Loading...
12-104375City of Federal Way Community & Econ. Dev. Services 33325 8th Ave S - Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: NORTHLAKE RIM LOT 4 Project Address: 4419 S 330TH PL Building -,Single Family Permit #: 12 -104375 -00 -SF Inspection Request Line: (253) 835-3050 Parcel Number: 618150 0040 Project Description: NEW - Construction of a 1,706 square foot, I -story single family residence with a 40 square foot covered entry, an 80 square foot covered covered patio & a 396 square foot garage. Includes plumbing & mechanical. ***Estimated selling price $287,886; 4 bedrooms*** Owner niicant Contracto Lender RICHMOND AMERICAN HOMES RICHMOND AMERICAN HOMES RICHMOND AMERICAN HOMES OWNER IS LENDER OF WA INC OF WA INC OF WA INC Type V - B 310 29TH ST NE SUITE 200 310 29TH ST NE SUITE 200 RICHMAH894JQ (4/18/13) New / Additional Sq. Feet - Garage ....................... 396 PUYALLUP WA 98372 PUYALLUP WA 98372 310 29TH ST NE SUITE 200 Occupancy #2 - Class ............................................. U New / Additional Sq. Feet - Other ..........................0 Plumbing to be Included?...................................... PUYALLUP WA 98372 New / Additional Sq. Feet - Total .......................... 2142 Census Category: 101- New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 U Construction Type: Type V- B Type V- B Occupancy Load- oadFloor Occupancy # I -Construction Type ....................... Type V - B FloorAreas . ft. 1,826 396 0 0 Additional Permit Information New / Additional Sq. Feet - 1 st Floor....................1746 New / Additional Sq. Feet - 2nd Floor ................... 0 New / Additional Sq. Feet - 3rd Floor....................0 Occupancy # I - Area (Sq. Feet) ............................. 1826 Occupancy #2 - Area (Sq. Feet).............................396 New / Additional Sq. Feet - Basement ................... 0 Basic Plan?........................................................... No Occupancy # I -Construction Type ....................... Type V - B Occupancy #2 - Construction Type ........................Type V - B New / Additional Sq. Feet - Deck .......................... 0 New / Additional Sq. Feet - Garage ....................... 396 Mechanical to be Included?................................... Yes Occupancy # 1 - Class.............................................R-3 Occupancy #2 - Class ............................................. U New / Additional Sq. Feet - Other ..........................0 Plumbing to be Included?...................................... Yes New / Additional Sq. Feet - Total .......................... 2142 Occupancy # I - Use ............................................... Residence (1 or 2 family) Occupancy #2 - Use ............................................... Private Garage Zoning Designation. ............................................... RS 9.6 Mechanical Fixtures; Ducting ........................................... 1 Fans................................................ 4 Fireplace Inserts............................. 1 Gas Piping ...................................... 1 Gas Pipe Outlets............................. 3 Plumbing fixtures Bathtubs ......................................... 2 Dishwashers................................... 1 Laundry Washer Outlets................ 1 Lavatories ....................................... 3 Sinks............................................... 3 Water Closets................................. 2 Water Heaters ................................. 1 Hose Bibbs..................................... 2 CONDITIONS: Development Conditions per KC 21A.12.030 in effect at final plat approval shall be the development standard for (5) years following final plat approval. Prior to Final Permit sign -off (and/or C of O),1 street tree shall be planted as shown on the approved street tree planting plan (Sheet ST -01- page 24 of 26 of the approved engineering plans). S d --f ,Prior to.Fipal Ijuilding or C. of O., a stormwater Declaration of Covenant shall be regorded on the property. Recording fee's to be paid by the applicant. s ` Footing drains to be connected to storm drain stub -out. Roof downspouts to be directed to on-site infiltration trenches. PERMIT EXPIRES Wednesday, April 3, 2013 Permit Issued on Friday, October 5, 2012 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and khe City of Federal Way. Owner or agent: te: l� J 2_ City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed byChi' y staff. Tenant Name: NORTHLAKE RIM LOT 4 Address: 4419 S 330TH PL Permit #: 12 -104375 -00 -SF Includes: #1 #2 #3 #4 Occupancy Class: R-3 U Construction Type: Type V- B Type V- B Occupancy Load Floor Area (sq. ft.) 1,826 396 0 0 Owner Name: RICHMOND AMERICAN HOMES OF Owner Address: 310 29TH ST NE SUITE 200 PUYALLUP WA 98372 4.,8.6. Building 3 -!s =/3 Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most seventy affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner / occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which itis situated. Such compliance is the responsibility of the owner and / or occupant of the premises. THIS CARD IS TO REMAIN nN-SITE r "TM OF Construction Inspection kecord Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 12 -104375 -00 -SF Address: 4419 S 330TH PL Project: RICHMOND AMERICAN HOMES OI FEDERAL WAY, WA 98001 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 SWM Precon Site Mtg (4400) Approved E] Initial Erosion Control (4365) To be done prior to breaking ground 0 Footings/Setback (4110) Approved to place concrete By Date By Date By Date Foundation Wall (4115) E] Drainage/Downspout (4040) Electrical Approved Plumbing Groundwork (4190) 1:1Approved Approved to place concrete By Approved to backfill Approved to cover By Date ` _ a $ 1 L By Date ` By Date Slab/Concrete Floor (4255) Underfloor Framing (4285) Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By C Date ` By V Date 13 Shear Walls (4245) Roof Sheathing (4220) Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved By Date 1-7 /3 ByG4� Date -7 r/? By Date _ Mechanical Rough -in (4165)Gas Piping (4125) Fire/Draft Stops (4095) Approved Approved to release test Approved By —A-7 < Date I _ -- ` By;J-1- `7 Date By Date ❑ Interim Erosion Control (4370) eduling a Framing inspection; Prior to:approved. Framing (4120) Approved Electrical, bing &Mechanical Rough -in and Approved to insulate By J2 Date �� "Y ll Fire/Draft Sinspections must be signed -off and IBC By _ Date 109.3.4 Gypsum Wallboard Nailing (4130) Insulation (4150) Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By 7 Date ' By I� Date 2 - 43 By Date Final - Mechanical (4065) Final - Plumbing (4075) Final - Building (4050) Approved Approved Approved By J Date3 - / f' .�3 By 0 -CV Date 3 ' 4S - /3 By Date 3 /S' 13 Rough ElectricalFinal Approved Electrical Approved 1:1Approved Right of Way By Date By Date By Date DATE, ITNSkCTOR AREA ANDTYPE OF INSPECTION G0 /I.�G�iD s✓ 71J S12 —Oe- Lv�iL P� • RECEIVED Federal V fW 2 5 2012 PERMIT `v l COAn1UN ELOPMfiN1'SERVICES APPLICATION ur.N(y w 259.495•.-2W7,FEDERAL WAY � CDS 3;2J _ t 0 q 7 SF MF CO ME PL DE EN FP I C/) q /12 - a0 arse ADDRESS 4419 South 330Th Place, Federal Way sOTtE/U1t1T ,r PROJECT VALUATION ZONM ASSMOA's TAX/PARCM 0 6181500040 _ TYPE OF PERBUT © BUILDING 0 PLUMBING O MECHANICAL O DEMOLITION D ENGINEEStING 0 FIRE PREVENTION NAME OF PROJECT (Tenant Narne/HomeounerLast Name) Northlake Rim 4 Construct single family residence PROJECT DESCRIPTION Detaited description of uork to be tnctuded on this permit only PROPERTY OWNER NAME Richmond American Homes of Washington rwMANTmo=253-446-7277 MAnkIGADORLSS 310 29th St NE Suite 200 WMAIL permitting@mdch.com crri Puyallup I "AW s>r 98372 NAM Richmond American Homes of Washington FROM 253-446-7277 CONTRACTOR MAKING ADDRESS 310 29th St NE Suite 200 �er itting@mdch.com clTr Puyallup WA Ts 98372 r AX SIA STATE CONTRACTOR'S LICENSE I EXPIRATION DATE F77AL WAT sU ea Limes e. RICHMAH894JQ 4 18 / 2014 20 -11 -103395 -00 -BL NAME Richmond American Homes of Washington ihlGNs 253-446-7277 APPLICANT MAILING ADDRESS 310 29th St NE Suite 200 s MAn permitting@mdch.com cm Puyallup WA 1 '98372 PAx PROJECT CONTACT NAME MORE 253-446-7277 Me indtutdual to receive and MAtWQADDRESS 310 29th St NE Suite 200 s•MA u. permitting@mdch.com respond to all correspondence concerning this application) CM Puyallup ZIP 98372 FAR ALTERNATE CONTACT NAME: MORS Z.KAM PROJECT FINANCING NAME � 0WMCR-FV(J4XCZD Required value of $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CrrY.. STATE. ZAP Mons I certVy ander penalty of perjury that I am the property owner or authorised argent of the property owner. I cart(ly that to the best of my knowledge, the igfarmation submitted in support gf this permit application is true and correct. I esrtyly that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance qr a permit. I understand that the issuance of this permit does not mnoee the owner's responsibility ,Jbr compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to held harmless the City gf Flederal Way as to any claim ancluding costs, expenses, and attorneys', fees incurred in the investigation and defense of such claim), which may be rade by any person, including the undersigned. andfiled against the city. but only when such claim arises out qr the reliance of the city. including its goksrs and employees, upon the accuracy of the Inrormatton supplied to the city as a this kation. SIGNATURE: DATE • PRINT NAME: Susan Olson Bulletin #100 —January 1, 2011 Page I of 3 k:Wandouts\Perrnit Application ` • 0 PLUMBING: FIXTURES Indicate how many of each type of fixture to be installed or relocated as part of this pro'ecL Do not triclude existing fixtures to remain. 2 BATHTUBS Im'Nh/sho«rrCombn) 3 IAVS (iandsink.) 2 TOILETS WATER PIPING 1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS 3 SINKS IHHc),en/u,ddri WATER tLEArERS (eiearic) Z HOSE BIB13S SUMPS t WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION MECHANICAL:: FIXTURES ::; ; VALUE OF MECHAMCAL WORK (a copy of bid or estimate must be provided) Indicate how many of each type offlxture to be installed or relocated as part oj this project. Do not include existingfixtures to remain. AER RANDLING UNITS 4 FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER t FIREPLACE INSERTS HOODS(com—w) BOILERS 1 FURNACES 1 HOT WATER TANKS Ica:) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING 1 GAS PIPING WOODSTOVES PLUMBING: FIXTURES Indicate how many of each type of fixture to be installed or relocated as part of this pro'ecL Do not triclude existing fixtures to remain. 2 BATHTUBS Im'Nh/sho«rrCombn) 3 IAVS (iandsink.) 2 TOILETS WATER PIPING 1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS 3 SINKS IHHc),en/u,ddri WATER tLEArERS (eiearic) Z HOSE BIB13S SUMPS t WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS # of Stories Additional Information NEW BUILDING EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? ADDITION Ye-�—ko D Yes E] No RESIDENTIAL. NEW OR ADDITY©N AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL. FOR OFFICE USE BASEMENT .................................. . FIRST FLOOR (or Mobile Horne) 1706 1706 SECOND FLOOR ..................... . COVERED ENTRY 40 40 DECK GARAGE O CARPORT 0 OTHER (describe) COV'd patio 80 80 ......--........... -- ----.._.. ........... ............ ........................ Area Totals e"wrlN" 187frD 18N **NEW HOMES ONLY— ESTIMATED SELLING PRICE $ 287886.00 # OF BEDROOMS 4 COMibIERCIAL .W"DDITIQN . AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction a # of Stories Additional Information NEW BUILDING ADDITION COMMERCIAL--:.REMODEUTENANT IMPROVEMENTS AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction a # of Stories Additional Information TOTAL BUILDING TENANT AREA ONLY PROJECTAREA ONLY Bulletin #100 — January 1, 2011 Page 2 of 3 01fandoutAPermit Application CIS NORTHLAKF PARCEL # ADDRESS: 4419 RICHMOND AMERI (253) 446-7277 PLAN #WE02-C LOT AREA: 5,714 SQ. FT. PROP. FOOTPRINT: SQ. FT. LOT COVERAGE: 34% DRIVEWAY CONC.: 409 SQ. FT COV'D PORCHES/LANDINGS: 1 TOTAL IMPERVIOUS AREA: 2,8 CONTRACTOR FOUNDATION DIMENSION: R.R. = 23' 5-1/2" R.L. = 52' 5-1/4" EX. 125" PRESSURE LIN EX. VALVE 80} NOTE: 5UILDING IS OFFSE' 5.00' NORTHEAST AND ALIGNED PARALLEL WITH TH SOUTHWEST PROPERTY LINE. RINA I nT 4' TO 6" QUARRY SPALLS FOR RESIDENTIAL SINGLE FAMILY LOTS (2" TO 6" QUARRY 6PALLS MAY BE ACCEPTED AT INSPECTOR'S DISCRETION) PROVIDE FULL WIDTH OF INGRESS/EGRE55 AREA 11 RESIDENTIAL CONSTRUCTION ENTRANCE ROCK PAD 11 !/MAN INFILTRATION NOTES: THE TOP OF INFTILTRA11ON FRENCH SHALL BE LOWER THAN THE ELEVATION OF THE PROPOSED STRUCTURE FOOTINGS. MINIMUM ROOF -DRAIN INFILTRATION TRENCH LENGTH = 70 L.F. MINIMUM ROOF -DRAIN INFILTRATION TRENCH DIMENSIONS ARE 2.0' WIDE AND 2.0' DEEP WITH A MINIMUM OF 6" COMPACTED BACKFILL ABOVE THE TRENCH. INFILTRATION TRENCH PER DETAILS ON SHEETS SD-02 AND DT-04 OF APPROVED CIVIL PLANS, APPROVED STORM REPORT PG. 28, A.E.S. INFILTRATION RECOMMENDATIONS REPORT DATED 3-14-2007, AND A.E.S. INFILTRATION LETTER DATED 6-1-2007 LEGEND X SILT FENCE CONSTRUCTION ENTRANCE TOPSOIL - S �WER I _ � WATER P 0 __u 7) rn 0 m' n i CITY OF FEDE CD5