Loading...
14-106080wilding - Single'Family City of Federal Way Permit #: 14- 106080- 00- S F Community &Econ. Dev. Services 33325 8th Ave S Federal Way, WA 98003 FILE Ph: (253) 835-2607 Fax: (253) 835-2609 Inspection Request Line: (2 53) 835-3050 Project Name: WYNSTONE EAST LOT 60 Project Address: 905 SW 338TH ST Parcel Number: 957850 0600 Project Description: ADD - Construction of a 160 square foot deck Census Category: 434 - Residential alttadd - no change in number of units Includes. #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load Floor Area . ft 0 1 0 1 0 1 0 Additional Permit Information New / Additional Sq. Feet - 1 st Floor .................... 0 New / Additional Sq. Feet - 2nd Floor ................... 0 New / Additional Sq. Feet - 3rd Floor....................0 New / Additional Sq. Feet - Basement .................. 0 New / Additional Sq. Feet - Deck .........................160 New / Additional Sq. Feet - Garage ....................... 0 Mechanical to be Included?...................................No New / Additional Sq. Feet - Other .......................... 0 Plumbing to be Included?......................................No New / Additional Sq. Feet - Total.......................... 160 Zoning Designation...............................................RM 3600 No Fixtures Associated With This Permit 11 PERMIT EXPIRES Wednesday, June 3, 2015 Permit Issued on Friday, December 5, 2014 hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: ?�E Owner LENNAR NORTHWEST INC A{lolicant LENNAR NORTHWEST INC Contractor LENNAR NORTHWEST INC Lender OWNER IS LENDER 33455 6TH AVE S SUITE 1-B 33455 6TH AVE S SUITE 1-B LENNANI893QG (11/7/15) FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 Census Category: 434 - Residential alttadd - no change in number of units Includes. #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load Floor Area . ft 0 1 0 1 0 1 0 Additional Permit Information New / Additional Sq. Feet - 1 st Floor .................... 0 New / Additional Sq. Feet - 2nd Floor ................... 0 New / Additional Sq. Feet - 3rd Floor....................0 New / Additional Sq. Feet - Basement .................. 0 New / Additional Sq. Feet - Deck .........................160 New / Additional Sq. Feet - Garage ....................... 0 Mechanical to be Included?...................................No New / Additional Sq. Feet - Other .......................... 0 Plumbing to be Included?......................................No New / Additional Sq. Feet - Total.......................... 160 Zoning Designation...............................................RM 3600 No Fixtures Associated With This Permit 11 PERMIT EXPIRES Wednesday, June 3, 2015 Permit Issued on Friday, December 5, 2014 hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: ?�E r CITY OF Federal Way PERMIT #: THIS CARD IS TO MAIN ON-SITEis - Construction In ection Record INSPECTION REQ TS: (253) 835-3050 14 -106080 -00 -SF Address: 905 SW 338TH ST Project: LENNAR NORTHWEST INC FEDERAL WAY, WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 SWM Precon Site Mtg (4400) 0 Initial Erosion Control (4 65) 0 Footings/Setback (4110) By Date Approved By PAL Date t To be done prior to breaking ground By Approved to place concrete By Date By Date By Date Gypsum Wallboard Nailing (4130) Foundation Wall (4115) Final - Building (4050) Drainage/Downspout (4040) Approved Slab/Concrete Floor (4255) By Date Approved to place concrete By PAL Date t Approved to backfill By Approved to place concrete By Date By Date By Date Underfloor Framing (4285) 0 Floor Sheathing (4105)Shear Walls (4245) Approved to sheath floor Approved to install flooring Approved to install siding By Date By Date By Date Fire/Draft Stops (4095)Interim 0 Roof Sheathing (4220) Erosion Control (4370) Approved to install roofing Approved Approved By Date By Date By Date Framing (4120) Insulation (4150) o scheduling a Framing inspection; Plumbing & Mechanical Rough -in and EFire/Draft Approved to insulate Approved to install wallboard Stop inspections most be signed off and IBC 109.3.4 By PQ -y Date By Pte-- Date .. z� , t approved. Gypsum Wallboard Nailing (4130) Final Erosion Control (4375) Final - Building (4050) Approved to install mud & tape Approved Approved By Date By Date By PAL Date t D Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date CONSULTING ENGINEERS PACIFIC NORTHWEST ENGINEERING INC. January 27, 2015 #14-1159 Lennar Northwest, Inc Attn: Brian Christensen 33455 6' Ave S; Unit 1B Federal Way, WA 98003 Subject: Modified Rear Deck (Correction Notice) Plan Number: 2845-A Site: Wynstone Lot #60 905 SW 338' St Federal Way, WA 98023 Mr. Christensen, Pacific Northwest Engineering Inc. (PNE) as requested has reviewed correction notice provided by the City of Federal Way for the deck dated 1/23/15 for permit number 14- 106080. We have responded to the comments in an itemized format as noted in the correction notice: 1. We have reviewed the modified deck size to be 6' x 20' and preformed a structural analysis on the framed members. a. The deck framing shall be 2x8 joists at 16" o.c. spanning from the home to a beam line approximately 66"from the home. b. The beam line consists of 4x8 HF#2 or better with supports set 24" from the end and 8' apart, (3) total supports. c. Supports shall be 4x4 posts with 18" diameter x 6" deep pad footings with (1) #4 each way for reinforcing. d. Lateral restraint DTBZ anchors shall be provided per the original submitted detailing although they are not required structurally. 2. Bottom of stair stringers connection are adequate to be notched and bear on a treated 2x4 sill anchored to the foundation. (2) %2" diameter anchor bolts shall be supplied as a minimum. 3. Nails shall be added to fill holes in hangers 4. A35 shall be attached the side of each stringer and to the single joist. 5. Treatment of posts is required where exposed or in contact with surrounding soils. Cedar posts are acceptable as a natural resistance to decay_ Pacific Northwest Engineering Inc. 1944 Pacific Ave; Ste 310 Tacoma, WA 98402 Phone (253) 682-2850 Fax (253) 682-2851 K v SPEWED . i CITY OF NOV 2 4 2014 PERMIT APPLICATION Federal Way CIT`( OF FEDERAL WAY CDS PERMIT NUMBER TARGET DATE SITE ADDRESS SUITE/UNIT # 905 SW 338th St PROJECT VALUATION ZONING ASSESSOR'S TAR/PARCEL # $ 185,020.00 RS7.2 _ _ _ _ 957850 _ 0600 TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Wynstone East Build deck PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER Lennar NW Inc. 253-590-2208 MAILING ADDRESS E-MAIL 33455 6th Ave South, Unit 1 B norena.edgecombe@lennar.com CITY STATE ZIP Federal Way WA 98003 NAME PHONE Lennar NW Inc. 253-590-2208 MAILING ADDRESS E-MAIL CONTRACTOR 33455 6th Ave South, Unit 1 B norena.edgecombe@lennar.com CITY STATE ZIP FAX Federal Way WA 98003 WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # LENNAN1893QG 11/7/2015 20 -13 -100182 -00 -BL NAME PRIMARY PHONE Lennar NW Inc. 253-590-2208 APPLICANT MAILING ADDRESS 33455 6th Ave South, Unit 1 B E-MAIL norena.edgecombe@lennar.com CITY STATE ZIP FAX Federal Way WA 98003 NAME PRIMARY PHONE PROJECT CONTACT Norena Edgecombe 253-590-2208 MAILING ADDRESS 33455 6th Ave South, Unit 1B EMAIL norena.edgecombe@lennar.com (The individual to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) Federal Way WA 98003 PROJECT FINANCING NAME N/A - Owner Financed OWNER -FINANCED Required value of $5,000 or more MAILING ADDRESS, CITY, STATE, ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. �i SIGNATURE:AbtzDATE PRINT NAME: NOren dgecombe Bulletin #100 — January 1, 2013 Page 1 of 3 k:\Handouts\Permit Application VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existin fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS commeroiai) BOILERS FURNACES HOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR VALUE OF PLUMBING WORK PLUMBING PERMIT None Lakehaven Lakehaven None EXISTING/PREVIOUS USE LOT SIZE IIn Square Feat) $ Indicate how many of each type o fixture to be installed or relocated as part of this project. Do not include existingfixtures to remain. BATHTUBS(or Tub/ shower Combo LAVS Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS xitohon/uwity WATER HEATERS (Eteot w) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS None Lakehaven Lakehaven None EXISTING/PREVIOUS USE LOT SIZE IIn Square Feat) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? None ❑ Yes d No ❑ Yes [a' No Bulletin #100 —January 1, 2013 Page 2 of 3 k: llandoutsTermit Application