Loading...
15-103500City of Federal Way Corrununity &Econ. Dev. Services FILE 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: ALPHA ADULT FAMILY HOME 3 Project Address: 2032 S 333RD ST - t wilding - Single Family Permit #: 15 -103500 -00 -SF Inspection Request Line:. (253) 835-3050 Parcel Number: 413150 0190 Project Description: ALT - Verification of Occupancy for Adult Family Home. ***No construction work allowed under this permit.*** Owner AR lin cant Contractor Lender FRANCISCA KARANJA FRANCISCA KARANJA Occupancy Load JOSEPH KARANJA ALPHA ADULT FAMILY HOME 3 ALPHA ADULT FAMILY HOME 3 2622 S 296TH PL 2622 S 296TH PL FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 Census Category: 999 - Unknown Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load Floor Areas . ft. 3,200 1 0 1 0 1 0 Additional Permit Information New / Additional Sq. Feet - 3rd Floor....................0 Occupancy # 1 - Area (Sq. Feet) ............................. 3200 New / Additional Sq. Feet - Basement...................0 Occupancy # 1 - Construction Type .......................Type V - B Mechanical to be Included?....................................No gddilecuipancy #1 - Class ............................................. R-3 Plumbing to be Included?.......................................No pancy # 1 - Use ............................................... Residence (Care/Assisted Living) No Fixt associated With This PermitIll PERMIT EXPIRES Wednesday, January 13, 2016 Permit Issued on Friday, July 17, 2015 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use ill e n accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: CITY OF VAII� Federal Way PERMIT #: Project: THIS CARD IS TOMAIN ON-SITE ,. Construction In ection Record INSPECTION REQU TS: (253) 835-3050 15 -103500 -00 -SF Address: 2032 S 333RD ST FRANCISCA KARANJA FEDERAL WAY, WA 98003-6829 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. Final - Building (4050) Approved By �* Date S t' I ( c— © Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date Adult Family Ho* (AFH) LOCAL BUILDING INSPEGON CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1. 2. 3. AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION WILL BE PROCESSED SECTION 1— PROPERTY INFORMATION PROPERLY OWNER NAME: 00 DAYTIME PHONE: �C� M c! cw W /"��4gm /7 AFH LICENSEE NAME (IF ot�r�rn): tJ DAYTIME PHONE: SECTION 3 — FLOOR PLAN On a separate sheet of paper (8 1/2x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms (bedrooms) indicating which bedroom is: A, B, C D, E and F. Label all components for exiting i.e., stairs, ramps, platforms, lifts and elevators. I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home at this location. I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any person, including the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application. 'I // rh NAME/TITLE: - r DATE: PROPERTY OWNER DAPPLICANT Q LICENSEE JUL 17 2015 Effective: 2013 July 01 CITY OF FEDERAL WAY Updated: 2013 June CDS I, NAME OF AFH: 7Y. �-9U 4E /7 F-�H .> -- -- - SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. PLEASE CHECK ALLAPPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN — USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A 8 CD E AND F AND CLASSIFICATION CODE S, NSl OR NS2. SECTION 5 - BUILDING INSPECTOR'S INSPECTION CHECKLIS I R325.3 Sleeping Room Classification: Each sleeping room in an Adult tamily Home shall be classinea as: Type S — where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. Type NS1— where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R325.9 is provided to evacuate residents to public area. T—e NS) — where 2 means of aoross at yard level !both have no stairs) or ramps constructed compliant wA<R325.9 are provided to evacuate residents to public area. SLEEPING ROOM A0 Type S Type NSi Type NS2 YES NO Closet door/s are readily openable from the inside YesSmoke alarm is installed in the bedroom W E3 Bedroom door opens easily and quickly from the outside when locked Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.1.1: at -grade escape windows - may have net clearance opening 5 SF Q Sleeping room window has a maximum sill height of 44" above floor, no steps under indow permitted 0 SLEEPING ROOM B TOType S jErType NSi 1 E3 Type NS2 YES NO Closet door/s are readily openable from the inside Yes No Smoke alarm is installed in the bedroom 13 Bedroom door opens easily and quickly from the outside when locked W 13 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.1.1: at -grade escape windows - may have net clearance opening 5 SF 13� 13 Sleeping room window has a maximum sill height of 44" above floor; no steps under indow permitted SLEEPING ROOM C 113Type S OType NSI I E3 Type NS2 YES NO oe Closet door/s are readily openable from the inside Yes No Smoke alarm is installed in the bedroom a' E3 Bedroom door opens easily and quickly from the outside when locked ff Q- Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.1.1: at -grade escape windows - may have net clearance opening 5 SF ®' 13 Sleeping room window has a maximum sill height of 44" above floor; no steps under ndow permitted M 13 SLEEPING ROOM D TOType S ype NSi I E3 Type NS2 YES NO Closet door/s are readily openable from the inside [ZYes 113No I Smoke alarm is installed in the bedroom Bedroom door opens easily and quickly from the outside when locked 0 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.1.1: at -grade escape windows - may have net clearance opening 5 SF Q Sleeping room window has a maximum sill height of 44" above floor; no steps under indow permitted E,] SLEEPING ROOM E le TaType S 10Type NSi I D Type NS2 YES NO Closet door/s are readily openable from the inside JOYes 113No Smoke alarm is installed in the bedroom 0' [j Bedroom door opens easily and quickly from the outside when locked CY 13 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.1.1: at -grade escape windows - may have net clearance opening 5 SF 13 Sleeping room window has a maximum sill height of 44" above floor; no steps under window permitted 13 SLEEPING ROOM F Type S E3 Type NSi E3 Type NS2 YES NO Closet door/s are readily openable from the inside 113yes 113No Smoke alarm is installed in the bedroom 13 Bedroom door opens easily and quickly from the outside when locked 13 0 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) EXCEPT per R310.1.1: at -grade escape windows - may have net clearance opening 5 SF 0 13 Sleeping room window has a maximum sill height of 44" above floor; no steps under window permitted Effective: 2013 July 01 Updated: 2013 June GENERAL YE NO Bathroom doors are easily and quickly openable from the outside when locked 13 0 Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. O 13 Smoke alarms are installed on all levels of the dwelling, in each resident sleeping room, outside each separate 13 13 sleeping area in the immediate vicinity of sleeping rooms (11314). D 13 Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all YES 0 parts of the dwelling upon activation of a single device. 13 13 Access road and water supply meet local fire jurisdictional requirements. 0 R325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand 0 13 and shall not require tight grasping, pinching or twisting of the wrist (lever -type). 13 Q Pocket doors shall have graspable hardware available when in the closed or open position. Cr 13 VWP kv�Vofto R311.8 Ramps YES NO 09 Inside Ramp i N/A 13 0 R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in AFH) O R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes directions. 13 13 R325.9.1 Handrails requirecVn both sides of ramp in accordance with R311.8.3.1- R311.8.3.3. D 13 Outside Ramp N/A YES NO R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in AFH) 13 13 R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes directions. R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1- R311.8.3.3. 0 13 Guards below are depicted vertically as an example only. All Ramps must have Guards 13 Q Guard 36" min Handrail both sides Less than 4" F 34" - 38" 3'x3'min —` landing —3 — - One unit vertical in twelve units horizontal minimum is an 8.3% slope all along surface of the ramp. 3'x3'min landing I � -- 3' —►� minimum R311.2 Means of Egress YES NO R311.2 Door must be side -hinged with min. width of 32 inches between face of door and stop. Height not less than 78 inches. R325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand J/ and shall not require tight grasping, pinching or twisting of the wrist (lever -type). O R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry to 0 without use of key, tool ors cial knowledge. Required exit door shall have no additional locking devices. 8311.7 Stairways I N/A EF I YES NO R311.7.4.1 Riser Height: Max riser height shall be 7 % inches (8 inches in structures built prior to July 1, 2004) R311.7.4.2 Tread Depth: Min. tread depth shall be in 10 inches (9 inches in structures built prior to July 1, 2004) Cl R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple 13 a risers. Handrails shall be installed in accordance with R311.7.7.1- R311.7.7.4 Effective: 2013 July 01 Updated: 2013 June R32.5.8 Grab Bars in Bathrooms I N/A N Grab bars shall be installed for all water closets (toile bathtubs d showers according to R325.8. Water Closets (toilet) shall have grab bars installed on both sides according to R325.8 — R325.8.3.2. Er A&Z Bathtubs shall have two vertical and three horizontal grab bars installed according to R325.8 — R325.8.2 & R325.8.4 — R325.8.4.2 Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R325.8 — R325.8.2 & 13 R325.8.5 — R325.8.5.2. Shower stalls must be minimum size of 30 inches deep by 48 inches long (11325.11) AG103 - AG105 Swimming Pool, Spa, Hot Tub YES NO AF105.2 Must be surrounded by a barrier that is 48 inches high, may have doors and or gates that must have audible alarms when 13 0 opened. AG105.5 EXCEPTIO . Pools, Spas or Hot Tubs wit safety cover which complies with ASTM F 1346 PASSED RECTIONS REQUIRED Q PERMITREQUIRED INSPECTOR'S NAME (PRINT) is l r5" INSPECTOR'S SIGNATURE DATE: (✓l'r+9 OF F"�if�i 'IA1. �AJ�' `�— �iI.TH i,�'1k'4i- Z� ' ��ib�' �s `%7 INSPECTOR'S OFFICE ADDRESS PHONE NUMBER: Application and inspection checklist developed by Washington Association of Building Officials (WABO), in cooperation with Department of Social and Health Services (DSHS) for use by both departments and licensors. 07/01/2013 Effective: 2013 July 01 Updated: 2013 June CITY OF A� Federal Way I (--' /,� —�, /-� m�o�nzrNnMoa�� \.�� | \_� ��� ^-� ( �{ � `�_���-� - TARGET DATE JUL 1jr2015 CM OF FEDERAL WAY CDS SITE ADDRESS SUITE/UNIT# PROJECT VALUATION ZONING ASSESSOR'S TAXIPARCEL # TYPE OF PERMIT 0 BUILDING El PLUM13ING 1:1 MECHANI CAL 0 DEMOLITION 0 ENGINEERING El FIRE PREVENTION NAME OF PROJECT 7 PROJECT DESCRIPTION Detailed description of work to 14;t *17 be included on this permit only NAME PRIMARY P PROPERTY OWNER Ce, - Ho"F MAILING ADDAESS E-MAIL CITY STATE ZIP V MAILINGADDRESS E-MAIL CONTRACTOR CITY STATE ZIP VAX WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # SAME PRIMARY PHONE APPLICANT &AILING ADDRESS E-MAIL STATE ZIP FAX PROJECT CONTACT NAME PRII PHONE (The individual to receive and MAILIAG ADDI&SS E-MAIL respond to all correspondence conceming Ods application) Cr STATE ZIP FAX PROJECT FINANCING NAME 60 71 %0, OWNER -FINANCED Required value of$5,000 or more MAILING ADDRESS, CITY, STSTE, ZIP I certify under penalty ofperjury that I am the property owner or authorized agent of the property owner. I cerqN that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a per,, it. I understand that the issuance Of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. Ifurther agree to hold harmless the City of Federal Way as to any claim (including costs� expenses, and attomeysfees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, andfiled against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: r%ATE PRINT NAIME: V BoUchu#l0O-January l 2013 Page lof9 k:\Handouts\Permit Application