16-101017City of Federal Way FILE Community Development Dept. Lender 33325 8th Ave S WHEELER RENOVATORS LLC Federal Way, WA 98003 OWNER IS LENDER Ph: (253) 835-2607 Fax: (253) 835-2609 PO BOX 587 Project Name: SORDAHL Project Address: 29203 13TH PL S Building - Single Family Permit #:16 -101017 -00 -SF Inspection Request Line: (253) 835-3050 Parcel Number: 720560 0100 Project Description: REP - Roof truss repair and drywall replacement at truss replacment due to tree damage" *REVISED 5/24/18 TO INCLUDE PLUMBING AND MECHANICAL*** Owner Applicant Contractor Lender JEFFREY A SORDAHL WHEELER RENOVATORS LLC C & S CONSTRUCTION OWNER IS LENDER 29203 13TH AVE S PO BOX 587 3256 S 360TH FEDERAL WAY WA 98003-3743 BLACK DIAMOND WA 98010 AUBURN WA 98001 Census Category: 434 - Residential alt/add - no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) Additional Permit Information New / Additional Sq. Feet - 3rd Floor ..................... 0 New / Additional Sq. Feet - Basement.................... 0 Occupancy #1 - Construction Type ......................... Type V - B Mechanical to be Included?..................................... Yes Is this an Online or O.T.C. application? .................. No Plumbing to be Included?........................................ Yes Occupancy #1 -Use ................................................ Residence (1 or 2 family) Fans 1 Bathtubs 1 CONDITIONS: ***TRUSS SPECIFICATIONS TO BE ON SITE AT THE TIME OF INSPECTION*** PERMIT EXPIRES Tuesday, 20 November, 2018 Permit Issued on Friday, February 26, 2016 I hereby certify that the above information is and the occupancy and the use MI be in Owner or agent: and that the construction on the above described property ince with the laws, rules and regulations of the State of he City of Federal Way. Date: l ` THIS CARD IS TO REMAIN ON-SITE CITY OF Construction Inspection Record Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 16 101017 00 Address: 29203 13TH PL S Project: JACQUELIN M SORDAHL FEDERAL WAY WA 98003-3743 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ® SWM Precon Site Mtg (4400) 2❑ Initial Erosion Control (4365) ® Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date By Date By Date ® Plumbing Groundwork (4190) ® Underfloor Framing (4285) ® Floor Sheathing (4105) Approved to cover Approved to sheath floor Approved to install flooring By Date By Date By Date ® Shear Walls (4245) ® Roof Sheathing (4220) ® Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved By Date By Date By Date E] Mechanical Rough -in (4165) El Gas Piping (4125) 92 Fire/Draft Stops (4095) Approved Approved to release test Approved By Date By Date By Date 13 Interim Erosion Control (4370) Prior to scheduling a Framing inspection;i4 Framing (4120) Electrical, Plumbing & Mechanical Rough -in Approved and Fire/Draft Stop inspections must be s gned- Approved to insulate By Date off and approved. IBC 109.3.4 By Date IT Insulation (4150) Gypsum Wallboard Nailing (4130) 97 Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By Date By Date By Date Es Final - Mechanical (4065) Final - Plumbing (4075) zo Final - Building (4050) Approved Approved�, Approved By (-J Date By f Date (c By Date �// ?l Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date TSE Engin e e ring Re: SJ604428 Weaver Renovators / Sordahl / ML FILE Tri-State Engineering, Inc. 12810 NE 178th Street Suite 218 Woodinville, WA 98072 425.481.6601 The truss drawing(s) referenced below have been prepared by Tri-State Engineering under my direct supervision based on the parameters provided by The Truss Company (Sumner). Pages or sheets covered by this seal: I11129042 thruI11129042 My license renewal date for the state of Washington is August 20, 2016. .4 L,. Pp Wnsh��c�C b a� 0� 19969 _ - — � V May 2,2016 Terry Powell The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1. RECEIVED MAY 2 4 2018 m1111(�t�tFf�bfi�, .iVt(!4X Job Truss Truss Type Qty Ply Weaver Renovators I Sordahl / ML r BOT CHORD 26-0-0 ' WEBS 8-11-0 111129042 SJ604428 Al FINK 7 t Installation guide. Plate Offsets (X Y)- [2:0-3-14.0-1-8].[6:0-3-14.0-1-81 (Ib/size) 2=1216/0-5-8 (min. 0-2-0),6=1216/0-51-8 (min. 0-2-0) Max Horz 2=-62(LC 15) Job Reference I rile Truss Go., Sumner, WA 6.010 S Apr 7 2016 MiTek Industries, Inc. Mw may 02 11:03:21 2015 Page 1 ID:O?SmbTn2K7VgBbBI?57NI1yZ6sw-08YtYH1_ByZQhsuGISSvyr350FWJRUQvCNDiuKzKZSq -2-8-0 610-1a 13-0-0 19.1-z 26-D-0 z6-8.0 r 2-8-0 1 6-10-14 i 6-1-2 6-1-2 6-10-14 Scale = 1:49.6 4x5 = 4,4 = 3x6 = 4x4 = 3x6 C 3x6 % LUMBER- 8-11-4 1M2 2x4 DF No.1 &Btr TOP CHORD Structural wood sheathing directly applied or 3-7-7 oc purlins. BOT CHORD 26-0-0 Rigid ceiling directly applied or 8-10-6 oc bracing. WEBS 8-11-0 I 8-1$ be installed during truss erection, in accordance with Stabilizer 8x11-0 Installation guide. Plate Offsets (X Y)- [2:0-3-14.0-1-8].[6:0-3-14.0-1-81 (Ib/size) 2=1216/0-5-8 (min. 0-2-0),6=1216/0-51-8 (min. 0-2-0) Max Horz 2=-62(LC 15) Max Uplift 2=-275(LC 6), 6=275(LC 7) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 25.0 Plate Grip DOL 1.15 TC 0.60 Vert(LL) -0.17 8-10 >999 360 MT20 185/148 (Roof Snow=25.0) TCDL 8.0 Lumber DOL 1.15 BC 0.57 Vert(TL) -0.37 8-10 >840 240 BCLL 0.0 Rep Stress Incr YES WB 0.25 Horz(TL) 0.10 6 We n/a Code IRC2012/TPI2007 Matrix -MSH Weight: 96 lb FT = 20% BCDL 7.0 LUMBER- BRACING - TOP CHORD 2x4 DF No.1 &Btr TOP CHORD Structural wood sheathing directly applied or 3-7-7 oc purlins. BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 8-10-6 oc bracing. WEBS 2x4 HF Stud MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2=1216/0-5-8 (min. 0-2-0),6=1216/0-51-8 (min. 0-2-0) Max Horz 2=-62(LC 15) Max Uplift 2=-275(LC 6), 6=275(LC 7) FORCES. (lb) -Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2324/459, 317=2021/375, 417=2012/394, 4-18=-2012/394, 518=2021/375, 56=-2324/460 BOT CHORD 2-10=406/2145, 9-10=-197/1460,8-9=-197/1460,6-8=-349/2145 WEBS 3-10-529/205,4-10=110/677,4-8=-110/677,5-8--529/205 NOTES- (9) 1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) V(IRC2012)=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; partially; MWFRS (envelope) gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pt --25.0 psf (flat roof snow); Category]]; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non -concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.Opsf on the bottom chord in all areas where a rectangle 36-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 275 Ib uplift at joint 2 and 275 lb uplift at joint 6. 8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet -inches -sixteenths (FFIISS) format. LOAD CASE(S) Standard May 2,2016 A WARNING - Verify design Parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Ml1-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Addlfionaf temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSVTPI1 Quality Criteria, DSB89 and SCSI1 Building Component safety Irdonnation available from Truss Plate Institute, 583 D'Onofdo Drive, Madison, WI 53719. ijeUssCO. INC. N O � a Z E N L O m E 2.2 o o� m m 3 i m E �♦wWw�,+ UOW �+ %N�NN mO dm�E@ cdN oC R t a�sc co. d .o c �yucNnUi CO c mo = mcdU 'agy3O �a3mR iovo 0 Eo E � 2 a.0 d o-� -o : .0 02 °E ca- 3v E' @ aCO 'C@_ E > 3 £ n UCoc N 00 00 1Q 3mU 0 .0 CYT �N mCca�N o ma- L NOvO@Z v aE > O a o Q E N Eay NOy UQC�Em Ca y as ZN U Uw 0 y N NOC E Nm nC O , @ @0` m OL N t C jO .8 E NRa dN y Gom N E o '2 N j -Fo nU N O vx E c E No o -`° v ti a .16 C ad w ° O u« o ac mN� _ miFE N -o 3 - a @ U Tio y m o Eo N w O� o ao N > N o mNVO OQ.No @ @y@V ROO 06:3 C >NCC0NZ Z n E.G `U@ N w O Q CU f6 LLc%J 16L6 to ems - ft FIA CIUGHO d01 tq N N T L L Z yx m m o O_ c �� 7 _ to L Q C .'C, m p Zc U m o O W O 'D ca X c--(nI'E O c,m am O m T N C a w w Z T �N- Q c: E o -C Z U Om<m (n O 0 r L w (/) a GbOHO d01 N y X ^ N � u7 C U M Al N O d Y NN 0_ o N z N ; Z c 0 y � H No N E CO Q •� N o m � W Z ao a O _� O (D W ft FIA CIUGHO d01 tq N N T L L Z yx m m o O_ c �� 7 _ to L Q C .'C, m p Zc U m o O W O 'D ca X c--(nI'E O c,m am O m T N C a w w Z T �N- Q c: E o -C Z U Om<m (n O 0 r L w (/) a GbOHO d01 m c O'U C p Y O N "O SOS C� a1 U C o U c ° o' 0 4 s c o p d 0 U o �_ - N N .19 N N O m N L N N C N 01 C C a7 a7 7 - °- p y r 0 _U O N 01- m a- 0 � 3° m oa�� Z a° o c ..c c@i-U°oar v u E O ca F- 2 m o° o c c c Co O Tom- c gamin (D� a) :` �j .- U �p 0 O � 0) F- � U O a) O p -2-6 U-6 T32h E y 0 a aUa0O C O - M 04- NU -o -2 C. x o M w E.4 c O a) m 0)0'm aaCO 0 N 00 J UC E p=o o� Fi am cco NvmCD�o m o@ Z -C -0 oC, CD m.0 doUlc0rn6 a a m e o°mZN aO cCj io w Q Q 3 L °n d Q w z U) U J m C Q Om LU U) O u7 U') 3 d Y NN 0_ z U� Z y � H OLL _ O m CO W Z _� O r0 W Q ® \ r mIT 0 N ~th V (n W W Q w CO m w O U m 0 Zz > - i W p Q > O v r; N O M m o 2 N Z O reQ Oo >.F LU Ir W� O rn Q d Nto W O Lu � w a 3� W -7-7-cam M� x�rnpr J F W W 2 Z d M Z M N j W Q m W m'7 0 00 pK2 27 C) U �M W� -,Qr Uz a Wrnzrn m c O'U C p Y O N "O SOS C� a1 U C o U c ° o' 0 4 s c o p d 0 U o �_ - N N .19 N N O m N L N N C N 01 C C a7 a7 7 - °- p y r 0 _U O N 01- m a- 0 � 3° m oa�� Z a° o c ..c c@i-U°oar v u E O ca F- 2 m o° o c c c Co O Tom- c gamin (D� a) :` �j .- U �p 0 O � 0) F- � U O a) O p -2-6 U-6 T32h E y 0 a aUa0O C O - M 04- NU -o -2 C. x o M w E.4 c O a) m 0)0'm aaCO 0 N 00 J UC E p=o o� Fi am cco NvmCD�o m o@ Z -C -0 oC, CD m.0 doUlc0rn6 a a m e o°mZN aO cCj io w Q Q 3 L °n d Q w z U) U J m C Q Om CITY OF Federal PERMIT APPLICATION PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + verrniteralway.com PERMIT NUMBER * _ I O � \/ l T FEB 2 6 2016 TARGET DATE P`T'T/ P1L ffrW\!rn A I u.A— SITE ADDRESS k PROJECT VALUATION ZONING ASSESSOR'S TAR/PARCEL 8 TYPE OF PERMIT BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT r Q PROJECT DESCRIPTION Detailed u e (.l description of work to ",r r Q f be included on this permit only 1A11. t✓ (JOSS d t S �0 ��re�c G� NAME 1,, S0 lr a� ` 1 J e -T PRIMARY PHONE p 206, - -2-7 ( PROPERTY OWNER MAILING ADDRESS E-MAIL Z03 13"6- {� a c� S CITY STATE ZIfPP_ NAME -Qr V�UucG:�v &G - 911 7-(o L MAILING ADDRESS `� E�L CONTRACTOR I Dia STATE wil ZIP 9 0)b FAX WA STATE CONTRACTOR'S LICENSE N W ee EXPIRATION DATE Z /23/ FEDERAJ. WAY U INESS LIC X -- NAME OWMARY PHO E oLA I ILI 2o(p -7 6 APPLICANT M� ING ADDRESS E-MAIL TY STATE ZIP FAX 4- w( 0 PROJECT CONTACT NAME J O lA V" III -N S PRIMARY PHONE Zo t, 547-6J46 MAILING ADDRESS E-MAIL (The individual to receive and respond to all correspondence concerning this application) CITY STATE ZIP FAX PROJECT FINANCING NAME ❑ OWNER -FINANCED When value is $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CITY, STATE, ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by including any person, the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: DATE Z' 22- 1 W PRINT NAME: Bulletin #100 -January 29, 2016 Page] of2 k:AHandouts\Permit Application X4 - City\ of Federal Way Community & Econ. Dev. Services 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: SORDAHL Project Address: 29203 13TH PL S y Building - Single Family Permit #: 16 -101017 -00 -SF Inspection Request Line: (253) 835-3050 Parcel Number: 720560 0100 Project Description: REP - Roof truss repair and drywall replacement at truss replacment due to tree damage Owner ASI' ant Contractor Lender JEFFREY A SORDAHL WHEELER RENOVATORS LLC WHEELER RENOVATORS LLC JACQUELIN SORDAHL PO BOX 587 WHEELRL861BH (2/23/18) 29203 13TH PL S BLACK DIAMOND WA 98010 PO BOX 587 FEDERAL WAY WA BLACK DIAMOND WA 98010 98003 Census Category: 434 - Residential altladd - no change in number of units Includes: # 1 42 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load Floor Areas . ft. 0 1 0 0 0 Additional Permit Information New / Additional Sq. Feet - 3rd Floor....................0 New / Additional Sq. Feet - Basement ................... 0 Calculated Structure Valuation..............................0.00 Occupancy # 1 -Construction Type .......................Type V - B Mechanical to be Included?...................................Yes Occupancy # 1 - Class ............................................. R-3 Plumbing to be Included?.......................................Yes Occupancy # 1 - Use ............................................... Residence (1 or 2 family) No Fixtums Associated With This Permit 11 CONDITIONS: ***TRUSS SPECIFICATIONS TO BE ON SITE AT THE TIME OF INSPECTION*** PERMIT EXPIRES Wednesday, August 24, 2016 Permit Issued on Friday, February 26, 2016 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: j��� Date: Z. Z G • Z6 THIS CARD IS TO REMAIN ON-SITE Federal Way THIS Inspection Record y INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 16 -101017 -00 -SF Address: 29203 13TH PL S Project: JEFFREY A SORDAHL FEDERAL WAY, WA 98003-3743 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered.until it is approved Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. Shear Walls (4245) Approved to install siding By Date 0 Mechanical Rough -in (4165) Approved By Date SWM Precon Site Mtg (4400) 0 Initial Erosion Control (4365) By Footings/Setback (4110) Floor Sheathing (4105) Approved Approved to cover To be done prior to breaking ground Approved to sheath floor Approved to place concrete By Date By Date By Date Shear Walls (4245) Approved to install siding By Date 0 Mechanical Rough -in (4165) Approved By Date Plumbing Groundwork (4190) 0 Underfloor Framing (4285) By Date Floor Sheathing (4105) Electrical, Plumbing & Mechanical Rough -in and Approved to cover Gas Piping (4125) Approved to sheath floor Approved to release test By Approved to install flooring By Date By Date By Date Shear Walls (4245) Approved to install siding By Date 0 Mechanical Rough -in (4165) Approved By Date Roof Sheathing (4220) Prior to scheduling a Framing inspection; Approved to install roofing By Date Approved Electrical, Plumbing & Mechanical Rough -in and El Gas Piping (4125) By Approved to release test By Date Rough Plumbing (4230) Prior to scheduling a Framing inspection; Approved By Date Approved Electrical, Plumbing & Mechanical Rough -in and ❑ Fire/Draft Stops (4095) By Approved By Date Interim Erosion Control (4370) Prior to scheduling a Framing inspection; Framing g (4120 ) Approved Electrical, Plumbing & Mechanical Rough -in and By Approved to insulate By Date Fire/Draft Stop inspections must be signed -off and By Date Date approved. IBC 109.3.4 Insulation (4150) ❑ Gypsum Wallboard Nailing (4130) Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By Date By Date By Date Final - Mechanical (4065) E:] Final - Plumbing (4075) Final - Building (4050) Approved Approved Approved By Date By Date By Date Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date