07-106074AF City of Federal Way Community Development Services P.O. Box 9718 Federal Way, WA 98063-9718 Ph: (253) 835-2607 Fax: (253) 835-2609 1 r Electrical Permit #: 07 -106074 -00 -F -L Project Name: THE MUTUAL FUND Project Address: 32225 PACIFIC HWY S Suite 103 Project Description: Relocate T -stat. Inspection Request Line: (253) 835-3050 Parcel Number: 150050 0100 Owner Applicant Contractor HARSCH INVESTMENT PROPERT AMBIENT CONTROL CO INC (ELECTRICAL) AMBIENT CONTROL CO INC 5113 PACIFIC HWY S SUITE 1E 1411 R ST (ELECTRICAL) FIFE WA 98424 AUBURN WA 98001 AMBIECCO03CJ (3/1/08) 1411 R ST AUBURN WA 98001 Additional Permit Information Service greater than 1000 Amps?...........................No Electrical Fixtures Thermostat .. ......................... 'I Pr=RtM " EXPIRES Tlwrsday, October 30, 2008 PJVrmif JSSued on Monday, November 5, 2007 I hereby certify that #w above Information is correct and that ft construction on t1% above described property and the occupancy and the use will`be in acc6fdance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: I I /,-S- a THIS CARD IS TO REMAIN ON-SITE CITY OF Community Development Inspection Record. Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMIT #: 07 -106074 -00 -EL Owner: HARSCH INVESTMENT PROPERT Address: 32225 PACIFIC HWY S Suite 103 FEDERAL WAY, WA 98003-6000 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the .inspections or the inspection sequence Ongoing inspections are logged on the back of this card. ❑ Rough Electrical (4225) ❑ Ceiling Cover (4020) ❑ Final - Electrical (4055) Approved Approved Approved B Date l �t%7 By Date y Date/ -- �] UFER Ground (4295) Approved By Date For inspector reference only ❑ Rough Electrical ❑ FINAL - Electrical Approved Approved By Date By Date ❑ Slab/Concrete Floor (4255) ❑ Ditch cover (4030) ❑ Pool Bonding (4195) Approved to place concrete Approved Approved By Date By Date By Date - ❑ ❑ Service (4235) Feeders/Sub-panels (4045) ❑ Temporary Power (4275) Approved Approved Approved By Date By Date By Date ❑ Rough Electrical (4225) ❑ Ceiling Cover (4020) ❑ Final - Electrical (4055) Approved Approved Approved B Date l �t%7 By Date y Date/ -- �] UFER Ground (4295) Approved By Date For inspector reference only ❑ Rough Electrical ❑ FINAL - Electrical Approved Approved By Date By Date avy _ 1 ? Fe&M1 � EIVED L — '` tww PERMIT SF MF CO ME g)PL DE EN PP • ODJpN11W1'DEPELOPA/BNT3ERYlC&4 ?1;.MA► ,WA98ro7,,,, APPLICATION PBDERAL WAY, X 91061--2 i O\ 1 O. 2 ?59•d9S?607• PAX?S?-d95�?601 Y 2U following ��a F ERAL WAYan incomplete mP' application will not be accepted please print,kgibly (in" or type. PROPERTY• • SITE ADDRESS .� %% 14k)1-1 S A7-- lei l IVa.) 9�c'c3 sUITZIUM #� . AS8E8SOYt'S TAR/PARCEL# I S v O - _�C� — LOT SIZE (sj) LEGAL DESCRIPTION (e.g. Acme Estates, Lot 1) (�►�•�•rro•a � we•I d�i�V PROJECT• • TYPE OF PERMIT O BUILDING O PLUMBING . o MECMMCAL O DEMOLITION ELECTRICAL O ENGINEERING ❑ FIRE PREVENTION SYSTEM PROJECT DESCRIPTION (Provide detailed descrjtion of work included on this Permit onlul PROJECT. NAME (Name of siness or Oumer Last Namel PROPERTY OWNER CONTRACTOR APPLICANT PROJECT CONTACT LENDER N PEOPLE INFORMATION NAME APPLICANT NAME &1-1r Ls PRIMARY PHONE MAILING ADDRESS MAILING ADDRESS /V .LJ CnY, STAT , ZIP EMAIL ADDRESS COMPANY NAME I 4 CD-�-' 1 APPLICANT NAME &1-1r Ls OFFICEPHONE (z� 33 MAILING ADDRESS /V .LJ CITY, STATE, ZIP leu bs.� ✓n T�i� f ezoel . FHONE e lb -1y CITY OF FEDERAL WAY BUSINESS LIC&NSE NUMBER . EXPIRATION DATE FAX NUMBER 2,0 - 6 S- /0 /1 /1- 60' /7- A., 40 (;s3 ) & 71, - ?V3 CONTRACTOR•e REOISTRATION NUMBER X"MATION DATE I9 -MAIL ADDRESS COMPANY NAME �..�i APPLICANT NAMB �o.�51 OFFICE PHONE fs74. - Ffs MAILING ADDRESS /-//( R &Y SI). CITY, STATE, ZIP to el .1 CELL PHONE �r� S10 _ e lb -1y RELATIONSHIP TO PROJECT FAX NUMBER ❑ Architect o Tenant 0-*Kgent D Other NAME T PRIMARY PHONE E-MAIL ADDRESS 1Jt� K-%•-4 L� �oc-� FSS (aS3) YX - IF F SM NAME P 19.27.098: . r re nder rmation isfect value exceeds $5,000 . MAI RB33 CITY. STATE, NB ( ) - EXIOTING USE Ce N A4 -'-e"4" PROPOSED USE C a'''t!'tt ✓t EXISTING ASSESSED/APPRAISED VALUE $ VALUE OF PROPOSED WORK $ SPRINKLERED BUILDING? o YES O NO FIRE 81UPPRESSION SYSTEM PROPOSED/REQUIRED? o YES O NO WATER SERVICE PROVIDER O LAKEHAVEN o HIGHLINE O TACOMA O PRIVATE (WELL) SEWER SERVICE PROVIDER o LAKEHAVEN o HIGHLINE o PRIVATE (SEPTIC) PROJECT ••• AREA DESCRIPTION BASEMENT AREAS a REPAIR a TENANT IMPROVEMENT SQ. FT. PROPOSzD SQ. FT. TOTAL SQ. FT. FIRST o NO ZONING DESIGNATION SECOND o YES o NO NEW ADDRESS REQMRED? THIRD IIP/SEPA/SU? a YES. o NO ADDITIONAL FLOORS (DESCRIBE) a YES a NO DEMO PERMIT REQUIRED? a YES DECK (O COVERED OR O UNCOVERED?) GARAGE 13 CARPORT 11 NUMBER OF FLOORS uO O rsa9810 TO7'i°'. r°r'as OMar ronuneaoesssr "AALer '•NEW HOMBS ONLY- . NUMBER OF BEDROOMS ESTIMATED SELLING PRICE $ Indicate number of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. MECf "CAL Value of Mechanical Work $ (A COPY OF BID OR ESTIMATE MUST BB INCLUDED WITH APPLICA77019 AIR HANDLING UNITS BBQ3 BOILERS COMPRESSORS DUCTS BATHTUBS lorT,b/showucon," DISHWASHERS DRINKING FOUNTAINS ELECTRIC WATER HEATERS HOSE BIBBS EVAPORATIVE COOLERS FANS FIREPLACE INSERTS FURNACES GAS LOG SETS LAVS paum. strilra) RAINWATER SYST SHOWERS SINKS SUMPS I GAS PIPE OUTLETS GAS WATER HEATERS HOODS Ico --udq RANGES REFRIO. SYSTEMS' URINALS VACUUM BREAKERS WATER CLOSETS (rdhq WASHING MACHINES WOODSTOVES MISC (Describe) MISC (Describe) I certift under penalty of perjury that l am the property owner or authorised agent of the property owner. I eertVy that to the best of my knowledge, the irybrmation submitted in support of this permit application to true and correct. t eertW that I will comply with all applicable City of Federal ,Way regulations pertaining to the work authorised by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I flurther agree to hold harmless the City of Federal Way as to any claim /including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees; upon -the accuracy of the information supplied to the city as apart of this application. SIGNATURE: I DATE Property Owner end/or Authorized Agent .oNNW o ADDITION a ALTERATION a REPAIR a TENANT IMPROVEMENT BUILDING SHELL ONLY? o YES. a NO BASIC PLAN? o YES o NO ZONING DESIGNATION CHANGE OF USE? o YES o NO NEW ADDRESS REQMRED? a YES a NO IIP/SEPA/SU? a YES. o NO PLATTED LOT? a YES a NO DEMO PERMIT REQUIRED? a YES a NO. Bulletin 11100=August 16, 2007 Page 2 of 4 . k\Handouts\Permit Application ELECTRICAL PERMIT INFORMATION RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ Single Family Square Feet (First 1300 !t2- 6111.00; Each addh 500 ft2 - $35.50) ❑ Detached outbuilding or garage (Inspected with service) $47.00 ❑ Detached outbuilding or garage (Inspected separately) $74.00 NEW MDLTI-FAMMT (three units or more) ❑ 0 to 200 amp Service Feeder ❑ Up to 200 amp $120.50 $ 35.50 ❑ 201- 400 amp 149.50 74.00 13 401 - 600 amp 205,00 102.00 ❑ 601 - 800 amp 262.00 140.50 ❑ Over 800 amp 375.60 280.50 ALTERED SINGLE/MULTI FAMILY ❑ d of circuits to be added/altered (1-4 circuits -$74.00; Add'n circuits $7.00/ea) ❑ Mast or meter repair $55.00 MANUFACTURED HOME6 ❑ Service or feeder only $74.00 ❑ Service and feeder $120.50 COMMERCIAL NEW COMMERCIAL/INDUSTRIAL SERVICE ❑ 0 to 100 amp ❑ 101- 200 amp ❑ 201 - 400 amp ❑ 401- 600 amp ❑ 601- 800 amp E3 801 - 1000 amp ❑ Over 1000 amp Seruke or Feeder Each Add'n $120.50. $ 74.00 149.50 Service or Feeder ❑ 0 to 200 amp $92.50. ❑ 201 - 600 amp 149.50 ❑ over 600 amp 225.50 ❑ d of circuits to be added/altered (1-4 circuits -$74.00; Add'n circuits $7.00/ea) ❑ Mast or meter repair $55.00 MANUFACTURED HOME6 ❑ Service or feeder only $74.00 ❑ Service and feeder $120.50 COMMERCIAL NEW COMMERCIAL/INDUSTRIAL SERVICE ❑ 0 to 100 amp ❑ 101- 200 amp ❑ 201 - 400 amp ❑ 401- 600 amp ❑ 601- 800 amp E3 801 - 1000 amp ❑ Over 1000 amp Seruke or Feeder Each Add'n $120.50. $ 74.00 149.50 94.50 280.00 111.00 327.00 131.00 423.00 179.00 516.50 216.06 563.00 300.00 ❑ Over 600 volts surcharge $94.50 ❑ Mast or meter repair $102.00 ALTERED COMMERCL4L/INDUSTRIAL Servick or Feeders ❑ 0 to 200 amp $120.50 ❑ 201 - 600 amp 280.50 ❑ 601- 1000 amp 423.00 ❑ over 1000 amp 471.06 ❑ tt of circuits to be hdded/altered (1-5 circuits - $94.50; Add'n circuits, $7.00/ea) COMMERCIAL/INDUSTRIAL PLAN REVIEW $94.50 plus 35% of Permit Fee ❑ Service - 1,000 amps or greater ❑ Medical/Educational/Institutional Facility TEMPORARY SERVICE MOBILE HOME/RV PARR Resident iaVMu1fl.Family $65.00 ❑ tl of service or feeders (First service/feeder-$74.00; each addh 448.00) ConmerefaWndustriai Service or Bleeder Ampacity ❑ 0 - 100 amps $ 74,00 ❑ 101- 200 amps 94.50 ❑ 201- 400 amps 111.00 ❑ 401-•600 amps 149.50 ❑ over 600 amps 162.00 MISCELLANEOUS SERVICE/EQUIPMENT Er i! of Thermostats ❑ 4 of Signs (First -$55:00; addh-$17.00/ea) (First sign -$55.00; addh sign $26.00/ea) ❑ Low Voltage U. nu pool/hot tub ................. $111.00 Square Feet to be served by system(s) (Includes additional circuit, if required) 13 Fire Alarm* system (3 Yard Pole meter loops ....... :.......... ... $74.00 O security Alarm system ❑ Additional Plan Review $111.00 /hour Voice Cabling /hour 13 Data Cabling (for modified submittals) E3 ❑ Automation Fee on all Permits .. $5.00 1It 2500 it1-$65.00; Each addh 25001t2-17.00) • An WAC 2.4&469]o(5A)# a rr) Bulletin 1!100 -August 16, 2007 Page 3 of 4 klHandouts\Permit*Application