Loading...
17-104436Project Name: SOUTH KING FIRE & RESCUE STATION 64 Project Address: 3700 S 320TH ST Building - Commercial Permit #:17 -104436 -00 -CO Inspection Request Line: (253) 835-3050 Parcel Number: 551560 0037 Project Description: TI - Interior improvements including removal and addition of partition walls to reconfigure space; seismic retrofit and upgrades to casework & finishes. Owner Applicant City of Federal Wry FILE Community Development Dept. DAVE MATAFTINSOUTH KING 33325 8th Ave S OWNER IS LENDER Federal Way, WA 98003 FIRE AND RESCUE Ph: (253) 8352607 Fax (253) 835-2609 58.00 Project Name: SOUTH KING FIRE & RESCUE STATION 64 Project Address: 3700 S 320TH ST Building - Commercial Permit #:17 -104436 -00 -CO Inspection Request Line: (253) 835-3050 Parcel Number: 551560 0037 Project Description: TI - Interior improvements including removal and addition of partition walls to reconfigure space; seismic retrofit and upgrades to casework & finishes. Owner Applicant Contractor Lender SOUTH KING FIRE & RESCUE DAVE MATAFTINSOUTH KING OWNER IS CONTRACTOR OWNER IS LENDER 31617 IST AVE S FIRE AND RESCUE 32.00 58.00 FEDERAL WAY WA 98003 31617 IST AVE S 4,620.00 r 0.00 0.00 No Plumbing to be Included?........................................ FEDERAL WAY WA 98003 Occupancy #1 - Use ................................................ Residence (I or 2 Census Category: 437 - Commercial alt / add / conversion Includes: #1 #2 #3 #4 Occupancy Class: R-2 S-2 Construction Type: Type V- B Type V- B Occupancy Load: 32.00 58.00 Floor Area (sq. ft.) 2,155.00 4,620.00 r 0.00 0.00 Additional Permit information Occupancy #1 - Area (Sq. Feet) .............................. 2155 Occupancy #1 -Construction Type......................... Type V - B Mechanical to be Included? ..................................... Yes Plumbing Work Valuation?..................................... 85000 Mechanical Work Valuation? .................................. 10500 Number of Stories................................................... I Occupancy #2 - Class .............................................. S-2 Is this an Online or O.T.C. application?.................. No Permit for Building Shell Only? .............................. No Plumbing to be Included?........................................ Yes Occupancy #1 - Use ................................................ Residence (I or 2 Comprehensive Plan Designation........................... Office Park family) Zoning Designation ................................................. OP Total Valuation: 1,573,000.00 Ducting I Fans Em 7 Hoods 1 Drains 1 Laundry Washer Outlets 1 Lavatories 1 Showers 2 Sinks 1 Water Closets 1 PERMIT EXPIRES Sunday, 28 October, 2018 Permit Issued on Tuesday, May 1, 2018 I hereby certifythe above info on is correct and that the construction on the above described property and the Occup n r and the use a in accordance with the laws, rules and regulations of the State of Wa ington and_tbe City of Federal Way. Owner or agent: Date: �,' , �& THIS CARD IS`TO REMAIN ON-SITE °W THIS Inspection Record Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 1710443600 Address: 3700 S 320TH ST Project: SOUTH KING FIRE & RESCUE FEDERAL WAY WA 98001-3114 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as passible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On=going inspections are logged on the back of this card. 0 Plumbing Groundwork (4190)® Slab/Concrete Floor (4255) ® Underfloor Framing (4285) Approved to cover Approved to place concrete Approved to sbeath floor By Date 7, / 1 / y/ By Date. By Date 0 Initial Erosion Control (4365) 0 Footings/Setback (4110Re-steel(4215) Mechanical Roagb-m (4165) E9 Approved to install flooring To be done PRIOR to breaking ground rBy Approved to place concrete Jr By Approved to place concrete or grout By Date By 4 Date -7111 By Date 0 Plumbing Groundwork (4190)® Slab/Concrete Floor (4255) ® Underfloor Framing (4285) Approved to cover Approved to place concrete Approved to sbeath floor By Date 7, / 1 / y/ By Date. By Date 0 Floor Sheathing (4105) ® Rough Plumbing (4230) Fire/Draft Stops (4095) Mechanical Roagb-m (4165) E9 Approved to install flooring Approved rBy Approved By Date Date 10 l Z qb Approved Date C2-- © Gas Piping (4125)Q Final - S K F & R (4060) Fire/Draft Stops (4095) Approved to drop tile E9 Interim Erosion Control (4370) By Date Approved to release test Approved Approved Approved rBy Approved By At V1 Date By fil Date civ Date By Date E eda ft a Frosting Inspection; 3 Framing (4120) Insulation (4150) umbing & Med meal Rash -in Approved to insulate Approved to install wallboard Stop inspections must be dgael- d approved. IBC 1093.4 By Date By Date 16 Gypsum Wallboard Nailing(4130) © Suspended Ceiling Grid (4265) Final - S K F & R (4060) Approved to install mud &tape Approved to drop tile Approved -� By pJ Date 4 / 7 p� By Date By Date 1Aa !9 19 Final -.Planning 0 Final Erosion Control (4375) Final - Mechanical (4065) Right of Way Approved Approved [BY Approved rBy Approved By Date By - Date Date By Date .13 Final - Plumbing (4075) 2 Final - Building (4050) Approved Approved CiI*U Date ly Date t. By —g E Rough Electrical 0 F1nal.Electrical . Right of Way Approved Approved, Approved By - Date By Date - - - -By Date -S IT n-15, -TPF / +� r bac K 14- rz&40 g31Sr .J e AS ' c old<Lao wank 4� b .40)L- — IdOr- cyc HIE- -S December 18, 2018 Building Official City of Federal Way Building Department 33325 8th Avenue South Federal Way, WA 98003 Subject: South King Fire & Rescue Fire Station #64 Structural Observation Letter Permit Number: 17 -104436 -00 -CO Project Address: 3700 S. 320th St. To Whom it May Concern: Section 1704 of the International Building Code (IBC) requires that structural observation be performed. Section 202 of the IBC defines Structural Observation as The visual observation of the structural system by a registered design professional for general conformance to the approved construction documents. Structural Observation does not include or waive the responsibilityfor the inspection required by Section 108, 1705, or other sections of this code. Reid Middleton conducted site visits at various stages of construction to observe the structural components of the work at Fire Station 64. While on site we interacted with the contractor and special inspector to resolve construction -related issues. To the best of our knowledge the building has been constructed in conformance with the approved construction documents. If you have any questions please let me know. Sincerely, Reid Middleton, Inc. Corbin Hammer, P.E., S.E. Structural Principal Engineer EVERETT 128134th Street SW Suite 200 Everett, WA 98204 425 741.3800 www.reidmiddleton.com 11LIMM December 18, 2018 Building Official City of Federal Way Building Department 33325 8th Avenue South Federal Way, WA 98003 Subject: South King Fire & Rescue Fire Station #64 Structural Observation Letter Permit Number: 17 -104436 -00 -CO Project Address: 3700 S. 320th St. To Whom it May Concern: Section 1704 of the International Building Code (IBC) requires that structural observation be performed. Section 202 of the IBC defines Structural Observation as The visual observation of the structural system by a registered design professional for general conformance to the approved construction documents. Structural Observation does not include or waive the responsibilityfor the inspection required by Section 108, 1705, or other sections of this code. Reid Middleton conducted site visits at various stages of construction to observe the structural components of the work at Fire Station 64. While on site we interacted with the contractor and special inspector to resolve construction -related issues. To the best of our knowledge the building has been constructed in conformance with the approved construction documents. If you have any questions please let me know. Sincerely, Reid Middleton, Inc. Corbin Hammer, P.E., S.E. Structural Principal Engineer EVERETT 128134th Street SW Suite 200 Everett, WA 98204 425 741.3800 www.reidmiddleton.com and Cte)1"en/ f S/ON/,A-/ POWER GEN START UP REPORT BLUE FIELDS TO BE POPULATED/VERIFIED BY PROJECT MANAGER TO BE POPULATED BY Remote Contact Name Mike Hoenig Phone Cell 425-760.8366 E -Mail Load Bank Required Yes Load Bank Test Duration 2 hours Cable Access in Feet 50 Utility Present Yes Type of InstallationI Outdoor -Factory Enclosure In Service Equipment List Model / kW Spec Serial Number Voltage Phase Brand Date Customer Designation TECHNICIAN Rob Ekstrom Contact Owner's Rep AHJ Engineer rev 29 Jan 2014 Seahurst Electric Customer Name Project Name South lang FS64 Address 3700 S 320th St Federal Way, WA 98003 Project #F- 12734 - Work Order #1 349318 CNW Project Manager Brian Anderson Phone E -Mail Remote Contact Name Mike Hoenig Phone Cell 425-760.8366 E -Mail Load Bank Required Yes Load Bank Test Duration 2 hours Cable Access in Feet 50 Utility Present Yes Type of InstallationI Outdoor -Factory Enclosure In Service Equipment List Model / kW Spec Serial Number Voltage Phase Brand Date Customer Designation TECHNICIAN Rob Ekstrom Contact Owner's Rep AHJ Engineer rev 29 Jan 2014 Sates and Service GENERATOR SYSTEM TESTS BLUE FIELDS TO BE POPULATED/VERIFIED BY PROJECT MANAGER ARFFN FIF111%TO REPOPULATED BY TECHNICIAN __ Project Name_- 15ODSGAC Som+"FS64 Project #1 M 13734 11/13/18 HIS0394SIS TEST DATE 11/13/18 TECHNICIANJ Rob Ekstrom Genset Model 15ODSGAC Spec 11/13/18 M Serial Number 11/13/18 HIS0394SIS Voltage 120/208 Phase 3 Brand CPG Engine Model Q507 GS NR3 Serial Number 11/13/18 7436124► Brand 11/13/18 Cummins Fuel Type Diesel NON -RUNNING INSPECTIONS Yes Complete INSPECTIONS Tab RUNNING INSPECTIONS Not Applicable JAHu Notified and Name Recorded Yes Perform 2 HOUR FULL LOAD TEST Yes ]Record Engine and Alternator Data on Load Test Report at 15 Minute Intervals on LOAD TEST Tab Yes AR Faults Geared and Switches Placed in Auto Yes JAR Circuit Breakers Closed as Appropriate Yes JSystam Fully Operational and in Standby Mode S stem Network Not Applicable Confirm FT10/Lonworks Network Whing is Stranded Cat IV, S, 6, Belden 8471, SS102 or approved Equivalent Yes Confirm PCCNet Network Wiring is Stranded Belden 9729 or approved Equivaler Network Comments: Date Technician Notes & Comments 11/13/18 Rob Ekstrom, The unit is missing the rodent barriers in the cable way of the fuel tank. These spaces must be blocked to keep rodent damage from occurring 11/13/18 Rob Ekstrom The ATS was not provided by Cummins and will be started up by others. I have left the genset "Not In Auto" m 28 Jan 2024 GENERATOR INSPECTIONS - OUTDOOR DIESEL Project Name 15ODSGAC South King FS64 Prot M 12734 I Inspected HUMUS TEST DATE Inspected 11 13 18 TECHNICIANI Inspected Rob Ekstrom Genset Model 15ODSGAC Spec Inspected M Serial Number Inspected HUMUS Voltage Inspected 1m/208 Phase Inspected 3 Brand ATS Status Indicator(s) Functional CPG Engine Model QSB7 GS NR3 Serial Number 74361M Brand Cummins Fuel Type Diesel — A PRE -START INSPECTIONS Fuel Tank Inspected Oil level Coolant level Genet Free of Debris Anchored to Foundation Isolators Adjusted Fan Bek Pulleys Aligned Fan Bek Tension Verified Correct Battery(s) Installed Battery Charger Mourned Battery Charger Operating Coolant Heater Source Voltage Correct Coolant Heater Voltage Rating Correct Coolant Heater operating Inspected Inspected Inspected ' Inspected Inspected Inspected - Inspected Inspected Inspected Inspected Inspected Inspected inspected Muffler Installed Property Flex Installed Properly Proper Exhaust System Support Proper Piping Size Proper Rain Cap/Termination Insulation installed Condensate Drain / Trap Present Wall Thimble Present Proper Clearance to Combustibles Proper Clearance to Sprinkler Heads Inspected` Inspected inspected Inspected Not Applicable Inspected Not Applicable Inspected Not Applicable Electrical Not AppNcable All Conduits Have Flexible Connections Inspected OC Wiring Present and Correct Inspected AC Wiring Present and Correct Inspected ` Genset Grounded Inspected Neutral Bond Present Inspected Correct Voltage verified Present er Tank Installation er Fuel Lines Installed Unm Clear of Debris er Tank Vents Installed Alarm Functional wl Low Level Alarm Functional Level Alarm Functional High Level Alar Functional High Level Alar Functional rRB Prevention Valve Functional Radiator Inspected Unobstructed Intake Air Inspected Unobstructed Outlet Air Inspected Minimal Air Recirculation Enclosure Not Applicable Interior Lights Functional Not Applicable Exterior Lights Functional Not Applicable Distribution Panel Installed and Wired Not Applicable intrusion Alarm Functional Not Applicable Inlet Louvers Operational Not Applicable Outlet Louvers Operational FCC Panel Annunciator Panel Not Applicable Panel Mounted &Wired inspetud Generator Annuclator Functional Not Applicable Generator Start -Stop Functional Not Applicable Remote E -Stop Functional Not Applicable ATS Control(s) Functional Not Applicable ATS Status Indicator(s) Functional OPERATIONAL INSPECTIONS 13A Verify Static Battery Voltage 208 Verify Phase A -B Voltage 14.4 Verify Running Battery Voltage 208 Verify Phase B -C Voltage 65 Verify Proper Oil Pressure 208 Verify Phase A -C Voltage In Verify Proper Coolant Temperature 120 Verify Phase A -N Voltage Inspected Cheek for Leaks 120 Verify Phase B -N Voltage Inspected Check for Abnormal Operation 120 Verity Phase C -N Voltage Inspected Check Safety Shutdowns Verified Verify N -G Voltage is Zero — 2a j-1014 C.t= GENERATOR LOAD TEST BLUE FIELDS TO BE POPULATED/VERIFIED BY PROJECT MANAGER GREEN FIELDS TO BE POPULATED BY TECHNICIAN Project Namr_ Q04 South King FS64 Project: 12734 I 140 1 60 215 215 TEST DATE— 388 376 391 15 Min 11/13/18 TECHNICIANI Rob Ekstrom 215 215 388 Genset Model 1SODSGAC 30 Min Engine Model 140 1 0.S97 GS NR3 215 Spec M 388 Serial Number 391 74361244 4.9 Serial Number H180394515 215 Brand 215 Cummins 378 Voltage 120/208 5.1 Fuel Type 60 Diesel 215 1 215 388 Phase 3 Brandl CPG CP �° 40 o° oa P YIA 185 60 NIA 40 14.4 N 185 60 NIA 40 14.4 WA 185 80 N/A 40 14.4 N/A 185 60 N/A 40 14.4 NIA 185 60 WA 40 14.4 NIA 185 60 NIA 40 14.4 N/A 185 80 N/A 40 14.4 NIA 185 60 N/A 40 14.4 NIA 185 1 60 N/A 40 14.4 NIA Q04 START 4.1 140 1 60 215 215 1 215 388 376 391 15 Min 4.3 140 1 60 215 215 215 388 378 391 30 Min 4.6 140 1 60 215 215 215 388 378 391 45 Min 4.9 140 1 60 215 215 215 388 378 391 1 Hour 5.1 140 1 60 215 215 1 215 388 378 391 1 Hour - 15 Mine 5.3 140 1 60 215 215 215 388 378 391 1 Hour .30 Min 5.6 140 1 60 215 215 215 388 378 391 1 Hour - 45 Min 5.9 140 1 60 215 215 215 388 378 391 2 Hours 6.1 <140 1 60 215 215 215 388 378 391 CP �° 40 o° oa P YIA 185 60 NIA 40 14.4 N 185 60 NIA 40 14.4 WA 185 80 N/A 40 14.4 N/A 185 60 N/A 40 14.4 NIA 185 60 WA 40 14.4 NIA 185 60 NIA 40 14.4 N/A 185 80 N/A 40 14.4 NIA 185 60 N/A 40 14.4 NIA 185 1 60 N/A 40 14.4 NIA Fireproofing Aggregates Shotcrete C o n c r e t e December 18, 2018 Masonry A s p h a I t File No. 18-446 Roofing P i l i n g S t e e I Building Oficial S o i l s City of Federal Way Building Department W o o d 33325 80' Ave. S. Federal Way, WA 98003 Project: South King Fire & Rescue Station #64 Address: 3700 S. 320th St. Permit No.: 17 -104436 -00 -CO A.A.R. TESTING LABORATORY, INC. CONSTRICTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspections were required and copies of our inspection reports have already been forwarded to you. 1. Nelson stud welding 2. Shotcrete 3. Reinforcing concrete-CIP 4. Structural steel erection -on site welding 5. Structural steel fabrication 6. Lateral framing 7. Epoxy grouting 8. Epoxy anchor bolt installation 9. Soil bearing verification 10. In place density testing of fill material To the best of our knowledge all work inspected conformed to City of Federal Way Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Xim&er% .Anderson Kimberle Anderson President CC: Group Distribution List Tel: (425) 881-5812 Fax (425) 881-5441 • 7126 180th Ave. NE • P.O_ Box 2523 • Redmond, WA 98073 DIB Solutions Air Balance Report Project: Fire Station 64, Federal Way PRELIMINARY BALANCE System: Kitchen Hood Date: 12/17/2018 Kitchen exhaust and make-up air EF (E) 22,5041 00 Notes: Existing exhaust fan had not run in several years. Exhaust fan cleaned and belt changed. Dampers to abandoned areas of system where shut entirely I Notes: Notes: Existing exhaust fan had not run in several years. Exhaust fan cleaned and belt changed. Dampers to abandoned areas of system where shut entirely I Notes: • CITY Of Federal Way PERMIT NUMBER RECEIVED PERMIT APPLICATION PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325 SEP 14 2017 253-835-2607 + FAX 253-835-2609 + permitcenter�(icmoifederahvm coni CITY OF FEDERAL WA COMMU NT TARGET DATE SITE ADDRESS SUITE/UNIT N 3700 S 320th St, Federal Way, WA 98001 PROJECT VALUATION ZONING ASSESSOR'S TAR/PARCEL 0 $ 1,597,000 (,2y OP i5 4 1 5 6 0_ 0 0 3 7 TYPE OF PERMIT ® BUILDING PLUMBING VIMrECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT South King Fire and Rescue Facility Improvements - Fire Station 64 PROJECT DESCRIPTION Exterior Improvements: Selective demolition and reconfiguration of concrete curb, removal and replacement of existing generator, rootreplacement, newdadding on portion o rear w ing r a i ion o insu a ion and waterintruson, new c ain iinK tence an Detailed description of work to motor -operated vehicle qates and replacement of existing site lighting. Interior improvements: Selective demolition of interior building elements, new non-bearing interior walls, seismic upgrades, incidental work and improvement to mechanical, plumbing and be included on this permit only e t b S 1 v .ectrical syste , new casework and finishes, alterations required for sprinkler system shall be submitted by fire sprinkler contractor. NAME PRIMARY PHONE King County Fire District #39 - South King Fire and Rescue 253-839-6234 PROPERTY OWNER MAILING ADDRESS E. -MAIL 316171 st Ave. S CITY STATE ZIP Federal Way WA I 98003 NAME PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATEZIP FAX WA STATE CONTRACTOR'S LICENSE B EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # NAME PRIMARY PHONE Rice Fergus Miller, Inc. Attn: Ed McManamna 360-362-1427 275 5th StreING et, Suite 100 emcmanamna@rfmarch.com APPLICANT CITY STATE ZIP FAX Bremerton WA I 98337 NAME PRIMARY PHONE PROJECT CONTACT Ed McManamna Rice Fergus Miller 360-362-1427 MAILING ADDRESS 275 5th Street, Suite 100 DIEM E-MAIL emcmanamna@rfmarch.com (The individual to receive and respond to all correspondence CITY STATEIP FAX concerning this application) Bremerton WA 19Z8337 PROJECT FINANCING NAME ® OWNER -FINANCED When value is $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CITY, STATE, ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Way as to any claim (including costs, expenses, and attorneys' fees incurred in �ed the investigation a se of such cI inq, h be made by any person, including the undersigned, and filed against the city, but only where ch claim arises out of th tan of the city, including its officers and employees, upon the accuracy of the information Supp ed to the Oty as a part of th pli SIGNATURE: DATE PRINT NAME.—A_T 4 Bulletin #100 — January 29, 2016 Page 1 of 2 k:\Handouts\Permit Application VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ 105,000 Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing tures to remain. AIR HANDLING UNITS 7 FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS (Commercial BOILERS FURNACES HOT WATER TANKS (caai COMPRESSORS GAS LOG SETS REFRIGERATION SYST X DUCTING GAS PIPING WOODSTOVES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR VALUE OF PLUMBING WORK PLUMBING PERNIIT No BASEMENT $ 85,000 Indicate how man of each type of Axture to be installed or relocated as part of this project. Do not include existing tures to remain. BATHTUBS (or Tub/Shower combo) LAVS (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS X OTHER (Describe) DRAINS 2 SHOWERS VACUUM BREAKERS (1) INDUSTRIAL DRINKING FOUNTAINS � SINKS (Kimh<n/utiGry) WATER HEATERS (Electric) WASHING MACHINE HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS No BASEMENT NEW BUILDING Unknown FIRST FLOOR (or Mobile Home) EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Government Service 50,001 X Yes ❑ No ❑ Yes X No RESIDENTIAL -NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT NEW BUILDING FIRST FLOOR (or Mobile Home) ADDITION SECOND FLOOR COMMERCIAL — REMODEUTENANT IMPROVEMENTS AREA DESCRIPTION COVERED ENTRY Occupancy Groups) Construction a # of Stories Additional Information DECK 8 ,300 S -2/R-2 5B 2 GARAGE ❑ CARPORT ❑ TENANT AREA ONLY OTHER (describe) PROJECT AREA ONLY Area Totals XI ESTING PROPOSED TOTAL **NEW HOMES ONLY** ESTIMATED SELLING PRICE $ 1 # OF BEDROOMS COMMERCIAL — NEW/ADDITION AREA DESCRIPTION Area in Square Feet Occupancy Groups) Construction a # of Stories Additional Information NEW BUILDING ADDITION COMMERCIAL — REMODEUTENANT IMPROVEMENTS AREA DESCRIPTION Area in Square Feet Occupancy Groups) Construction a # of Stories Additional Information TOTAL BUILDING 8 ,300 S -2/R-2 5B 2 TENANT AREA ONLY PROJECT AREA ONLY Bulletin #100 - January 29, 2016 Page 2 of 2 k:\Handouts\Permit Application