18-100706Building - Single Family
ciryorFederalway Permit #:18-100?06-00-SF
Community Development Dept.
33325 8th Ave S
Federal Way, WA 98003 Inspection Request Line: (253) 835-3050
M: (253) 835-2W7 Fax (253) 835-2609
Project Name: SPECIALIZED HOME CARE
Project Address: 1824 S 344TH ST Parcel Number: 412960 0040
Project Description: ALT - Verification of Occupancy for Adult Family Home. ***No construction work allowed
under this permit.***
Owner
Applicant
Contractor
Lender
PAUL MUNGAI
PAUL MUNGAI
1824 S 344TH ST
1824 S 344TH ST
FEDERAL WAY WA 98003
FEDERAL WAY WA 98003
USA
USA
Census Category: 434 - Residential alt/add - no change in number of units
Includes: #1 #2 #3 #4
Occupancy Class:
Construction Type:
Occupancy Load:
Floor Area (sq. ft.)
Additional Permit Information
Mechanical to be Included? ..................................... No Is this an Online or O.T.C. application?.................. Yes
Plumbing to be Included? ........................................ No Will Certificate of Occupancy be Issued?............... No
PERMIT EXPIRES Sunday, 12 August, 2018
Permit Issued on Tuesday, February 13, 2018
hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way. tt
Owner or agent: 0 (� Date: �� f
• • 1 L f
e �
f f
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance, this structure w in
compliance with the various ordinances of the City regulating building construction or use. This rtificate is valid
ONLY when endorsed by City staff.
Tenant Name: SPECIALIZED HOME CARE/ Permit # 18 -100706 -00 -SF
Address: 1824 S 344TH ST
Includes: #1 #2 #3 #4
Occupancy Class:
Construction Type:
Occupancy Load:
Floor Area (sq. ft.)
Owner Name: P L MUNGAI
Owner Address 1824 S 344TH ST
FEDERAL WAY WA 98003
USA
B ' ing Official Date
The priority in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience s shown most severely affect the health and safety of the general public. Although the City has made as complete
a re vie nd inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees
nor wants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
finance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
` which itis situated. Such compliance is the responsibility of the owner and / or occupant of the premises. 0
41k
CITY OF
Federal Way
PERMIT NUMBER I
PERMIT APPLICATION
PERMIT CENTER + 33325 8th Avenue South + J='a 03-6325
253-835-2607 + FAX 253-835-2609 + pe. e. f fZway.com
10 0,7_0 6 SF
FEB 1 11 2018
TARGET DATE CIN r)F FEDERAi WAY
rY)Mrut 1Nr Y DEVELOPMENT
SITE ADDRESS
SUITE/UNIT #
$ PROJECT VALUATION
ZONING
ASSESSORS/PARC o a - Q O ^
TYPE OF PERMIT
BUILDING \aPLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
PROJECT DESCRIPTION
Detailed description of work to
1.�� �L37 c- L'ij
be included on this permit only
NAMF,
PRIMARYPHONE
PROPERTY OWNER"LINd
ADDRESS
CIT
STATpE
ZIP
_
\
NAME �-
PHONE
MAILING ADDRESS
E-MAIL
CONTRACTOR
CITY
STATE
ZIP
FAX
WA STATE CONTRACTOR'S LICENSE #
EXPIRATION DATE
FEDERAL WAY BUSINESS LICENSE #
NAM j
PRIMARY PHONE
APPLICANT-
MAILING ADDRESS -J c_.
k �
E-MAIL
CITY qq pp
STATE
ZIP
FAX
'
PROJECT CONTACT
NAME � %'�
PRIMARY PHONE
MAILING ADDRESS
E-MAIL
l'The individual to receive and
respond to all correspondence
concerning this application)
CI'T'Y
STATE
ZIP
FAX
PROJECT FINANCING
NAME
❑ OWNER -FINANCED
When value is $5,000 or more
(RCW 19.27.095)
MAILING ADDRESS, CITY, STATE, ZIP
PHONE
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to�the as a part of this application.
�city
SIGNATURE: 11� �C"I ��— DATED ! �'
PRINT NAME: ( v� kJ yviu,1' A -'-�t—
Bulletin #100 —January 29, 2016 Page 1 of 2 k:\i-iandouts\Permit Application
L '<Z't"I
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST
Code References: 2015 IRC Section R325 (WAC 51-51) �9 tCC) __7O�
APPLICATION NUMBER:
SECTIONS 1. 2. 3. AND 4 MUSTBE COMPLETED By APPLICANTBEFORE INSPECTION WILL BE PROCESSED
SITEADDRESS: /.
PROPERTY OWNER NAME:
SECTION 1— PROPERTY INFORMATION
ASSFSS�
TAX/PARCEL#:_______-_
P _
DAYTIME PHONE:,
AFH LICENSEE NAME (IFDIFFERENT):�^DAYTIME PHONE
On a separate sheet of paper (8 1/2x 11) draw a floor plan (including all
floors) of your prospective AFH. Include all sleeping rooms (bedrooms)
indicating which bedroom is: A, B, C D, E and F.
Label all components for exiting i.e., stairs, ramps, platforms, lifts and
elevators.
I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and that I am
requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home
at this location. I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs,
expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any person, including the undersigned,
and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and
employees, upo — 'accuracy of the information supplied to the jurisdiction as a part of this application. I ,
NAME/TITLE: ,z ?2L��Cj DATE: I I !
}PROPERTY OWNER
(Effective July 1, 2013.)
APPLICANT Q LICENSEE
Effective: 2013 July 01
Updated: 2017 February
l
WAC 51-51-0325
Section R325 — Adult family homes.
SECTION R325
ADULT FAMILY HOMES
R325.1 General. This section shall apply to all newly constructed adult fainly homes and all existing single family homes being
converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington
department of social and health services prior to July 1, 2001.
R325.2 Reserved.
8325.3 Sleeping room classification. Each sleeping room in an adult family home shall be classified as:
1. Type S - Where the means of egress contains stairs, elevators or platform lifts.
2. Type NS1 - Where one means of egress is at grade level or a ramp constructed in accordance w ith R325.9 is provided.
3. Type NS2 - Where tw o means of egress are at grade level or ramps constructed in accordance w ith R325.9 are provided.
8325.4 Types of locking devices and door activation. All bedroom and bath ro doors shall be openable from the outside when
locked.
Every closet shall be readily openable from the inside.
Operable parts of door handles, pulls, latches, locks and other devices i tailed in adult family homes shall be operable w ith one
hand and shall not require tight grasping, pinching or tw isting of the w r' t. Pbcket doors shall have graspable hardware available
when in the closed or open position.
The force required to activate operable parts shall be 5.0 pound (22.2 N) maximum Required exit doors shall have no additional
locking devices.
Required exit door hardw are shall unlock inside and outside mechanisms w hen exiting the building allow ing reentry into the ad ult
family home w lthout the use of a key, tool or special know ledge.
8325.5 Smoke and carbon monoxide alarm requirements. All adult family homes shall be equipped w ith smoke and carbon
monoxide alarms installed as required in Sections R314 and 8315.1. Alarms shall be installed in such manner so that the
detection device warning is audible from all areas of th dw elling upon activation of a single alarm
8325.6 Escape windows and doors. Every sleepin room shall be provided w ith emergency escape and rescue w indow s as
required by Section R310. No alternatives to the sill freight such as steps, raised platforms or other devices placed by the openings
w ill be approved as meeting this requirement.
R325.7 Fire apparatus access roads and w ate r s u pply for fire protect ion.Adult family homes shall be served by fire apparatus
access roads and water supplies meeting the requirements of the local jurisdiction.
R325.8 Grab bar general requirement ere facilities are designated for use by adult family home clients, grab bars forwater
closets, bathtubs and shower stalls sha a installed according to this section.
8325.8.1 Grab bar cross section. rab bars w ith a circular cross section shall have an outside diameter of 1 1/4 inches minimum
and 2 inches maximum. Grab bars ith noncircular cross section shall have a cross section dimension of 2 inches maximum and a
perimeter dimension of 4 inches nimum and 4 5/8 inches maximum
R325.8.2 Grab bar installation. Grab bars shall have a spacing of 1 1/2 inches betw een the w all and the bar. Projecting objects,
control valves and bathtub or show er stall enclosure features above, below and at the ends of the grab bar shall have a clear space
of 1 1/2 inches to the grab bar.
EXCEPTION: Swing -up grab bars shall not be required to meet the 11/2 inch spacing requirement
Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener, mounting device or
supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering
unit. Acrylic bars found ip bathing units shall be removed.
Fixed position grab barA, when mounted, shall not rotate, spin or move and have a graspable surface finish
R325.8.3 Grab ba s at water closets. Water closets shall have grab bars mounted on both sides. Grab bars can be a combination
of fixed positiond sw ing-up bars. Grab bars shall meet the requirements of R325.8. Grab bars shall mount between 33 inches
and 36 inches a ove floor grade. Centerline distance between grab bars, regardless of type used, shall be between 25 inches
Effective: 2013 July 01
Updated: 2017 February
minimum and 30 inches maximum.
R325.8.3.1 Fixed position grab bars. Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from
the rear wall.
R325.8.3.2 Swing -up grab bars. Sw ing-up grab bars shall be a minimum of 28 inches in length from the rear w all.
R325.8.4 Grab bars at bathtubs. Horizontal and vertical grab bars shall meet the requirements of R325.8.
R325.8.4.1 Vertical grab bars. Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and
head end w all. Grab bars shall mount w ithin 4 inches of the exterior of the bath tub edge or within 4 inches w ithin the bath tub. The
bottom end of the bar shall start between 36 inches and 42 inches above floor grade.
EXCEPTION: The required vertical grab bar can be substituted with a floorto ceiling grab bar meeting the
requirements of R325.8 at the control end and head end entry points.
R325.8.4.2 Horizontal grab bars. Horizontal grab bars shall be provided at the control end, head en , and the back w all within the
bathtub area. Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Co of end and head end grab bars
shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length.
8325.8.5 Grab bars at shower stalls. Where shower stalls are provided Xheeq require nts for bathing facilities, grab bars
shall meet the requirements of 8325.8.
EXCEPTION: Shower stalls with permanent built-in seats are ir d to have vertical or horizontal grab
bars at the seat end wall.Averticalfloortoceiliarshallbeinstalledwithin4inchesof
the exterior of the shower aligned with the noseilt-in seat.
R325.8.5.1 Vertical grab bars. Vertical grab bars shall be 18 inches minimgth and installed at the control end wall and
head end wall. Vertical bars shall be mounted within 4 inches of the exteriow er stall or within 4 inches inside the show er
stall. The bottom end of vertical bars mount between 36 inches and 42 inc floor grade.
R325.8.5.2 Horizontal grab bars. Horizontal grab bars shall be instalk on all sides of the show er stall mounted betw een 33
inches and 36 inches above the floor grade. Horizontal grab bars shOfl be a maximum of 6 inches from adjacent w alls. Horizontal
grab bars shall not interfere w ith show er control valves. /
8325.9 Ram ps. All interior and exterior ramps, when provided,411.8.1
all be constructed in accordance w ith Section 8311.8 with a
maximum slope of 1 vertical to 12 horizontal. The exception to:, is not allowed for adult family homes. Handrails shall be
installed in accordance w ith 8325.9.1.
R325.9.1 Handrails for ramps. Handrails shall be installe on both sides of ramps between the slope of 1 vertical to 12 horizontal
and 1 vertical and 20 horizontal in accordance w ith R311. .3.1 through 8311.8.3.3.
R325.10 Stair treads and risers. Stair treads and riser shall be constructed in accordance w ith 8311.7.5. Handrails shall be
installed in accordance w ith 8325.10.1.
R325.10.1 Handrails for treads and risers. Handr shall be installed on both sides of treads and risers numbering from one riser
to multiple risers. Handrails shall be installed in acc rdance w ith R311.7.8.1 through R311.7.8.4
R325.11 Shower stalls. Where provided to meet he requirements for bathing facilities, the minimum size of show erstalls for an
adult family home shall be 30 inches deep by 48 nches long.
(Statutory Authority: RCW 19.27.031 and chapters 27 and 34.05 RCW. 13-04-068, § 51-51-0325, filed 2/1/13, effective 7/1/13. Statutory
Authority: Chapter 19.27 RCW. 10-18-0316 § 51-5 -0325, filed 8/25/10, effective 9/25/10. StatutoryAuthority: RCW 19.27.190, 19.27.020, and
chapters 19.27 and 34.05 RCW. 09-04-023, § 51 1-0325, filed 1/27/09, effective7/1 /10. StatutoryAuthority: RCW 19.27.074, 19.27.020, and
chapters 19.27 and 34.05RCW 07-01-090, § 5A-51-0325, filed 12/19/06, effective 7/1/07. StatutoryAuthority: RCW 19.27.031 and 19.27.074.04-
01-109, § 51-51-0325, filed 12/17/03, effectiv /1/04.]
Effective: 2013 July 01
Updated: 2017 February
NAME OF AFH:
SECTIONS MUSTBE COMPLETED BYTHE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED.
PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN —USING THEIR PROSPECTIVE RESIDENT
BEDROOM DESIGNATIONS OF A B CD E AND F AND CLASSIFICATION CODE S, NS1 OR NS2.
SECTION 5 — BUILDING INSPECTOR'S INSPECTION CHECKLIST
R325.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as:
Type S —where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area.
Type NSI — where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R325.9 is provided to evacuate residents to public area.
Type NS2 — where 2 means of egress at grade level (both have no stairs) or ramps constructed compliant with 5.9 are provided to evacuate residents to public area.
SLEEPING ROOM A Type S jErType NS1 10 Type NS2
YES NO -
Closet door/sare readily openable from the inside JDYes 1[3 No Smokealarm is installed in the bedroom
D
Bedroom door opens easily and quickly from the outside when locked
12 0
SI eepi ng room window has a net opening of 5.7 SF (minimum dimensions at I east 24"high; at least 20" wi de)
EXCEPT per R310.2.1: at -grade es cape wi ndows —may have net clearance opening 5 SF
D
Sleeping room window has a maximum sill heightof 44" abovefloor to clear openingLDosteps under window allawe
0
SLEEPING ROOMS,:,, Type S jUlype NS1 10 Type NS2
YES NO
Closetdoor/s are readily openable from the inside DYes 1[3 No I Smoke alarm is installed inthebedroom
W 0
Bedroom door opens easily and quickly from the outside when locked
19 0
Sl eepi ng room window has a net opening of 5.7 SF (minimum dimensions at I east 24"high; at least 2(Ywi de)
EXCEPT per R310.2.1: at -grade escape wi ndows —may have net clearance opening S SF
D
Slee ingroomwindowhasamaximumsillhei ht of 44" abovefl oor to clear oenin steps under window allowec
0
SLEEPING Type S JERtype NS1 JE3 Type NS2
YES. NO
Closetdoor/s are readily openablefromthe inside_ 113 Yes 1[3 No Smoke alarm is installed in the bedroom
ff 0
Bedroom door opens easily and quicklyfrom the outside when locked
12' 0
SI eepi ng room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wi de)
EXCEPT per R310.2.1: at -grade escapewindows—may have net clearance opening SF
D
SI eepi ng room window has a maximum sill height of 44" a bove fl oor to clear opening; no steps under window allowec
E3
SLEEPING ROOM 0 10 Type S 1 E3 Type NSi 10 Type NS2
YES NO
Closetdoor/s are readily openable from the inside JOYes INo I Smoke alarm is installed in the bedroom
0 0
Bedroom door opens easily and quickly from the outside when locked
0 0
Sl eepi ng room window has a net opening of 5.7SF (minimum dimensions at least 24"high; at I east 20"wi de)
EXCEPT per R310.2.1: at -grade escape windows—may have net clearance opening 5 SF
0 0
SI eepi ng room window has a maximum sill height of 44" above floor to clear opening; no steps under window a Ilowe
SLEEPING .ROOM EjUTypeS 10 Type NS1 JU Type NS2
YES NO
Closetdoor/s are readily open able from the inside DYes 10No I Smokealarm is installed in thebedroom
0 0
Bedroom door opens easily and quickly from the outside when locked
0 1 0
SI eepi ng room window has a net opening of 5.7SF (minimum dimensions at I east 24"high; at I east 20"wide)
EXCEPT per R310.2.1: at -grade escape wi ndows —may have net clearance opening 5 SF
0 0
Sleeping room window has a maximum sill heightof44" abovefloor to clear opening; no steps under window allowe
SLEEPING ROIrSM'FE3 Type S 113 Type NS1 113 Type NS2
YES NO
Closetdoor/s are readily openablefromthe inside 13 Yes --M No I Smokealarm is installed in the bedroom
Bedroom door opens easily and quickly from the outside when locked
0 0
Sleeping room window has a netopening of 5.7SF (minimum dimensions at least 24"high; atleast 20"wide)
EXCEPTper R310.2.1: at -grade escape windows—may have net clearance opening SF
0 0
SI eepi ng room wi ndow has a maximum s ill height of 44" a bove fl oor to clear opening; no steps under window a I lowe
0
Effective: 2013 July 01
Updated: 2017 February
GENERAL
Bathroom doors are easily and quickly openablefrom the outsidewhen locked
Carbon Monoxide alarms are installed as required in R315 on each I evel of the home.
YES
&F
, NO
0
13
Smoke alarms arei nstalleclon all levels of the dwelling, i neachresidentsleeping room, outsideeach separate
4M
Q
sleeping area in the i mmed late vi cinity of sleeping rooms (7314).
NO
R31175taitway8 N/_
7311.7.5.1 Riser Height: Max riser height shall be 7 % inches (8 inches in structures builtpriorto July 1, 2004)
Smoke and Carbon Monoxide alarms are installed insuch a manner sothatthe audiblewarning may beheard in all
10
13
parts of the dwelling upon activation of a single device.
Q
risers. Handrails shall be installed in accordance with R311.7.8.1—R311.7.8.4
Access road and water supply meet I ocal fi re j urisdictional requirements.
R325.4 Operable parts ofdoor handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand
13
and shall not require tight grasping, pinching or twisting ofthe wrist (lever -type).
!J
Pocket doors shall have graspable ha rdwa re ava ilable when in the closed or open position.
Guard
36" min
Handrail both sides
Less than 4" F 34" - 38"
3'x3'min
landing
3'x3'min
landing
One unit vertical in twelve units horizontal 3'
minimum is an 8.3% slope all along surface of the ramp. minimum
8311:3 Means of Egress YES
R311.2 Door must be side -hinged with min. width of 32 inches between face of door and stop. Height not less than 78 inches.
NO
13
7325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand
13
and shall not require tight grasping, pinching or twisting of the wrist (lever -type).
R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry
Q
without use of key, tool or special knowledge.
YES
NO
R31175taitway8 N/_
7311.7.5.1 Riser Height: Max riser height shall be 7 % inches (8 inches in structures builtpriorto July 1, 2004)
R311.7.5.2 Tread Depth: Min. tread depth shall be in 10 inches (9 inches in structures builtpriorto July 1, 2004)
treads and risers numbering from one riser to multiple
7325.10.1 Handrails for Treads and Risers shall be installed on both sides of 13
Q
risers. Handrails shall be installed in accordance with R311.7.8.1—R311.7.8.4
Effective: 2013 July 01
Updated: 2017 February
N �,J �QrL/ �? • Sd��� Ca
Effective: 2013 July 01
Updated: 2017 February