13-103197 410 •Building - C.omercial
City of Federal Way .�.(
Community&Econ.Dev.Services Permit #: 13-103197-00-CO
33325 8th Ave S "" " _-
Federal Way,WA 98003 F Inspection Request Line: (253)835-3050
Ph:(253)835-2607 Fax (253)835-2609 ) p a
ta»ti. _
Project Name: STARBUCKS
Project Address: 2032 S 320TH ST Parcel Number: 092104 9296
Project Description: TI-Interior modifications including removal and relocation of steel columns,exterior rain
screen/siding and site work, Includes plumbing&mechanical.
Owner Applicant Contractor Lender
STARBUCKS JODY FOX WILCOX CONSTRUCTION OWNER IS LENDER
2401 UTAH AVE S K D W SALAS O'BRIEN WILCOC*194Q0(12/10/13)
SEATTLE WA 98134 10202 5TH AVE NE SUITE 102 234 5TH AVE S
SEA!ILE WA 98125 EDMONDS WA 98020
Census Category: 437-Commercial alt/add/conversion
Includes: #1 #2 #3 #4
Occupancy Class: B
Construction Type: Type V-B
Occupancy Load
Floor Area(sq.ft.) 1,134 0 0 0
Additional Permit information
Building Pre-con.Meeting Required? No Existing Sprinkler System in Building? No
Mechanical to be Included? Yes Plumbing Work Valuation? 18000
Number of Stories. 1 Permit for Building Shell Only? No
Plumbing to be Included? Yes Special Inspection(s)Required? Yes
New/Additional Sq.Feet-Total 0 Occupancy#1-Use Restaurant
Zoning Designation CC-C
Mechanical Fixtures
Air Handling Units. 2 Ducting 1 Fans 1
Refrigeration Systems. 3 Roof Top Units 1
Plumbing Fixtures
Dishwashers. 1 Lavatories 3 Sinks 6
Vacuum Breakers. 1 Water Closets 1 Water Heaters 1
Hose Bibbs 7
CONDITIONS:
Prior to any pavement removal/site work,install Catch Basin Sediment Protection(per details attached to
plan set).Remove CB protection on after all site work is complete and fully stabilized for sediment transport.
Site work depicted will be done under separate land use review.The work on this permit is for tenant
improvements only.
4
*'IP '• A' P IT EXPIRES Saturday, April 12, 4 r '
rmit Issued on Monday, October 14, 20'T3
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use wil •- a «• •anc= ith the laws, rules and regulations of the State of Washington
IPIPP
4
a •• •= City of Federal Way.
Owner or agent: Date: 1Ø/4e`e 6.
THIS CARD IS TO ON-SITE - ,
CITY OF • Construction In ection Record
Federal Way INSPECTION REQUE TS: (253)835-3050
PERMIT#: 13-103197-00-CO Address: 2032 S 320TH ST
Project: STARBUCKS FEDERAL WAY, WA 98003-5415
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
O SWM Precon Site Mtg(4400) -n Initial Erosion Control(4365) Footings/Setback(4110)
Approved To be done prior to breaking ground Approved to place concrete
By Date By Date By n. `,Na Date , ,r3
O Foundation Wall(4115) 0 Drainage/Downspout(4040) Re-steel(4215)
Approved to place concrete Approved to backfill Approved to place concrete or grout
By Date By Date By Date
0 Plumbing Groundwork(4190) Ei Slab/Concrete Floor(4255) ❑ Underfloor Framing(4285)
Approved to cover Approved to place concrete Approved to sheath floor
By Date By Date By Date
Floor Sheathing(4105) 0 Shear Walls(4245) 0 Roof Sheathing(4220)
Approved to install flooring Approved to install siding Approved to install roofing
By Date By Date By Date
0 Rough Plumbing(4230) 0 Mechanical Rough-in(4165) 0 Gas Piping(4125)
Approved Approved Approved to release test
By Gam,, Date t�_. f l, 13 By. Date By Date
O Fire/Draft Stops(4095) 0 Interim Erosion Control(4370) a
Approved \\ Approved Prior to scheduling a Framing inspection,
Electrical,Plumbing&Mechanical Rough-in and
1 Fire/Draft Stop inspections must be signed-off and
By Date ByDate approved. IBC 109.3.4
•
O Framing(4120) ' 0 Insulation(4150) 0 Gypsum Wallboard Nailing(4130)
Approved to insulate Approved to install wallboard Approved to install mud&tape
By Date 1-1- —r,h By{ Date Date C, g/t.� .
O Suspended Ceiling Grid(4265) ❑ Final-Fire Department(4060) 0 Final-Planning
Approved to drop tile Approved Approved
By 0 -- Date
Ai-) By Date By Date
.i Final-Public Works(4080) r 0 Final Erosion Control(4375) Final-Mechanical(4065)
Approved Approved Approved
By Date By Date By \o, Date t ‘--1‹,,,t,
Final-Plumbing(4075) 0 Final-Building(4050)
Approved Approved
ByIw►. . Date 1 1..•V�1 , By VY.�J Date 1\_ N,%^A 3
0 Rough Electrical Final Electrical Right of Way
Approved Approved Approved
By Date By Date By Date
DATE INSPECTOR AREA AND TYPE C NSPECTION
CEIVED
ATIN
CITY Of A. ,l 1,7 2013 PERMI'�APPLIC O
Federal Way -
CITY OF FEDECDSRAL WAY
PERMIT NUMBER / _
- 1 � �/ � � �� TARGET DATE 9/r /3
SITE ADDRESS Starbucks SUITE/UN #
2032 S 320th Street
Federal Way,WA 98003
PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL#
$ 310K c 092104-9296 _
TYPE OF PERMIT ® BUILDING XPLUMBING MECHANICAL ❑ DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION
NAME OF PROJECT Starbucks 320th Street y�nn�'�`
Remodel of existing Starbucks cafe space including mechanical, plumbing am:WI:lrieaf
PROJECT DESCRIPTION
Detailed description of work to changes, site work, and the relocation of two steel columns.
be included on this permit only
... NAME PRIMARY PHONE
PROPERTY OWNER Starbucks Coffee Company 206.318.1575
MAILING ADDRESS E-MAIL
2401 Utah Avenue South, MS Stop:S-SD10 lkirschm@starbucks.com
CITY STATE ZIP
Seattle WA 98134
NAME PHONE
TBD ( (' r'71r
MAILING DRESS "�" E-MAIL
CONTRACTOR
CITY STATE ZIP FAX
WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE#
NAME PRIMARY PHONE
KDW Salas O'Brien-Jody Fox- Intern Architect 206.547.1940
APPLICANT MAILING ADDRESS E-MAIL
10202 5th Ave NE,Suite 300
CITY STATE ZIP FAX
Seattle WA 98125
NAME PRIMARY PHONE
PROJECT CONTACT Jody Fox- Intern Architect 206.547.1940
(The individual to receive and MAILING ADDRESS E-MAIL
respond to all correspondence 10202 5th Ave NE, Suite 300
concerning this application) CITY STATE ZIP FAX
Seattle WA 98125
NAME
PROJECT FINANCING ® OWNER-FINANCED
Required value of$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE
(RCW 19.27095)
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim(including costs, expenses,and attorneys'fees incurred in
the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as a part of this application.
SIGNATURE: DATE 07-16-2013
PRINT NAME: Jody Fox
Bulletin#100—January 1,2013 Page 1 of 3 k:\Handouts\Permit Application
• .
VALUE OF MECHANICAL WORK
MECHANICAL PERMIT $ 20K
Indicate hew many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain.
at.< 2 AIR 3ANDLIIUUNITS 1 FANS GAS PIPE OUTLETS OTHER(Describe)
' AITjQNDI . R FIREPLACE INSERTS HOODS(Commercial)
BOI! RS - FURNACES HOT WATER TANKS(Gas)
COMPRESSORS GAS LOG SETS 3 REFRIGERATION SYST
9 DUCTING GAS PIPING WOODSTOVES
VALUE OF PLUMBING WORK
PLUMBING PERMIT $ 18K
Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain.
BATHTUBS(or Tub/Shower Combo) 3 LAVS(Hand Sinks) 1 TOILETS 4 WATER PIPING
1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe)
5 DRAINS SHOWERS 1 VACUUM BREAKERS
DRINKING FOUNTAINS 6 SINKS(kitchen/Utility) 1 WATER HEATERS(Electric)
tft/7 HOSE BIBBS SUMPS WASHING MACHINES 29 TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS
N/A Lake Haven Utility District Lake Haven Utility District $ 67,300
EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM?
Starbucks Cafe 16,624 sqft ❑ Yes X No ❑ Yes X No
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
FIRST FLOOR(or Mobile Home)
COVERED ENTRY
GARAGE ❑ CARPORT ❑
EXISTING PROPOSED TOTAL
Area Totals
ESTIMATED SELLING PRICE$ #OF BEDROOMS
COMMERCIAL—NEW/ADDITION
AREA DESCRIPTION Occupancy Groups) Construction St roses Additional Information
ADDITION
COMMERCIAL—REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION 11111FEN Occupancy Group(s) Wail #of Additional Information
Stories
TENANT AREA ONLY 1,134 sq ft B V-B 1
Bulletin#100-January 1,2013 Page 2 of 3 k:\Handouts\Permit Application