14-105147z . Electrical
Permit #: 14 -105147 -00 -EL
Inspection Request Line: (253) 835-3050
Project Name: HOME DEPOT
Project Address: 1715 S 352ND ST
Project Description: Job#871410-12 Alter one circuit to add appliance kiosk
Parcel Number: 282104 9008
Owner
li n
CIV of Federal Way
Community & Econ. Dev. Services
HD DVLPMT OF MARYLAND INC
33325 8th Ave S
FILE
Federal Way, WA 98003
E C COMPANY
Ph: (253)835-2607 Fax: (253) 835-2609
ATLANTA GA 30348
z . Electrical
Permit #: 14 -105147 -00 -EL
Inspection Request Line: (253) 835-3050
Project Name: HOME DEPOT
Project Address: 1715 S 352ND ST
Project Description: Job#871410-12 Alter one circuit to add appliance kiosk
Parcel Number: 282104 9008
Owner
li n
Contractor
HD DVLPMT OF MARYLAND INC
KATHY WOOD
E C COMPANY
PO BOX 105842
E C COMPANY
ECCOM**148BA (6/30/16)
ATLANTA GA 30348
6412 S 196TH ST
2121 NW THURMAN
KENT WA 98032
PORTLAND OR 98002
Additional Permit Information
Is this an Online or O.T.C. application?.................Yes Is Use Educational or Institutional?....................... No
Service greater than 999 Amps? .............................No
Circuits - Commercial .................... 1
PERMIT EXPIRES Saturday, April 4, 2015
Permit Issued on Monday, October 6, 2014
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and the City of Federal Way.
Owner or agent: AUC Date:
F,NA�ED
11
0 THIS CARD IS TOrection
ON-SITE
C,r~oF Construction InRecord
Federal Way INSPECTION REQU3) 835-3050
PERMIT #: 14 -105147 -00 -EL Address: 1715 S 352ND ST
Project: HD DVLPMT OF MARYLAND INC FEDERAL WAY, WA 98003-8316
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
. Ground (4295) Ditch cover (4030) 110 h1ab/Uoncrete inoor (.
Approved Approved Approved to place concrete
By Date I I By Date I I By Date
❑ Final - Electrical (4055)
Approved
By NM, Date 10 it
Pool Bonding (4195)
Temporary Power (4275)
Service (4235)
By
Approved
By
Approved
By
Approved
By
Date
By
Date
By
Date
E:]
Ceiling Cover (4020)
Rough Electrical (4225)
Feeders/Sub-panels (4045)
Approved
Approved
Approved
By
Date
By
Date
By
Date
❑ Final - Electrical (4055)
Approved
By NM, Date 10 it
Rough ElectricalE]Final
Approved
Electrical
Approved
Right of Way
Approved
By
Date
By
Date
By
Date