Loading...
12-101817T T . f City of Federal Way duilding.-•Single F milt' � • �* ,,,,{{..�� i Community & Econ. Dev. ServMes - Permit #: 12-10181 i-00-s'lz 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Inspection Request Line: (253) 835-3050 Project Name: VENTANA LOT 26 Project Address: 30415 25TH AVE SW Parcel Number: 889420 0260 Project Description: NEW - Construction of new 3678 square foot 2 -story single family residence with a 136 square foot covered entry and a 768 square foot attached garage. Includes plumbing & mechanical. ***4 Bedrooms; estimated selling price $595,000*** Owner Applicant Contractor Lender CARY LANG CARY LANG CARY LANG CONSTRUCTION CARY LANG 29815 24TH AVE SW 29815 24TH AVE SW INC 29815 24TH AVE SW FEDERAL WAY WA FEDERAL WAY WA CARYLCIIOIOF (9/13/12) FEDERAL WAY WA New / Additional Sq. Feet - Garage.......................768 29815 24TH AVE SW Yes Number of Bedrooms............................................4 FEDERAL WAY WA 98023 1 Census Category: 101 - New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: 0 Floor Areas . ft. 0 0 0 0 Additional Permit Information New / Additional Sq. Feet - 1 st Floor....................1922 New / Additional Sq. Feet - 2nd Floor ................... 1756 New / Additional Sq. Feet - 3rd Floor....................0 Occupancy # 1 - Area (Sq. Feet) ............................. 0 New / Additional Sq. Feet - Basement...................0 Basic Plan? ........................................................... No Occupancy # 1 -Construction Type ........................Type V - B New / Additional Sq. Feet - Deck .......................... 0 New / Additional Sq. Feet - Garage.......................768 Mechanical to be Included? ................................... Yes Number of Bedrooms............................................4 Total Number of Dwelling Units. ........................... 1 Occupancy # 1 -Class .............................................R-3 New / Additional Sq. Feet - Other .......................... 136 Plumbing to be Included?.......................................Yes New / Additional Sq. Feet - Total.......................... 4582 Occupancy #I - Use ............................................... Residence (1 or 2 Zoning Designation ................................................ RS 9.6 family) Mechanical Fixtures Ducting ........................................... 1 Fans................................................ 4 Fireplace Inserts............................. 2 Furnaces ......................................... 1 Gas Piping ...................................... 1 Gas Pipe Outlets........................... 5 Hot Water Tanks ............................ 1 r Plumbing Fixtures Bathtubs ......................................... 2 Dishwashers................................... 1 Laundry Washer Outlets................ 1 Lavatories....................................... 5 Showers.......................................... 2 Sinks............................................... 2 Water Closets ................................. 3 Hose Bibbs..................................... 2 CONDITIONS: * A right of way permit is required for the curb cut & driveway approach installation. A ROW permit application, plans, permit fee, bid, insurance and bond is required. Contact ROW Permit desk at 253-835-2725 for more information. CO will not be granted if this process is not completed. f t t PERU EXPIRES Saturday, November*012 Permit Issued on Monday, May 7, 2012 ' 1 hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: /' `JDate: Z 2� City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: VENTANA LOT 26 Address: 30415 25TH AVE SW Permit #: 12 -101817 -00 -SF Includes: 41 42 43 44 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 1 0 0 0 0 Owner Name: CARY LANG CARY LANG Owner Name: Owner Address: 29815 24TH AVE SW FEDERAL WAY WA Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severly affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner / occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which itis situated. Such compliance is the responsibility of the owner and/or occupant of the premises. CITY OF Federal Way PERMIT #: Project: • THIS CARD ISTO AIN ON-SITE Construction In UE Record INSPECTION REQUE TS: (253) 835-3050 12 -101817 -00 -SF CARY LANG Address: 30415 25TH AVE SW FEDERAL WAY, WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. o SWM Precon Site Mtg (4400) E] Initial Erosion Control (4365) Footings/Setback (4110) Approved To be done prior to breaking ground Approved to place concrete / By Date 6, '�� 12 ByDate T, �lr By Date Rough Electrical Approved Final Electrical Approved Plumbing Groundwork (4190) E:] Drainage/Downspout (4040) By Foundation Wall (4115) By Approved to place concrete Approved to backfill Approved to cover By Date S / j -1-Z_ By A& A"ate 6 / By Date ❑ Floor Sheathing (4105) Slab/Concrete Floor (4255) Underfloor Framing (4285) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By Date 5-- By I- Date ❑ Roof Sheathing (4220) ❑ Rough Plumbing (4230) Shear Walls (4245) Approved to install siding Approved to install roofing/ Approved By ja�LDate - / ��� By &� Date �j�r/ �� By C Date - ls- U Mechanical Rough -in (4165) Gas Piping (4125) Fire/Draft Stops (4095) Approved Approved to release test Approved B� Date �- Z- ( By Date _ By �j Date 7 Framing (4120) Interim Erosion Control (4370) Prior to scheduling a Framing inspection; Approved Electrical, Plumbing & Mechanical Rough -in and Approved to insulate By r Date �C Fire/Draft Stop inspections must be signed -off and approved. IBC 109.3.4 By L Date 7 �, ❑ Gypsum Wallboard Nailing (4130) ❑ Final Erosion Control (4375) Insulation (4150) Approved to install wallboard Approved to install mud & tape Approved By- ,A� Date %- 7 By L �Date By Date Final - Plumbing (4075) Final - Building (4050) ❑ Final - Mechanical (4065) Approved Approved Approved By DateQ_ _ By Date W By Date q _ rl - Z_ Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date CITY OF Feder T PERMIT COMMUNITY DEVEL P,L �ES IV 253-835-2607• FAX 253-835-2609 PLICATION U�U'U,.at40 ,de-lu,ml.m R 2 4-2012 9 !z - 101&_1 7 - MF CO ME PL DE EN FP �5/zZ jZ co AL VVA SITE ADDRESQ'\/�ME SUITE/UNIT # Ar ✓ `-� r V PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL # Y_ 9-0 - aoZCQ 0 TYPE OF PERMIT Q BUILDING 10 PLUMBING O MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT (Tenant Name/Homeowner Last Name) V "T?Nr \ L� PROJECT DESCRIPTION Detailed description of work to be included on this permit only PROPERTY OWNER NAME / �-- t. ` : i` 'n"'V (;- PRIMARY PHONE > J MAILING ADDRESS E-MAIL CITY"devltt I T fCC STAT_ ZIP I NAME PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # NAME ,,,/�� Q PHONE APPLICANT MAILING ADDRESS E-MAIL CITY STATE ZIP FAX PROJECT CONTACT NAME PHONE (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence concerning this application) CITY STATE ZIP FAX ALTERNATE CONTACT NAME: PHONE E-MAIL PROJECT FINANCING NAME OWNER -FINANCED Required value of $5,000 or more MAILING ADDRESS, CITY, STATE, ZIP PHONE (RCW 1 9.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city a part of this application. _ t SIGNATURE: z �`� DATE PRINT NAME: Bulletin #100 — January I, 2011 Page 1 of 3 k:\Handouts\Permit Application Adilk MECHANK'At. FIXTURES VALUE OF MECRAWCAL WORT[ $ f (a copy of bid or estimate must be provided) Indicate how many of each type off re to be installed or relocated of this project. Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS )commercial) BOILERS �_ FURNACES Z HOT WATER TANKS (Gas) COMPRESSORS _ GAS LOG SETS REFRIGERATION SYST DUCTING �. GAS PIPING WOODSTOVES PLUM! LNG F[YTL RE5 icate how many of each type off re to be installed or relocated as W of this project. Do not include existing fixtures to remain. BATHTUBS (or Tub/shower combo) LAVS (Handsinka) TOILETS WATER PIPING _L DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kitchen/utility) WATER HEATERS (Electric) / % _ 2 HOSE BIBBS SUMPS —!— WASHING MACHINES t TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? N u WATER PURVEYOR Let kc k r SEWER PURVEYOR 4 k -f VALUE OF EXISTING IMPROVEMENTS $ VA C4A (- EXISTING/PREVIOUS USE EXISTING/ PREVIOUS 1. t --i— V ACA LOT SIZE (In Squue Feet) mit Q C EXISTING FIRE SPRIN�'"ER SYSTEM? ❑ Yes 6a' No PROPOSED FIRE SUPPRESSI N SYSTEM? ❑ Yes 7o RFSIDENTIAI, - NFw OR AMMOP' AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE .............. BASEMENT FIRST FLOOR (or Mobile Home) 1-07 ADDITION SECOND FLOOR i COMMERCIAL - REIIODFI. - ,'v "T I-NIl'RO`'EME`TS Area AREA DESCRIPTION in Square Feet COVERED ENTRY. Construction Typa # of Stories Additional Information TOTAL BUILDING DECKS z TENANT AREA ONLY -- GARAGE' CARPORT ❑ PROJECT A ONLY OTHER (describe) Area Totals EXISTING PROPOSED ' /, TOTAL "NEW HOMES OATLY** ESTIMATED SELLING PRICE $ "7 l ' ' / C # OF BEDROOMS4t COMMERCIAL — NEWADINTIOv AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction Type # of Stories Additional Information NEW BUILDING ADDITION i COMMERCIAL - REIIODFI. - ,'v "T I-NIl'RO`'EME`TS Area AREA DESCRIPTION in Square Feet Occupancy Group(s) Construction Typa # of Stories Additional Information TOTAL BUILDING TENANT AREA ONLY -- PROJECT A ONLY Bulletin #100— January 1, 2011 Page 2 of 3 k:\Handouts\Permit Application r .t . AOSff W ORAWAGEAWAYFROM STRUCTURES n t Tca fABIOCYIAt[Gi4l uGQJ11NIKM1s11d15 MMTBEEPIALIX'EUBFNHF�N j WIRE ' LESS T±iAN 10'FROM TF/E PROPERTY L/RE �oLFsoawaFlwcstoATrrtmtawac -'f�qF ounRRv vacs + �\MEMEOsu�IrorsTFEHCE }B� FOa FRTFRFABAC o.nM..e� GF `s .R. w.w p a a �6•:Iz _ e 2.^, ¢ A �: �' Buonna ` f v TRFrvcH i' 1 1 .. caouwtsua.c- J� �I 1 I. - %� /�//\!/\��/\�/���\�� ` R,ssuIM cam' tt :Adelaide 11 1 o ADELADr `� rawL nsma __ _- -_ __ C_- ..Tr aRaoFrm-� ✓'r f,-SW5o4:IStE if —�; "j 6MN. 16MAV. FOA MNEHML IROVIDE -' O'TOC WAaRY5VALL5 IC�ti� � 1 I. I � '. V /f :i 6iniulSA$", , (0R:1 t It TrT w000 Po9f5. T4v06B 1, iOCF-0RRESYEMIPL may} r rfAOO[ I ORaFilFA9aFUP/4FM SIAGIEFMtlLYLDTS) �I GRI:SS I:GaLEBSMFAWIDTH F 2 ^3N9 ,i$NiN.ib1L11 $' // —Apf.KL SIY<A16MFiY L1-1.T x. .• W GRAM W pi lRflffR TO WE AID .. --' 2 ? - / „-SW�BBtfl ;!' .SW3GBnS SN�BBI 1 y RWMW O, W 101 hFUN w v WRELiESM PGORTF 15 N '1 2 (IOB LOCnTEDC�uTRE CONSTRUCTION ENTRANCE- .. .00WM "ODEOFI E ' T L� 11 h 1 'FILTER F.VRIC) POS I T I V DRAINAGE MTU �R� NTs r a i ' 4VA6HFDGR4VEl6ACllFM11- 1 -.a �3f !% - _ .' 1 1•. •' � IVTS • - ON P/JiHSNES OFFILTER FERGE. F,UPo` r DRIVEWAY DRAINAGE TO 5E ROUTED - n+aaa�esz 5OOm TO ROADWAY. DRAINAGE SYSTEM. sw3127&6tz64aoamt roBP�®iwzNnvre9aue:Rna,�e o ' h -SILT. FENCING =STOCKPILED SOIL _ !I wsxlrTRea;,n,wo a �\,\ ///�/� ! `• • LEAVE n11N.YE%POSED =.. ,.. 1 1 VICINITY MAP SILT FENCE DETAIL NTs :I NTS - 22 5 ELEV. m 41.12 LEV.ID' VENTANA / `LOt'o .T 2 i r -1 qr — -�_=� �_------- _ -- 1 25' i +�---I 30415 25TH AVE. SW r!COVERAGE. CALC; w— w r m -- g _— i w.l. EXCAVATIGN 0 { LOT AREA= 9,815 SF t GRADING n PORCH PROPOSED STRUGTURE(footprint)= 2151 SF W El! COVERED I COVERED PORCHES ;euD % .(L 0 to LIMITS 1 OP SED `I DRIVEWAY/WALKWAY 8 SF c O p'7 4 U: RESID N U1 LOT COVERAGE= 36i3 /9S15 r �' MAIN FP EL _ (4 365io n: gin' j o u 104 4 I RESUBMITTED z L i { N DRIVE CONC.,:1 a< Z COS N APR 2 5 2012 m N N z A CTTY OF FEDERAL WAY SCALE :1:; y . Z DN W 5' S85L - O D o co e � � 25' CARY LANCCUSTOM'NO"ES �` 07; 14 T — ELEV. 10' PLAN LS2-3/o18 E EV. 0, TIGHTLINE STOI;I"1 64'--t' DRAINAGE TO EXISTING