Loading...
17-102600Ir if a 0 A City or Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: BURLAKOV Project Address: 31811 6TH PL SW w .,Vb t Building - Single Family F�ILE Permit #:17 -102600 -00 -SF Inspection Request Line: (253) 835-3050 Parcel Number: 072104 9093 Project Description: NEW - Construction of a 6792 square foot, 2 -story, single-family residence with a 120 square foot covered entry, 1538 square foot attached garage and 368 square foot deck. Includes plumbing and mechanical. ***5 bedrooms; Estimated selling price $500000.** Owner Applicant Contractor Lender NIKOLAY BURLAKOV SARAH WEIGHTARCHITECTS OWNER IS CONTRACTOR OWNER IS LENDER 5115 NE 5TH CIR NORTHWEST Type V - B New / Additional Sq. Feet - Deck ........................... RENTON WA 98059 18915 142ND AVE NE SUITE 100 1538 Mechanical to be Included? ..................................... USA WOODINVILLE WA 98072 10000 Mechanical Work Valuation? .................................. Census Category: 101 - New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) Additional Permit Information New / Additional Sq. Feet - I st Floor ..................... 2836 New / Additional Sq. Feet - 2nd Floor.................... 2078 New / Additional Sq. Feet - 3rd Floor ..................... 0 New / Additional Sq. Feet - Basement.................... 1878 Basic Plan?........................................................... No Occupancy #1 - Construction Type......................... Type V - B New / Additional Sq. Feet - Deck ........................... 368 New / Additional Sq. Feet - Garage........................ 1538 Mechanical to be Included? ..................................... Yes Plumbing Work Valuation?..................................... 10000 Mechanical Work Valuation? .................................. 10000 Number of Stories................................................... 2 New / Additional Sq. Feet - Other ........................... 120 Plumbing to be Included? ........................................ Yes New / Additional Sq. Feet - Total ........................... 8818 Will Certificate of Occupancy be Issued?............... Yes Occupancy #I -Use ................................................ Residence (1 or 2 Comprehensive Plan Designation........................... SF - High -Density family) Residential Zoning Designation ................................................. RS 9.6 Total Valuation: 852,109.22 Air Conditioners - Stand Alon( 1 Ducting 1 Fireplace Inserts 2 Furnaces 1 Hot Water Tanks 1 Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 7 Showers 3 Sinks 2 Water Closets 5 Hose Bibbs 3 CONDITIONS: PER FWRC 13.31.050 NFPA 13D SPRINKLER SYSTEM IS REQUIRED. NO FRAMING INSPECTION UNTIL SPRINKLER SYSTEM APPROVED FOR COVER BY SKFR 24 Tree units are required to be plapted before final inspection. Planning Final required for tree insnection. Second sheet site elan AWshows 24 renlacement tree units. Jim Harris 1 ✓t.a lel . ­ I . . IV•7 s .y _-.i _. At • A City Right of Way Permit is require for the driveway connection to 6th Ave SW. Contact Kathleen Mathena at (253) 835-2625 for the permit materials. The Right of Way permit mast be finalled, prior to Building Final PERMIT EXPIRES Sunday, 28 January, 2018 Permit Issued on Tuesdav, August 1, 2017 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy anJ the 9s6 will be in a rda a with the laws, rules and regulations of the State of W o he City of Federal Way. / ? Owner or agent: — Date: City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: BURLAKOV Address: 31811 6TH PL SW Permit # 17 -102600 -00 -SF Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) Owner Name: NIKOLAY BURLAKOV Owner Address: 5115 NE 5TH CIR RENTON WA 98059 USA Building Official �z ate The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/ occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. THIS CARD IS TO REMAIN ON-SITE' • cwv OF Construction Inspection Record FWeral Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 17102600 00 Address: 318116TH PL SW Project: YELENA BURLAKOV FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. Foundation Wall (4115) Q Drainage/Downspout (4040) ® Plumbing Groundwork (4190) Approved to place concrete Approved to backfill �� ApPpPr{o�v�ed to cover, By Arri Date �2, i By Date By Date S 0 SWM Precon Site Mtg (4400) 0 Initial Erosion Control (4365)113Y 3❑ Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete Ely Date By Date By Date 'T I!51 Foundation Wall (4115) Q Drainage/Downspout (4040) ® Plumbing Groundwork (4190) Approved to place concrete Approved to backfill �� ApPpPr{o�v�ed to cover, By Arri Date �2, i By Date By Date S 0 Slab/Concrete Floor (4255) ® Underfloor Framing (4285) ® Floor SheathingL(41(015)Approved to place concrete Approved to sheath floor Approved to install floBy Approved �) Date 'O{tS1 By A0 Date 0 -7 By 19d Date By Date By Date Shear Walls (4245) PP 0 Roof Sheathing (4220) Rough Plumbing (4230) QP Approved to install siding Approved to install roofmg Approved By Date 5 tj Date By L Date 2 H Mechanical Rough -in (4165) ® Gas Piping (4125);JE FirelDrafti Stops (4095) Approved Approved to release test Approved By dd __ /d Date By � Date y Date ® Interim Erosion Control (4370) Prier b scheduling a Framieg �pect�; � Framing (4120) Approved Electrical, Plumbing do Mechanical Rough -in Approved to insulate and VhaM aft Stop inspections must be sig•ed- By Date off and approved. IBC 109.3.4 B rf Date gik 1ti Insulation (4150) 0L7Approved allboard Nailing (4130) ® Final Erosion Control (4375) Approved to install wall to install mud & tape Approved By ld L Date v/ % Date jo --�--� By Date 91 Final - Mechanical (4065) Final - Plumbing (4075) 90 Final - Building (4050) By Approved AJ Date ?-/"?,6/1j� By Approved rQ�J Date 11-161 " By Approved /� Date Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date is 1�W OF Federal Way Building Division 3332406ghth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: �5 1-�; l, i L. jt�' V N 5L." PERMIT#: IF YOU HAVE QUESTIONS CALL (253) 835- 9- In 2 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of PITZER & ASSOCIATES, PLLC S R U C T U R A L E N G I N E E R S 2722 Colby Avenue, Suite 632, Everett, WA 98201 Office: (425)322-3940 email: tommyt42k@hotmail.com May 8, 2018 Sarah Weight Architects NW 18915 142°d Ave NE Suite 100 Woodinville, WA 98072 SUBJ: Plan Revisions for 3181161 Place SW, Federal Way, WA Sarah: The purpose of this letter is to document revisions to the approved set of plans. Item (1). The approved set of plans call for a PSL 2.0 beams at the locations shown in enclosure (1). RidgeLam LVL beams were inadvertently used. The RidgeLam beams are structurally adequate for the anticipated loads. Item (2). The approved set of plans call for balloon framed walls at the location shown on enclosure (2). The wall was framed with a double top plate at mid -height. Strap the upper studs to the lower studs with a 4'-0" section of CS 16 strapping on both the inside and the outside narrow faces. Item (3). 3 — 5/8" diameter holes were drilled in beam 32 to allow for radiant floor heating. The beam is supported by a 2x6 framed wall at this location: Therefore, the holes are satisfactory. Item (4). a. The approved set of plans call for beam 09 to be a GLB 3.5x9 24F -V4. A 4x10 DF# 1 was used instead. The capacity of the 4x 10 does not meet the anticipated demand. However, a 6x10 DF#1 exceeds the anticipated demand, therefore, the 6x10 is structurally inadequate for the anticipated loads. b. The approved set of plans call for beam 18 to be a PSL 5.25x11.875 2.OE. A 6x12 DF#1 was used instead. The capacity of the 6x12 exceeds the anticipated demand, therefore, the 6x12 is structurally adequate for the anticipated loads. c. The approved set of plans call for beam 18A to be a PSL 5.25x11.875 2.OE. A 6x 12 DF# 1 was used instead. The capacity of the 6x 12 exceeds the anticipated demand, therefore, the 6x12 is structurally adequate for the anticipated loads. d. The approved set of plans call for beam 40 to be a GLB 3.5x9; 24F -V4. A 4x10 DF#1 was used instead. The capacity of the 4x10 exceeds the anticipated demand, therefore, the 4x10 is structurally adequate for the anticipated loads. 17-130-2 Plan Revisions.docx If there are any questions about this report or if I can be of any further assistance, please feel free to call me at the above number between 8 AM and 5 PM Monday - Friday. I look forward to working with you in the future. See enclosure (1). Sincerely, Thomas J. Pitzer, PE cc: �P OF WAS 1 - File 17-130 1 �Q Ob Cp A -o 40881 �O�FSEG IST�RF'01�� �AL EXPIRES 12-02-18 Page 2 of 2 JOB NAME : Ruffhouse -Mikolay, Burlakov Residence ADDRESS: 5115 NE 5th Circle, Renton, WA 98059 JOB Number: CC8506 i7 -(so Compession Compession Tension Bending Horizontal Perp To Grain Parallel To Parallel to Product MOE (Fe) Shear (F„) (Fe) Grain (Fj Grain (F,j Parallam PSL 2.0 x 106 2,900 290 750 2,900 2,025 RigidLam LVL 2.0 x 106 3,100 290 750 3,000 2,100 i7 -(so ITL --M 1 . -= LTt `2 Ir E- 0 33 Z03, (OX6 P057' 32 4 Pitzer & Associates, PLLC Project Title: 2722 Coby Ave Engineer: Project ID: Suite 632 Project Descr: Everett, WA 98201 NMI 8 MAY 2018, 4:35PM Description : BM 18 Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 0.9741 Maximum Shear Stress Ratio - 0.551 : 1 Load Combination Set: IBC 2015 Section used for this span 6x12 D(0.48) r(0.79) Material Properties D 0 2925 Lr 0 4875 124.02 psi FB : Allowable Analysis Method: Allowable Stress Design Fb + 1,000.0 psi E: Modulus of Elasticity Load Combination IBC 2015 Fb- 1,000.0 psi Ebend-xx 1,700.Oksi Span # 1 Fc - Prll 1, 500.0 psi Eminbend - xx 620.0 ksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Max Downward Transient Deflection Wood Grade : No.1 Fv 180.0 psi Max Upward Transient Deflection Beam Bracing Beam is Fully Braced against lateral -torsional buckling Ft 675.0 psi Density 31.20pcf D(0.64lLr(1.4) 0.9741 Maximum Shear Stress Ratio - 0.551 : 1 6x12 Section used for this span 6x12 D(0.48) r(0.79) 1,218.04psi D 0 2925 Lr 0 4875 124.02 psi FB : Allowable 1,250.00psi Fv : Allowable 225.00 psi D O 06 0 (O. 1,0) 21 Load Combination Location of maximum on span = -Lr Span # where maximum occurs = Span # 1 Span # where maximum occurs = M Yd h'Zy #�� r �M1y�i✓ ZF.`��kt� ::; �1 ,,I^".. i 6x12 6x12 Max Downward Transient Deflection Span = 12.0 ft 1233 >=360. Span = 8.0 ft Max Upward Transient Deflection 0.000 in Ratio= 0 <360.0 = t£�-r -c �� , �� � n Service loads entered Load Factors will be applied for calculations Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.0250 ksf, Tributary Width =19.50 ft Point Load : D = 0.840, Lr =1.40 k @ I D ft Load for Span Number 2 Varying Uniform Load: D= 0.0150->0.0, Lr= 0.0250->0.0 ksf, Extent = 0.0 —>> 8.0 ft, Trib Width = 4.0 ft Point Load : D = 0.480, Lr = 0.790 k @ 8.0 ft aximum Bending Stress Ratio = Section used for this span 0.9741 Maximum Shear Stress Ratio - 0.551 : 1 6x12 Section used for this span 6x12 fb : Actual = 1,218.04psi fv : Actual = 124.02 psi FB : Allowable 1,250.00psi Fv : Allowable 225.00 psi Load Combination Locat on of maximum on span = +D+Lr 12.000ft Load Combination Location of maximum on span = +D+Lr Span # where maximum occurs = Span # 1 Span # where maximum occurs = 11.061 ft Span # 1 Maximum Deflection Max Downward Transient Deflection 0.117 in Ratio= 1233 >=360. Max Upward Transient Deflection 0.000 in Ratio= 0 <360.0 Max Downward Total Deflection 0.186 in Ratio= 773>=180. Max Upward Total Deflection 0.000 in Ratio= 0<180.0 Maririnum forces & 5tes-€ar.oad+ifia`r�ttr Pitzer & Associates, PLLC Project Title: 2722 Coby Ave Engineer: Project ID: Suite 632 Project Descr. Everett, WA 98201 Pond: 8 MAY 2018, U6W Description: BM 18 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V Cd C FN C i Cr C m C t C L M fb F'b V D Only fv F'v Length = 12.0 It 1 0.541 0.297 0.90 1.000 1.00 1.00 1.00 1.00 1.00 4.92 486.87 0.00 900.00 0.00 2.03 0.00 48.14 0.00 162.00 Length = 8.0 It 2 0.541 0.297 0.90 1.000 1.00 1.00 1.00 1.00 1.00 4.92 486.87 900.00 0.76 48.14 162.00 +D+Lr 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =12.0 ft 1 0.974 0.551 1.25 1.000 1.00 1.00 1.00 1.00 1.00 12.31 1,218.04 1250.00 5.23 124.02 225.00 Length = 8.0 ft 2 0.974 0.551 1.25 1.000 1.00 1.00 1.00 1.00 1.00 12.31 1,218.04 1250.00 1.87 124.02 225.00 +D+0.750Lr 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =12.0 ft 1 0.828 0.467 1.25 1.000 1.00 1.00 1.00 1.00 1.00 10.46 1,035.25 1250.00 4.43 105.05 225.00 Length = 8.0 It 2 0.828 0.467 1.25 1.000 1.00 1.00 1.00 1.00 1.00 10.46 1,035.25 1250.00 1.59 105.05 225.00 +0.60D 1.000 1.00 1.00 1A0 1.00 1.00 0.00 0.00 0.00 0.00 Length = 12.0 It 1 0.183 0.100 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.95 292.12 1600.00 1.22 28.88 288.00 Length = 8.0 It 2 0.183 0.100 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.95 292.12 1600.00 0.46 28.88 288.00 "`. Support notation : Far left 1s #1 Load Combination Support 1 Support 2 Support 3 Values in KIPS Overall MAXimum 5.790 7.99 Overall MINimum 3.593 4.847 D Only 2.197 3.147 +D+Lr 5.790 7.994 +D+0.750Lr 4,892 6.782 +0.60D 1.318 1.888 Lr Only 3.593 4.847 Pitzer & Associates, PLLC 2722 Coby Ave Suite 632 Everett, WA 98201 Project Tide: Engineer. Project ID: Project Descr: M!M!"V"MMftCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb+ 1,000.0 psi E: Modulus ofElasfiaty Load Combination iBC 2015 Fb - 1,000.0 psi Ebend- xx 1,700.Oksi 273.17psi Fc - Pill 1,500.0 psi Eminbend - xx 620.Oksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Load Combination Location of maximum on span = Wood Grade : No.1 Fv 180.0 psi Span # where maximum occurs = Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 675.0 psi Density 31.20pcf tIeA Service loads entered Load Factors will be applied for calculations Beam self weight calculated and added to loads Uniform Load : D=0.0150, Lr = 0.0250 ksf, Tributary Width = 7.0 it aximum Bending Stress Ratio = 0.2191 Maximum Shear Stress Ratio = 0.105 :1 Section used for this span 6x12 Section used for this span 6x12 fb : Actual _ 273.17psi fv : Actual = 23.58 psi FB : Allowable = 1,250.00psi Fv : Allowable = 225.00 psi Load Combination Location of maximum on span = +D+Lr+H 4.335ft Load Combination Location of maximum on span' = +D+Lr+H 0,000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0,019 in Ratio = 5509>=240 Max Upward Transient Deflection 0.000 in Ratio = 0 <240 Max Downward Total Deflection 0.032 in Ratio = 3282>=180. Moment Values Max Upward Total Deflection 0.000 in Ratio = 0<180.0 Segment Leith -------------------------------------------- Load Comt>inatbn Max Stns Ratios Moment Values Shear Values Segment Leith Span # M V C d C FN C i 0 r C m t 0 L M fb Pb V fv +D+H F'v Length = 8.670 it 1 0.123 0.059 0.90 1.000 1.00 1.00 1.00 1.00 1.00 1.12 110.40 0.00 900.00 0.00 0.40 0.00 9.53 0.00 162.00 +D+L+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.670 ft +D+Lr+H 1 0.110 0.053 1.00 1.000 1.00 1.00 1.00 1.00 1.00 1.12 110.40 1000.00 0.40 9.53 180.00 Length = 8.670 it 1 0.219 0.105 1.25 1.000 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 z 0.00 0.00 0.00 0.00 +D+S+H 1.000 1.00 1.00 1.00 1.00 1.00 2.76 273.17 1250.00 0.99 23.58 225.00 Length = 8.670 ft 1 0.096 0.046 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1.12 110.40 0.� 1150.00 4.00 0.40 0.00 9.53 0.00 207.00 +D+0.756Lr+0.750L+H 1.004 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Pitzer & Associates, PLLC Project Title: 2722 Coby Aveineer.. Suite 632 Project Descr: Project ID: Everett, WA 98201 PnnWd 7 MY 2078, 8.05PM Description : BM 18A Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr C m C t CIL M th Fb V fv Fv Length = 8.670 It 1 +D+0.750L+0.750S+H 0.186 0.089 1.25 1.000 1.00 1.00 1.00 1.00 1.00 2.35 232.48 1250.00 0.85 20.07 225.00 Length = 8.670 ft 1 0.096 0.046 1.15 1.000 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.12 110.40 0.00 1150.00 0.00 0.40 0.00 9.53 0.00 +0+0.60W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 207.00 0.00 Length = 8.670 ft 1 0.069 0.033 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.12 1110.40 1600.00 0.40 9.53 288.00 +D+0.70E,+i 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.670 ft 1 +D+0.750Lr+0.750L+0.450W+H 0.069 0.033 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.12 110.40 1600.00 0.40 9.53 288.00 Length = 8.670 It 1 0.145 0.070 1.60 1.000 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.35 0.00 0.00 0.00 0.00 +D+0.750L+0.750S+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 232.48 1600.00 0.85 20.07 288.00 Length = 8.670 It 1 0.069 0.033 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.12 110.40 0.00 1600,00 0.00 0.40 0.00 9.53 0.00 288.00 +D+0.750L+0.750S+0.5250E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.670 It 1 0.069 0.033 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.12 110.40 1600.00 0.40 9.53 288.00 40.60D+0.60W+0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Lergth = 8.670 It 1 0.041 0.020 1.60 1.000 1.00 1.00 1.00 1.00 1.00 0.67 66.24 1600.00 0.24 5.72 288.00 40.60D+0,70E+0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.670 ft 1 0.041 0.020 1.60 1.000 1.00 1.00 1.00 1.00 1.00 0.67 66.24 1600.00 0.24 5.72 288.00 now= Ems Support notation: Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall imum1.273 1.271 Overall MINimum 0.759 0.759 40+H 0.515 0.515 +D+L+H 0.515 0.515 +D+Lr+H 1.273 1.273 4D+S+H 0.515 0.515 +D+0.750Lr+0.750L+H 1.064 1.084 +D+0.750L+0.750S+H 0.515 0.515 +D+0.60W+H 0.515 0.515 +0+0.70E+H 0.515 0.515 +0+0.7501-r+0.750L+0.450W+H 1.084 1.084 +0+0.750L40.750S+0.450W+H 0.515 0.515 +0+0.750L+0.750S40.5250E+H 0.515 0.515 +0.60D+0.60W+0.60H 0.309 0.309 +0.60D+0.70E+0.60H 0.309 0.309 D Only 0.515 0.515 Lr Only 0.759 0.759 L Only S Only W Only E Only H Only Pitzer & Associates, PLLC Project Title: 2722 Coby Ave Engineer. Suite 632 Project Descr: Everett, WA 98201 Proiect ID: Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb + Load Combination OC 2015 1000 psi E: Modulus of Elasfiafy Fb - 1000 psi Ebend- xx 1700ksi Fc - PrIl Wood Species : Douglas Fir - Larch Fc - Perp 1500 psi 625 psi Eminbend - xx 620 ksi Wood Grade : No.1 Fv 180 psi = FB : Allowable = Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 675 psi Density 31.2pcf L Span=:65t3'tE' r t Service loads entered Load Factors will be applied for calculations Beam self weight calculated and added to loads Uniform Load : D=0.0150, Lr = 0.0250 ksf, Tributary Width= 21.0 ft Point Load : D=0.730, Lr =1.20 k o 6.0 ft Maximum Bending Stress Ratio _ Section used for this span _ 0.7961 Maximum Shear Stress Ratio - 0.465: 1 fb : Actual 4x10 Section used for this span 4x10 = FB : Allowable = 1,194.62psi 1,500.00psi fv : Actual Fv : Allowable - 104.63 psi Load Combination +D+Lr+H Load Combination - - 225.00 psi Location of maximum on span = 3.416ft Location of maximum on span; = +p +H O r}f Span #where maximum occurs - Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.061 in Ratio = 1278>=240 Max Upward Transient Deflection 0.000 in Ratio = p <240 Max Downward Total Deflection 0.098 in Ratio = 792>=160 Max Upward Total Deflection 0.000 in Ratio = 0<180.6 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V Cd C Fly C r C m C t C L M tb Fb +D�+1 .1r, V fv F v Length = 6.50 ft 1 0.420 0.245 0.90 1.200 1.00 1.00 1.00 1.00 1.00 1.89 453.93 0.00 1080.00 0.00 0.00 0.00 0.86 39.76 162.00 Length = 6.50 ft 1 0.376 0.221 1.00 1.200 1.00 1.00 1.200 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 453.93 0.00 0.00 0.00 0.00 +D+Lr+H 1.200 1.00 1.00 1.89 1.00 1.00 1.00 1200.00 0.86 39.76 180.00 Length = 6.50 ft 1 0.796 0.465 1.25 1.200 1.00 1.00 1.00 1.00 1.00 4.97 1,194.62 0.00 1500.00 0.00 0.00 0.00 2.26 104.63 225.00 Pitzer & Associates, PLLC Project 7itie: 2722 Coby Ave Engineer. Proiect ID: Suite 632 Project Descr: Everett, WA 98201 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C I Cr C In C t C L M fb Pb V tv Pv +D+S+H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 It 1 0.329 0.192 1.15 1.200 1.00 1.00 1.00 1.00 1.00 1.89 453.93 1380.00 0.86 39.76 207.00 +D+0.75OLr+0.750L+H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.673 0.393 1.25 1.200 1.00 1.00 1.00 1.00 1.00 4.20 1,009.45 1500.00 1.91 88.41 225.00 +D+0.750L+0.750S+H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.329 0.192 1.15 1.200 1.00 1.00 1.00 1.00 1.00 1.89 453.93 1380.00 0.86 39.76 207.00 +D+0.60W+H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.236 0.138 1.60 1.200 1.00 1.00 1.00 1.00 1.00 1.89 453.93 1920.00 0.86 39.76 288.00 +0+0.70E aH 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.236 0.138 1.60 1.200 1.00 1.00 1.00 1.00 1.00 1.89 453.93 1920.00 0.86 39.76 288.00 +D+0.750Lr+0.750L+0.450W+H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.526 0.307 1:60 1.200 1.00 1.00 1.00 1.00 1.00 4.20 1,009.45 1920.00 1.91 88.41 288.00 +D+0.750L.0.750S+0.450W+H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.236 0.138 1.60 1.200 1.00 1.00 1.00 1.00 1.00 1.89 453.93 1920.00 0.86 39.76 288.00 +0+0.750L+0.750S+0.5250E+H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 It 1 0.236 0.138 1.60 1.200 1.00 1.00 1.00 1.00 1.00 1.89 453.93 1920.00 0.86 39.76 288.00 +0.60D+0.60WA,60H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.142 0.083 1.60 1.200 1.00 1.00 1.00 1.00 1.00 1.13 272.36 1920.00 0.51 23.86 288.00 +0.60D+0.70EA.60H 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.142 0.083 1.60 1.200 1.00 1.00 1.00 1.00 1.00 1.13 272.36 1920.00 0.51 23.86 288.00 Support notation: Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimurn 2.901 4.534 Overall MINimum 1.799 2.814 +D+H 1.103 1.720 +D -+L41 1.103 1.720 +D+Lr+H 2.901 4.534 40+S.+H 1.103 1.720 +D+0.750Lr+0.750L+H 2.452 3.831 +D+0.750L+0.750S+fi 1.103 1.720 +0+0.60W+H 1.103 1.720 +D+0.70E+4 1.103 1.720 +D+0.750Lr+0.750L+0.450W+H 2.452 3.831 +D+0.750L+0.750S+0.450W+H 1.103 1.720 +D+0.750L+0.750S+0.5250E+H 1.103 1.720 +0.60D+0.60W40.60H 0.662 1.032 +0.60N0.70114601-1 0.662 1.032 D Only 1.103 1.720 Lr Only 1.799 2.814 L Only S Only W Only E Only H Only Pitzer & Associates, PLLC Project Title: 2722 Coby Ave Engineer. Project ID: Suite 632 Project Descr Everett, WA 98201 Description BM 09 Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Section used for this span 847.86psi fv : Actual 1,250.00psi Fv : Allowable +D+Lr+H Load Combination Set: IBC 2015 1.993ft Location of maximum on span Span # 1 Material. Properties 0.035 in Ratio = 2048 >=240 0.000 in Ratio = Analysis Method: Allowable Stress Design Load Combination IBC 2015 Fb + 1,000.0 psi E: Modulus of Elasticity 0 <180.0 Fb- 1,000.0 psi Ebend-xx 1,700.Oksi Fc - Pdl 1,500.0 psi Eminbend - xx 620.Oksi Wood Species :Douglas Fir- Larch Fc - Perp 625.0 psi 1.000 1 0.678 0.672 1.25 1.000 Wood Grade : No.1 Fv 180.0 psi 1.00 1.00 Ft Beam Bracing : Beam is Fully Braced against lateral -torsional buckling 675.0 psi Density 31.20pcf Sparc = 64 ft Service loads entered Load Factors will be applied for calculations Beam self weight calculated and added to loads Uniform Load : D = 0.0150, Lr = 0.0250 ksf, Tributary Width =18.0 ft Point Load: D =1.680, Lr = 2.70 k @ 1.0 ft aAmum Bending Stress Ratio = Section used for this span fb : Actual = FB: Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection i 0.6781 Maximum Shear Stress Ratio 6x10 Section used for this span 847.86psi fv : Actual 1,250.00psi Fv : Allowable +D+Lr+H Load Combination 1.993ft Location of maximum on span Span # 1 Span # where maximum occurs 0.035 in Ratio = 2048 >=240 0.000 in Ratio = 0 <240 0.057 in Ratio = 1261 >=180. 0.000 in Ratio = 0 <180.0 0.672: 1 6x10 151.22 psi 225.00 psi +D+Lr+H 0.000 ft Span # 1 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span# M V Cd C FN C i Cr Cm C r CI M f6 Fah v a. +D+H Length _ 6.0 ft +D+L+H Length = 6.0 It +D+Lr+H Length = 6.0 It 1 0.362 0.358 0.90 1.000 1.00 1.00 1.00 1.00 1.00 2.25 325.68 900.00 2.02 58.05 162.00 1.000 1 0.326 0.323 1.00 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 2.25 325.68 1000.00 2.02 58.05 180.00 1.000 1 0.678 0.672 1.25 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 r 0.00 0.00 0.00 0.00 5.85 847.86 1250.00 5.27 151.22 225.00 Pitzer & Associates, PLLC Project True. 2722 Coby Ave Engineer:� DProtect ID: Suite 632 Everett, WA 98201 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C I C, Cm C t CL M ib Fb V fv Fv +D+S+H Length = 6.0 It 1 0.283 0.280 1.15 1.000 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.000.00 1.00 0.00 0.00 0.00 +D+0.750i_r+0.750L+H 1.000 1.00 1.00 1.00 1.00 1.00 2.25 325.68 1150.00 2.02 58.05 207.00 Length = 6.0 It 1 0.574 0.569 1.25 1.000 1.00 1.00 1.00 1.00 _ 1.00 4.95 717.32 0.00 1250.00 0.00 4.46 0.00 127.93 0.00 225.00 +0+0.750L+0.75pS+Hl 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.0 ft 1 +D+0.60W+H 0.283 0.280 1.15 1.000 1.00 1.00 1.00 1.00 1.00 2.25 325.68 1150.00 2.02 58.05 207.00 Length = 6.0 ft 1 0.204 0.202 1.60 1.000 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 +0+0.70E+Hi 1.000 1.00 1.00 1.00 1.00 1.00 2.25 325.68 1600.00 2.02 58.05 288.00 Length = 6.0 It 1 0.204 0.202 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.25 325.68 0.00 1600.00 0.00 2.02 0.00 58.05 0.00 288.00 +D+0.7501f+0.750L+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.0 ft 1 +0+0.750L+0.750S+0.450W+H 0.448 0.444 1.60 1.000 1.00 1.00 1.00 1.00 1.00 4.95 717.32 1600.00 4.46 127.93 288.00 Length = 6.0 It 1 0.204 0.202 1.60 1.000 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.25 325.68 0.00 1600.00 0.00 2.02 0.00 58.05 0.00 288.00 +D+0.750L+0.750S+0.5250E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.0 ft 1 0.204 0.202 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.25 325.68 1600.00 2.02 58.05 288.00 +0.60D+0.60W+0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.0 ft 1 +0.60D+0.70E+0.60H 0.122 0.121 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.35 195.41 1600.00 1.21 34.83 288.00 Length = 6.0 ft 1 0.122 0.121 1.60 1.000 1.000 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.35 195.41 0.00 1600.00 0.00 1.21 0.00 34.83 0.00 288.00 Support notation : Far left Is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 5.844 2.924 Overall MINimum 3,600 1.800 +D+H 2.244 1.124 +D+L+H 2.244 1.124 +D+Lr+H 5.844 2.924 +D+S+H 2.244 1.124 _ +D+0.750Lr+0.750L+H 4.944 2.474 +D+0.750L+0.750S+H 2.244 1.124 +D+0.60W+4 2.244 1.124 +D+0.70E+H 2.244 1.124 +0+0.750Lr+0.750L+0.450W+H 4.944 2.474 +0+0.750L+0.750S+0.450W+H 2.244 1.124 +D+0.750L+0.750S+0.5250E+H 2.244 1.124 +0.60D+0.60W+0.60H 1.346 0.674 +0.60D+0.70E+0.60H 1.346 0.674 D Only 2.244 1.124 Lr Only 3.600 1.800 L Only S Only W Only E Only H Only 5/9/2018 Engineering revision 2 messages Gmail - Engineering revision Nikolay Burlakov <bdesignmg@gmail.com> Sarah Weight <sarah@architectsnw.com> Wed, May 9, 2018 at 10:54 AM To: Nikolay Budakov <bdesignmg@gmail.com> Nikolay, Tom Pitzer's response to the items I listed below are attached for you. Let me or Tom know if you have any questions. I'll find out what Tom's fee is for the changes. 1. Chinook lumber replaced 4 PSL beams with the same size Ridge -lam beams. These beams are circled in the attached photo. A chart shows the beam property comparison. The inspector would like your OK for the replacements. 2. In the corner of the great room we have full height studs called out. The framers did not balloon frame this — there's a double plate interrupting the studs. The inspector would like your OK for this. 3. There are 4 new holes in the 5.5x18 GLB over the basement— Beam #29. The holes are 5/8" diameter and are shown in the attached photo 4. Solid sawn DF #1 beams were used in place of PSL and GLBs at 4 locations supporting roof framing: Beam #09 (Master window header, 4x10 used), Beam #40 (Bedroom 4 window header, 4x10 used), and beams 18 and 18-A at the curved stair comer (6x12 used). Nikolay would like to know if there's something he can add to the beams to make them adequate, or if they simply need to be replaced. I'm attaching the beam caics as well so you can take a look. Thanks, Sarah Weight Project Manager Architects Northwest, Inc. Office: 425-485-4900 (M -Th) Office Fax: 425-487-6585 Toll Free: 1 -888 -ARCH -100 Home Office: 425-745-5471 (Fri) www.architectsnw.com sarah@architectsnw.com 17-130 Plan Revisions.pdf 4685K Nikolay Buriakov <bdesignmg@gmail.com> Wed, May 9, 2018 at 11:00 AM To: Sarah Weight <sarah@architectsnw.com> Sarah you are amazing!!! Thank you and let me know how much I own you [Quoted text hidden[ https://mail.google.com/mail/u/1/?ui=2&ik=52d215cfd5&jsver—awrWbfDFcFs.en.&cbl=gmail—fe-180429.15—p3&view=pt&search=inbox&th=16346467b59f4c5c&sim ,� CITY Way Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: 31811 6th PL SW PERMIT#: 17-102600 IRC 106.4 - Work done onsite shall match the approved plans: 3 1/2"x 9" GLB missing in master bedroom and bonus room OPP—tail 12/A3 not complete /4" x 11 7/8" PSL m 16 straps missina sc height wall eer. all deck I stalled within 12" Aj 0100 ill plat X. Studs overnotched in garacie throughout. Add stud next to all affected ones 6x6 Dost missina at bottom of stairs in basement 413edroom windows in basement taller than 44" sill height maximum foregress Provide en ineer a)nroval for holes drilled in alu-lam beams in basement area VX 3"1 2"x x 6" GLB ost missing in basement. Dimensional post installed currently More corrections may potentiall follow on next inspection Lower deck not inspected at this time. Do now cover until after next inspection c�1w�tC e� n CA C0"r'p144_- IF YOU HAVE QUESTIONS CALL Andy (253) 835 2639 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. i/1/18 AN Date Inspector DO NOT REMOVE THIS NOTICE (� tl,n s LAOCkg_ '- A �j — � 1(0 Page 1 of 3 Wessel, Jonas & Assoc., Inc. PO BOX 99681 Tel: 253-581-6107 Lakewood, Washington 98496 E-mail: ionas.nete(d2nhooxom LAND USE PLANNING * SURVEYING * SUBDIVISIONS Date: March 13, 2018 To: Nikolay Burlakov 5115 NE 5' Circle Renton, WA 98059 425-941-9953 On March 12, 2018 we verified a roof peak elevation and calculated middle paint of roof at the new house residence at 318116' Place in Federal Way. Lower floor elevation is 95.30 feet, main floor elevation is 105.06 feet and middle point elevation of the roof is 128.96 feet which is lower than maximum allowed elevation 129.50 feet by the City of Federal Way. 1f you have any question, please do not hesitate to call Sincerely, Peter Jonas P.L.S. President PITZER & ASSOCIATES, PLLC S RUC TURAL ENGINEERS 2722 Colby Avenue, Suite 632, Everett, WA 98201 Office: (425)322-3940 email: tommyt42k@hotmail.com April 25, 2018 Sarah Weight Architects NW 18915 142nd Ave NE Suite 100 Woodinville, WA 98072 SUBJ: Plan Revisions for 31811 6"' Place SW, Federal Way, WA Sarah: The purpose of this letter is to document revisions to the approved set of plans. Item (1). Beam 28, a GLB 5.5x18, has two 1.5" holes drilled at the center line 69" from one end and a second hole that is 52" from the end. The capacity of the beam is still great then the anticipated demand, therefore the beam is structurally adequate for the anticipated loads. See enclosure (1). Item (2). Beam 03, a PSL 5.25x11.875, has a 1.5" hole drilled at the center line 63" from the end. The capacity of the beam is still great then the anticipated demand, therefore the beam is structurally adequate for the anticipated loads. If there are any questions about this report or if I can be of any further assistance, please feel free to call me at the above number between 8 AM and 5 PM Monday — Friday. I look forward to working with you in the future. See enclosure (1). Sincerely, Thomas J. Pitzer, PE cc: 1 — File 17-130 PrD L 54 X It 7/9 (12 417 4 FjM 29 C-, LE, 752 X 12- 24. -7Z' 5-z4-7 5e� 77K V-: MC L �-'- t) SOLID SAWN FLOOR JOISTS WITH HOLE Zkt 2B P&A No: 17-130 Date: 4/26/18 SECTION PROPERTIES Al 45.375 A2 45.375 Ix" 257.361 Ix2 257.361 x1 c 2.750 x2c 2.750 y1 c 4.125 y2c 13.875 YC 9.000 Area 1 45.375 4.125 187.172 2 45.375 13.875 1 629.578 Eayc DESIGN CRITERIA DL 40 LL 10 50 PSF Trib Area 17 FT FLOOR JOIST DATA Total Length MOM FT Length to ALLOWABLE BENDING STRESS Fb 2400 psi Fv para 265 SOLID SAWN FLOOR JOISTS WITH HOLE 2S P&A No: 17-130 Date: 4/26/18 PARALLEL AXIS ix1 257.361 Ix2 257.361 Ixc= 2671.453 in4 Sxavail= in3 MOMENT M= w12 = 14051.5625 ft*lb 8 in*Ib SHEAR V= wi = LB 2 SHEAR A HOLE 70.833 pli V= 1207 LB Fv para= 24048.75 LB LB Therefore. OK MOMENT Mx= 1583351N*LB Sx Act < IN3 Therefore OK Project: M4750A3F-1DBR Location., BM BETWEEN KITCHEN & NOOK n MO 72 Uniformly Loaded Floor Beam [2015 International Building Code(2015 NDS)] 5.251N x 11.875 IN x 12.0 FT 2.0E Parallam - iLevel Trus Joist Section Adequate By: 38.6% Controlling Factor. Deflection StruCalc Version 10.0.1.4 5/26/2017 7:53:43 PM DEFLECTIONS Center 64.77 in3 LOADING DIAGRAM Area (Shear): 26.98 in2 62.34 int Live Load 0.22 IN L/665 528.68 in4 732.62 1n4 Moment: 15651 ft -lb 29815 ft4b Dead Load 0.06 in -5217 lb 12053 lb Total Load 0.28 IN U520 Live Load Deflection Criteria: 0480 Total Load Deflection Criteria: L/360 REACTIONS A B Live Load 4080 Ib 4080 lb Dead Load 1137 Ib 1137 Ib Total Load 5217 Ib 5217 lb Bearing Length 1.32 in 1.32 in BEAM DATA Center Span Length 12 ft Unbraced Length -Top 1 ft 12 ft Floor Duration Factor 1.00 -Notch Depth - - - - 0.00-- --- -- — ---- — -- -- - - --- --- - MATERIAL MATERIAL PROPERTIES FLOOR LOADING 2.0E Parallam - iLevel Trus Joist Side 1 Side 2 Base Values 6diusted Floor Live Load FLL = 40 psf 40 psf Bending Stress: Fb = 2900 psi Fb' = 2900 psi Floor Dead Load FDL = 10 psf 10 psf Cd --1-00 CI=1.00 CF=1.00 Floor Tributary Width FTW = 10 ft 7 ft Shear Stress: Fv = 290 psi FV = 290 psi Cd=1.00 Wall Load WALL = 0 plf Modulus of Elasticity: E = 2000 ksi E'= 2000 ksi BEAM LOADING Comp. -L to Grain: Fc - J- = 750 psi Fc - -L' = 750 psi Beam Total Live Load: wL = 680 plf Controlling Moment: 15651 ft4b Beam Total Dead Load: wD = 170 plf 6.0 ft from left support Beam Self Weight: BSW = 19 plf Created by combining all dead and live loads. Total Maximum Load: WT = 869 pif Controlling Shear -5217 Ib At support. Created by combining all dead and live loads. Comparisons with required sections: Read Section Modulus: 64.77 in3 123.39 in3 Area (Shear): 26.98 in2 62.34 int Moment of Inertia (deflection): 528.68 in4 732.62 1n4 Moment: 15651 ft -lb 29815 ft4b Shear: -5217 lb 12053 lb SOLID SAWN FLOOR JOISTS WITH HOLE IbK4 03 P&A No: 17-130 Date: 4/26/18 SECTION PROPERTIES Al 27.234 A2 27.234 Ix1 61.073 Ix2 61.073 x1 c 2.625 x2c 2.625 y1 c 2.594 y2c 9.28125 yc 5.938 Area 1 1 1 27.234 1 2.594 1 70.639 1 2 1 27.234 1 9.281252527-6--9-1� Eayc= DESIGN CRITERIA DL 40 LL 10 50 PSF Trib Area 17 FT FLOOR JOIST DATA Total Length , '_ FT Length to Hole fiA FT ALLOWABLE BENDING STRESS Fb 2900 psi Fv para 290 SOLID SAWN FLOOR JOISTS WITH HOLE PON 03 P&A No: 17-130 Date: 4/26118 PARALLEL AXIS Ix" 61.073 Ix2 61.073 Ixc 731.144 in4 Sxavail= in3 SHEAR (a) HOLE 70.833 pli V= 638 LB Fv para= 15795.94 LB > LB Therefore OK MOMENT Mx= 180731 IN`LB Sx Act < IN3 Therefore OK Protect: M4750A3F-1DBR Location: iBASEMENT BEAM F�) fq 'Z$ Mufti -Loaded Multi -Span Beam [2015 International Building Code(2015 NDS)] 5.5 IN x 12.0 IN x 11.5 FT 24F -V4 - Visually Graded Western Species - Dry Use Section Adequate By: 53.2% Controlling Factor: Deflection Live Load 0.19 IN 0735 Dead Load 0.05 in Total Load 0.24 IN U579 Live Load Deflection Criteria: U480 Total Load Deflection Criteria: 0360 HgACTIONS A B Live Load 3910 Ib 3910 lb Dead Load 1060 lb 1060 lb Total Load 4970 Ib 4970 lb Bearing Length 1.39 in 1.39 in Span Length 11.5 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 11.5 ft Live Load Duration Factor ---1.00 -------- ------Camber CamberAdj. Factor 0 Camber Required 0 Notch Depth 0.00 MATERIAL PROPERTIES Cente Uniform Live Load 24F -V4 - Visually Graded Western Species Uniform Dead Load 170 pff Base Values Rdiusted Bending Stress: Fb = 2400 psi ConW/ed b)r Fb cmpr = 1850 psi Fb' = 2400 psi Cd=1.00 Shear Stress: Fv = 265 psi FV = 265 psi Cd --1.00 Modulus of Elasticity: E = 1800 ksi E'= 1800 ksi Comp. -L to Grain: Fc -1 = 650 psi Fc -1' = 650 psi Controlling"Moment: 14288 ft -Ib 5.75 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear. -4970 lb 12.0 Ft from left support of span 2 (Center Span) Created by combining all dead loads and live bads on span(s) 2 Comparisons with required sections: Read Provided Section Modulus: 71.44 in3 132 ih3 Area (Shear): 28.13 int 66 int Moment of Inertia (deflection): 517.02 in4 792 in4 Moment: 14288 ft -Ib 26400 ft -ftp Shear: -4970 lb 11660 lb StruCalc Version 10.0.1.4 11.5 ft 5/26/2017 7:53:52 PM UNIFORM LOADS Cente Uniform Live Load 680 pff Uniform Dead Load 170 pff Beam Self Weight 14 pff Total Uniform Load 864 pff RECEIVED ► PERMIT APPLICATION CITY OF �� MAY 31 2017 PERMIT CENTER + 33325 81k, Avenue South + Federal Way, WA 98003-6325 Federal Way CITY OF FEDERAL WAY 253-835-2607 + FAX 253-835-2609 + permitcenter@cityoffederalway.com r COMMUNITY DEVELOPMENT /� PERMIT NUMBER ) _ _ ` Q lQ O �/ _ s — (.o TARGET DATE 1 SITE AD / �% �v - � SUITE/UNIT # PROJECT VALUATION $ ZONING ASSESSOR'S TAX/PARCEL # �7 TYPE OF PERMIT YBUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMMOLITION 11ENGINEERING ElFIRE PREVENTION NAME OF PROJECT B UR L A 90 V a S) U C/"E PROJECT DESCRIPTION�� t�2�/ Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER MAILING ADDRESS S! C E -MAI CITY /nn�'�,tO/�' v STATE ZIP �O� ��'`l' NAME � Yn ' , �C, v 1 / V ✓L f� V HONE /! Pd�� MAIILIINGNNG/ADDRESS S / `� /l N C ` .. CONTRACTOR CITY )QW�Y I STATE ZIP jr FAX WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # �cr�aasPHN� PRJN MoD APPLICANT- MAI DRESS E-MAIL a'r, Guypelslva CITY- iJ � STAT ZIP 9C — _,- ?' �,�L NAMNh E — &tl PRIr�Y�H��/�' PROJECT CONTACT ` lel � G ADDRESS E (The individual to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) PROJECT FINANCING NAME OWNER -FINANCED When value is $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CITY, STATE, ZIP PHONE I cert(& under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. / `� Q SIGNATURE: DATE �/!/ /2 PRINT NAME: E GA6� Al// Bulletin #100 — January 29, 2016 Page 1 of 2 k:\Handouts\Permit Application N /n (tol MECHANICAL PERMIT Indicate how many of each typ AIR HANDLING UNITS AIR CONDITIONER BOILERS COMPRESSORS DUCTING GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR - VALUE OF PLUMBING WORK PLUMBING PERMIT FOR OFFICE USE BAST+yi1v� .. a x ..., F �;� F F . . _..__._...... ............... --`-----..—.---.................. .._- .........._ $ Indicate how many o each type offixture to be installed or relocated as art o this project. Do not include existing res to remain. BATHTUBS (or Tub/Shower combo) 7 LAVS (Hand Sinks) TOILETS WATER PIPING F—DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) COVERED ENTRY DRAINS SHOWERS VACUUM BREAKERS Construction DRINKING FOUNTAINS SINKS (Kitchen/utiity) WATER HEATERS (electric) S care Feet HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR - SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS FOR OFFICE USE BAST+yi1v� .. a x ..., F �;� F F . . _..__._...... ............... --`-----..—.---.................. .._- .........._ FIRST FLOOR (or Mobile Home) EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? j /,nad-4c" ­`-�7 ❑ Yes eNo ❑ Yes ❑ No RESIDENTIAL —NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BAST+yi1v� .. a x ..., F �;� F F . . _..__._...... ............... --`-----..—.---.................. .._- .........._ FIRST FLOOR (or Mobile Home) �g p 29_ �t! rYf� �+ F - -._..._....._.__._..._....._.._....................................__..... ........................... ADDITION COVERED ENTRY AREA DESCRIPTION 120 C 2 CU Construction r .. Y 77 4 Additional Information S care Feet _...._....-.._ . ............................... _............... ............... --..... _... _........ _............ _........ ---..._.. ---- e� Stories n,.? TOEAUILAINl3 F " r GARAGE ❑ CARPORT ❑ a .__.._._._ ..... __.- ....... _._......... ___. ribe .. , �r1 -, ,r y) „ . f. Area Totals Eaasruia pROr�s ° g g f,t QQ� ESTIMATED SELLING PRICE $ / # OF BEDROOMS COMMERCIAL —NEW/ADDITION Area in AREA DESCRIPTI Occupancy Group(s) Construction # Additional Information Feet Square F TypeStoriri es RI `+£,., ADDITION COMMERCIAL — REMODEL/TE T IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information S care Feet e� Stories n,.? TOEAUILAINl3 F " r x a " „ r'. Y.., -, TENANT AREA ONLY PROJE T ' ' O�IQL ' 3 f,t Bulletin #100 -January 29, 2016 Page 2 of 2 k:\Handouts\Permit Application 44kRESUBMITTED DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF JUL 13 2017 33325 8`h Avenue South Federal Way, WA 98003 Federal Way C17Y OF FEDERAL WAY 253-835-2607; Fax 253-835-2609 C 0CY UNITY DEVELOPMEik4T www.citvoffederalway.com CALCULATING TREE UNITS This form can be used to demonstrate how you will meet the minimum tree unit requirement for your site and should accompany your submittal. Trees to be retained or planted must also be shown on your submitted site plan, or a separate tree plan. i✓ - 43,560 (sf/acre) _ 3 1 x 25 (units/acre) (lot size in square feet) (lot size in acres) (minimum tree units) Existing Trees Includes all trees except invasive species and hazard trees Tree Size (diameter at breast height /4.5') # of Trees to Remain Tree Units Total Units 1" to 6" dbh Cxoee x 1.0 = > 6" to 12" dbh x 1.5 = > 12" to 18" dbh x 2.0 = > 18" to 24" dbh x 2.5 = �l�werl' > 24" dbh x 3.0 = Total Existing Tree Units to Remain Replacement/Additional Trees Evergreen Trees — minimum 6' in height at planting Deciduous Trees — minimum 2" caliper at planting Large Canopy= 1.5 Tree Units Medium Canopy= 1 Tree Unit Small Canopy =.5 Tree Units Tree Species Canopy (Sm/Med/Lg) Tree Units # of Trees Total Units Cxoee Ma �4C4-tj 3„zo �l�werl' a r� IkeE= 1 Total Proposed Tree Units to be Added Total Existing and Proposed Tree Units jq_ Bulletin #073 — June 8, 2016 Page 1 of 1 k:\Handouts\Calculating Tree Units e to k ` Z T ) 0 — �� (i / lea 6'`' 7,4�Q / ` lip `Ga c� a �pAOO G6a o�6 poc�Dm�aio�f� �cl+ � SS o0 04 O bc> oFpAo .=�� O� - 1( �' � � % usF��°off �e �( ��, X301X I9a D&ATAI ;iFLD 50' MIN. PUBLIC RIGHT OF WAY 2x4 D.F. a 4'-0" O.G. NO. GRADE OR EQIV. 2 x2 xl4 GA. MIN. FILTER FABRIC YELDED WIRE MATERIAL MIRAFI FABRIC OR EQUAL Cz 140 BIDIM OR EQUAL. n .� u SECTION DRIVEWAY RAMP EXISTING GROUND 4"-h" QUARRY 5PALL5 PLAN PERIODIC TOP DRE551NG TO RESTORE ORIGINAL CONDITION SHALL BE DONE A5 DIRECTED BY CITY. ',� TEMP. CONSTRUCTION ENTRANCE 50ALE: NOT TO 50ALE 1 � BURY BOTTOM OF FILTER FABRIC MATERIAL ONN 8 x8 TRENCH SILT fENCE CRO55 ELE\/ATION SCALE: NOT TO 50ALE NEWLY GRADED OR DISTRIBUTED SIDE SLOPE 2"x2" STAKE FILTER FA MATERIAL 20 GUAGE WIRE TIEBACK BURY BOTTOM OF "ILTER FABRIC MATERIAL N.T.5. SILT �ENGE CRO55 SECTION SCALE: NOT TO SCALE uF U WD_' ) rE WU e� I'-ONUZOO}WU'` N50 9 Q�Ir SOdpgm 4QZN� 0'UW VZn.WNJLLa Q�wUOwd Na 00 PF Z Z¢wW WO�OOw� �� OU��aO WF�0 NC) ��Qp3$iZ�U am UiRa�Zwwxw lWi a. VW)t_jN C aO WNWSJ D¢ ZF=-NJ WU-NSA uw�J W xN_x O O~OZ<w NSwozo01-QZ w3Na000xmg¢RU" W4Sp F—W KF O ¢'L oogK0 o.zw�: t,_o_�¢¢ 6" ZONE OF QUARRY SPALL5 I' IMPERMEABLE SOIL I OR FLATTER 2 ' II "':'``•r': •; DENSE NATURAL SOILS ---SLOPE AS NECESSARY FOR STABILITY DURING H CONSTRUCTION FILTER FABRIC IF ONLY 5PALL5 ARE USED AS DRAINAGE 24" MIN' BAGKFILL FINISH GRAVEL S MLLARRTO GRADE .',! II' 84AND WSDOTDS SPECIFICATION 9-03.12 (2) 12 MIN GRAVEL BAGKF. FOR WALLS MINIMUN 6" DIA_ NULL ETFR " PERFORATED DRAIN PIPE WITH SUITABLE OUTLET ROCKERY MINIMUM PLACE ROCK ON FIRM UNDISTURBED HEIGHT (H) ROCK WIDTH (B) SOILS OR COMPACTED FILL IN FEET IN FEET < 5 1-1/2 _ 5-i 2 7-10 3 ROCKERY _ SCALE: NOT TO SCALE I\ i' i ____ __________ I \---------- SAN. SEt\ ____ _---__-_WER MANHOLE RIM=41.46 r \) 38'-O" \'''--------------_----- - IE=55.46 (8"GONG W) LADDER NW ����l��\` o \\_ --- ____ _____________ - N 8a 23 40' _. 4.78 ._ > 72 ______ ____ rr. .. .: - . w..:,... ROCKERY — _. ___ 1 X. Exl r _ STING / --- p:....NEW CONCRETE .: - ..: \X - , ' DRIVE WA / --------------- - _----- \ II'-6,1411 ♦t `:. ,PARKING PAD Y �� ----------- -- , ROCKERY / .v 4'W WALKWAY HT. CALC / r� \ wao`' — \♦ BOx \I--------- ARMORED-108'' Y / ' \ , / l A I ♦ 5, O — . V i . — /-GON5TRUGTION i ♦ 4 1-6'6 2 A O O loam ,r� li ,' ENTRANCE / GARAGE (n i l% . LOW SLAB: 104.33 \p I HIGH SLAB_104.6 f \ \\! % ,, x "'F J L- ♦ I\\ -- ,.._----------- \ \ 0 ( `\ \ o y,\ N .I . te 100 RESIDENCE �`� I LWR FLR: 95.41 98 MAIN LR: 105.5 96, I I ' - I m. i c14 44w ' TI&HTLINE DOWNSPOUTS 6 FOOTING DRAINS TO DRAIN FIELD r 411 10'x5O'xI5"d DRAIN FIELD/7/8 WASHED GRAVEL (5-4" Clio. PERF. PIPE WRAPED WITH GONST. FABRIC) \ I I -,1 �k w \\------------' ----------- 1�� / _----- x------- // // ---- / // /11/ ----------------- ----��-c-- ------=------------- ` " N 5q023'40" E ----------------330' �=- --- , a pc / i / pc i l r 'APPROVED CITY OF FEDERAL WAY PLIBLt WORKS' E ARTMENT BY DATE l SITE PLAN 0 20 40 V OWN I MFERV I OUS AREA NIKOLAY $ YELENA BURLAKOV LOT AREA: 66,0(00 5.F. CD 5II5 NE 5TH CIRCLE ROOF OVERHANG AREA: 6,254 5.F. tU RENTON, WA 1505q DRIVEWA`I'/WALKWAY AREA: 8,244 5.F. o� PHONE: (425)a4I-1153 TOTAL AREA: 14,4418 EMAIL: BDE5IGNMG@)GMAIL.COM O SITE All VRESS 21.g495 s RESUBMITTED 51511 6TH PL 5W FEDERAL WAY, WA g8025 PERMIT #: 17-102600-00-SF JUL 13 20i7 ' ADDRESS: 31811 6th Place SW PROJ� New Single Family — jFFEDER BURLAKOV OPMEYI DATE: 5/31 / 1 7 V) o v, 0 3 `0'" V W 3'� W_-3 w a6 H Z N C �v3 T �J.. 31� 3 o o In ornlm V tL-T'? In L1C0V)11 H 00 CO W InIn Lu V <Y z jLUX vQ H LU LL �¢ON > SLL. C N W Lu i� '� m LI 0 V ,LLJ O J OILI Lu Q IL V Z A � < m DESIGNED BY: DATE TG OS/O6 DRAWN BY: DATE JRA 10/24/06 PROJECT MANAGER: 5ARAH WEIGHT REVISED BY: DATE: AG 5/50/1'1 LATERAL BY: DATE: PITZER 5/15/1,7 LATERAL JOB NUMBER: 1'7-150 AO ANW WOODINVILLE OFFICE JOB NUMBER: 170068�