13-103197 410 •Building - C.omercial City of Federal Way .�.( Community&Econ.Dev.Services Permit #: 13-103197-00-CO 33325 8th Ave S "" " _- Federal Way,WA 98003 F Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax (253)835-2609 ) p a ta»ti. _ Project Name: STARBUCKS Project Address: 2032 S 320TH ST Parcel Number: 092104 9296 Project Description: TI-Interior modifications including removal and relocation of steel columns,exterior rain screen/siding and site work, Includes plumbing&mechanical. Owner Applicant Contractor Lender STARBUCKS JODY FOX WILCOX CONSTRUCTION OWNER IS LENDER 2401 UTAH AVE S K D W SALAS O'BRIEN WILCOC*194Q0(12/10/13) SEATTLE WA 98134 10202 5TH AVE NE SUITE 102 234 5TH AVE S SEA!ILE WA 98125 EDMONDS WA 98020 Census Category: 437-Commercial alt/add/conversion Includes: #1 #2 #3 #4 Occupancy Class: B Construction Type: Type V-B Occupancy Load Floor Area(sq.ft.) 1,134 0 0 0 Additional Permit information Building Pre-con.Meeting Required? No Existing Sprinkler System in Building? No Mechanical to be Included? Yes Plumbing Work Valuation? 18000 Number of Stories. 1 Permit for Building Shell Only? No Plumbing to be Included? Yes Special Inspection(s)Required? Yes New/Additional Sq.Feet-Total 0 Occupancy#1-Use Restaurant Zoning Designation CC-C Mechanical Fixtures Air Handling Units. 2 Ducting 1 Fans 1 Refrigeration Systems. 3 Roof Top Units 1 Plumbing Fixtures Dishwashers. 1 Lavatories 3 Sinks 6 Vacuum Breakers. 1 Water Closets 1 Water Heaters 1 Hose Bibbs 7 CONDITIONS: Prior to any pavement removal/site work,install Catch Basin Sediment Protection(per details attached to plan set).Remove CB protection on after all site work is complete and fully stabilized for sediment transport. Site work depicted will be done under separate land use review.The work on this permit is for tenant improvements only. 4 *'IP '• A' P IT EXPIRES Saturday, April 12, 4 r ' rmit Issued on Monday, October 14, 20'T3 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use wil •- a «• •anc= ith the laws, rules and regulations of the State of Washington IPIPP 4 a •• •= City of Federal Way. Owner or agent: Date: 1Ø/4e`e 6. THIS CARD IS TO ON-SITE - , CITY OF • Construction In ection Record Federal Way INSPECTION REQUE TS: (253)835-3050 PERMIT#: 13-103197-00-CO Address: 2032 S 320TH ST Project: STARBUCKS FEDERAL WAY, WA 98003-5415 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. O SWM Precon Site Mtg(4400) -n Initial Erosion Control(4365) Footings/Setback(4110) Approved To be done prior to breaking ground Approved to place concrete By Date By Date By n. `,Na Date , ,r3 O Foundation Wall(4115) 0 Drainage/Downspout(4040) Re-steel(4215) Approved to place concrete Approved to backfill Approved to place concrete or grout By Date By Date By Date 0 Plumbing Groundwork(4190) Ei Slab/Concrete Floor(4255) ❑ Underfloor Framing(4285) Approved to cover Approved to place concrete Approved to sheath floor By Date By Date By Date Floor Sheathing(4105) 0 Shear Walls(4245) 0 Roof Sheathing(4220) Approved to install flooring Approved to install siding Approved to install roofing By Date By Date By Date 0 Rough Plumbing(4230) 0 Mechanical Rough-in(4165) 0 Gas Piping(4125) Approved Approved Approved to release test By Gam,, Date t�_. f l, 13 By. Date By Date O Fire/Draft Stops(4095) 0 Interim Erosion Control(4370) a Approved \\ Approved Prior to scheduling a Framing inspection, Electrical,Plumbing&Mechanical Rough-in and 1 Fire/Draft Stop inspections must be signed-off and By Date ByDate approved. IBC 109.3.4 • O Framing(4120) ' 0 Insulation(4150) 0 Gypsum Wallboard Nailing(4130) Approved to insulate Approved to install wallboard Approved to install mud&tape By Date 1-1- —r,h By{ Date Date C, g/t.� . O Suspended Ceiling Grid(4265) ❑ Final-Fire Department(4060) 0 Final-Planning Approved to drop tile Approved Approved By 0 -- Date Ai-) By Date By Date .i Final-Public Works(4080) r 0 Final Erosion Control(4375) Final-Mechanical(4065) Approved Approved Approved By Date By Date By \o, Date t ‘--1‹,,,t, Final-Plumbing(4075) 0 Final-Building(4050) Approved Approved ByIw►. . Date 1 1..•V�1 , By VY.�J Date 1\_ N,%^A 3 0 Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date DATE INSPECTOR AREA AND TYPE C NSPECTION CEIVED ATIN CITY Of A. ,l 1,7 2013 PERMI'�APPLIC O Federal Way - CITY OF FEDECDSRAL WAY PERMIT NUMBER / _ - 1 � �/ � � �� TARGET DATE 9/r /3 SITE ADDRESS Starbucks SUITE/UN # 2032 S 320th Street Federal Way,WA 98003 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ 310K c 092104-9296 _ TYPE OF PERMIT ® BUILDING XPLUMBING MECHANICAL ❑ DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT Starbucks 320th Street y�nn�'�` Remodel of existing Starbucks cafe space including mechanical, plumbing am:WI:lrieaf PROJECT DESCRIPTION Detailed description of work to changes, site work, and the relocation of two steel columns. be included on this permit only ... NAME PRIMARY PHONE PROPERTY OWNER Starbucks Coffee Company 206.318.1575 MAILING ADDRESS E-MAIL 2401 Utah Avenue South, MS Stop:S-SD10 lkirschm@starbucks.com CITY STATE ZIP Seattle WA 98134 NAME PHONE TBD ( (' r'71r MAILING DRESS "�" E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# NAME PRIMARY PHONE KDW Salas O'Brien-Jody Fox- Intern Architect 206.547.1940 APPLICANT MAILING ADDRESS E-MAIL 10202 5th Ave NE,Suite 300 CITY STATE ZIP FAX Seattle WA 98125 NAME PRIMARY PHONE PROJECT CONTACT Jody Fox- Intern Architect 206.547.1940 (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence 10202 5th Ave NE, Suite 300 concerning this application) CITY STATE ZIP FAX Seattle WA 98125 NAME PROJECT FINANCING ® OWNER-FINANCED Required value of$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs, expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE: DATE 07-16-2013 PRINT NAME: Jody Fox Bulletin#100—January 1,2013 Page 1 of 3 k:\Handouts\Permit Application • . VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ 20K Indicate hew many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. at.< 2 AIR 3ANDLIIUUNITS 1 FANS GAS PIPE OUTLETS OTHER(Describe) ' AITjQNDI . R FIREPLACE INSERTS HOODS(Commercial) BOI! RS - FURNACES HOT WATER TANKS(Gas) COMPRESSORS GAS LOG SETS 3 REFRIGERATION SYST 9 DUCTING GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT $ 18K Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. BATHTUBS(or Tub/Shower Combo) 3 LAVS(Hand Sinks) 1 TOILETS 4 WATER PIPING 1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) 5 DRAINS SHOWERS 1 VACUUM BREAKERS DRINKING FOUNTAINS 6 SINKS(kitchen/Utility) 1 WATER HEATERS(Electric) tft/7 HOSE BIBBS SUMPS WASHING MACHINES 29 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS N/A Lake Haven Utility District Lake Haven Utility District $ 67,300 EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Starbucks Cafe 16,624 sqft ❑ Yes X No ❑ Yes X No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE FIRST FLOOR(or Mobile Home) COVERED ENTRY GARAGE ❑ CARPORT ❑ EXISTING PROPOSED TOTAL Area Totals ESTIMATED SELLING PRICE$ #OF BEDROOMS COMMERCIAL—NEW/ADDITION AREA DESCRIPTION Occupancy Groups) Construction St roses Additional Information ADDITION COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION 11111FEN Occupancy Group(s) Wail #of Additional Information Stories TENANT AREA ONLY 1,134 sq ft B V-B 1 Bulletin#100-January 1,2013 Page 2 of 3 k:\Handouts\Permit Application