93-102597, -r
CITY OF FEDERAL WAY
33530 First Way South
Federal Way, WA 98003
661-4000
BUILDING PERMIT
Building Inspection Requests 661-4140
,ADDRESS:926 SW 313TH CT
NO.: 555990-0010
PROJECT DESCRIPTION:NSF AT LOT 110, MIRROR LAKE TERRACE
` ONNER CONTRACTOR
PACIFIC HUTS AND CASTLES PACIFIC HUTS i CASTLES, INC
1420 N.N. GILMAN BLVD. #2272 1420 NN GILMAN BLVD #2272
ISSAQUAH NA 98027 ISSAQUAH NA 98027
05 392-6940
206-392-9105
PACIFHC105K4
LENDER
9 3 - 10..5 9;7
PERMIT NO: BLD93-1085
ISSUED: 11/23/93
BY: FC
EXPIRES: 05/22/94
BLD?:X NEC?:X
PLM?:X
FLR--EXIST--PROP---
DNELLING UNITS: 1
COMP PLAN ......... :SR
FEES:
TYPE OF NORK:NEN
USE:RES
1ST.: 0: 918:sf
STORIES........: 2
REQUIRED PARKING..:
4
SPRINKLERS?......:?
PLAN CHECK DEPOSIT.=
S
447.53
CENSUS CATEGORY ..... :101
2ND.: 0: 732:sf
HEIGHT.....: 0.00 ft
HAZARD CLASS...:?
FINAL PLAN CHECK...*
=
0.00
OCCUPANCY GROUP----------
3RD.: 0: O:sf
VALUATION----------
REQUIRED SETBACKS-------
FIRE FLON....:
0 9pe
BUILDING PERMIT....*
=
688.50
:R3 :? :?
:?
OTHR: 0: O:sf
EXIST..$: 0
FRONT.........:
20.00 ft
SBCC SURCHARGE.....*
$
4.50
TYPE OF CONSTRUCTION-----
BSMT: 0: O:sf
PROP ... =: 113996
SIDE..........:
10.00 ft
NATER SERVICE..:FED
NEC APPLIANCE FEES.*
S
44.00
:5N :? :?
:?
DECK: 0: O:sf
REAR..........:
10.00:ft
SEVER SERVICE..:FED
PLUMBING FIXT.... 93S
$
98.00
OCCUPANT LOAD------------
GAR.: 0: 400:sf
RECEIVED.: 10/12/93
RADON KIT ......... 93
$
20.00
0: 0:
0: 0:
TOTL: 0: 2050:sf
INPERV SURFACE:
0 sf
SENSITIVE AREAS?.:N
PUB MKS PLCK(SF)..93
#
40.00
FINAL PLAN CHECK ... t
$
30.00
FUEL TYPES.:GAS
?
FANS..........: 4
BOILERS/COMPRESSORS
MATER CLOSETS......:
3
URINALS........:
0
TOTAL FEES
=
1372.53
GAS PIPING.: 35
ft
HOOD..........: 1
0-3 HP......: 0
BATH TUBS..........:
1
DRINKING FOUNT.:
0
N<100K..: i
DUCT NORK.....: 0
3-15 HP.....: 0
SHOVERS ............:
1
SUMPS..........:
0
NMT....: 1
NOOD STOVES...: 0
15-30 HP....: 0
LAVATORIES.........:
3
VAC BREAKERS...:
0
CONV BURNER: 0
FURN>100K.....: 0
30-50 HP....: 0
SINKS ..............:
4
DRAINS.........:
0
BBQ........: 0
MISC..........: 0
5+ HP.......: 0
DISH MASHERS.......:
1
LANK SPRINKLERS:
0
GAS DRYER..: 0
AIR HANDLING UNITS
FUEL TANKS---------
ELEC NTR HEATERS...:
0
OTHER FIXTURES.:
0
RANGE......: 0
<=10,000 CFM: 0
ABOVE GROUND: 0
LAUN NSHR OUTLTS...:
1
GAS LOGS...: 0
> 10,000 CFM: 0
UNDERGROUND.: 0
PERMITS EXPIRE 180 DAYS AFTER ISSUANCE IF NO NORK IS STARTED. RESIDENTIAL AND GRADING PERMITS EXPIRE ONE YEAR AFTER DATE OF ISSUANCE.
I CERTIFY THAT THE INFORMATION FURNISED BY ME IS TRUE AND CORRECT TO THE BEST OF MY KNONLEDGE AND THE APPLICABLE CITY OF FERERAL NAY REQUIREMENTS MILL BE NET.
OWNER OR AGENT ,"y/rt�
FILE COPY
DATE ------
Ar
A&
A
Name (F,M,L)
PACIFIC HUTS & CASTLES, INC.
Address
1420 N.W. Gilman BLVD. #22.72.
city ISSA UAH State WA Zip 9802.7
Contact Person Dey Phone Other Phone Fax
Greq Quinn _ (2.06)392-9105 (206)392-8940 392-9325
Company Nome
PACIFIC HUTS & CASTLES, INC.
Address '
1420 N. W. Gilman BLVD. #2272
City
State WA Zip 98027
Contact Person Bruce Burnett P70� 6) 392-9105 Fa 3 9 2- 9 3 2 5
Contractor's +/ (card must be presented) Expiration Date Verified O Yes 0 Nr
PACIFHC105K4 5/94
Name
STENSTROM DESIGN ---
Address
P. O. Box 31
City REDMOND State WA Zip 98073
Contact Person Phone Fax
Mark Stenstrom (206)869-7241
LEGAL DESCRIPTION
The south half of the northeast quarter of the northeast quarter of
the southwest quarter of Section 7, Township 2.1 North, Range 4 East,
Willamette Meridian, in King County, Washington.
Please Complete Reverse Side
CDo192 Mev
IF City of Federal Way
APPLICATION FOR
BUILDING PERMIT
,� 1993
6
CITY OF FEDERAL WAY
BUILDING
�J V111 % wn_ 16f
DEPT.i
PLEASE PR/NT
APPL/CAT/ON Ar:
SITE LOCATION
Address
Tenant (if known)
Lot
lG'
Assessor's Tax y
-4C o - 0/(0 r
Building Owner Name
PACIFIC HUTS &
CASTLES
Address
1420 N.W. Gilman
BLVD. #2272
City I S SAQUAH
State WA
Zip 98027
Phone ( 2.0 6) 3 9 2- 910 5
Nature of Work New residential construction -
single family
A
Name (F,M,L)
PACIFIC HUTS & CASTLES, INC.
Address
1420 N.W. Gilman BLVD. #22.72.
city ISSA UAH State WA Zip 9802.7
Contact Person Dey Phone Other Phone Fax
Greq Quinn _ (2.06)392-9105 (206)392-8940 392-9325
Company Nome
PACIFIC HUTS & CASTLES, INC.
Address '
1420 N. W. Gilman BLVD. #2272
City
State WA Zip 98027
Contact Person Bruce Burnett P70� 6) 392-9105 Fa 3 9 2- 9 3 2 5
Contractor's +/ (card must be presented) Expiration Date Verified O Yes 0 Nr
PACIFHC105K4 5/94
Name
STENSTROM DESIGN ---
Address
P. O. Box 31
City REDMOND State WA Zip 98073
Contact Person Phone Fax
Mark Stenstrom (206)869-7241
LEGAL DESCRIPTION
The south half of the northeast quarter of the northeast quarter of
the southwest quarter of Section 7, Township 2.1 North, Range 4 East,
Willamette Meridian, in King County, Washington.
Please Complete Reverse Side
CDo192 Mev
STRUCTURE g use Vacant
Permit includes: Building 1 Plumbing
Type of Work: }t<}( Residential New ❑ Remodel
❑ Commercial ❑ Addition ❑ Garage
Enter 1 at Floor q1 f7� sq ft 2nd Floor ? 1. sq ft 3rd Floor sq ft
Area Basement sq ft Decks sq ft Garage i aq ft
Water Availability ❑ Sewer Availability ❑ On -Site Septic System Availability ❑
Zoning I Lot Size 6 Liv�
MOhnosad Use Single Family Res .
Mechanical ❑ Other
❑ Number of Units _ ❑ Deck
❑ Shed ❑ Other
Existing Floor Area aq ft
Proposed Total Area '7 t )r_,"C> sq ft
Project Valuation i t _
Existing Bldg Valuation I $
Name Address
EXECUTIVE HOUSE 7517 Greenwood Ave. N.
City SEATTLE State WA IMP 98103
NIECHANICAL CONTRACTOR
Contractor Nems Address
PP & S HEATING & AIR CONDITION P. O. Box 945
City ISSA UAH State WA Zip 98027
Contact
Phone
ax
Dick J. Person (206)392-798 391-9372
License i1 PPSHEA* 13 3DA Expiration Date 3 / 94 1 Verified ❑ Yes ❑ No
PLUNI BING CONTRACTOR
Contractor Name BATES PLUMBING, , INC.
Addres 14522 N.E. 19 0th #105-A
City State WAZip 98072
Contact Phone Fax
Merrill M (206)485-2260 624-1883
License X BATES I * 2 24 BK Expiration Date 1/94 Verified ❑ Yes ❑ No
PLUMBINGFIXTURE COUNT
Water Closets Sinks
Bathtubs Dish Washers
Showers Electric Water Heaters
Lavatories Washing Machine
MECHANICAL UNIT COUNT
Urinals
Drinking Fountains
Sumps
Drains
Lawn Sprinklers
Other
xture Count i
Fuel Type (electric/other)
FAS
Gas Dryer
Air Handling < - 10,000 CFM
15-30 Tons
Length of Gas Piping
Range
Air Handling > - 10,000 CFM
30-50 Tons
Furn <100K BTUs
Gas Log
Unit Heater
50+ Tons
Furn > 100 BTUs
(
Fans 4
Miscellaneous
Fuel Tanks
Gas Hwt
Hood
Boilers
Above Ground
Conv Burner
Duct Work
0-3 Tons
Underground
BBQ's
Wood Stoves
3-15 Tons
Total Unit Count
DISCLAIMER: I certify under penalty of perjury that the Information furnished by me is true and correct to the best of my knowledge and further that I am authorized by the ow
of the above premises to perform the work for which permit application is 'e. 1 further agree to save harmless the City of Federal Way as to any claim (including costs, expen,
and attorneys' fees incurred in investigation and defense of such cWm), may be made by any person, Including the undersigned, and filed against the City of Federal 'A
but only where such claim ari of the reliance of the City, int -ing its officers and employees, upon the accuracy of the information supplied to the City as a part of
application.
7
Owner/Agent: Dater .
( i
CITY OF FEDERAL WAY
33530 First Way South
Federal Way, WA 98003
661-4000
BUILDING PERMIT
Building Inspection Requests 661-4140
ADDRESS:926 SW 313TH CT
NO.: 555990-0010
PROJECT DESCRIPTION:NSF AT LOT #10, MIRROR LAKE TERRACE
REVISION RECD 2/8/94 TO INCLUDE DECK.
L14
NER CONTRACTOR
CIFIC HUTS AND CASTLES PACIFIC HUTS K CASTLES, INC
20 N.M. GILMAN BLVD. 12272 1420 NM GILMAN BLVD #2272
SAQUAH NA 98027 ISSAQUAH NA 98027
392-9105 392-8940
206-392-9105
PACIFHC105K4
LENDER
PERMIT NO: BLD93-1085
ISSUED: 11/23/93
BY: FC
EXPIRES: 05/22/94
** REVISED PERMIT **
BLD?:X MEC?:X
PLM?:X
FLR--EXIST--PROP---
DWELLING UNITS: 1COMP
PLAN.........:SR
FEES:
TYPE OF NORK AEW
USE AES
1ST.: 0: 918:sf
STORIES........: 2
REQUIRED PARKING..:
4
SPRINKLERS?— ....:?
PLAN CHECK DEPOSIT.*
$
447.53
CENSUS CATEGORY.....:
101
2ND.: 0: 132:sf
HEIGHT.....: 0.00 ft
HAZARD CLASS...:?
FINAL PLAN CHECK ... $
$
0.00
OCCUPANCY GROUP----------
3RD.: 0: O:sf
VALUATION----------
REQUIRED SETBACKS-------
FIRE FLOW....:
0 9pe
BUILDING PERMIT....*
$
688.50
:R3 :? :?
:?
OTHR: 0: O:sf
EXIST..$: 0
FRONT.........:
20.00 ft
SBCC SURCHARGE.....*
$
4.50
TYPE OF CONSTRUCTION-----
BSMT: 0: O:sf
PROD -3: 115052
SIDE..........:
10.00 ft
WATER SERVICE..:FED
NEC APPLIANCE FEES)
P;
44.00
:5N :? :?
:?
DECK: 0: 120:sf
REAR..........:
10.00:ft
SEWER SERVICE..:FED
PLUMBING FIXT.... 93*
$
98.00
OCCUPANT LOAD------------
GAR.: 0: 400:sf
RECEIVED.:10/12/93
RADON KIT ......... 93
$
20.00
0: 0:
0: 0:
TOTL: 0: 2170:sf
IMPERV SURFACE:
0 sf
SENSITIVE AREAS?.:N
PUB WKS PLCK(SF)..93
$
40.00
---
Additional fees not
shown
here...
UEL TYPES.:GAS
?
FANS..........: 4
BOILERS/COMPRESSORS
WATER CLOSETS......:
3
URINALS........:
0
TOTAL FEES
E
1417.08
PIPING.: 35
ft
HOOD..........: 1
0-3 HP......: 0
BATH TUBS..........:
i
DRINKING FOUNT.:
0
URN<100K..: i
DUCT WORK.....: 0
3-15 HP.....: 0
SHOWERS ............:
1
SUMPS..........:
0
6AS HWT....: 1
WOOD STOVES...: 0
15-30 HP....: 0
LAVATORIES.........:
3
VAC BREAKERS...:
0
CONY BURNER: 0
FURN>100K.....: 0
30-50 HP....: 0
SINKS ..............:
4
DRAINS.........:
0
BBQ........: 0
MISC..........: 0
5+ HP.......: 0
DISH WASHERS.......:
1
LAWN SPRINKLERS:
0
GAS DRYER..: 0
AIR HANDLING UNITS
FUEL TANKS---------
ELEC NTR HEATERS...:
0
OTHER FIXTURES.:
0
RANGE......: 0
<:10,000 CFM: 0
ABOVE GROUND: 0
LAUN WSHR OUTLTS...:
1
GAS LOGS...: 0
> 10,000 CFM: 0
UNDERGROUND.: 0
PERMITS EXPIRE 180 DAYS AFTER ISSUANCE IF NO WORK IS STARTED. RESIDENTIAL AND GRADING PERMITS EXPIRE ONE YEAR AFTER DATE OF ISSUANCE.
I CERTIFY THAT THE INFORMATI N FUR SED BY ME IS TRUE AND C RECT TO THE BEST OF MY KNOWLEDGE AND THE APPLICABLE CITY OF FERERAL NAY REQUIREMENTS WILL BE MET.
OWNER OR AGENT------------�-- ----------- ------------------------------------------
FILE COPY
Permit #
9 4 n 1; v i a i ON-DffE.
F FEDERAL CITY O AL WAY FEB 0 8 1994
BUILDING PERMIT APPLICATION
— Please Print — 9&0
3
80X 1)TENANT NAME:
OWNER i r1' S Q . SITE LOCATION
OWNER'S ADDRESS CITY (Aa // PHONE
DESCRIBE JOB 1-710
THE PROPERTY IS OWNED BY: SINGLE/MARRIED PARTNERSHIP CORPORATION
ONTRACTOR'S NAME
CONTRACTOR'S ADDRESS
EXPIRATION DATE
-1.61C_ CONTRACTOR'S REG. #
CITYZ2 -7
ZSCr4-Jk
1 X16 z, _-?
PHON
Card MUST be presented
z:�, .. _-1 ` V/�
I HAVE READ CHAPTER 18.27.010 RELATING TO DEFINITIONS OF GENERAL CONTRACTORS AND SPECIALTY CONTRACTORS AND
CHAPTER 18.27.110 WHICH PROHIBITS ISSUING PERMITS WITHOUT PROOF OF REGISTRATION.
OX 3.1CONTACT PERSON %St�'t c�!%'J� T PHONE_
BOX 4 SEWER DISTRICT WATER DISTRICT
BOX–5 ESTIMATED PROJECT COST EXISTING BUILDING VALUATION
OX 6- PROPERTY TAX ACCOUNT NUMBER
LEGAL DESCRIPTION _?—
(If necessary, please submit a separate page with the legal description.)
K.C. Plat Recording #
BOX 7 BUILDING SQUARE FOOTAGE: (Existing/Proposed) 1ST FLOOR 2ND FLOOR /
3RD FLOOR / BASEMENT / 'DE CKJ / /2 ci GARAGE /
BOX 8 SINGLE FAMILY ( ) NEW CONSTRUCTION
( ) MULTIFAMILY (NO. OF UNITS = ) ( ) EXISTING STRUCTURE
( ) COMMERCIAL/INDUSTRIAL TOTAL AREA OF PROPERTY _SQ FT
it •
PLUMBING FIXTURES (including rough -ins)
N0. WATERCLOSETS
BATHTUBS
SHOWERS
LAVATORIES
SINKS
DISHWASHERS
ELECTRIC HOT WATER HEATER
LAUNDRY WASHER OUTLET
URINALS
DRINKING FOUNTAINS
SUMPS, SPRINKLER VACUUM BREAKERS
DRAINS
__OTHER
TOTAL FIXTURES
MECHANICAL APPLIANCES — BASIC FEE $
GAS PIPING, FEET $
N0._ FURNACE, ELEC. GAS $
GAS HOT WATER HEATER $
CONVERSION BURNER"� $
BOILER, SIZE BTU/v /4- $
AIR HANDLING UNITS $
HEAT PUMPS, SIZE $
UNIT HEATERS $
AIR COOLING UNITS, SIZE $
COMMERCIAL HOOD $
OTHER $
TOTAL MECHANICAL FEE $
I CERTIFY UNDER PENALTY OF PERJURY THAT THE INFORMATION FURNISHED BY ME IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE
AND FURTHER THAT I AM AUTHORIZED BY THE OWNER OF THE ABOVE PREMISES TO PERFORM THE WORK FOR WHICH PERMIT APPLICATION IS
MADE. I FURTHER AGREE TO SAVE HARMLESS THE CITY OF FEDERAL WAY AS TO ANY CLAIM (INCLUDING COSTS, EXPENSES, AND ATTORNEYS -
FEES INCURRED IN INVESTIGATION AND DEFENSE OF SUCH CLAIM), WHICH MAY BE MADE BY ANY PERSON, INCLUDING THE UNDERSIGNED,
AND FILED AGAINST THE CITY OF FEDERAL WAY, BUT ONLY WHERE SUCH CLAIM ARISES OUT OF THE RELIANCE OF THE CITY, INCLUDING ITS
OFFICERS AND EMPLOYEES, UPON THE ACCURACY OF THE INFORMATION SUPPLIED TO THE CITY AS A PART OF THIS APPLICATION.
R/AGENT:
DATE:
ANP iii" _ _
CITY OF FEDERAL WAY
33530 First Way South
Federal Way, WA 98003
661-4000
BUILDING PERMIT
Building Inspection Requests 661-4140
ADDRESS:926 SW 313TH CT
NO.: 555990-0010
PROJECT DESCRIPTION:MSF AT LOT 110, MIRROR LAKE TERRACE
REVISION RECD 2/8/94 TO INCLUDE DECK.
- ONNER - _- CONTRACTOR
PACIFIC HUTS ANO CASTLES PACIFIC HUTS i CASTLES, INC
1420 N.H. GRNAN BLVD. 12272 1420 NN GILMAN BLVD 12272
e�=SSAQUAK NA 96027 ISSAQUAH NA 98177
392-9105 392--8940
BLD?:X MEC?:X PLN?:X FLR--EX ROP ---
TYPE Of NORK AEN USE:RES IST.: 918:
CENSUS CATEGORY ..... :101 71� 73 a
�.
OCCUPANCY GROUP------- -
A3 :? :? :?
TYPE OF CONSTRUCTION -----
:5N :? :? :?
OCCUPANT LOAD------------
G: 0: 0: 0: TO T .s
FUEt TYPES. -GAS ?
'45 PIPING.: 35 ft
FURM<100K..: i
GAS HNT....: I
CONY BURNER: 0
B5Q........ - 0
GAS DRYER-: 0
RANGE......: 43
GAS LOGS...: 0
FANS... T...... TU
HOOD........... I
DUCT NORK..... : 0
WOOD STOVES...: 0
TURN>IoOK..... : 0
RISC..........: 0
AIR HANDLING UNITS
<:10.000 CFN: 0
> 10,000 Cf N: 0
206-392-9104
LENDER
BOILLRS/COAPRESSORS
0--3 HP......: 0
3-15 KP.....: 0
15-30 HP...': 0
30-50 HP..... 0
St HP. 0
FUEL --_-
ABOVE GROUND: 0
UNDERGROUND.. 0
1MPERV SURFACE: 0 sf SENSITIVE AREAS?.:N
NATER CLOSETS......: 3
BATN TUBS..........: 1
SWAIERS............: I
LAVATORIES.......... 3
SINKS ..............; 4
DISK MASHERS.......: I
ELEC NOR HEATERS...: 0
LAURA WSHR OUTLTS...: I
URINALS........: 0
DRINKING FOUNT.: 0
SUMPS........... 0
VAC BREAKERS—; 0
DRAINS........... 0
LAWN SPRINKLERS: 0
OTHER FUTURES.: 0
PERMIT NO: BLD93-1085
ISSUED: 11/23/93
BY: FC
EXPIRES: 05/22/94
P
FEES:
PLAN CHECK DEPOSIT.* 1 447.53
FIRM PIAN CHECK...* S 0.00
BUILDING PERMIT....* S 688.50
i HARGE.....1 $ 4.50
NEC APPLIANCE FEES.* f 44.40
PLUMBING FIXT.... 93* S 98.00
RADON KII......... 93 $ 20.00
PUB MKS PLCK(Sf)..93 1 40.00
Additional fees not stamen teem...
TOTAL FEES S 1417.08
PERMITS EXPIRE 180 DAYS AFTER ISSUANCF IF NO NORK IS STARTED. RESIDENTIAL AND GRADING PERMITS EXPIRE ONE YEAR AFTER DATE Of ISSUANCE.
I CERTIFY THAT THE INfORMATIN FUR SED BY ME IS TRUE AND CORRECT TO THE BEST Of MY INOItEDGE AND iKE APPLICABLE CITY Of FEREPAL NAY REQUIREMENTS NILL BE NFT.
r _ `
OWNEk OR AGE N1
CQ' P PtAN.......... SR
�
�U,RFD PARKING..:
4
SPRINKLERS?
�
�F
.�. _
REQ. EU ;08ACE�-
I
-
SOD;.. .....:
10.00 ft
NATER SERVICE..:FED
„)
..........:
10.00:ft
SEVER SERYICE..;fED
BOILLRS/COAPRESSORS
0--3 HP......: 0
3-15 KP.....: 0
15-30 HP...': 0
30-50 HP..... 0
St HP. 0
FUEL --_-
ABOVE GROUND: 0
UNDERGROUND.. 0
1MPERV SURFACE: 0 sf SENSITIVE AREAS?.:N
NATER CLOSETS......: 3
BATN TUBS..........: 1
SWAIERS............: I
LAVATORIES.......... 3
SINKS ..............; 4
DISK MASHERS.......: I
ELEC NOR HEATERS...: 0
LAURA WSHR OUTLTS...: I
URINALS........: 0
DRINKING FOUNT.: 0
SUMPS........... 0
VAC BREAKERS—; 0
DRAINS........... 0
LAWN SPRINKLERS: 0
OTHER FUTURES.: 0
PERMIT NO: BLD93-1085
ISSUED: 11/23/93
BY: FC
EXPIRES: 05/22/94
P
FEES:
PLAN CHECK DEPOSIT.* 1 447.53
FIRM PIAN CHECK...* S 0.00
BUILDING PERMIT....* S 688.50
i HARGE.....1 $ 4.50
NEC APPLIANCE FEES.* f 44.40
PLUMBING FIXT.... 93* S 98.00
RADON KII......... 93 $ 20.00
PUB MKS PLCK(Sf)..93 1 40.00
Additional fees not stamen teem...
TOTAL FEES S 1417.08
PERMITS EXPIRE 180 DAYS AFTER ISSUANCF IF NO NORK IS STARTED. RESIDENTIAL AND GRADING PERMITS EXPIRE ONE YEAR AFTER DATE Of ISSUANCE.
I CERTIFY THAT THE INfORMATIN FUR SED BY ME IS TRUE AND CORRECT TO THE BEST Of MY INOItEDGE AND iKE APPLICABLE CITY Of FEREPAL NAY REQUIREMENTS NILL BE NFT.
r _ `
OWNEk OR AGE N1
r
I
CkTY OF FEDERAL WAY
33530 First Way South
Frederal Way, WA 98003
961-4000
PERMTT NO: BLD93-1085
B UILDING PERMIT ISSUED: 11/2Z/93
Building Inspection Requests 661-4140 BY: FC
EXPIRES: 05/22/94
ADDRESS:926 SW 313TH CT
NO.: 555990-0010
PROJECT DEcl'CRIPTTON:NSf AT COT 1110, MIRROR tAKF TERRACE
OWNER- — — - - - - - ........ CONTRACTOR
PACIFIC BUTS AND CASTLES PACIFIC HUTS & CASTLES, INC
1420 N.O. GILMAN 8(VD. 12272 1420 NV GILMAN BLVD 12272
ISSA"I'l VA 98021 ISW"H #A 98027
-9105 397-8940
206-392-9105
PACIFHCIGSK4
BLD?: X MEC?:X P[R?:X
f71 Eiirf-
i
TYPE Of NORK:NFV USE:RES
IST.: O"NJ
•l
CENWS CATEGORY ..... :101
7 1) 7 3 2- S f4
I'po"T, f'q ft
OCCUPANCY GROUP----------
V 0 -
:R3 -? :? :?
TYPE Of CONSTRUCT [ON----
f
PiOPT
-1-1137: Y
A114"I"O'k, 0,
OCCUPANT LOAD------------
o l
Jl40
RE - Tv'r
0: 0: 0.
FUEL TYPES.:GAS ?
FANS
BOILERS/COMPRESSORS
GAS PIPTNG.: 35 ft
*1111000K. -: I
#m'-
DUCT WORK.....: 0
0-3 4P....... 0
3-15 UP. 0
GAS NMT....: I
WOOD STOVES...: 0
15-0 Ill 0
CORY BIJRNFR: 0
FURN>1009 ..... 0
30-50 HP....: 0
ON.. . ....... 0
0
5+ NP.,....., 0
GAS DRYER..: 0
AIR HANDLING UNITS
FUEL TANKS---------
NKS---------
RANGE......: 0
RANGE......:
<:10,000 Cf": 0
ABOVE GROUND: 0
GAS LOGS...: 0
> 10,000 CFM: 0
UNDERGROUND.: 0
I ,- ---
- -- -
t'JAP PLAN ......... :SR
Pfl)UIRED PAPXING..; 4
- LENDER
SPRINKLERS?......:?
HUARD CLASS...:?
NATIR 104m: f FO
SEVER SFRVICE..:ffD
SURFACE: 0 st SENSITIVE AREAS?.:N
WATER CLOSETS......: 3
Ulm (ties....... .. I
SHOWER .............. I
LAVATORIES........:: 3
SINKS ............... * 4
DISH WASHERS.......: I
ELEC ITR HEATERS...: 0
LAUN VSHR OUfLTS ... I
IIRINALS . ...... : 0
DRINKING FOUNT.: 0
SUMPS..........: 0
VAC BREAKERS...: 0
DRAINS.......... I
LAWN SPRINKLERS: 0
OTHER FUTURES.: 0
FEES:
PLAN CHECK DEPOSIT.* t 447.53
f1dAl. PLAN CHECK ... 4 1 0.00
BUILDING PERMIT .... I $ 688.50
SKC SURCNw ..... 8 $ 4.50
WANCE FEES.$ = 44.00
PLUMBING FIXT....930 Ill 98.0.
RADON KIT ......... 93 1 20.00
PUB NKS PLCK(SF)..93 1 40,00
FINAL PLAN CNECI ... 30.00
TOTAL FEES 1372.53
PERMITS EXPIRE 180 DAY" AFTER ISSUANCE IF NO NORk IS STARTED, RESIDENTIAL AND GRADING PERMITS EXPIRE ONE YEAR AFTER DATE Of ISSUWI.
I CERTIFY THAT THE INFORMATION fURNISED BY HE IS IFUE AND CORRECT TO THE REST Of MY KNONtlKir AND THE APPLICABLE CITY Of FERFRAI WAY RFWIRFNfNIS WILL Of VEL
w/4
f0fp OP 4GENT
FIELD COPY
I
G
r
SETBACKS & FOOTINGS
Date -- s 3
By
FOUNDATION WALLS
Date ``iBy
PLUMBING>GROUNDWORK
Date
By
UNDERFLOOR FRAMING
Date % ?j
By
$HEAR WALL$
Date - , 1 L/
By
PLUMBING ROUGH -IN
Date 2
By
GAS PIPING
Date = y
By
MECHANICAL ROUGH -IN
Date .,, �� �'0 q
By
MECHANICAL (OTHER)
Date
By
FRAMING
Date l-� ��
By
INSULATION
Date (" �1
By
GWB - 1ST LAYER
Date -
By
GWB - 2ND LAYER
Date -- pi — ltl
By
SUSPENDED CEILING
Date
By
PLANNING FINAL
Date
By
ENGINEERING FINAL
Date
By
FIRE FINAL
Date
By
BUILDING FINAL
Date r i
OT R
Date
By
OTHER
Date
By
CDO193