18-102045City of Federal Way
Commwiity Development Dept.
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Project Name: AKINLOSOTU
Project Address: 33532 18TH AVE S
Project Description: Demolition of detached garage.
M1
Demolition
Permit #:18 -102045 -00 -DE
Inspection Request Line: (253) 835-3050
Parcel Number: 412940 0050
Owner
Applicant
Contractor
KENNEDY AKINLOSOTU
KENNEDY AKINLOSOTU
OWNER IS CONTRACTOR
19415 INTERNATIONAL BLVD SUITE 304
19415 INTERNATIONAL BLVD SUITE 304
SEATAC WA 98188
SEATAC WA 98188
Additional Permit Information
PERMIT EXPIRES Wednesday, 7 November, 2018
Permit Issued on Friday, May 11, 2018
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
ashi ton and the City of Federal Way. Q'
Owner or agent: Date: J U
` THIS CARD IS TO REMAIN ON-SITE
CITY OF Construction Inspection Record
Federal Way INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 18 102045 00 Address: 33532 18TH AVE S
Project: DORIS AKINLOSOTU FEDERAL WAY WA 98003-6822
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
® Final - Building (4050)
Approved
By ti , Date aS 4 — f Q.
❑
Rough Electrical
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
By
Date
By
Date
CITY OFVA�1& RECEIVED
PERMIT APPLICATION
Federal Way PERMIT CENTER + 33325 811,Avenue South + Federal Way, WA 98003-6325
MAY 11 20% 253-835-2607 + FAX 253-835-2609 + permitcente acityoffederalway.com
PERMIT NUMBER L E
TARGET DATE
SITE ADDRESSSUITE/UNIT #
�.3353] nn PNC
PROJECT VALUATION ZONING ASSESSOR'S TAX/PAD- --
$ID90_5®
TYPE OF PERMIT
BUILDING ❑ PLUMBING ❑ MECHANICAL ICJ llEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
— n
PROJECT DESCRIPTION
Detailed description of work to
be included on this permit only
N E ,j r
1 I ���
PRIMARY PHONE 2
-2✓'
PROPERTY OWNER
��k
MAILING ADDRESS_
E -MAI pp
CITY
STATE I
\ n
ZIP
Y
NAME
"LoPHONE
n o
MAILING ADDRESS , ^
V`
E-MAIL
CONTRACTOR
CITY
STATE
ZIP
FAX
WA STATE CONTRACTOR'S LICENSE #
EXPIRATION DATE
FEDERAL WAY BUSINESS LICENSE #
N
PRIMARY PHONE
23-
APPLICANT
MAILING ADDRESS`S
fo
E- L
C TY
STATE
"l
ZIPFAX
N ME
PRIMARY PHONE
PROJECT CONTACT�WmLsuiq
MAILING ADDRES
E-MAIL
(The individual to receive and
respond to all correspondence
CITY `} �`jvl C- STATE
ZIP ,
FAX
concerning this application)
PROJECT FINANCING
NAME
❑ OWNER -FINANCED
When value is $5,000 or more
(RCW 19.27.095)
MAILING ADDRESS, CITY, STATE, ZIP
PHONE
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city,
but only where such claim arises o t of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the ci of this application.
SIGNATU V' DATE
PRINT NAME: KowAhi
Bulletin #100 — January 29, 2016 Page 1 of 2 Ul-landoutsTermit Application
n
41k
CITY OFwrww�
Fedemoar l Way
COMMUNITY DEVELOPMENT DEPARTMENT
333258 1h Avenue South
Federal Way, WA 98003
253-835-2607; Fax 253-835-2609
www.cityoffederalway.com
DEMOLITION PERMIT REQUIREMENTS
A demolition permit is required to remove any structure on a subject property. Demolition of separate
structures may require separate permits.
Address of Demolition:
❑ Prior to submitting a demolition permit, the following items must be signed by the respective
agency or their approvals attached. Items not applicable to your project should be marked N/A.
❑ A completed Construction Permit Application form is also required.
1. ASBESTOS ABATEMENT
(Provide copy of Notice oflntentfrom Puget Sound Clean Air Agency
and cop Af inspection report by AHERA-certified inspector)
(City of Federal Wa Bilding Official)
2. FUEL STORAGE TANKS
❑ Under grade tank(s) is/are present
❑ Above grade tank(s) are present
❑ Tank(s) has been pumped or removed under South King Fire &
Rescue permit prior to any dismantling or excavation
S. ELECTRICITY
(Puget Sound Energy/Tacoma Power)
6. NATURAL GAS
I P,
(Puget Sound Energy)
N�yo�-
(South King Fire and Rescue) 7. WATER - Public Source
3. SEPTIC SYSTEM DECOMISSIONING
N►A-
(King Cou ty Environmental Services)
4. SANITARY SEWER
NIR-
(Lakehaven Utility District)
NJA
(Lakehaven Utility District)
8. WATER - Private Well
❑ Please Note: Erosion control measures must be in p
completion of the site clean-up.
N]i�
(King County E vironmental Services)
demolition and through
Bulletin # 122 — May 13, 2015 Page 1 of I k:\Handouts\Demolition Permit Requirements
5/10/2018 Approved Transaction
pscIeanair.org
Puget Sound Clean Air ,Agency
Single -Family Notification Case #: 201802086
This page must be printed. A printout of the notification, all amendments to the notification, and the asbestos survey shall be available
for inspection at all times at the asbestos project or demolition site (Reg III, 4.03(a)(6)).
Fee Amount Paid $65.00
Credit Card Transaction # AI0F797784E2
Transaction Date
05/10/18
Owner's Name
Kennedy Akinlosotu
Project Street Address 33534 18th Ave S
City
Federal Way
Contact Person
Kennedy E Akinlosotu
Mailing Address
23411 14th Ave. S
Des Moines, WA 98198
This project includes a demolition.
Demolition Start Date 05/10/18 Completion Date 05/12/18
Demolition will be completed by the home owner
Phone (206) 423-9999
Zip 98003
Phone (206) 423-9999
This is an emergency project. The emergency reason:
There was a sudden, unexpected event that resulted in a public health or safety hazard.
I certify that:
(1) This is a single-family residence project. The structure is used by one family who owns the property as their domicile.
(2) The information I have provided is to the best of my knowledge accurate and complete.
(3) I understand the fee for this Notification is nonrefundable.
Create Another Notification
If you have questions, contact us at asbestos@pscleanair.org or 206.689.4058.
https://secure.pscleanair.org/Asbestos/Approved.aspx 1/1
LIMITED ASBESTOS SURVEY
33534 18" Ave S.
Federal Way, WA 98003
Prepared for:
Kennedy Akinlosotu
2228 S. 312t" St.
Federal Way, WA 98003
Cole & Associates Training and Consulting, Inc.
8657 South 190t" St.
Kent, WA 98031
Phone: (425) 793-5505
Project #2018-05013
May 11, 2018
33534 18" Ave S.
Federal Way, WA 98003
TABLE OF CONTENTS
Limited Asbestos Survey
05.08.2018
EXECUTIVE SUMMARY.................................................................................................1
SCOPEOF SERVICES...................................................................................................1
WARRANTY....................................................................................................................2
ASBESTOSSURVEY.....................................................................................................3
Methodology........................................................................................................3
General References..................................................................................3
VisualInspection.................................................................................................3
Homogeneous Material Classifications..................................................3
Sampling Procedures.........................................................................................3
Laboratory Procedures.......................................................................................4
Methodof Analysis..................................................................................4
Laboratory Quality Control Program......................................................4
Findings and Observations................................................................................5
SurveyFindings.......................................................................................5
REPORTSUMMARY......................................................................................................6
APPENDICES...............................................................................................................10
Appendix A — LABORATORY BULK SAMPLE ANALYSIS REPORT
Appendix B — INSPECTOR & LABORATORY CERTIFICATIONS
33534 18" Ave S.
Federal Way, WA 98003
EXECUTIVE SUMMARY
Limited Asbestos Survey
05.08.2018
Cole & Associates Training and Consulting, Inc. (hereafter "Cole & Associates") was
retained by Kennedy Akinlosotu to conduct an Asbestos Spot Sampling Survey to
determine the presence of Asbestos -Containing Building Materials (ACBM) at 33534
18th Ave S., Federal Way, WA 98003. The garage is partially collapsed and targeted
spot sampling was conducted in the areas that inspector had safe access to; it is
believed the garage will be demolished.
The survey was conducted on Wednesday, May 8, 2018, beginning at 12:00 pm by
AHERA-Certified Building Inspector David Thulin, and included the testing of each
material as specified by the client. At the request of the client, a visual inspection was
conducted and samples were collected and tested.
Samples were transported to and analyzed by the EMSL Analytical Inc. a certified
laboratory in Seattle, WA.
One or more Homogenous Groups tested
CSV&jjjjNWuiJ&g M ", (AC
(See "photos" Section and Appendix A for specific details)
SCOPE OF SERVICES
This survey is limited to the testing and approximate quantification of materials
requested by the client.
A visual inspection was conducted in accordance with general Environmental Protection
Agency & Asbestos Hazard Emergency Response Act (EPA/AHERA) sampling
guidelines to determine the presence of exposed or accessible suspect ACM (Asbestos
Containing Material) and/or ACBM. A physical hand pressure test was conducted to
determine the friability of selected suspect materials.
Bulk samples were obtained from the suspect materials. Bulk samples were analyzed
by EMSL Analytical Inc. by Polarized Light Microscopy (PLM). The analytical results are
presented in Appendix A.
Page 1
33534 18" Ave S.
Federal Way, WA 98003
WARRANTY
Limited Asbestos Survey
05.08.2018
Cole & Associates Training and Consulting, Inc. warrants that the findings contained
herein have been assessed and reported in general accordance with accepted
professional practices as applied by similar professionals in the community at the time
of this report preparation. Changes in state of the art or in applicable regulations cannot
be anticipated and have not been addressed in this report. The field and laboratory
results reported herein are considered sufficient in detail and scope to determine the
presence, condition and hazard potential of the suspect ACBM at the time of this
survey. Test results are valid only for the materials tested.
This report is prepared for the express use and benefit of Isaac Marat. The information
in this report or portions thereof may be required to be included in notifications to
employees, contractors or other visitors to the building(s). This report is not intended to
be used by the owner or its agents as a specification contract document or work plan for
any work suggested or recommended in the report.
This report is based upon conditions observed at the property and information made
available to the inspector. This report does not intend to identify all environmental
hazards, nor is it intended to indicate that other hazards do not exist at the premises.
There is a distinct possibility that conditions may exist that could not be identified within
the scope of the survey or that were not apparent during the site visit. Conclusions
cannot be drawn regarding the presence or absence of other ACBM on the subject
structure due to the fact that this survey covered only those areas that were exposed,
visible or physically and/or readily accessible to the inspector and as specified in the
scope of services. All areas as specified in the scope of services were inspected and
sampled to the extent practical. Quantities of materials observed are estimates only and
should be verified prior to any abatement work.
Sampling of most materials was accomplished using a bulk sampling method. During
renovations, abatement or demolition, if additional suspect material is discovered it
should be assumed to be ACBM until sampled, analyzed and determined to be non -
asbestos containing material.
The survey was limited to the information available from the client at the time the survey
was conducted.
No other warranties are implied or expressed.
Page 2
33534 18" Ave S.
Federal Way, WA 98003
ASBESTOS SURVEY
Methodology
General References
Limited Asbestos Survey
05.08.2018
Inspection, sampling, and assessment procedures were performed in
general accordance with the guidelines published by the EPA in 40 CFR
Part 763 Subpart E, October 30, 1987.
The inspection consisted of the following major activities: visual inspection
and bulk sampling of suspect materials.
Visual Inspection
The visual inspection was performed by David Thulin, an AHERA-Certified
Asbestos Building Inspector. A preliminary walk-through was conducted to
determine homogeneous areas and the presence of suspect materials that were
accessible or exposed and included in the scope of work. Materials that were
similar in general appearance were grouped into homogeneous sampling areas.
Homogeneous Material Classifications
The walk-through of the structure was also conducted to determine areas
of materials that were visually similar in color, texture, and general
appearance and that appeared to have been installed at the same time.
These are termed "homogeneous materials" by the EPA. During this walk-
through, the approximate quantities and locations of these homogeneous
materials were noted. Only materials that were accessible or exposed,
included in the scope of work and suspected to contain asbestos were
identified.
Sampling Procedures
Following the walk-through, the inspectors collected selected samples of
exposed or accessible materials identified as suspect ACBM. Destructive
sampling was limited to accessible materials. No samples were taken that would
cause damage to the structural integrity of the item being tested.
EPA guidelines were used to determine the sampling protocol. Sampling_
locations were chosen to be representative of the homogeneous materials.
Samples of surfacing material were collected in general accordance with the EPA
random sampling protocol outlined in the EPA publication, "Asbestos in
Buildings: Simplified Sampling Scheme for Friable Surfacing Materials"
(EPA560/5-85-030a, October, 1985). Samples of miscellaneous materials were
taken as randomly as possible, while attempting to sample already damaged
areas so as to minimize disturbance of the material.
Page 3
33534 18" Ave S.
Federal Way, WA 98003
Laboratory Procedures
Method of Analysis
Limited Asbestos Survey
05.08.2018
Analysis was performed by visually observing the bulk sample and
preparing slides for microscopic examination and identification. The
samples were mounted on slides and then analyzed for asbestos
(chrysotile, amosite, crocidolite, anthophyllite, actinolite, and tremolite),
fibrous non -asbestos constituents (mineral wool, paper, etc.) and non-
fibrous constituents. Asbestos was identified by refractive indices,
morphology, color, pleochroism, birefringence, extinction characteristics,
and signs of elongation. The same characteristics were used to identify
the non -asbestos constituents.
The microscopist used a stereoscope to visually estimate relative amounts
of each constituent using a stereoscope to determine the volume of each
constituent in proportion to the total volume of the sample.
All bulk samples were analyzed by Polarized Light Microscopy (PLM) as
described by the "Interim Method of Determination of Asbestos in Bulk
Samples, EPA 600/R-93/116 Method." This is a standard method of
analysis in optical mineralogy and the current accepted method for the
determination of asbestos in bulk samples.
A suspect material is immersed in a solution of known refractive index and
subjected to illumination by polarized light. The characteristic color
displays that result enable mineral identification. It should be noted that
some ACBM may not be accurately identified or quantified by PLM if the
building material involved milling of asbestos fibers to extremely small
fibers. As a result, these fibers may go undetected under the standard
polarized light microscopy method. Transmission Electron Microscopy
(TEM) analysis is available for a more definitive analysis of these very
small sized asbestos fibers in those types of building materials.
Laboratory Quality Control Program
EMSL is certified by NVLAP and maintains an in-house quality control
program. This program involves blind reanalysis of ten percent of all
samples, precision and accuracy controls, and use of standard bulk
reference materials.
Page 4
33534 18" Ave S. Limited Asbestos Survey
Federal Way, WA 98003 05.08.2018
Findings and Observations
A material is considered by the EPA to be asbestos containing if at least one
sample collected from the area shows asbestos present in an amount greater
than one percent (>1 %). Please refer to the sample analysis sheets for a more
detailed description of the microscopic analysis of these samples.
The EPA National Emission Standards for Hazardous Air Pollutants (NESHAP)
requires an inspection for asbestos be done on facilities that are to undergo
demolition or renovation work. Materials found to contain asbestos may need to
be removed prior to the start of such demolition or renovation work.
NESHAP defines Category 1, 2, 3, and 4 non -friable asbestos -containing
materials such as gaskets, resilient floor covering, and asphalt roofing products
that contain more than one percent asbestos, and Category II non -friable as any
materials, except for Category I non -friable, that contain more than one percent
asbestos and cannot be reduced to a powder by hand pressure when dry.
NESHAP defines a Regulated Asbestos Containing Material (RACM) as: (a)
friable ACM, (b) Category I non -friable that has become friable, (c) Category
non -friable that has or may be subject to sanding, grinding, cutting, or abrading,
and (d) Category II non -friable that may or has become friable during demolition
or renovation.
Survey Findings
Samples were collected on May 8, 2018 and grouped together by
homogenous materials found in the table below. Laboratory analysis data
sheets can be found in Appendix A.
Page 5
33534 18" Ave S.
Federal Way, WA 98003
Limited Asbestos Survey
05.08.2018
Sample No. 1
Photo(s)
Result(s):
='
-
Description: Grey Roofing Tri -tab
Location(s): Exterior Roof
Comments:"~
i
Rim � 1Fr P
y
�
•b�
6,
i µrt
Sample No. 2
Photo(s)
Result(s):
Description: Black Roofing Paper
Location(s): Exterior Roof
7
Comments:
li
S
Sample No. 3
Photo(s)
Result(s):
Description: Wood W/ Black Tar
Location(s): Exterior Roof
Comments:
3.
Page 6
33534 18" Ave S.
Federal Way, WA 98003
Limited Asbestos Survey
05.08.2018
Sample No. 4
Photo(s)
Result(s):
Description: White Gypsum Board$
Location(s): Interior Garage
Comments:
Sample No. 5
Photo(s)
Result(s):
Photo Not Legible
Description: Brown Wood Material
Location(s): Exterior
Comments:
Sample No. 6
Photo(s)
Result(s):
Description: Brown Wall Paper
Location(s): Interior Garage
'E
Comments:
J
Page 7
33534 18" Ave S.
Federal Way, WA 98003
Limited Asbestos Survey
05.08.2018
Sample No. 7
Photo(s)
Result(s):
' µ
Description: White Window Putty
Location(s): Exterior Garage
Comments:
r.
'
Sample No. 8
Photo(s)
Result(s):
.,
k C
F
Description: White Ceiling Texture
r4 n
Location(s): Interior
Comments:
Page 8
3353418 th Ave S.
Federal Way, WA 98003
REPORT SUMMARY
Project Number
Inspector:
Survey Date:
Location:
2018-0513
David Thulin
May 8, 2018
3353418 1h Ave S.
Federal Way, WA 98003
Limited Asbestos Survey
05.08.2018
This survey is limited to the testing & approximate quantification of the areas specified
by the client.
One or more Homogenous Groups testea
Containing Building Material (ACBM).
/f9 "f /' x�L .
David Thuliln
AHERA Certified Building Inspector (CERTIFICATE #18 -BI -2355)
Cole & Associates Training and Consulting, Inc.
Page 9
33534 18" Ave S.
Federal Way, WA 98003
APPENDICES
Limited Asbestos Survey
05.08.2018
Appendix A — LABORATORY BULK SAMPLE ANALYSIS REPORT
Appendix B — INSPECTOR & LABORATORY CERTIFICATIONS
Page
10
APPENDIX A
LABORATORY BULK SAMPLE ANALYSIS REPORT
EMSL Analytical, Inc.
3317 3rd Ave S, Suite D 2nd floor Seattle, WA 98134
Tel/Fax: (206) 269-6310 / (206) 900-8789
http://www.emsl.com / seattlelab@emsl.com
Attention: Taunya Qualls
Cole & Associates Training & Consulting
8657 South 190th St
Kent, WA 98031
Project:
EMSL Order: 511801276
Customer ID: COLE21
Customer PO:
Project ID:
Phone:
(425) 793-5505
Fax:
(425) 793-5552
Received Date:
05/08/2018 2:00 PM
Analysis Date:
05/09/2018
Collected Date:
% Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-931116 Method using Polarized
Light Microscopy
Analyst(s)
Rudy Baum (8)
Lauren Kerber, Laboratory Manager
or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no
responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim
product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non -friable organically bound materials present a problem matrix and therefore EMSL
recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless
requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Seattle, WA NVLAP Lab Code 200613
Initial report from: 05/09/2018 13:21:40
ASS—PLM-0008-0001 - 1.78 Printed: 5/9/2018 10:21 AM Page 1 of 1
Non -Asbestos
Asbestos
Sample
Description
Appearance
% Fibrous
% Non -Fibrous
% Type
S-1
Gray tri -tab roofing
Black
15% Glass
10% Quartz
None Detected
Fibrous
75% Non-fibrous (Other)
511801276-0001
Homogeneous
S-2
Black roofing paper
Black
40% Cellulose
60% Non-fibrous (Other)
None Detected
Fibrous
511801276-0002
Homogeneous
S-3
Wood with black tar
Black
100% Non-fibrous (Other)
None Detected
Non -Fibrous
511801276-0003
Homogeneous
S-4
Gypsum, white
Brown/White
10% Cellulose
60% Gypsum
None Detected
Fibrous
30% Non-fibrous (Other)
511801276-0004
Homogeneous
S-5
Brown wool material
Brown
95% Glass
5% Non-fibrous (Other)
None Detected
Fibrous
511801276-0005
Homogeneous
S-6
Brown wall paper
Brown/Black
50% Cellulose
50% Non-fibrous (Other)
None Detected
Fibrous
511801276-0008
Homogeneous
S-7
White window putty
Gray
98% Non-fibrous (Other)
2% Chrysotile
Non -Fibrous
511801276-0007
Homogeneous
S-8
Ceiling texture, white
Beige
98% Non-fibrous (Other)
2% Chrysotile
Non -Fibrous
511801276-0008
Homogeneous
Analyst(s)
Rudy Baum (8)
Lauren Kerber, Laboratory Manager
or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no
responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim
product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non -friable organically bound materials present a problem matrix and therefore EMSL
recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless
requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Seattle, WA NVLAP Lab Code 200613
Initial report from: 05/09/2018 13:21:40
ASS—PLM-0008-0001 - 1.78 Printed: 5/9/2018 10:21 AM Page 1 of 1
APPENDIX B
INSPECTOR & LABORATORY CERTIFICATIONS
0
N
O _ _
a
y •
w a
m
C5 mm n
p- C7•
R1 ti
cy O E3 O O tD �&
cog
CD z
m O tQ N ' 0
C> m�Cl co
ca •�-�. a Q Obi
CD 0 rA
� � CD
ooj rA s -It � (1)o� o co t
r t-' ro, 0
CL
O cx Q 1��+ 1 o M� �
Cl)
CL O
=1m
o roCDC/ rnh
o_ m
C a G
CL
a Co
O C)
gvm0 CD
N
n14
CTI
a
C;
kyr( OF
® National Voluntary ate`
VLf. - - - I Laboratory Accreditation Program
oo
Sr#'
ArIS
SCOPE OF ACCREDITATION TO ISOIIEC 17025:2005
ENISL Analytical, Inc.
3317 3rd Avenue S, Suite D
Seattle, WA 98134
Ms. Lauren Kerber
Phone: 206-269-6310 Fax:206-900-8789
Email: lkerber@emsl.com
emsl.com
http://www.emsi.coin
ASBESTOS FIBER ANALYSIS
Bulk Asbestos Analysis
NVLAP LAB CODE 200613-0
Code Description
18/A01 EPA -- Appendix E to Subpart E of Part 763 -- Interim Method of the Determination of Asbestos in
Bulk Insulation Samples
18/A03 EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials
Airborne Asbestos Analysis
Code Description
18/A02 U.S. EPA's "Interim Transmission Electron Microscopy Analytical Methods -Mandatory and
Nonmandatory -and Mandatory Section to Determine Completion of Response Actions" as found in
40 CFR, Part 763, Subpart E, Appendix A.
Effective 2017-10-01 through 2018-09-30
For the National Volunta L borat ccreditation Program
Page I of I