18-103989City of Federal Way C-ty Development DepL 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax (253) 935-2609 Project Name: ESTRADA I - Demolition Permit #:18 -103989 -00 -DE Inspection Request Line: (253) 835-3050 Project Address: 3001 S 288TH ST *r-3&0 Parcel Number: 042104 9155 Project Description: Complete demolition of fire damaged mobile home in park. Owner Applicant Contractor IVET'PE ESTRADA IVETTE ESTRADA OWNER IS CONTRACTOR 3001 S 288TH ST UNIT 356 3001 S 288TH ST UNIT 356 FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 Additional Permit Information PERMIT EXPIRES Sunday, 24 February, 2019 Permit Issued on Tuesday, August 28, 2018 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. 66'' Owner or agent: Date: r RECEIVED ` PERMIT APPLICATION CITY OF AUG 2 a 201s PERMIT CENTER + 33325 81h Avenue South +Federal Way, WA 98003-6325 Federal Way CITY OF FEDE��. WAY 253-835-2607 + FAX 253-835-2609 + permitcenter@cityoffederalway.com COMMUNITY ® LKENT' TARGET DATE SITE ADDRESS SUITEMNIT # aa 300 4 PROJECT VALUATION ZONING ASSESSOR'S TAR/PARCEL # TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL EMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT PROJECT DESCRIPTION Detailed description of work to \ be included on this permit only NAME PRIMARY PHONE nn PROPERTY OWNER MAILING ADDRElkS 3 \ �p\I 3 46) CITY Aw"vV STATE ZIP ® Um _ AME PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # NAME ®� � � � PRIMARY PHONE MAILING ADDRESS WRIAD. APPLICANT- CITY STATE ZIP FAX PROJECT CONTACT NAME A v �\ e x- � � PRIMARY PHONE MAILING ADDRESS E-MAIL (The individual to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) PROJECT FINANCING NAME ❑ OWNER -FINANCED When value is $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CITY, STATE, ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: CA DATE PRINT NAME: U Bulletin #100 — January 29, 2016 Page 1 of 2 k:\Handouts\Permit Application VALUE OF MECHAMCAL WORK MECHANICAL PERMIT Indicate how many o eache offlxture to be installed or relocated as part o this project..Do not include e.)dstingfixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe), AIR CONDITIONER FIREPLACE INSERTS HOODS (commercial) BOILERS FURNACES HOT WATER TANKS (ate) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES PLUMBING PERMIT VALUE OF PLUMBING WORK .r Indicate how man of each type offixture to be installed or relocated as part of this project. Do not include wdstingfixtures to remain. BATHTUBS (or Tub/shower combo) LAVS (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS ❑ Yes ❑ No DRINKING FOUNTAINS SINKS (Kitchen/uniity) WATER HEATERS (electric) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIRTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PIIRVEYOR VALUE OF EMSTING DU%OVEMENTB Construction Additional Information EBISTING/PREVIOUS USE LOT SIZE (In Sgwwe Feet) FMSMG FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? BUILDING ❑ Yes ❑ No ❑ Yes ❑ No COMMERCIAL - NEW/ADDITION AREA DESCRIPTION Area in Occupancy Group(s) Construction Additional Information Feet SquareNEW St roses BUILDING ADDITION COMMERCIAL - REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet Stories TOTAL BUXLDING TENANT AREA ONLY 1� A� ONL7i Bulletin #100 —January 29, 2016 Page 2 of 2 k:\Handouts\Pemlit Application 41k CITY OF mow, federal Way COMMUNITY DEVELOPMENT DEPARTMENT 333258 1h Avenue South Federal Way, WA 98003 253-835-2607; Fax 253-835-2609 www.ciiyoffederalwLty.com DEMOLITION PERMIT REQUIREMENTS A demolition permit is required to remove any structure on a subject property. Demolition of separate structures may require separate permits. ❑ Address of Demolition: ❑ Prior to submitting a demolition permit, the following items must be signed by the respective agency or their approvals attached. Items not applicable to your project should be marked N/A. ❑ A completed Construction PermitAppiication form is also required. 1. ASBESTOS ABATEMENT (Provide copy of Notice oflntentfrom Puget Sound Clean Air Agency & ELECTRICITY and copy of inspection report by AHERA-certified inspector) 6 ( c4cd 6 1 of Federal Way Building Official) (Puget Sound Energyoma Power) 2. FUEL STORAGE TANKS 6. NATURAL GAS ❑ Under grade tank(s) is/are present NIA ❑ Above grade tank(s) are present I ❑ Tank(s) has been pumped or removed under South King Fire & (Puget Sound Energy) Rescue permit prior to any dismantling or excavation KJ Z (South King Fire and Rescue) 7. WATER - Public Source 56- "&_r_ko_J' 4 (Lakehaven Utility District) 3. SEPTIC SYSTEM N / /+ S. WATER - Private Well (King County E ironmental Services) AA (King CountyEnvironmental Services) 4. SANITARY SEWER (Lakehaven UtiliTy Di ct) ❑ Please Note: Erosion control measures must be in place during the demolition and through completion of the site clean-up. (Applicant) Bulletin #122 —March 16, 2017 Page 1 of I k:\Handouts\Demolition Permit Requirements DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8`h Avenue South CITY OF Federal Way, WA 98003-6325 Federal — 253-835-2607; Fax 253-835-2609 www.ci tyoffederalway.com DEMOLITION PERMIT CONTACT LIST This list of agencies may assist you in expediting the demolition permit process. Refer to the demolition permit requirements for signature blocks. All applicable signatures are required prior to permit approval. 1. Asbestos Removal: Puget Sound Clean Air Agency 110 Union Street, Suite 500 Seattle, WA 98101-2038 206-343-8800 –OR– 800-552-3565 www.pscleanair.org 2. Electricity: Puget Sound Energy Tacoma Public Utilities Attn: Construction Coordinator Customer Service 22828 68`h Avenue South, Suite #102 –OR– 747 Market Street Kent, WA 98032 Tacoma, WA 98402 888-225-5773 253-383-9600 or 253-383-2471 3. Gas: Puget Sound Energy 805 156`h Avenue NE Bellevue, WA 98004 888-225-5773 4. Telephone: Qwest Communications 801-962-2475 (phone) / 801-237-6491 (fax) 5. Water: Lakehaven Utility District Tacoma Public Utilities Technical Service Division Customer Service 31623 First Avenue South –OR– 747 Market Street Federal Way, WA 98003 Tacoma, WA 98402 253-941-2288 253-383-9600 or 253-383-2471 6. Garbage: Waste Management 655 Second NW Auburn, WA 98071 253-833-3333 (residential) – OR – 253-939-9792 (commercial) 7. Sewer: Lakehaven Utility District Technical Services Division 31623 First Avenue South Federal Way, WA 98003 253-941-2288 8. Septic: King County Environmental Services 14350 SE Eastgate Way Bellevue, WA 98007 206-296-4932 9. Fire Department: South King Fire & Rescue 33325 8`h Avenue South Federal Way, WA 98003 253-946-7248 Bulletin # 109 — January 1, 2011 Page 1 of I k:\Handouts\Demolition Permit Contact List pscleanair.org Puget Sound Clean Air Agency Single -Family Notification Case #: 201803760 This page must be printed. A printout of the notification, all amendments to the notification, and the asbestos survey shall be available for Inspection at all times at the asbestos project or demolition site (Reg III, 4.03(a)(6)). Fee Amount Paid $65.00 Credit Card Transaction # APOFF7A8374B Transaction Date 08/13/18 Owner's Name Yvette Estrada Phone (206) 556-1226 Project Street Address 3001- S 288th st Unit#360 City Federal way WA Zip 98003 Contact Person Yvette Phone (206) 556-1226 Mailing Address 3001-S 288th st unit#356 Federal Way, WA 98003 This project includes asbestos removal. Project Size 10 linear feet / 950 square feet Project Start Date 08/27/18 Completion Date 08/28/18 Asbestos will be removed by a licensed asbestos abatement contractor This project Includes a demolition. Demolition Start Date 08/28/18 Completion Date 08/31/18 Demolition will be completed by a demolition contractor I certify that: (1) This is a single-family residence project. The structure is used by one family who owns the property as their domicile. (2) The information I have provided is to the best of my knowledge accurate and complete. (3) 1 understand the fee for this Notification is nonrefundable. Create Another Notification If you have questions, contact us at asbestos@pscleanair.org or 206.689.4058. 12814 SE 318th Way Auburn, WA. 98092 HLPLUPL860JM SOLD TO: Camelot Square 3001 S 288th St Federal way WA 98003 SHIPPED TO: Unit 360 Sales Tax Rate: I 10.00% (253)677-0618 INVOICE NUMBER 10571 INVOICE DATE August 2, 2018 CUSTOMER PO # TERMS Due SALES REP Colby Wilson PREPAID or COLLECT COLL .. -. QUAAITlTY 0 ,' +lIT. PFE[CE Disconnect swer and water lines from home and cap. Parts and labor 1 250.00 250.00 SUBTOTAL TAX FREIGHT DIRECT ALL INQUIRIES TO: MAKE ALL CHECKS PAYABLE TO: PAY THIS Colby Wilson H&L Plumbing LLC AMOUNT (253) 677-0618 Attn: Michelle Wilson email: plumbingbyhl@yahoo.com 12814 SE 318th Way Auburn, WA. 98092 THANK YOU FOR YOUR BUSINESS! 50.00 25.00 DESCRIPTION/COMMENTS Letter of Alexander's Demolition Completion Abatement, LLC Ivette Estrada 3001-S288 th St unit#360 License # ALEXADL830K] Federal Way WA 98003 Asbestos Certification # 1638 Willmar Ramirez(Owner) From: 704145th St SW Lynnwood, WA, 98087 Phone: (425) 219-8624- Alexanderdemo98@gmail.com Date= 08/27/2018 TOTAL .SQ.FT. DESCRIPTION/COMMENTS SQ.Fr ALEXANDER'S DEMOLTTION ABATEMENT LLC. We remove asbestos in Roofing Area We using % Mask with Tyveks We using Manual and wet Methods The job was complete with air monitoring and Disposal in Burrito wrap no friable Material TOTAL .SQ.FT. 950 NAME SIGNATURE= WILMAR RAMIREZ CORNELIO Thank you for your business! OrC.R©NMENTAL S£RWCES, INSULTING & CONIPMANCE 34004 9- Avenue South Al2, Federal Way, Washington 98003 Telephone (253) 927-5233 Fax (253) 924-0323 August 3, 2018 PROJECT: Residential House 3001 S. 288th St. #360 Federal Way, WA 98003 NUMBER: N18-0308 CLIENT: Yvette Estrada 3001 So. 288"' St. #356 Federal Way, WA 98003 contents Section Introduction 1.0 Executive Summary 2.0 Regulatory Compliance 3.0 Sampling Plan and Laboratory Analysis 4.0 Survey Results 5.0 Conclusions and Recommendations 6.0 Limits of Survey 7.0 Appendices Laboratory Results A Certification(s) B SECTION 1.0 — INTRODUCTION: PROJECT DESCRIPTION: ASBESTOS Pre -Demolition Survey. Identify asbestos containing materials that could possibly be impacted during demolition at: 3001 So. 288' St. #360, Federal Way, WA 98003. Inspection was performed Friday, August 3, 2018, by Barry B. Brown, a certified AHERA building inspector, AHERA Accreditation No. Bi -NES -07-09-18-04, Expiration July 9, 2019. ** QUANTITIES ARE APPROXIMATE AND ARE NOT TO BE USED FOR BIDDING PURPOSES. PROSPECTIVE BIDDERS MUST SITE VERIFY QUANTITIES AND SITE CONDITIONS. SECTION 2.0 - EXECUTIVE SUMMARY: Building Description The residence is a one-story mobile home which is approximately includes: two bathrooms, two bedrooms, kitchen and living room. The consists of a rubber membrane, foam, two layers of silver -coat and tar. SECTION 3.0 — REGULATORY COMPLIANCE: Asbestos 938 square feet which house had a roof that The intent of the asbestos survey is to comply with governing asbestos regulations required by the State of Washington and Puget Sound Clean Air Agency (PSCAA). Currently, the State of Washington requires a written "good faith inspection" for identification of asbestos -containing materials prior to any remodeling or demolition work. During demolition and construction work it is the responsibility of the owner and the contractors to make this survey document available to all concerned parties who may be handling the building materials. In addition, PSCAA requires that a copy of the written asbestos survey be made available on- site for inspection by a PSCAA Control Officer during construction and demolition work. The survey is required to be performed in accordance with 40 CFR 763.86. These federal standards require inspections to be conducted by an EPA Accredited Building Inspector with analysis to be provided by an asbestos laboratory certified by the National Bureau of Standards. The requirements are described in Article 1 and Article 4, of PSCAA's Asbestos Control Standards. All survey work was conducted in compliance with the above-mentioned standards. Asbestos -containing materials are required to be removed and disposed of in accordance with Washington State Regulation 296-155 WAC, Part S prior to any demolition, renovation, or remodeling that would disturb these materials. Washington State Department of Labor and Industries and PSCAA require that the abatement be performed using Certified Asbestos Workers under the direct on-site supervision of a Certified Asbestos Supervisor in accordance with 296-65 WAC. Also see 296-62 WAC, Part I-1—General requirements for handling asbestos. SECTION 4.0 — SAMPLING PLAN AND LABORATORY ANALYSIS: Asbestos Objectives - The objective of the survey was to determine the quantity and location of building materials that contain asbestos within areas to be impacted by planned renovation work. Asbestos Sampling Plan Protocol This survey was conducted using a protocol adapted from the Asbestos Hazard Emergency Response Act (AHERA). The protocol is as follows: 1. Group materials into homogeneous sampling areas. ASBESTOS Pre -Demolition Survey Project #N18-0289 785 8t' St S, Kirkland, Washington 98003 Page 2 of 8 Now Environmental Services, Inc. July 31, 2018 2. Quantify each homogeneous sampling area and collect samples from each area using the "3-5-7" criteria for surfacing material to determine the number of samples needed. Quantify and collect a minimum of three samples of each thermal system insulation (the number of samples collected of miscellaneous materials was determined by the inspector). 3. Samples of each material were taken to the substrate, ensuring that all components of the material were included. 4. Sampling was performed by a Certified Building Inspector, and the use of proper protective equipment and procedures was followed. Asbestos Sampling Procedure 1. Spread the plastic drop cloth (if needed) and set up other equipment, e.g., ladder. 2. Put on protective equipment (respirator and protective clothing if needed). 3. Label sample container with its identification number and record number. Record sample location, and type of material sampled on a sampling data form. 4. Moisten area where sample is to be extracted (spray the immediate area with water). 5. Extract sample using a clean knife, drill capsule, or cork boring tool to cut out or scrape off approximately one tablespoon of the material. Penetrate all layers of material. 6. Place sample in a container and tightly seal it. 7. Wipe the exterior of the container with a wet wipe to remove any material that may have adhered to it during sampling. 8. Clean tools with wet wipes and wet mop or vacuum area with HEPA vacuum to clean all debris. 9. Seal the sampling location with caulking compound, spackle or duct tape. 10. Discard protective clothing, wet wipes and rags, cartridge filters, and drop cloth in a labeled plastic waste bag. Asbestos Laboratory Analysis The bulk samples were analyzed in our laboratory using polarized light microscopy (PLM) with dispersion staining in accordance with US EPA method 600/R-93/116 as specified in 40 CFR Chapter I (7-1-93 edition) Part 763, Subpart F, Appendix A, pages 499-504. Polarizing light microscopy quantifies asbestos concentrations at between 100% and 1% detection levels. Levels below 1% can only be stated as "trace." For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled L-1 for layer one and L-2 for layer two, etc.) and a total percentage for the entire sample. The asbestos concentration in the sample is determined by visual estimation. For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos. ASBESTOS Pre -Demolition Survey Project #N18-0289 785 Sffi St S, Kirkland, Washington 98003 Page 3 of 8 Now Environmental Services, Inc. July 31, 2018 SECTION 5.0 — SURVEY RESULTS: There ARE Asbestos Containing Building Materials identified during this survey. Table I LIST OF IDENTIFIED ASBESTOS CONTAINING BUILDING MATERIALS: Sample # Description Location Analysis Area 8-a Silvercoat — first layer Roof & roof edging 2% 950 sf Bathroom #1 Non Detect 02-b Chrysotile Bathroom #1 8-b Silvercoat — second Roof & roof edging 3% 950 sf 04-a layer Bathroom #1 Chrysotile 04-b 12-a Silvercoat — first layer Roof & roof edging 2% 950 sf Bathroom #2 Non Detect 05-b Chrysotile Bathroom #2 12-b Silvercoat — second Roof & roof edging 3% 950 sf 07 layer Roof Chrysotile 13-a Silvercoat — first layer Roof & roof edging 2% 950 sf Chrysotile 12-b Silvercoat — second Roof & roof edging 3% 950 sf layer Chrysotile TABLE II LIST OF SUSPECT BUILDING MATERIALS SAMPLED: Sample # Description Location` Analysis 01 Vinyl tile Front entryway Non Detect 02-a Joint Compound Bathroom #1 Non Detect 02-b Wallboard Bathroom #1 Non Detect 03 Ceiling material Living room Non Detect 04-a Vinyl sheeting Bathroom #1 Non Detect 04-b Mastic Bathroom #1 Non Detect 05-a Vinyl sheeting Bathroom #2 Non Detect 05-b Vinyl sheeting Bathroom #2 Non Detect 06 Skim coat Kitchen Non Detect 07 Roofing membrane Roof Non Detect ASBESTOS Pre -Demolition Survey Project #N18-0289 785 Sei St. S, Kirkland, Washington 98003 Page 4 of 8 Now Environmental Services, Inc. July 31,.2018 09 Exterior black sealant Edging around roof Non Detect 10 Exterior putty Windows Non Detect 11 Insulation Ceiling Non Detect NON DETECT = No Asbestos Containing Building Materials SECTION 6.0 - CONCLUSIONS AND RECOMMENDATIONS: There are ARE Asbestos Containing Building Materials which were identified during this survey. NOW Environmental Services is not responsible for materials which require destructive means to access, or materials which are hidden from sight, those materials hidden behind walls, or materials which cannot be found with reasonable diligence. Extreme caution should be used during renovation or demolition to ensure that additional unidentified materials are not disturbed. In the event that additional materials are discovered, the material should be sampled by an EPA Accredited AHERA Building Inspector and analyzed to determine if it contains asbestos prior to disturbance. Asbestos According to Washington Administrative Code (WAC) 296-62-07721, prior to the start of work, a building owner must identify the presence, location, and quantity of ACM and/or presumed ACM (PACM) prior to renovation and demolition. This information must be communicated to contractors bidding on work, contractors performing other work, employees and tenants in or adjacent to the work area. The Puget Sound Clean Air Agency Regulation III, Article 4 requires that an asbestos survey be conducted prior to any renovation or demolition of existing buildings. This survey was intended to meet these regulatory requirements. Asbestos -containing materials are required to be removed and disposed of in accordance with Washington State Regulations prior to any demolition, renovation, or remodeling that would disturb these materials. Washington State Department of Labor and Industries and PSCAA require that the abatement be performed using Certified Asbestos Workers under the direct on- site supervision of a Certified Asbestos Supervisor. The only exemption is for resident owners performing removal of asbestos -containing materials other than furnace interiors and direct applied mudded asbestos insulation. ACM is identified as those building materials containing greater than one percent (>1.0%) of asbestos as verified by laboratory analysis. All building materials fabricated prior to 1980 are assumed to contain asbestos unless proven otherwise by a licensed building inspector. Materials that contain 1.0% or less asbestos are not regulated for disposal purposes. However, removal of materials containing 1.0% or less asbestos is considered an unclassified asbestos operation by OSHA and WISHA. Unclassified asbestos operations cover employees likely to be exposed in excess of the permissible exposure limit (PEL), and who are performing operations not covered by Class I through IV. For construction work involving unclassified asbestos the applicable requirements will include: an exposure assessment, use of vacuum cleaners equipped ASBESTOS Pre -Demolition Survey Project #NIS -0289 785 r St. S, Kirk/and, Washington 98003 Page 5 of 8 Now Environmental Services, Inc. July 31, 2018 with HEPA filters, use of wet methods and prompt cleanup of debris, use of respirators and protective clothing, training, and record keeping. Asbestos -containing joint compound associated with non -asbestos gypsum wallboard (GWB) assemblies is sometimes found in specific locations of a building. The presence of asbestos in this material requires personnel impacting the material to adhere to regulatory requirement outlined in WAC 296-62-17712(2) and training as outlined in WAC 296-62-07722(5) and WAC 296-62-07728. Personal protect equipment and proper work practices are required pending completion of a negative exposure assessment. Such an assessment may include air monitoring of workers' breathing zones. Refer to WISHA Regional Directive 23.30 for additional information. The possibility exists that additional ACMs may be present in wall and ceiling cavities. Any previously unidentified material encountered during construction activities should be sampled prior to impact. Work that may be impact asbestos should be performed by personnel having proper training and utilizing proper worker protection according WISHA standards. NOW Environmental Services recommends that a Certified Asbestos Project Designer design any asbestos abatement project to ensure that the job is completed according to regulatory standards. SECTION 7.0 - LIMITS OF SURVEY: Asbestos surveys are non -comprehensive by nature and subject to many limitations including those presented below. Our assessment has considered risks pertaining to asbestos; however, this survey is limited to only those locations sampled. This survey was not designed to identify all potential concerns or eliminate all risk associated with asbestos. Materials sampled were limited by the scope of work as defined by the drawings provided. Lead based paint & TCLP testing, mercury light tubes and/or other hazardous materials were not included in the scope of work during the course of this survey. Other risks that were not evaluated with this survey; Risks such as 1) toxic and hazardous substances in (or in contact with or associated with) soil or ground water; 2) risks associated with structural, electrical, or mechanical working of the building; 3) risks associated with radon gas, slope stability, building settlement, moisture, or site drainage and flooding have not been evaluated during this survey. No warranty, expressed or implied, is made. The site visit consisted of a thorough visual walk-through of building for the purpose of viewing and sampling potential asbestos -containing material. A TCLP sample was not collected of the building to determine levels of leachable lead in building debris. Suspect PCB containing light ballasts were not estimated. Fluorescent bulbs were not quantified for recycling purposes. Mercury vapor lamps were not identified during the survey. NOW Environmental Services performed this survey in accordance with the generally accepted standards of care that exist in the industrial hygiene profession in Washington State at the time of this study. The asbestos survey was performed in preparation for removal of asbestos - containing materials in accordance with NESHAPS regulations. ASBESTOS Pre -Demolition Survey Project#Ni8-0289 785 a St. S, Kirkland, Washington 98003 Page 6 of 8 Now Environmental Services, Inc. July 31, 2018 INSPECTOR "g ENDORSEMENT �' :4 Bar . Brown AHERA Building Inspector PROJECT REVIEW: ANALYSIS METHOD: PARMETERS: Dennis Rauschenberg AHERA Building Inspector Polarized Light Microscopy EPA Method 600/R-98/166 ASBESTOS: Puget Sound Clean Air Agency (PSCAA) and Washington State Department of Labor and Industries (L&I) regulations require an inspection of all buildings for the presence of asbestos -containing materials (ACM) prior to renovation and demolition. ACM is identified as those building materials containing greater than one percent (>1.0%) of asbestos as verified by laboratory analysis. All building materials fabricated prior to 1980 are assumed to contain asbestos unless proven otherwise by a licensed building inspector. According to Washington Administrative Code (WAC) 296-62-07721, prior to the start of work, a building owner must identify the presence, location, and quantity of ACM and/or presumed ACM (PACM) in the work area. This information must be communicated to contractors bidding on work, contractors performing other work and tenants in or adjacent to the work area. The Puget Sound Clean Air Agency Regulation III, Article 4 requires that an asbestos survey be conducted by an AHERA Building Inspector prior to any renovation or demolition of existing buildings. This survey was intended to meet these regulatory requirements. DEFINITIONS: (1) Thermal System Insulation (TSI): These materials are defined as those applied to pipes, fillings, boilers, tanks, ducts or other structural components to prevent heat loss or gain. (2) Miscellaneous Materials: All other building materials that may be ACM but not surfacing materials or TSI fall into this category. (3) Surfacing Materials: These are defined as those materials that are sprayed -on, toweled -on or otherwise applied to surfaces including, but not limited to, lath and plaster, acoustical plaster on ceilings, paints, fireproofing materials on structural members or other materials on surfaces applied for decorative purposes. ASBESTOS Pre -Demolition Survey Project #N18-0289 785 Sffi St. S, Kirkland, Washington 98003 Page 7 of 8 Now Environmental Services, Inc. July 31, 2018 SAMPLES Thirteen samples were extracted from the building for the purposes of this EXTRACTED: inspection. Quantities are approximate and are not to be used for bidding purposes. Prospective bidders must verify quantities and site conditions. LIMITATIONS During demolition, it is possible that additional suspect ACM and / or hazardous AND materials may be discovered within wall, floor, ceiling sandwiches or other INACCESSIBLE areas/systems not accessible at the time of this survey. Should such suspect material AREAS: be discovered, a certified building inspector is required to sample and test the materials to provide evidence that they are non -hazardous containing materials NOW Environmental Services is neither responsible for the classification of materials that are not identifiable with reasonable diligence, nor for the identification of materials beyond the scope of this project as we understand it. No hard measurements were taken of this facility; all square/lineal footage figures are approximate rough estimates to provide perspective and scope. Site sketches are not to scale. Disclaimer This report and its contents are limited to the scope and activities performed at the subject property as described. We represent that our services were performed within the limits prescribed by applicable regulations and in a manner consistent with the level of care and skill ordinarily exercised by other professional consultants under similar circumstances. No other representation is made to the client, expressed or implied, and no warranty or guarantee is included or intended. ASBESTOS Pre -Demolition Survey Project #N18-0289 785 80 St, S, Kirkland, Washington 98003 Page 8 of 8 Now Environmental Services, Inc, July 31, 2018 ORION Environmental Services 34004 Ninth Avenue South, Suite Al2, Federal Way, WA 98003 Phone: (253) 952-6717 • Fax: (253) 927-4714 Email: info@oriones.net • Web: www.oriones.net WBE W21`9219763 Polarized Light Microscopy Test Report EPA Method 600/R-98/116 Client: Eva Estrada Address: 3001 S 288th St, Federal Way, WA 98003 Attention: Eva Estrada Project Name: 3001 S 288th St Project Number: N18-0308 Rpt. Date: 8/6/2018 Page: 1 of 2 Invoice: 184656 Date Rcvd: 8/6/2018 Client Sample ID Orion Sample ID Material Description Sample Treatment Asbestos Containing Material Asbestos Type Other Fibers 01 20180806-76 Self adhesive vinyl sheeting ND 02-a 20180806-77 Joint compound ND 02-b Wallboard ND cellulose 03 20180806-78 Ceiling material ND cellulose 04-a 20180806-79 Vinyl sheeting w/ no felt backing ND cellulose 04-b Mastic ND cellulose 05-a 20180806-80 Vinyl sheeting w/ felt backing ND man-made fibers 05-b Tan mastic ND man-made fibers 06 20180806-81 Skim coat ND 07 20180806-82 Roofing membrane ND 08-a 20180806-83 Silver coat 2 cellulose 08-b Silver coat 3 cellulose 09 20180806-84 Exterior black sealant ND 10 20180806-85 Exterior window caulking ND 11 20180806-86 Insulation ND fiberglass 12-a 20180806-87 Silver coat 2 cellulose 12-b Silver coat 2 cellulose 13-a 20180806-88 Silver coat 3 cellulose Polarized Light Microscopy Test Report (cont.) Client: Eva Estrada Address: 3001 S 288th St, Federal Way, WA 98003 Attention: Eva Estrada Project Name: 3001 S 288th St Project Number: N18-0308 Rpt. Date: 8/6/2018 Page: 2 of 2 Invoice: 184656 Date Rcvd: 8/6/2018 Dup: Laboratory QA/QC Duplicate; M; Mastic [(a), (b), (c), etc.]: Sample layers numbered from front to back. Comments: For layered samples, each component has been analyzed separately. ND means non -detect for asbestos fibers by EPA Method 600/R-98/116.Disclaimers: PLM has been known to miss asbestos in a small percentage of samples that contain asbestos. Thus, these laboratory results represent due diligence, however negative or <1 % PLM results can not be guaranteed. Per EPA guidelines samples will be archived for 30 days then will be disposed of. This report may only be reproduced in full with written approval of ORION Environmental Services. Analyzed By (Print) Dogp,kMcNeal Date 8/6/2018 Reviewed By (Print) Dennis Rauschenberg Date 8/6/2018 % Time e ' e 'nature) Client Orion Material Sample Asbestos Asbestos Other Containing Sample 1D Sample ID Description Treatment Material Type Fibers 13-b Silver coat 1 cellulose Dup: Laboratory QA/QC Duplicate; M; Mastic [(a), (b), (c), etc.]: Sample layers numbered from front to back. Comments: For layered samples, each component has been analyzed separately. ND means non -detect for asbestos fibers by EPA Method 600/R-98/116.Disclaimers: PLM has been known to miss asbestos in a small percentage of samples that contain asbestos. Thus, these laboratory results represent due diligence, however negative or <1 % PLM results can not be guaranteed. Per EPA guidelines samples will be archived for 30 days then will be disposed of. This report may only be reproduced in full with written approval of ORION Environmental Services. Analyzed By (Print) Dogp,kMcNeal Date 8/6/2018 Reviewed By (Print) Dennis Rauschenberg Date 8/6/2018 tA�ly;ze�B* atu Time e ' e 'nature) Time ATOWENJITRONAIENTAL SER VICES SAMPLE CUSTODY FORAf PROJECT NUAf13ER- At , O��6 !LIE NT NAME: LAB NO. SITE ADDRESS: RELIN UISIIEI) BY: P -Y •,1 MDRESS•.3C0j/ EACH LOCATION OF MATERIAL Q'I'Y. TREAT % pk �3 OTHER FIBERS o/ 'ELEPITONE: 57 - /91216 INSPECTQR2? BkW, RECEIVED BY: � DATE SAMPLED: 0-3--'19 DA`Z'E / TINIIP: - •-( 1 *00 Pf-j :T.LLULA.R: 4 HOUR 24-HOUR 3DAY AMPLI; NO. LAB NO. MA'I'LRIAL DESCRIPTION INIA'I'LRIAL I1) LAYER AND SUBSTRATE EACH LOCATION OF MATERIAL Q'I'Y. TREAT % TYI'1: OTHER FIBERS o/ �irh'L 1 ILEt`R'�'w�i �dJn1f �P�ti !) � MTH �� ��Iu�ly- ��f"i� 2u� � 15G � �, r �i fir► � �C1'� Sr V),Oy(. 0o� r=� �-�r c 1M og LA -Y eeS. ? 3 oc ioo, NOWENJIMONMENTALSER J17CES SAMPLE CUSTODY FORM PROJECTNUR BEI11�� � !LIE, NT NAME: SITI±. ADDRESS: MA'i'LRIALDESCRIPTION RELIN UISIIILD BY: .)DRESS: EACH LOCATION OF MATERIAL QTY. DATE, rrimL: % I'Y1'1(, OTHEIt FIBERS 'ELEPHONE: INSPECTOR -k. RECI+�IVI+�D I3Y: WX: DATL SAMPLED: DATE+' /'.rlrvlE: ;ELLULAR: 4 HOUR 24-11OUR 3DAY AMPLE NO. LAB NO. MA'i'LRIALDESCRIPTION AlA71'ERIAL I1) LAYER AND SUBSTRATE EACH LOCATION OF MATERIAL QTY. TREAT % I'Y1'1(, OTHEIt FIBERS ACDF-Ae-6,b, 16,2 v r, y °'u Lji,-j0LI) Fu t -i- 03F rr1 cr ori_ AHER. Sun7ey Building Features Site Address: 3001 t) �38"' �;T. EO L_ Residential P4Commercial [ ] Demolition Renovation [ ] Limited AHERA Survey[ ] Yes �M•No If Yes, Why: Approximate Construction Date: 1(.°c� 5 -fah Approximate Square Footage: yF Type of Construction: Type of Foundation: J3 L 06 Y_ �S Basement [ ] Crawl Space [ ] f Slab [ ] Major Renovation or Add -Ons: Number of Stories: L Interior Finishes: Vinyl Sheeting Vinyl Tile J] Wallboard �] Hardwood [ ] Plaster [ ] Exterior Finishes: Siding)j MfgAL Slip Sheeting [ ] Other: Lighting: Fluorescence [ ] Incandescent [ ] Heating: Forced Air [ ] Electric [ ] Wood Stove [ ] Boiler [ ] Other: Paneling Insulation]' Slip Sheeting [ ] Other: " Roofing: Three -Tab [ ] Roll Down [ ] Built -Up j Outer Buildings: Actual Time Spent at Survey Site: Hour (s) Minute (s) BUILDING INSPECTOR CERTIFICATE This is to certify that Barry B. Brown has attended and satisfactorily completed all requirements to maintain accreditation as an AHERA Building Inspector in accordance with the Toxic Substance Control Act Title (Section 206) and 40 CFR 763. Accreditation No. BI -NES -07-09-18-04 Course Date: July 09, 2018 Valid through: July 09, 2019 NOW Environmental Services, Inc. 34004 9t" Avenue South, Suite #12 Federal Way, Washington 98003 (253) 927-5233