Loading...
14-105922Mechanical City of Federal way Permit #: 14-105922-00-ME. Community&Econ. Dev. Services 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 FILE Inspection Request Line: 253 835-3050 Project Name: LOUDENBACK Project Address: 2710 SW 344TH PL Project Description: Remove and replace 40k.gas furnace Parcel Number: 5029451260 Owner ARI21ican Contractor AARON C LOUDENBACK NORTHWEST PERMIT/ WESCO PACIFIC AIR SYSTEMS (GENERAL) CAROLE R LOUNENBACK 1345 W GULF RD PACIFAS093KA (9/8/15) 2710 SW 344TH PL POINT ROBERTS WA 98281 12811 PACIFIC HWY SW FEDERAL WAY WA LAKEWOOD WA 98499 98023-3061 PERMIT EXPIRES Wednesday, May'I Permit Issued on Friday, November 14, I hereby certify that the above information is correct and that the the occupancy and the use will be in accordance with 4kejpwsg and the City Owner or agent: property and Nashington f • � w 1 CITY OF Federal Way THIS CARD IS TO REMAIN ON-SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 14 -105922 -00 -ME Address: 2710 SW 344TH PL Project: AARON C LOUDENBACK FEDERAL WAY, WA 98023-3061 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD, Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Mechanical Rough -in (4165) 0 Gas Piping (4125) ❑ Final - Mechanical (4065) 1:1Approved Approved By Approved to release test Approved By Date By Date By Date Rough Electrical Approved 1:1Approved Final Electrical 1:1Approved Right of Way -� By Date By Date By Date C1* OF Building Division 33325 Eighth Avenue South Federal Way, 98835-6325 Federal Way Phone 253-835-2607 Faxax 253-835-2609 CORRECTION NOTICE ADDRESS: 2710 SW 344th Pl. PERMIT#: 14 -105922 -00 -ME IMC 603.9 Joints, seams and connections. All longitudinal and transverse joints, seams and connections in metallic and nonmetallic ducts shall be constructed as specified in SMACNA HVAC Duct Construction Standards—Metal and Flexible and NAIMA Fibrous Glass Duct Construction Standards All joints longitudinal and transverse seams and connections in ductwork shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric systems liquid sealants or tapes. Seal connection between duct work and furnace. IF YOU HAVE QUESTIONS CALL Matt (253) 835 2623 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 12/5/14 Matt Date Inspector DO NOT REMOVE THIS NOTICE Page 1 of 2