Loading...
14-106477• Building - Single Family City of Federal Way FILE Community &Econ. Dev. Services Permit #: 14-106477-00-SfC 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2807 Fax: (253) 835-2809 Inspection Request Line: (2 53) 835-3050 Project Name: TWIN ADULT FA HLY HOME Project Address: 32335 29TH AVE SW Parcel Number: 8731901290 Project Description: ALT - Verification of Occupancy for Adult Family Home. ***No construction work allowed under this permit.*** Owner Ap lits cant Contractor Lender SAMUEL SOH DOSOON SOH DOSOON SOH TWIN ADULT FAMILY HOME 1.416 BEDSTONE DR SE 1416 BEDSTONE DR SE , 31 OLYMPIA WA 98513 OLYMPIA WA 98513 Ic Census Category: 434 - Residential alt/add - i New / Additional Sq. Feet 3rd Fl ... 1 Mechanical to be Included? .................. I�prmation 14ew / Additional Sq. Feet - Basement. ..... ...0 Plumbing to be Included?.. ......... ..........No This Permit ll FRES Saturday, June 20, 2015 on Monday, December 22, 2014 Obn is correct and that the construction on the above described property and accordance with the laws, rules and regulations of the State of Washington and the City of 54eral Way. Date: ( Z t 2- Z " 1 THIS CARD IS TO REMAIN ON-SITE CITY OF Construction Inspection Record' Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 14 -106477 -00 -SF Address: 32335 29TH AVE SW Project: SAMUEL SOH FEDERAL WAY, WA 98023-2512 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. Final - Building (4 50) Approved By Date Rough Electrical Approved 1:1Approved Final Electrical 1:1Approved Right of Way By Date By Date By Date ` Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) &4,7,7APPLICATION NUMBER: O SECTIONS 1, 2, 3. AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION WILL BE PROCESSED SECTIONPROPERTY"•' • 3 z 3 3S �a�-q f GI �' .v]rz S' i�7 973 / qv SITE ADDRESS: T (Ld�Vax qw A- D ASSESSOR'S TAX/PARCEL#:___l_?___Q_C?_ _ SECTIONA' •' • PROPERTY OWNER NAME: �O') r Sa.I,4f u� 0C S C7©_^�_ DAYTIME PHONE: C-"-,�> 3 26 —3 60 2 AFH LICENSEE NAME (IF DIFFERENT): S7 C;, L, V S 0 a—hq— DAYTIME PHONE: C -,_S;-3/ aq `r'' SECTION 3 - FLOOR PLAN On a separate sheet of paper (8 1/2x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms (bedrooms) indicating which bedroom is: A, B, C D, E and F. Label all components for exiting i.e., stairs, ramps, platforms, lifts and elevators. SECTIONBLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home at this location. I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any person, including the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application. NAME/TITLE: DATE: f Z/ 2Z I ZU PROPERTY OWNER APPLICANT LICENSEE11 ,NZ Effective: 2013 July 01 Updated: 2013 June c• A325.8.3 Grab bars at water closets. Water closets shall have grab bars mounted on both sides. Grab bars can be a combination of fixed position and swing -up bars. Grab bars shall meet the requirements of R325.8. Grab bars shall mount between 33 inches and 36 inches above floor grade. Centerline distance between grab bars, regardless of type used, shall be between 25 inches minimum and 30 inches maximum. R325.8.3.1 Fixed position grab bars. Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from the rear wall. R325.8.3.2 Swing -up grab bars. Swing -up grab bars shall be a minimum of 28 inches in length from the rear wall R325.8.4 Grab bars at bathtubs. Horizontal and vertical grab bars shall meet the requirements of R325.8. R325.8.4.1 Vertical grab bars. Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and head end wall. Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub. The bottom end of the bar shall start between 36 inches and 42 inches above floor grade. EXCEPTION: The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting the requirements of R325.8 at the control end and head end entry points. R325.8.4.2 Horizontal grab bars. Horizontal grab bars shall be provided at the control end, head end, and the back wall within the bathtub area. Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Control end and head end grab bars shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. R325.8.5 Grab bars at shower stalls. Where shower stalls are provided to meet the requirements for bathing facilities, grab bars shall meet the requirements of R325.8. EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab bars at the seat end wall. A vertical floor to ceiling gra b bar shall be installed within 4 inches of the exterior of the shower aligned with the nose of the built-in seat. R325.8.5.1 Vertical grab bars. Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and head end wall. Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. R325.8.5.2 Horizontal grab bars. Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 inches and 38 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls. Horizontal grab bars shall not interfere with shower control valves. R325.9 Ramps. All interior and exterior ramps, when provided, shall be constructed in accordance with Section R311.8 with a maximum slope of 1 vertical to 12 horizontal. The exception to R311.8.1 is not allowed for adult family homes. Handrails shall be installed in accordance with R325.9.1. R325.9.1 Handrails for ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with R311.6.3.1 through R311.6.3.3. R325.10 Stair treads and risers. Stair treads and risers shall be constructed in accordance with R311.7.4. Handrails shall be installed in accordance with R325.10.1. R325.10.1 Handrails for treads and risers. Handrails shall be installed on both sides of treads and risers numbering from one riser to multiple risers. Handrails shall be installed in accordance with R311.7.7 through R311.7.7.4. R325.11 Shower stalls. Where provided to meet the requirements for bathing facilities, the minimum size of shower stalls for an adult family home shall be 30 inches deep by 48 inches long. [Statutory Authority: RCW 19.27.031 and chapters 19_27 and 34_05 RCW. 13-04-068, § 51-51-0325, filed 2/1/13, effective 7/1/13. Statutory Authority: Chapter 19_27 RCW. 10-18-036, § 51-51-0325, filed 8/25/10, effective 9/25/10. Statutory Authority: RCW 19.27.190, 19.27.020, and chapters 19_27 and 34_05 RCW. 09-04-023, § 51-51-0325, filed 1/27/09, effective 7/1/10. Statutory Authority: RCW 19.27.074, 19.27.020, and chapters 19_27 and 34_05 RCW. 07-01-090, § 51-51-0325, filed 12/19/06, effective 7/1/07. Statutory Authority: RCW 19.27.031 and 19.27.074. 04- 01-109, § 51-51-0325, filed 12/17/03, effective 7/1/04.] Effective: 2013 July 01 Updated: 2013 June 1i GENERAL YES NO, Bathroom doors are easily and quickly openable from the outside when locked ❑ ❑ Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. ❑ ❑ Smoke alarms are installed on all levels of the dwelling, in each resident sleeping room, outside each separate area in the immediate vicinity of sleeping rooms (8314). ❑ 13sleeping Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all parts of the dwelling upon activation of a single device. ❑ ❑ Access road and water supply meet local fire jurisdictional requirements. ❑ ❑ R325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (lever -type). ❑ ❑ Pocket doors shall have graspable hardware available when in the closed or open position. ❑ ❑ R311.8 Ramps YES NO Inside Ramp N/A ❑ ❑ ❑ R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in AFH) R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes directions. ❑ ❑ R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1— R311.8.3.3. ❑ n 1171 Outside Ramp I N/A ❑ 1 YES NO R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in AFH) ❑ ❑ R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes directions. ❑ ❑ R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1— R311.8.3.3. ❑ ❑ Guards below are depicted vertically as an example only. All Ramps must have Guards ❑ 1 ❑ --, =- Less than 4" l — , - I Guard 36' Imin l j 11 3' x landing landing minimum - Handrail both sides 34" - 38" l el I ! 3' landing landing — One unit vertical in twelve units horizontal r—a 3' --i is an 8.3% slope all along surface of the ramp. minimum 8311.2 Means of Egress YES NO R311.2 Door must be side -hinged with min. width of 32 inches between face of door and stop. Height not less than 78 inches. R325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (lever -type). ❑ ❑ R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry without use of key, tool or special knowledge. Required exit door shall have no additional locking devices. 13 ❑ R311.7 Stairways N/A ❑ 1 YES NO R311.7.4.1 Riser Height: Max riser height shall be 7 Y4 inches (8 inches in structures built prior to July 1, 2004) n 1171 R311.7.4.2 Tread Depth: Min. tread depth shall be in 10 inches (9 inches in structures built prior to July 1, 2004) ❑ ❑ R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple risers. Handrails shall be installed in accordance with R311.7.7.1— R311.7.7.4 0 ❑ Effective: 2013 July 01 updated: 2013 June Flwr Plan Nt✓ /idK I f Fc-w <cf Itovoe KS- Upstairs Emergency Plan F. r Aci " I FO- Vu ; ( y 4 owv \A s t Row Plan .�L�<<<r �n�-n� �se� Down Stairs Emergency Plan C Nlf fW � d � (�- F"(( "°''v)v- ""e) `C1W OF Federal Way r r Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: �iZ3�.)/ Z�L'�� A1�. °S� PERMIT#: t�-'db l77 -Va a Nl_ til IF YOU HAVE QUESTIONS CALL pt (253) 835- � WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRE TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE j Page ` of CITY OF 4A Federal Way COMMUNITY DEVELOPMENT SERVICES 253-835-2607• FAX 253-835-2609 tuwo:.rj[yo_rl {qay cp?r *PERMIT MF CO ME PL DE EN FP APPLICATION 330 DEC 2 2 2014 SITE ADDRESSDERAL WAY 3z - s 2. "fil Avv- Sw F d%ew,( mat, t WA q1 Dz3 ?-Y-1 2- PROJECT VALUATION $ ZONING I���d - ASSESSOR'S TAX/PARCEL # 1 r 3 z� o_� z o o TYPE OF PERMIT X BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT (Tenant Name/Homeowner Last Name) r , t> c),5> N 50M. PROJECT DESCRIPTION Detailed description of work to t W -h(, i -� � o(V 4 V W- N be included on this permit only PROPERTY OWNER NAME S -ri PRIMARY PHONE C Z5-3) a b-3 60 MAILING ADDRESS tag k-rm+eDr. S E-MAIL sc�o soft l CITYSTATE vC W ,' a W ZIP �M 3 NAME PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # NAME a o tj 9 d PHONE C 7-�73� APPLICANT MAELING ADDRESS ('o E-MAIL ��� CITY ( (/ 1. WI L Ol STATE W b-- ZIP g / 61 FAX PROJECT CONTACT (The individual to receive and respond to all correspondence concerning this application) NAME p PHONE Cz.-r3> 3 MAILING ADDRESS P" S & E-MAIL ntosv v-71:30 k Wl ai CITY p-t tM rx STATE W- ei rl 3 FAX ALTERNATE ONTACT NAME: cr I (-) NE E237-6-360Z- E-MAIL PROJECTFINANCING NAME 0 OWNER -FINANCED Required value of $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CITY. STATE, ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: -� �� � DATE_ZT Z� 1 � { PRINT NAME: h es) 1 y Bulletin #100 - April 14, 2010 Page 1 of 3 k:\Handouts\Permit Application ,ccnM �c