approved Approved `By Date By Date By Date ® Feeders/Sub-panels(4045) ® Rough Electrical(4225) ® Ceiling Cover(4020) Approved Approved Approved ,. -----7-7----' Date ( 2 -Zp- (7 By Date By Date 0 Final-Electrical(4055) Approved By Q__c,, ,,%_: Date L\ _L..)z Rough Electrical0 Final Electrical CI Right of Way Approved Approved Approved By Date % By Date %By Date RESUBMITTED MAR 2 6 2018 COMMUNE EVEL W0PMENT Ellenos Real Greek, LLC Bob Klein 34114 21st Ave S Federal Way, WA 98003-8984 M1gw "`TF Department of Labor and Industries INSPECTION DATE EXPIRATION DATE 4 y Specialty Compliance Services 01/29/2018 01/26/2020 _ P.O. Box 44410,Olympia,WA 98504-4410 SPECIFIC PLANT LOCATION STATE NUMBER ' `yCERTIFICATE OF INSPECTION Boiler Room 05029-18W H�1tl° 0 ,LOCATION OF OBJECT OBJECT INFORMATION I Other# Ellenos Real Greek, LLC NB# 805811 34114 21st Ave S MANUFACTURER US Steel Fab Federal Way, WA 98003-8984 TYPE AT USE Storage SV SETTING 165 YEAR BUILT 2016 INSPECTOR Michael Low INSP. EMPLOYER State of Washington Post this certificate in a conspicuous place in the room containing the object. It must be available for viewing. This certificate is not valid unless the invoice has been paid. The Object shall not be operated at a pressure in excess of that shown. Notify the State of Washington, Department of Labor and Industries at 360- 902-5272 or 5273 or your insurance carrier 60 days prior to the expiration date. It is a violation of WAC 296-104-701 to operate the object without a valid insoection certificate posted near the obiect. .G?'T'_f Department of Labor and Industries INSPECTION DATE EXPIRATION DATE ` Specialty Compliance Services 01/29/2018 01/26/2020 ^f P.O.Box 44410,Olympia,WA 98504-4410SPECIFIC PLANT LOCATION STATE NUMBER "t CERTIFICATE OF INSPECTION Boiler Room 05030-18W LOCATION OF OBJECT OBJECT INFORMATION Other# Ellenos Real Greek, LLC NB# 278049 34114 21st Ave S MANUFACTURER WESSELS Federal Way, WA 98003-8984 TYPE EXP TK USE Storage SV SETTING 150 YEAR BUILT 2017 INSPECTOR Michael Low INSP. EMPLOYER State of Washington Post this certificate in a conspicuous place in the room containing the object. It must be available for viewing. This certificate is not valid unless the invoice has been paid. The Object shall not be operated at a pressure in excess of that shown. Notify the State of Washington, Department of Labor and Industries at 360- 902-5272 or 5273 or your insurance carrier 60 days prior to the expiration date. It is a violation of WAC 296-104-701 to operate the object without a valid inspection certificate posted near the object. Tire. INSPECTION DATE EXPIRATION DATE ��:` Department of Labor and Industries d Specialty Compliance Services 01/29/2018 01/26/2020 P.O.Box 44410,Olympia,WA 98504-4410 SPECIFIC PLANT LOCATION STATE NUMBER r '''-tSry r'' CERTIFICATE OF INSPECTION Boiler Room 05031-18W ,. LOCATION OF OBJECT OBJECT INFORMATION Other# 17.PGT550.112.0964 Ellenos Real Greek, LLC NB# 276709 34114 21st Ave S MANUFACTURER Lochinvar Federal Way, WA 98003-8984 TYPE FTBLR USE H W Heat SV SETTING 50 YEAR BUILT 2017 INSPECTOR Michael Low INSP. EMPLOYER State of Washington Post this certificate in a conspicuous place in the room containing the object. It must be available for viewing. This certificate is not valid unless the invoice has been paid. The Object shall not be operated at a pressure in excess of that shown. Notify the State of Washington,Department of Labor and Industries at 360- 902-5272 or 5273 or your insurance carrier 60 days prior to the expiration date. It is a violation of WAC 296-104-701 to operate the object without a valid inspection certificate posted near the obiect. TA,t. Department of Labor and Industries INSPECTION DATE EXPIRATION DATE Specialty Compliance Services 01/29/2018 01/26/2019 P.O. Box 44410,Olympia,WA 98504-4410 SPECIFIC PLANT LOCATION STATE NUMBER -i, 9 CERTIFICATE OF INSPECTION Boiler Room 05032-18W LOCATION OF OBJECT OBJECT INFORMATION Other# 03796-1-1 Ellenos Real Greek, LLC NB# 13118 34114 21st Ave S MANUFACTURER Cleaver Brooks Federal Way, WA 98003-8984 TYPE FTBLR USE Steam SV SETTING 150 YEAR BUILT 2010 INSPECTOR Michael Low INSP. EMPLOYER State of Washington Post this certificate in a conspicuous place in the room containing the object. It must be available for viewing. This certificate is not valid unless the invoice has been paid. The Object shall not be operated at a pressure in excess of that shown. Notify the State of Washington,Department of Labor and Industries at 360- 902-5272 or 5273 or your insurance carrier 60 days prior to the expiration date. It is a violation of WAC 296-104-701 to operate the object without a valid inspection certificate posted near the obiect. ,''"`r4 Department of Labor and Industries INSPECTION DATE EXPIRATION DATE Specialty Compliance Services 01/29/2018 01/26/2019 P.O.Box 44410,Olympia,WA 98504-4410 SPECIFIC PLANT LOCATION STATE NUMBER ?'?'<<' , CERTIFICATE OF INSPECTION Boiler Room 05033-18W LOCATION OF OBJECT OBJECT INFORMATION Other# 1602100510041 Ellenos Real Greek, LLC NB# 15738 34114 21st Ave S MANUFACTURER Cleaver Brooks Federal Way, WA 98003-8984 TYPE FTBLR USE Steam SV SETTING 150 YEAR BUILT 2015 INSPECTOR Michael Low INSP. EMPLOYER State of Washington Post this certificate in a conspicuous place in the room containing the object. It must be available for viewing. This certificate is not valid unless the invoice has been paid. The Object shall not be operated at a pressure in excess of that shown. Notify the State of Washington,Department of Labor and Industries at 360- 902-5272 or 5273 or your insurance carrier 60 days prior to the expiration date. It is a violation of WAC 296-104-701 to operate the object without a valid inspection certificate posted near the obiect. 4' ' SOS 3 - 00 tntertek Total Quality.Assured. RESUBMITTED MAR 2 6 2018 DCOM U DEVELOPMENT Y Systems Interface, Inc . vd SCOPE OF WORK FIELD EVALUATION—SYSTEMS INTERFACE, INC. MODIFIED INDUSTRIAL CONTROL PANELS REPORT NUMBER 103430634FLW-001 ISSUE DATE 19-March-2018 410 PAGES 10 DOCUMENT CONTROL NUMBER RT-R-AMER-Insp-3319 © 2017 INTERTEK tntCrtek 22887 NE Townsend Way — �--— Fairview OR 97024 USA Total Quality.Assured. Telephone: +1(503)676-2311 Facsimile: +1(503)676-2350 FIELD EVALUATION REPORT www.intertek.com Report No.: 103430634FLW-0011 Date: 19-March-2018 Mr Larry Bradford Telephone:425-492-8414 Systems Interface, Inc. Email: LDBradfordPsystems-interface.con 10802 47th Ave West Mukilteo WA 98275 Reference: Intertek Project Number G103430634 Subject: Intertek Field Evaluation Report of modified Industrial Control Panels Dear Mr Bradford, This report provides the results of the field evaluation that was conducted on your above referenced equipment to the requirements contained in the following standards: • UL 508A Standard for Safety Industrial Control Panels, 2nd Ed, Rev 32March2017 • With reference to the National Electrical Code (NEC®) NFPA 70 2017 Edition The evaluation was authorized by proposal number Qu-00862154, dated 21-February-February. Our evaluation of the new, modified equipment took place on 6-March-2018 at the Ellenos facility,34114 21st Ave. S, Federal Way WA. The Industrial Control Panels have been investigated to the Standard(s) indicated above as far as practical in the field and was found to be in essential compliance with those requirements. The equipment was labeled with our serialized Field Evaluation Label upon completion of our evaluation as noted in the details section of our report. If you have any questions, please feel free to contact us at your convenience. We are looking forward for future opportunities to work together. In Charge of Testing: 01(106+( Evaluator Christine Porter Title Field Evaluations/Codes & Standards Trainer cc Office Intertek Portland AHJ Joseph Szpek, Matt Becker, or Chuck Wilson Phone 206-841-1707 Title Electrical Inspectors,City of Federal Way Email Email nerrnitcenter ritvoffPriPr € ay.co— This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.The observations and test results in this report are relevant only to the sample tested.This report by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Version:02 May-2017 Page 2 of 10 GFT-OP-10b • Intertek Total Quality.Assured. FIELD EVALUATION REPORT FOR SYSTEMS INTERFACE, INC. Report No.: 103430634FLW-001 Date: 19-March-2018 Rendered To: Systems Interface, Inc. 10802 47th Ave West Mukilteo WA 98275 Contact: Larry Bradford Phone:425-492-8414 Email: LDBradford@systems-interface.com Performed By: Intertek Testing Services NA, Inc. 22887 NE Townsend Way Fairview OR 97024 USA Tel: (503) 676-2311 Fax: (503)2350 Products Covered: Industrial Control Panels Inspection Site: Ellenos 34114 21st Ave. South Federal Way WA Results The equipment noted in this Report has been investigated and, as far as practical in the field, has been found to be essentially in compliance with the requirements of the following standards: • UL 508A Standard for Safety Industrial Control Panels, 2nd Ed, Rev 32March2017 • with reference to the National Electrical Code (NEC®) NFPA 70 2017 Edition Complete information and details of the investigation are on file at this office.The installation methods and final approvals at the installed site are the responsibility of the Local Inspection Authority Having Jurisdiction (AHJ). Please note:this Report does not represent authorization for the use of the Intertek ETL Listing Mark. In Charge of Testing: Approved by: UhQ,l64.1KX.,'VOiMVA_Q Q Christine Porter David M Hill �'w�"� Field Evaluations/Codes &Standards Trainer Field Evaluations/Codes &Standards Trainer Intertek ETL—NFLP West Intertek ETL- NFLP West Christine norterPintprtpl d!ave.hill@intertek.cor. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this report.Only the Client is authorized to permit copying or distribution of this report and then only in its entirety.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.The observations and test results in this report are relevant only to the sample tested.This report by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Version: 14-March-2017 Page 3 of 10 GFT-OP-10b FIELD EVALUATION REPORT FOR SYSTEMS INTERFACE, INC. Report No.: 103430634FLW-001 Date: 19-March-2018 INDEX SECTION NAMES PAGE 2 Scope 5 3 Product Evaluation Procedures 5 3.1 Standards 5 3.2 Visual Inspection 5 3.3 Product Type Testing 7 3.4 Resolution of Discrepancies 7 3.5 Technical Report 7 4 Product(s) Evaluated 7 4.1 Equipment Identification and Field Label Number(s) 7 4.2 Conditions of Use 8 4.3 Schematics and Photographs 8 Version: 14-March-2017 Page 4 of 10 GFT-OP-10b FIELD EVALUATION REPORT FOR SYSTEMS INTERFACE, INC. Report No.: 103430634FLW-001 Date: 19-March-2018 SCOPE This Final Field Evaluation Report provides the results of the evaluation of non-certified or other special equipment described in this report. The purpose of these inspections is to provide a review of the electrical constructions of the equipment and provide a degree of assurance that the constructions comply with the requirements of the appropriate standards. The evaluation is based upon a combination of the essential requirements in the identified product standard and the recommended practices for evaluations as covered in Chapters 5 and 6 of NFPA 791 Recommended Practices for Field Evaluations This evaluation is limited to the equipment itself and is not specifically intended to identify issues with the supply wiring other than the rated capacity and method of termination to the equipment. The installation methods and final acceptability at the installation site are the responsibility of the Authority Having Jurisdiction. PRODUCT EVALUATION PROCEDURES 3.1 Standards: The standards used in our evaluations are the applicable American National Standards Institute (ANSI) standard, National Fire Protection Association (NFPA) standard, other Approved product standards, or Approved State or local ordinances. 3.2 Visual Inspection:A visual inspection of the equipment was conducted,comparing product construction to requirements of the applicable standard.The evaluation included directly connected loads to the equipment identified in the report. Complete inspection records are on file at Intertek. Suitability for Use and Location:The equipment was found to be suitable for the indoor, dry location. There were no adverse environmental conditions found that would impair the proper operation and use of the equipment.The equipment was suitably protected from physical damage. Condition of the equipment:The equipment was in satisfactory condition. No components were found to be damaged in a manner that impacted performance and operation. Metallic parts of the equipment had suitable corrosion protection. Nonmetallic parts were not likely to suffer deterioration or create a fire hazard. Access and Workspace clearances: Access was provided about all electrical equipment to permit ready and safe operation and maintenance of the equipment. The work space clearances for electrical enclosures likely to require examination, adjustment, servicing,or maintenance while energized were provided in compliance with the NEC° Section 110.26 and the applicable standard. Exposed Parts:Adequate spacings, creepages, and clearances were provided between live parts of opposite polarity and noncurrent-carrying metallic parts,or suitable barriers were provided. Where live parts were exposed suitable guards or barriers were provided. Separation: Electrical conductor insulations of different voltage systems were found to be either rated for the highest voltage or were separated by suitable barriers. Electrical wiring was separated from other utilities such as oil and water by suitable barriers. Version: 14-March-2017 Page 5 of 10 GFT-OP-10b FIELD EVALUATION REPORT FOR SYSTEMS INTERFACE, INC. Report No.: 103430634FLW-001 Date: 19-March-2018 Grounding and Bonding: All required noncurrent-carrying metallic parts of the equipment have been determined to be suitably bonded to the supply equipment grounding conductor.The equipment grounding conductors and bonding jumpers were terminated properly. Equipment grounding conductors and bonding jumpers served no other function. Internal Overcurrent Protection:The type and ratings of the overcurrent protection provided within the equipment was suitable for the conductors and loads served. External Overcurrent Protection:The rating of the overcurrent protection from the source to the equipment was verified as stated below: Type of OCD Rating AIC circuit breakers Various per ratings of each panel at least 10kA The determination of the amount of available fault current of the electrical supply delivery system to the equipment was not a part of this evaluation. Conductors:All equipment wiring was found to be certified for use, accepted by testing,or verified as acceptable. Conductors were used within the applicable voltage and temperature ratings. Conductor sizes were in accordance with the allowable ampacities given in the standards identified in this report. Wiring Methods:The equipment wiring methods were properly secured, supported, and routed away from physical damage.The wiring methods utilized in and one the equipment provided the required separation and protection from live parts as required by the standards noted in this report. Field Wiring Terminations:All field wiring terminals were identified and were suitable for the conductor type,stranding, and ampacity of conductors being terminated.Terminals suitable for more than one conductor were marked. Guarding of Equipment:The evaluated equipment identified in this report has been provided with suitable covers,enclosures,and guards as required by the standards used for the evaluation. Fastenings used for covers were in accordance with the standard. Hinged doors are able to open at least 90°. Swing-out panels if used were able to open at least 110°. Labels were applied on the equipment where required by the standard apprising the users of the physical hazards associated with the equipment. Markings:Where applicable the required Caution, Warning,and Danger markings were provided on the equipment. Complete nameplates were provided as required by the standard. General Engineering Practices:The equipment was constructed to meet the requirements of the standards identified in this report.The equipment was constructed in a workmanlike fashion. Other Comments:This equipment was evaluated for use at the installed site noted on the cover page of this report only. Any modifications or moving of the subject equipment requires a re-evaluation. Version: 14-March-2017 Page 6 of 10 GFT-OP-10b FIELD EVALUATION REPORT FOR SYSTEMS INTERFACE, INC. Report No.: 103430634FLW-001 Date: 19-March-2018 3.3 Product Type Testing:The electrical tests conducted on the equipment followed the standards identified in this report as closely as practicable, considering the limits of a non-laboratory setting and the need for the equipment to perform all required functions after the tests.The following non-destructive tests were conducted with satisfactory results.Test results are on file at the Intertek office. • Grounding Continuity 3.4 Resolution of Deficiencies: Any deficiencies identified on the subject equipment during the evaluation and testing process are noted in the table below. Methods of resolution are reviewed, agreed upon, and verified by Intertek before the ETL Label was applied. Deficiency Approved Resolution None N/A 3.5 Technical Report: Upon completion of the Field Evaluation and application of the Field Evaluation Label, this final technical report was prepared and issued to Systems Interface, Inc., and to the local Authority Having Jurisdiction (AHJ) for the installed site: Joseph Szpek, Matt Becker, or Chuck Wilson, Electrical Inspectors. PRODUCTS EVALUATED 4.1 Equipment Identification and Field Label Number: Field Evaluation of multiple control panels that were manufactured in Poland but rewired to be compliance with UL 508A by a UL 508A panel shop. The panels were modified in the field at the installation site which meant the panel shop could not apply a Listing Mark. The modifications consisted of replacing the control transformers with ones that were listed and to apply a new nameplate that provides the total FLA, largest motor, enclosure type rating, a SCCR marking, and tightening torque values as well as the temperature rating for ampacity use for field installed conductors. Manufacturer Model Serial No Ratings ETL No Systems Interface 212 KS S18B25C 2HP 480V 30 60Hz, 9A FLN 433916 Systems Interface 246KSP S18B25A 5HP 480V 30 60Hz, 22.1A FLN 433917 Systems Interface 2EZHS S18B25E 1HP 480V 30 60Hz, 30A FLN 433918 Systems Interface CIP 3901 S18B25D 3HP 480V 30 60Hz, 25A FLN 433919 Systems Interface T800S TL S18B25B 10HP 480V 30 60Hz,35A FLN 433920 In addition to the modified industrial control panels,there were four motors with gear boxes located on top of vats.The motors are built to the MG-1 standard, have complete nameplates, are cord and plug connected by pin and sleeve receptacles that are switch rated, and are controlled by a listed industrial Control panel. In accordance with WAC 296-46B-430 Motors,motor-circuits,and controllers.there is no requirement for motors to be identified for use or listed/field evaluated by a laboratory if it has been determined that the motors are built to the NEMA standard. Since these are also wired to and controlled by a listed Industrial Control panel no further action was taken. Version: 14-March-2017 Page 7 of 10 GFT-OP-10b FIELD EVALUATION REPORT FOR SYSTEMS INTERFACE, INC. Report No.: 103430634FLW-001 Date: 19-March-2018 4.2 Conditions of Use and Acceptability: This product is intended for use and installation in a non-classified (non-hazardous) location and for connection to the appropriately sized branch circuit. The installation methods and final acceptability at the installation site are the responsibility of the Authority Having Jurisdiction. 4.3 Schematics and Photographs: Schematics or drawings representative of the equipment were provided to Intertek for review during the evaluation of this equipment. The photographs on the following pages are representative of the equipment evaluated. Additional photographs taken are on file in the Intertek project folder. 410 _ r t r, _ f _ sl _ • F mill 16 'hoto 1 Granola and lid inserter . . •t• • • VIII • I " • M • • • 1 - VS it Systems Interface /11: 114t1\ N eftilli1111( 4H' IIIPI E' Ct� �Rf •£ SEAMA E BlB:ft 1„eua,.1 �ctrFPSE„E rf �ivssr.F . r+ .j, 0.kl LWS,'MAPS; - ':--N2 '.'.,'",,:..'4.1,4; aNL n>v,cmw• liko GSEEegaa,•RN•ff” n r .T` - BCCA*AIN6,0l 1r►Lwc 'hoto 3 Lower section of same control panel Photo 4 Typical of labels applied Version: 14-March-2017 Page 8 of 10 GFT-OP-10b FIELD EVALUATION REPORT FOR SYSTEMS INTERFACE, INC. Report No.: 103430634FLW-001 Date: 19-March-2018 w s ,v, i54ç i twitii, „„ k.* '.1..4,10,13i ; : I * i -I 'it V ... 4—r.w, , ` j0,444,.. 4� .. Photo 5 CIP panel Photo 6 box erector packaging panel 11 IIII 111111 a r. 74 ' K i �{ .t t"R '. __ t �. a , 4 1 41'�if , „ ,. �s d 'e :t,7-:* \\ 11-. '-- ` , Photo 7 crate and bucket cleaning line panel 'hoto 8 Motor w/gear box at top of large vats,cord onnected,Typical Version: 14-March-2017 Page 9 of 10 GFT-OP-10b FIELD EVALUATION REPORT FOR SYSTEMS INTERFACE, INC. Report No.: 103430634FLW-001 Date: 19-March-2018 .....---_,-_,---i--: ;'i., fit -213 _`" - tI __ . ° .141# ''' '' . +' a • a - r rr r " \ ti � � 1 Photo 9 Four vats w/motors Photo 10 Motor Nameplate(typical) 2.2KW, 60Hz, 400V, 4.09A, 740RPM, COSO .80, 1E2 84.3%, IP 55, 20k.. ammil P iFi--'-Ei4LUlf. ® or 1 nn r i i fir` C1 ',./., 1 Ott n,— `d / /' ' . , \ I AA, v lk Photo 11 Listed Control Panel for the vat motors Version: 14-March-2017 Page 10 of 10 GFT-OP-10b