Loading...
17-106080 y Building- Commercial I ° City of Federal Way A +°I i . -. Permit #:17-106080-00-CO Community Development Dept. 33325 8th Ave S "g Federal Way,WA 98003 Inspection Request Line: (253) 835-3050 Ph:(253)835-2607 Fax(253)835-2609 Project Name: EMERALD PROFESSIONAL CONDOMINIUM Project Address: 710 S 348TH ST Parcel Number:233145 0020 Project Description: ADD-Installation of(9)Helical Piles to stabilize foundation. Owner Applicant Contractor Lender SHELTON INVESTMENT GROUP R&R FOUNDATION R&R FOUNDATION OWNER IS LENDER 900 S 336TH ST SPECIALISTS SPECIALISTS FEDERAL WAY,WA 98003 7704 176TH ST E 7704 176TH ST E SNOHOMISH WA 98296 SNOHOMISH WA 98296 • Census Category: 437- Commercial alt/add/conversion Includes: J #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area(sq.ft.) Additional Permit Information Mechanical to be Included9 No Plumbing Work Valuation" 0 Mechanical Work Valuation9 0 Number of Stories 1 Is this an Online or O.T.C.application9 No Permit for Building Shell Only" No Plumbing to be Included9 No Total Valuation: 16,192.00 4-4 CONDITIONS: SPECIAL INSPECTION AGAENCY OR EOR REQUIRED TO BE ON SITE DURING THE ENTIRE TIME HELICAL PILES ARE INSTALLED. FINAL REPORT REQUIRED TO AHJ PERMIT EXPIRES Monday,9 July,2018 Permit Issued on Wednesday,January 10,2018 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy an the use will be' accordance with the laws, rules and regulations of the State of ashi .!/In the City of Federal Way. Owner or agent: Cf�C 1 (/ Date: /7/07/ -14_,t THIS CARD IS TO REMAIN ON-SITE Federal WaConstruction Inspection Record y INSPECTION REQUESTS: (253)835-3050 PERMIT#: 17 106080 00 Address: 710 S 348TH ST Bldg B Project: SHELTON INVESTMENT GROUP FEDERAL WAY WA 98003-7042 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ❑ Initial Erosion Control(4365) p Footings/Setback(4110) Q Foundation Wall(4115) To be done PRIOR to breaking ground Approved to place concrete Approved to place concrete By Date By Date By Date ® Drainage/Downspout(4040) CC Re-steel(4215) ❑ Slab/Concrete Floor(4255) Approved to backfill Approved pproved to place concrete or grout Approved to place concrete By Date By Date By Date O Underfloor Framing(4285) ® Floor Sheathing(4105) 0 Shear Walls(4245) Approved to sheath floor Approved to install flooring Approved to install siding By Date By Date By Date 10 Roof Sheathing(4220) El Fire/Draft Stops(4095) CI Interim Erosion Control(4370) Approved to install roofing Approved Approved By Date By Date By Date [ Prior to scheduling a Framing inspection; 13 Framing(4120) CI Insulation(4150) Electrical,Plumbing&Mechanical Rough-in Approved to insulate Approved to install wallboard and Fire/Draft Stop inspections must be signed- off and approved. IBC 109.3.4 By Date By Date EC Gypsum Wallboard Nailing(4130) 111 Suspended Ceiling Grid(4265) t7 Final-S K F&R(4060) Approved to install mud&tape Approved to drop tile Approved By Date By Date By Date Ci Final Erosion Control(4375) ID Final-Building(4050) Approved Approved By Date By C.v...,1 Date 2„ '�-i ❑ Rough Electrical ❑ Final Electrical ❑ Right of Way Approved Approved Approved By Date By Date By Date Docusign Envelope ID:60870EBA-4566-4F6B-8A68-A90BB540729F • STARK 4001 Main Street, Suite 305 FOUNDATIONS Vancouver WA, 98663 P: 360.566.7343 torrTt STRUCTURAL CALCULATIONS PREPARED FOR STEVE SHELTON FOR FOUNDATION REPAIR 710 S 348TH STREET FEDERAL WAY, WA O DTl PROJECT NUMBER: 17.068.RFS > O 0 171 2015 IBC 1704: Special Inspections: DATE: DECEMBER 20, 2017 rn m u The owner or the registered design professional in PROJECT MANAGER: DANIEL STARK, P.E. c�i> * responsible charge acting as the owner's agent shall employ one or more special inspectors to provide n, z inspections during construction on the types of work KIAIE L jyr y N.) m �. D co O listed under 2015 IBC Section 1704. Special ~� of waste�r inspection agencies shall be approved by the �ao Washington Association of Building Officials ti - p c o (WABO) www.wabo.org. if CD CD 40643 z 0 SPECIAL INSPECTION REQUIRED EXPIRES : JULY 13, 2018 O0 FOR THE INSPECTIN OF ALL cn PILES PER 2015 IBC TABLE 1705.7 APPROVED PArt- CiTy t> e(ieNt poi -of bui(411 ) pr Date 1 �' r n kit( ytr - of A •c1M( iris ec"rotil aNiy obre ►n A-rouu 1 boc-t^ yhe,4-ct i oil RECEIVED SPecvl ��5�� vTia/J �c�� s Gios►r, (t+fCC - ''O) Miro( r, ( / r(( DEC 2 6 2017 ff�'mt "( `'4 te,lt c¢! 1 ISS CIlYOFFEDERALWAY ._r COMMUNf7Y DEVELOPMENT W I4 a1�'(X( r{( ArproVt d plonk• DocuSign Envelope ID:60870EBA-4566-4F6B-8A68-A90BB540729F • STARK 4001 Main Street, Suite 305 FOUNDATIONS Vancouver WA, 98663 P: 360.566.7343 December 20, 2017 SFI Project No.: 17.068.RFS Steve Shelton 710 S 348th Street Federal Way, WA 98002 Re: 710 S 348th Street, Federal Way, Washington PROJECT BACKGROUND We understand that the structure is a commercial building and has experienced settlement at the southeast corner of the structure. A recent floor level survey (attached) indicates as much as 3 7/8"of differential settlement may have occurred. It is our understanding that (9) 2 7/8"diameter helical piers have been proposed to help provide additional foundation support. v .'r V 4,' rl +• _ % *. ..:ice • . ° "'0'.. .. -4,.,, I. . -,) i "sr ,„>" t,, : -.. ,‘• ,.,' , 4i t/ �:, Image 1: South Elevation 41\S• STARK 4001 Main Street, Suite 305 FOUNDATIONS Vancouver WA, 98663 P: 360.566.7343 GEOLOGIC SETTING The existing structure is located in Federal Way, Washington. The geologic structure in the area is comprised of gravelly sandy loam and the site is relatively flat. It is our opinion that the settlement is a result of improper foundation drainage, resulting in localized settlement. We believe that suitable support can be achieved by installing helical and/or push piers. SUMMARY The ultimate load requirement for the helical piers is 30,000 lbs, and based on the geologic setting, we expect the piers to achieve adequate capacity at approximately 15—25 feet. We recommend that the piers with a 2 7/8"shaft and 10"diameter helix plate be installed to a minimum depth of 10-ft and a minimum installation torque of 3,333 ft-lbs, or refusal. Please give our office a call if you have any questions or need further assistance. Regards, 01EL WA y -T �� —`ti 'T 4,- iliti„,:. 0-1,.% . �i,of w.asy�� ,, c� Daniel Stark, P.E. 4-;- :;41 ,,/ Stark Foundations, Inc. F -o ` s, ' 4, �p 40643 V SEC/STERE SSIONAL ''' EXPIRES : JULY 13, 2018 DocuSign Envelope ID:60870EBA-4566-4F6B-8A68-A90BB540729F Monday, November 20, 2017 Foundation Specialists SCOPE OF WORK Crew will install Helical Piles and lift house to maximum practical recovery. Crew will drive Piles or Piers to a maximum depth of 25', after there will be a $20 per foot charge per pile. Customer is responsible for permit and engineering. LEVEL SURVEY • N 4' 0o 1 4' _ 2 7,8 2 C - -1 1/2 3 C' o . CO -2 1/8 -3/4 cv;) -1/8 4 -2 3/4 5C 6 -3 7/8 -1 1/4 -541' 0 7 8 9 Docu$ign Envelope ID:60870EBA-4566-4F6B-8A68-A90BB540729F Date: 20-Dec-17 40STARK W Foundation Repair Designed by: NDS FOUNDATIONS C 710 S 348th Street rg Federal Way, WA Job No.: 17.068.RFS Design Criteria Code(s): International Building Code(IBC)2015 ASCE 7-10 Design Loads: Dead: Soil: Roof= 15 psf Allow Lateral Bearing Pressure = 100 psf/ft (IBC Table 1806.2) Brick Veneer= 45 psf Active Pressure = 60 psf/ft Second Floor= 15 psf First Floor= 15 psf Walls = 45 psf(brick) 8"Foundation Wall = 100 psf Soil = 110 psf Live: Roof(snow) = 25 psf Third Floor= 0 psf Second Floor= 40 psf First Floor= 40 psf Wind: (not applicable) Exposure = C Risk Category = II Wind Speed,V = 120 mph K�,= 1.0 Gust Effect Factor,G= 0.85 K. = 0.85 Internal Pressure Coefficient,GCp, = -0.18 K,= 0.98 External Pressure Coefficient,Cp= 0.8 Height, h,= 30 ft Design Wind Pressure: Design Load Combo = D + 0.6W where: p„,= q,(GCp-GC ;) w= 0.6 q,= 0.00256K,KtKdV' Therefore: q,= 30.7 psf pw= 26.4 psf Factored Wind Pressure, p'w= 15.8 psf(say 16 psf) DocuSign Envelope ID:60870EBA-4566-4F6B-8A68-A90BB540729F Date: 20-Dec-17 41,4H STARK V Foundation Repair Designed by: NDS FOUNDATIONS ^^ 710 S 348th Street w Federal Way, WA O. Job No.: 17.068.RFS Helical Pier Design Vertical Design Loads: Tributary Widths: Roof= 15 ft > 225 plf Brick Veneer= 0 ft > 0 plf Second Floor= 0 ft > 0 plf First Floor= 6 ft > 90 plf Walls= 15 ft > 675 plf Foundation Wall (height) = 4 ft > 400 plf Soil (height) = 3 ft > 495 plf EDL= 1885 plf Live: Roof(snow) = 15 ft > 375 plf Third Floor= 0 ft > 0 plf Second Floor= 0 ft > 0 plf First Floor= 6 ft > 240 plf ELL= 615 plf Max Pier Spacing = 6 ft Pier Working Loads: PDL= 11310 lbs 0.75*PLL= 2768 lbs PTL= 14078 lbs Pier Design: Pier Type Helical Pier Bracket'2.88NCB L. Bracket Capacity = 45000 lbs Therefore ok Reference ICC ESR-1854, Table 1-Foundation Mechanical Ratings of Brackets(Appendix A) Shaft Diameter 2.875" jr Installation Torque,T: Quit= 2(PTL) Quit= Kt(T) where Kt= helix torque factor(ft-1) Shaft Dia Kt 28155 lbs according to the following table: 2.375 10 2.875 9 3.5 7 Therefore,T= Q,it/Kt Allowable TSHAFT= 8200 ft-lbs Therefore ok 4.5 6 3128 ft-lbs DocuSign Envelope ID:60870EBA-4566-4F6B-8A68-A90BB540729F • 265-0' \ � PROPERTY UNE 7 1f—f ---..„.................. NI 710 S 34811-i STREET FEDERAL WAY, WA 0 N \ \ S 348TH STREET O SITE.,PLAN EDQ r vis DocuSign Envelope ID:60870EBA-4566-4F6B-8A68-A90BB540729F • 15K • ul• 0 N. t• I NOTE: SEE FLOOR LEVEL Y• SURVEY FOR PLAN DIMENSIONS LEGEND of • INDICATES HEUCAL PIER & 10K UNFACTORED DESIGN LOAD (KIPS). SEE DTI_ 2 0 i+) UU. • • • • 3'-6, 15K 6'-6' 15K 6'-0' 15K OPARTIAL FOUNDATION REPAIR PLAN BACKFIL (E) GRADE 11=11. ._ E X E rAVII II=11-11 v p111EL WAS, of waste rv • � • - 4 • ) op -'' • ••' FOOTING BEYOND CHIP OUT POCKET IN (E) FOOTING j h,E40643� TYPE B BRACKET + FLUSH WIN FDN WALL. POCKET S C SEER c5 (PIERTECH P/N 2.88 NCB) WIDTH TO MATCH BRACKET WIDTH SIONAL 2 7/8'0 EXTENSIONS (5' OR 7') EXPIRES : JULY 13, 2018 (PIERTECH P/N 2.88-E5G OR 2.88-E7G) 2 7/8'0 X 7' LEAD W/ 10'0 HEUX NOTE: PILE EMBEDMENT SHALL BE (PIERTECH P/N 2.68-L710G) MIN INSTALLED PER THE TORQUE CORRELATION METHOD TO ACHIEVE 2X DESIGN LOAD NOTED ON 1� THE FOUNDATION PLAN. O2 7/8"0 HELICAL DETAIL vrK•-r I CITY O1 ` PERMIT APPLICATION Feder-i Way PERMIT CENTER•33325 8°M1 Avenue South+Federal Way,WA 98003-6325 253-835-2607+FAX 253-835-2609+permitcentertucitvoffederalwav.com PERMIT NUMBER_l 1._ 1 0 G O <P o _ c 0 TARGET DATE(��14- ' SITE ADDRESS Inur 1IO S 3`�gth St , federal vlok , Wa(�e.`_^ swTE/ , RECEIVED PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL e $1),182 2 3 3 1 4 5 . 0 0 1- 0 DEC 2 6 2017 TYPE OF PERMIT jil BUILDING 0 PLUMBING�'/) 0 MECHANICALA0 DEMOLITION 0 ENGINEERINGGINE0 FIRE PREVENTION NAME OF PROJECT e Slit 1 1 o n - h l o s 3�g (C7 CITY OF FEDERAL WAY ��11,i h q et Ali Calf 1 c4- b i 1 ; COMMUNITY DEVELOPMENT PROJECT DESCRIPTION O '�ck�4 Detailed description of work to be included on this permit only f Ew e.re...-0///0""1��( 'er 0\C-c.''.":,S NAME PRIMARY PHONB PROPERTY OWNER Shelton I nV-e4tyme,n-+ EI P Z53-3 D•"15'1) ,.;,'i-�� 1NG ADDNEBS�- .42.ti �'-0 E-MAIL IV.A`—yJ,u 'v(_'STATE ZIP --- may`/1K4tLWT//-VA✓■•` /1��— WAt�y-b-- q�l�V � ��J��\ (�P�-{14]-N�---_-'_. _-Vr.�(PJB-,../e_. NAME 1Q, YN�v �'on S ec O tSSts gal •i MAILING ADD�RIES y `(\� E-MAIL CONTRACTOR ``'� I�b�'Yl T� v� ( aledrAL rrspcGatllt .Com old-P I G WA STATE Dm 1al TO LICENSE e VIA ZIPamp, �✓�EXPIRATION A� Igloo 1p1� WAY BUSINESS SLICE YYY �a3�/1 NAME s l v-t) 1 1 PRIMARY PHONE APPLICANT MAILING ADDRESS E-MAIL CITY STA �r 'TEE I ZIP FAX PROJECT CONTACT NAME MT V l O' '1 G�'l evs PRIMARY PHONE I !The individual to receive and MAILING AD - ?D i1� ' ^� a I I ,�y,r E-MAIL respond to all correspondence acet rip "4/l,U�/I b U u'o concerning this application) CITY STATE ZIP FAX NAME PROJECT FINANCING IX OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (ROW 1927095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. �► s 'A SIGNATURE: �� ' / ;Ism'4144 DATE 1-1.1 W 12e0 t PRINT NAME:6I.l L 6 \ L Bulletin#100-January 29,2016 Page 1 of 2 k:Uiandouts\Permit Application VALUE AANICAL MECHANICAL PERMIT ti'pt w WORK Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS _ FANS _ GAS PIPE OUTLETS _ OTHER(Describe) AIR CONDITIONER _ FIREPLACE INSERTS HOODS Icommerrml BOILERS FURNACES _ HOT WATER TANKS icael COMPRESSORS _ GAS LOG SETS _ REFRIGERATION SYST DUCTING _ GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT N $ •Nf Indicate how many of each type offixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. BATHTUBS pr nn/Sno.erccrosq LAWS(NS°a sm.) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS _ URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS(Kitchen/way) WATER HEATERS(Orcinq HOSE BIBBS _ SUMPS _ WASHING MACHINES _ TOTAL RESTORES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS EXISTING/PREVIOUS USE LOT SIZE On Square Past) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Li Yes H No [1 Yes ❑ No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT FIRST FLOOR(or Mobile Home) SECOND FLOOR COVERED ENTRY DECK GARAGE ❑ CARPORT 7 OTHER(describe) Area Totals =SIT. PROPOSED TOTAL ."NEW HOMES OMT'* ESTIMATED SELLING PRICE$ #OF BEDROOMS COMMERCIAL—NEW/ADDITION AREA DESCRIPTION Area Occupancy Groups) Construction #of Additional Information Square Feet Type Stories NSW BUILDING ADDITION COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area Occupancy Group(s) Construction M of Additional Information Square FeetType Stories TOTAL BUILDING TENANT AREA ORLY PROJECT AREA ONLY Bulletin#100—January 29,2016 Page 2 of 2 k:\Handouts\Permit Application