Loading...
12-102582 • OJBuilding - Commercial City of Federal Way + Permit #: 12-102582-00-CO Community&Econon.Dev.Services � 33325 8th Ave S Federal Way,WA 98003 Ph:(253)835-2607 Fax:(253)835-2609 t: Inspection Request Line: (253)835-3050 Project Name: TEMPLO ALFA Y OMEGA CHURCH Project Address: 2020 S 314TH ST Parcel Number: 092104 9053 Project Description: TI-Relocate existing 1,440 square foot stage and add partition wall to create storage space. No plumbing or mechanical. Owner Applicant Contractor Lender TEMPLO ALFA Y OMEGA TEMPLO ALFA Y OMEGA TEMPLO ALFA Y OMEGA 810 SW 307TH ST 810 SW 307TH ST 810 SW 307TH ST FEDERAL WAY WA 98023 FEDERAL WAY WA 98023 FEDERAL WAY WA 98023 Census Category: 437 - Commercial alt/add/conversion Includes: #1 #2 #3 #4 Occupancy Class: A-3 Construction Type: Type V-B Occupancy Load: 1146 Floor Area(sq.ft.) 15,643 0 0 0 Additional Permit Information Existing Sprinkler System in Building? Yes Mechanical to be Included No Number of Stories 1 Permit for Building Shell Only? No Plumbing to be Included? No New/Additional Sq.Feet-Total 0 Occupancy#1 -Use Church Zoning Designation CC-F No Fixtures Associated With This Permit FIN Fi /42/14.o'L-* CONDITIONS: 1.This permit is approved for a congregation membership not to exceed 220 members plus up to 10 church staff(230 in total). PERMIT EXPIRES Tuesday, December 11, 2012 Permit Issued on Thursday, June 14, 2012 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the 's: will be in accordance with the laws, rules and regulations of the State of Washington ighnd the City of Federal Way. Owner or agent: 411111Date: / I '4 I lt 1Q-J\ OY s) 1/ THIS CARD IS TO MAIN ON-SITEf , CITY of �' Federal WayConstruction In ection Record INSPECTION REQUE TS: (253) 835-3050 PERMIT#: 12-102582-00-CO Address: 2020 S 314TH ST Project: TEMPLO ALFA Y OMEGA FEDERAL WAY, WA 98003-5475 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 SWM Precon Site Mtg(4400) Initial Erosion Control(4365) "0 Footings/Setback(4110) Approved To bi done prior to breaking ground Approved to place concrete By Date By Date By Date , Re-steel(4215) 0 Slab/Concrete Floor(4255) Underfloor Framing(4285) Approved to place concrete or grout Approved to place concrete Approved to sheath floor By Date By Date By Date / El Floor Sheathing(4105) Fire/Draft Stops(4095) El Interim Erosion Control(4370) Approved to install flooring Approved Approved By Date By Date By Date Framing(4120) Insulation (4150) nor to scheduling a Framing inspection; Electrical,Plumbing&Mechanical Rough-in and Approved to insulate Approved to install wallboard Fire/Draft Stop inspections must be signed-off and approved IBC 109.3.4 By Date By Date ..a s ,N✓G'.„.,6v:.. .,,,r..:.: -;;..•:::,tea L �-.. ❑Gypsum Wallboard Nailing(4130) El Suspended Ceiling Grid(4265) ❑ Final-Fire partment(4060) Approved to install mud&tape Approved to drop the Approved By Date By Date By Date o Final-Planning ❑ Final Erosion Control(4375) Final-Building(4050) Approved Approved /' Approved By Date By Date / Date/A-9.—/a_ 0 Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date DATE INSPECTOR AREA AND TYPE ( JNSPECTION ��_U- ( Z - � ( � - � � , � � � C . / n/� Fr' ____*___,I i . - ,,./,0 i, 5: .d;r2R-ga. , CITY or 0"k4A-- qER1vI IT Sh MF 100 ME PL DE EN FP Federal Wa COMMUNITY DEVELOPMENT E3-EIV E W P P L I C A T I O N 7 /C\ 253-835-2607.FAX 253-835-2609 _ / / . . J.F,1._,:,"'JUN 07 2012 SITE ADDRESS CM OF FEOEML WAY / ' ^ n SUITE/UNIT# a. c -e_r PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL li $ cc _F-:._ 09A / 0V - 90 S 3 l0 BUILDING ❑ PLUMBING ❑ MECHANICAL TYPE OF PERMIT ❑ DEMOLITION 0 ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT ' —�" , A^ it N� � ` (Tenant Name/Homeowner Last Name) ` v v\ \`�� � � �I j0 � PROJECT DESCRIPTION IQ_�L, R. �' 1 S l'1 4 ) `.i C , Detailed description of work to 6:W4 C., d— 1\.) Q.C.•A) O 1C4 D-^- . CC, 1 r be included on this permit only c'G'Qrtc ‘,, . 4—C,--Cip•-y . .-- NAME1 PRIMARY PHONE PROPERTY OWNER }tl_„ 'L "C C, °--- Q L ', MAILING ADDRESS E-MAIL CITY STATE ZIP VVV NAME 470 Q 0,66 � PHONEa�`s 3 5 6 (L U z MAILING ADDRESS(0) S + 1 E-MAIL (VX CONTRACTOR '2A3-2A (2 f` CI� STATE ZIP . t 2 1 FAX WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# / / NAME � � �y (" PHONE APPLICANT MAILING /L7/.,KESS , c ' -I E-MAIL CITY - �-- SA {TJ�(j�U,ZZII (J�,..(/���� FAX PROJECT CONTACT NAME J _ \ PHONE (The individual to receive and ,__.. 4-- 81-1,-x"..-411,, respond to all correspondence MAILING ADDRP,S.15 ' fo C-" , S A' , ,� ` E-MAIL concerning this application) � (� w CITcp___ .,0&,\ STATE 4 ZIP FAX ALTERNATE CONTACT NAME: W PHONE E-MAIL PROJECT FINANCING NAME Ai/ I /1V/ D OWNER-FINANCED Required value of$5,000 or more (RCW 19.27.095) MAILING ADDRESS,CI Y,STATE,ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree t. hold harmless the City of Federal Way as to arty claim(including costs, expenses, and attorneys'fees incurred in the investigation a • defense of su claim), which may be made by any person, including the undersigned, and filed against the city, but only where su laim arisesof the reliance of the city, including its officers and employees, upon the accuracy of the information supplie e city as a • of this application. 1�j'� SIGNATURE: DATE-....._ /is i ,1 PRINT NAME: L a r A. _ 1A /A Bulletin#100—January I, 1 1 I Page 1 of 3 k:'�Handouts\Permit Application 4 f Cu 6L JX c RES VALUE OF MECHANICAL WORK $ (a copy of bid or estimate be provided) Indicate how many of each type of fixture to be installed or relocated as part of this . . ect. Do not include existing fixtures to remain. AIR HANDLING UNITS FANS • PIPE OUTLETS OTHER(Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS(Commercial) BOILERS FURNACES HOT WATER TANKS)ca.) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES Indicate how many of each type of fixture to - installed or relocated as part of this project. Do not include existing fixtures to remain. BATHTUBS)or Tub/Shower Combo) 'VS)Hand Sink.) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS ocitrhen/utility) WATER HEATERS(Electric) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GEN-ERAI,INFOR1 ATIOi4 � ,..,, ,... , CRITICAL AREAS ON PROPERTY? WATER PUit//�/TF$YOR, SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS EXING/PREVIOUS S LOT SIZE)In Square Feet) EXISTING SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? �I�w �/ s ❑ No ❑Yes �(�Vo 4A" a �� r , - ..... y\•e 4 � ENTIAL' x � x '� c ', a 4 q ,rat"'" ',i.. -+t 5' „?Y r.�. AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE Bla 1 Via... FIRST FLOOR(or Mobile Home) 7',-,SECOND LOOR COVERED ENTRY GARAGE ❑ CARPORT [1 /` .. 1 R Ides s- Jv. EXISTING PROPOSED TOTAL Area Totals ESTIMATED SELLING PRICE$ J # OF BEDROOMS _ IVIN*RCIr.,= FIN/: DllIT Q i me, � .a. ��.. . , ,.�.. .«.�.. AREA DESCRIPTION Area Occupancy Group(s) Construction # of Additional Information in Square Feet Type Stories ADDITION C1O�k4 I1IEI I'Ir REAIODFI../T-F'ti__.A\1' I111)1 0VE i,FFJ ;T,Area AREA DESCRIPTION in Square Feet Occupancy Groups) Construction I TypeSt ries# of Additional Information TOTAL BUILDING,-, � TENANT AREA ONLY PItC1JELL Bulletin#100-January 1,2011 Page 2 of 3 k:AHandouts\Permit Application