Loading...
17-101258f ,ft w � -40 11 Building Single Family Ciy of Federal Way Permit #:17-101258-001SF FCononmity Development Dept. 33325 8th Ave S Federal Way, WA 98003 Inspection Request Line: (253) 835-3050 -, Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: NA Project Address: 3104 S 337TH ST Parcel Number: 442060 0025 Project Description: NEW - Construction of a 2,676 square foot 2 -story single family residence with a 29 square foot covered entry and a 768 square foot attached garage. Includes plumbing & mechanical. *** 3 Bedrooms; 600000 estimated selling price *** Owner Applicant Contractor Lender NAMHYO NA YOUNGYUL NA OWNER IS CONTRACTOR OWNER IS LENDER 3906 S 322ND ST 3906 S 322ND ST Basic Plan? ........................................................... No FEDERAL WAY WA 98001 FEDERAL WAY WA 98001 New / Additional Sq. Feet - Deck ........................... 0 Census Category: 101- New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: 2676 Floor Area (sq. ft.) 2,676.00 0.00 Additional Permit information New / Additional Sq. Feet - 1st Floor ..................... 1830 New / Additional Sq. Feet - 2nd Floor.................... 846 New / Additional Sq. Feet - 3rd Floor ..................... 0 Occupancy #I - Area (Sq. Feet).............................. 2676 New / Additional Sq. Feet - Basement .................... 0 Basic Plan? ........................................................... No Occupancy #I - Construction Type. ........................ Type V - B New / Additional Sq. Feet - Deck ........................... 0 New / Additional Sq. Feet - Garage ........................ 768 Mechanical to be Included?..................................... Yes Plumbing Work Valuation? ..................................... 15000 Mechanical Work Valuation?.................................. 15000 Number of Stories ................................................... 2 New / Additional Sq. Feet - Other........................... 29 Plumbing to be Included? ........................................ Yes New / Additional Sq. Feet - Total........................... 3473 Will Certificate of Occupancy be Issued? ............... Yes Occupancy #1 - Use ................................................ Residence (1 or 2 family) Comprehensive Plan Designation ........................... SF - High -Density Zoning Designation ................................................. RS 9.6 Residential Ducting 1 Fans 5 Furnaces 1 Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 3 Showers 1 Sinks 1 Water Closets 3 Water Heaters 2 Hose Bibbs 2 CONDITIONS: 1. Planning inspection required for silt fencing installation along wetland buffer per FWRC 15.10.150, split rail fencing and critical area signage required to indicate critical areas, one per residential lot. 2. Height survey required, within 2 ft. of maximum limit. 3. No clearing or grading may take place and no structures or improvements may be located in the 100 - foot Category H wetland or wetland buffer per FWRC 19.145. �� 4. Property contains a CateLyory H wetland upland from the lake (esWai rine lake wetland ner DOE). 4. Traffic impact fees required. 5. A Right -of -Way Permit is required for driveway and utility work within the public right-of-way. N ►Contact the permit desk at 253-835-2725. 0 PERMIT EXPIRES Monday,1 January, 2018 Permit Issued on Wednesday, July 5, 2017 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: City of Federal Way Certificate of Occupancy /7 This Certificate issued. pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: NA Address: 3104 S 337TH ST Permit # 17 -101258 -00 -SF Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 2,676.00 0.00 Owner Name: NAMHYO NA Owner Address: 3906 S 322ND ST FEDERAL WAY WA 98001 Building Official �Z ate The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor wan -ants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which itis situated. Such compliance is the responsibility of the owner and / or occupant of the premises. crry or Federal Way PERMIT #: 17101258 00 Project: YOUNGYUL NA THIS CARD IS TO REMAIN ON-SITE ,,yDivisionnue South Construction Inspection Record '1003-6325 INSPECTION REQUESTS: (253) 835-3050 A -5. 09 Address: 3104 S 337TH ST FEDERAL WAY WA Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 SWM Precon Site Mtg (4400) 0 Initial Erosion Control (4365) FAI Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete Ift By Date By Date YT4 _ Date nc-1 LS 117 ® Foundation Wall (4115)Q Rough Plumbing (4230) Drainagv%ownspout (4040) Approved to install roofing Plumbing Groundwork (4190) By 10S . Date 1 Z s 11 Approved to place concrete ]By By Date Appoved to backfill rBy Approved to cover By Date 1 By / a Date 1 31 By Date Wuflag a Fuming inspection; Prior to :PkAmbiog Electrical, & Medweieal Roagb- n and FireMStop motions mug be sigsed- Q Framing (4120) Approved to insulate By Date off approved. IBC 1093.4 RV N 0 Slab/Concrete Floor (4255)® Underfloor Framing (4285) ® Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date DateO �� �% By h�i Date 1y s 9t) Shear Walls (4245) El Roof Sheathing (4220) Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved By 10S . Date 1 Z s 11 By AN Date 11) 1- ) I By Date 18 Mechanical Rough -in (4165) Approved ® Gas Piping (4125) )5 pf� Approved to release test 0 Fire/Draft Stops (4095) Approved By Date By fiW Date 1/ By Date 511fa- 1BY Approved By V/ — Date By N Date G By Interim Erosion Control (4370) Approved Wuflag a Fuming inspection; Prior to :PkAmbiog Electrical, & Medweieal Roagb- n and FireMStop motions mug be sigsed- Q Framing (4120) Approved to insulate By Date off approved. IBC 1093.4 RV N Date 6—)Ir ® Insulation (4150)® F21 Gypsum Wallboard Nailing (4130) 0 Final - Planning (4070) Approved to install wallboard IS Approved to install mud & tape 1BY Approved By V/ — Date By N Date G By Date a — ® Final - Building (4050) Qf till 7 — AIJ - V(r LR CK Approved By 4IJ Date Z �' I Final Erosion Control (4375) F21 Final - Mechanical (4065) 3 Final - Plumbing (4075) Approved Approved 1BY Approved By Date By Date iB 5 By Date By Date By Date ® Final - Building (4050) Qf till 7 — AIJ - V(r LR CK Approved By 4IJ Date Z �' I Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date A ) 7 - /0) z 5 eeE �•eaee tr uw4 'u• rd1. !LlA1t MALL ISEfilY3E1'1tIR8 � FILE FRB FLOOR FRAMING PLAN m. rur,• abe n. ro a, �"iou w.n.'n.:.r`+wo •°O�`ri.°�nm a.�",.1OA n�L d..,1+•n u ry 1w a1w><o ..° bN:«Ve r�rM W,uuupLp�, LuwYnM hq am Lumbo->.deceL f.o Ca CWM OMM CMTEw13- NO2p- TAME V - NAA1ED FOORl6lGEO11.E G.Ltwl1 .R GMKIttM •C•i rY b a vwl, 0ewt0.YL.a1w > tvulw.L wcaoweelsi,w•n.ow ua wnrwa a ,w ua ttrawm a nmLttutrrw.ewtL � � �� •�nw ur •u.trwrw 4—NORTH LCL Ir I I I I I PARCEL N0. 4420600025 r I= - N 4�,T <2 f { CFZ rnVIA NA�N_f_ vi 1 rr4r t sit 3 ,f 5'a z v F P. x n Z 0 0 A 0 x r� p s� 'Y Q r C 4 7W. - . z 7 C D r z = D r,, D 3 n r r UlD Ln C m V ix n _x a o x n Z 0 0 A 0 x r� p 'Y Q C z W z z 7 C D r z = D r,, D r r UlD Ln C m v n _x a kde2ra Way PERMIT NUMBER —19 PERMIT APPLICATION PERMIT CENTER + 33325 8th Avenue South + Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + permitcenter@cityoffederalway.com -/�-) Z- �,- ��& -,S:E TARGET DATE 51� / SITE ADDRESS 3 10 5�. 337 S�- W g606 SUITE/UNIT # PROJECT VALUATION ZONING ASSESSOR'S TAX/PA EL # $ es.6 &-42dd o-0025 TYPE OF PERMIT VBUILDING PLUMBING S&EcHANicAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT 0 049"Z j�aj36:" VQ Kr ' PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE 2-6*3 zq PROPERTY OWNER MAILING ADDRESS E-MAIL CITYy STATE ZIP 7`/ 'a WA O b NAME � � � /(, _ _ ` PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE # ERPIRATION DATE FEDERAL WAY BUSINESS LICENSE # NAM PRIMARY PHONE 2 APPLICANT MAILING ADD O E -MAH. CITY STATE VV ZIP I D AR NAME - PRIMARY PHONE PROJECT CONTACT r MAILING ADDRES L I E-MAIL (The individual to receive and respond to all correspondence C STATE ZIP FAR concerning this application) Ob PROJECT FINANCING NAME OWNER -FINANCED When value is $5,000 or more (RCW 19.27.095) MAILING Ajidhws, CITY, STATE, ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: DATE —�fA r-11 U AA kil-4 PRINT NAME: I If Bulletin #100 – January 29, 2016 Page 1 of 2 k:\Handouts\Permit Application el f VALUE OF MECHANICAL MECHANICAL PERMIT —o$ Indicate how pW!I • ojfeach type o° re to be Installed or relocated as par, o`this ro ect. Do not Include existingfuctures to rernain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe), AIR CONDITIONER FIREPLACE INSERTS HOODS (commercial) BOILERS i FURNACES SHOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST I. ObdvDUCTING GAS PIPING WOODSTOVES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF PLUMBING WORK PLUMBING PERMIT Lake 6 J-e`i k Occupancy Group(s) EXISTING/PREVIOUS USE VX Ctk LOT SIZE )In Square Feet) � �� S ERISTING FIRE SPRINKLER SYSTEM? ❑ Yes �No PROPOSED FI SUPPRESSION SYSTEM? ❑ Yes ❑ No a Stories Indicate how many o each type offixture to be installed or relocated as part o this project. Do not include existing res to remain. BATHTUBS (o Tub/show rcombo) _ LAVS (Hand Sinks) TOILETS � V WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS Area in Construction DRINKING FOUNTAINS SINKS (kitchen/utwty) CPT WATER HEATERS (Electric) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS Y� - Lake 6 J-e`i k Occupancy Group(s) EXISTING/PREVIOUS USE VX Ctk LOT SIZE )In Square Feet) � �� S ERISTING FIRE SPRINKLER SYSTEM? ❑ Yes �No PROPOSED FI SUPPRESSION SYSTEM? ❑ Yes ❑ No COMMERCIAL — NEW/ADDITION Area in Cons tion # of AREA DESCRIPTION Occupancy Group(s) Additional Information Square Feet a Stories ADDITION COMMERCIAL — REMODEL/TENANT IMP MENTS Area in Construction # of AREA DESCRIPTION Oc panc GUNS) Additional Information Square Feet a Stories TOTAL, LOIN(# ,, s TENANT AREA ONLY PROJECT° AREA ONLY ,,, Bulletin #100 — January 29, 2016 Page 2 of 2 k:\Handouts\Permit Application . ..... . ......... ­­ . ....... . . ...... .... ... . ......... . ....... . .__7 ......... . 07V 040TALL VERTJC4L RESAK ALL TIE TUREAPK> RODT.500 .......... _`,_Iq .. ... ....... 7 2 R f)KPA.A, POUREM -111-V W" C . . al io M 4 f .11, 0 1,- 1A. ,,%< MAW PLAN v EW' "cp r11 z c� V_Am ec �! J . ... .... . ....... . 641%iD C?k I,V 0' &ARI -W sY 'WU_ mif�. 0., .............. . . . ...... . . ....... .. . . .......... . CINA41L IPA= Ailif OAP 2- 611AN�j,A4, i=;�L ........ . ............. ... pi AT£ TDV4R`.1 DOOR q CR"L GEAR 4w .Ail Mi, 3. 20. FILL. 11RCA.61W 1.`11m;61LpefwD IL . . ........ E� C�iie C��w . . ...... V CTION VIEW SE A MAN rc3t . ............ J, CONCRE7E RANDATICN FOOTIN�G r0ETAI at and FOOTNO DETAIL CONCRTE COLU CONCRETE FouNDA-rioN s,d. LOOP sta,ARAG15PLOOR -AVER 12- 1.1K 40ADF GAP -AGE I= M 4* CCNCWETE SLA With SCNO-TUIBE [�ETAIL a-, CS��LJJL $PACE (EXTERIOR) BEAM FOOCKET 2X MUD SILL TO HOUSE r-OWECTICNI EST B----- W�._ _�??L . . . .......... . . ..... . . .......... . . . ......... ( - y "LE W_ '. T — ( E 3f4 -01 V-11 Ee'rF DESIGN CRITERIA - (5 W) SAO< CONCRETE & - 2.sm P61 REBAR- F, 40 K& C.4p y tsm ffaF 140TES- 00 W,- 0401 -ILL UL FLWK "AP4W3 5 SAILED AW-10IR SOLT6- M"^ "- mfw%Hi N-WDN'G3+P' uw ""m ­mlis 13- . S- . VA-) ?!'MT VTWN r' OF 006 AW "N"U"t (;2 Sol -TO PER PIECE 4F VLL MAW LVV PRESSfIRE TREATED 6&L FILAT2 TABLE V - 66LATM FWTM 6CMD&E CALL= om OMAR 0AFWZMT M I I -OW e42 A w X W. 7- S FER PLAN w. W. w.Arlt Seem -m MAIN 36'. V -4 It 71-1;0"A PER p1.414 D 4'. A:-. 7- WOVIV FeR MAN of AS- . AW . S' ILEA,& PER P -,W P SA . W. W tl PER ftA11 a 4W.60'.S, 33AWZ- PEP ft,<m 2.r F_00R jais-S or" ...... ...... ... ... i n; .................. .......... VL&'2`Z BEAM 0. ---------- 2-0. PJ. 0-4 .... ....... ......... GCKCRETIE C4%,it-W FiFNS4 GRADE VFL BAM V'SWDA CIPA ON Cal -ACTED ba,; .............. k2' ------------- - -------- --- ------------ - ------ ------ -- ------ - �7----- 1 ire =w,wre r -num 'XI CCOT -------- L__ 4 ----- 7_1 ......... . ... ......... ... PECYitxl VIEW . . ....................................._.......s'j/ 20174 SHOW 0 Twoe. r-00T)Ar- -A co, w I IS1111 DAM REAM ur %is .... . .......... ... On .4 rca %1011; Sits %in 0125 %14 17 mI m1 5 331th ST FEDERAL LUAY WA VICINITY MAP 4/% \\//6 11 NA '01 / � a s�8 .z. _ 84 100'-0" BUFFER / 84' 3 I /(o -4// / q p R l to Acp Q '6 7' 0„ cn 6 ro COO c� iof 0 / lm /2 i/NR �,r-0l 3 //g „uj E & / 483 �.��� I � .5' �.to � L Rp E a - /z� R1y I c_n mo 7 35'-813/I6 " - ow RETFSZ "- �U el; lyz z WIHGARAVEL E CONBTRL�C1101 owelf 291 Uri uj NORTH LAKE 77_� Qvn�v SITS PLAN SCALE 1"=10'-0" (PLAN ON 11 x 17 IS 1" = 20'-0') IMPERVIOUS AREA 1. WALKWAY AREA = 243 SF 2. DRIVEWAY AREA = 730 SF 3 HOUSE ROOF AREA = 2988 SF TOTAL = 3962 SF TOTAL LOT SIZE =15557 SF (0.3571 AC) LOT COVERAGE MAIN FLOOR =1830 SF GARAGE = 168 SF COVERED PORCH = 61 TOTAL 2655 SF/15557 =17 6 „ w I / y m / I 6' ' / (PROPOSED) elf Lu o I / Q b. a 6',4L J0 I r W (v I Z ul 91)LL IZ WATER LINE I 52 -3 I/i6 „ / J (PROPOSED) Al NO CLEARING AND GRADING MAY TAKE PLACE AND NO STRUCTURE OR IMPROVEMENT MAY BE LOCATED IN THE CATEGORY II WETLAND OR REGULATED WETLAND BUFFER EXCEPT AS PROVIDED IN FWRC 15.10.260 AND FWRC 15.10.270 LEGEND ROOF OVERHANG LINE U o 14 1 RESUBMITTED a� ��- JUN 12 2017 CITY FEDERAL WAY COMMUNN ITY DEVELOPMENT DESIGNER YOUNGYULNA 3906 S 322nd ST FEDERAL WAY, WA 98001 ( 253 661 1229) RESIDENCE FOR YOUNGYUL $ NAMHYO NA 3906 S 322nd ST FEDERAL WAY, WA 98001 SITE ADDRESS ***** SOUTH 337TH ST. FEDERAL WAY, WA 98001 PARCEL NO.4420600025 FEDERAL WAY, WASHINGTOM 98001 YOUNGYULNA 2536611229 PARCEL NO. 4420600025 o 00 NMI o� 3 O ^Mzzco �ww c�Qo a-<� PAGE— — 21 ■ 1