Loading...
14-100726Sign 6ity of Federal Way /� Community & Econ. Dev. Services Permit #: 14 -100726 -00 -SG 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 FI., !E Inspection Request Line: (253) 835-3050 Project Name: TWIN LAKES SHOPPING CENTER Project Address: 2311 SW 336TH ST Parcel Number: 873217 0040 Project Description: Relocation of existing internally -illuminated 96 sqft monument sign as part of ROW widening project. To attach to existing J -box. Owner Applicant Contractor TWIN LAKES SHOPS LLC C/O SUHRCO SIGN -TECH ELECTRIC LLC SIGN -TECH ELECTRIC LLC MANAGEMENT INC 5113 PACIFIC HWY E SUITE 12 SIGNTEL988BG (1/7/16) C/O SUHRCO MANAGEMENT INC FIFE WA 98424 5113 PACIFIC HWY E SUITE 12 2010 156TH AVE NE SUITE 100 2 FIFE WA 98424 BELLEVUE WA 98007 6.00 10.00 Free Standing Sign Information Reg. # Sign Type Illuminated # Sign Faces Setback (Ft.) Sign Face Width (Ft.) Sign Face Height (Ft.) Sign Height (Ft.) Base Height (Ft.) Landscape Area (Sq Ft.) na Monument Yes 2 3.00 7.75 6.00 10.00 4.00 109.00 Additional Permit Information Comprehensive Plan Designation..........................Neighborhood Zoning Designation ................................................ BN Business PERMIT EXPIRES Tuesday, December 30, 2014 Permit Issued on Thursday, July 3, 2014 I hereby certify that the above information is correct and th the con uction on the above described property and the occupancy and the use will be in accordance witlx fhe�s, rul and regulations of the State of Washington and the ON of edec ay. Owner or agent: Date: CITY OF A& ' Federal Way PERMIT #: Project: THIS CARD IS TO REMAIN ON-SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 14 -100726 -00 -SG Address: 2311 SW 336TH ST TWIN LAKES SHOPS LLC C/O M FEDERAL WAY, WA 98023-3823 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. Attachment (4010) Approved By Date ❑ Footings/Setback (4110) ❑ Final - Electrical (4055) Final Electrical Approved Final - Sign (4085) Approved to place concrete By Approved Approved By VxA6 DateI 'kil By Date By Date Attachment (4010) Approved By Date ❑ Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date 14 0 0 7 ?0 S FEB 14 2014 CITY OF �GN PERMIT 3 Federa FEDERAL A To CDs APPLICATION SITE ADDRESS4311 lL i r �`� I ] SUITE /UNIT # ASSESSOR'S TAX/PARCEL # v - O O O ZONING DESIGNATION PROJECT INFORMATION TYPE OF PROJECT (Check all that apply): ❑ NEW k ALTERATION ❑ REFACE ❑ EXEMPT e ELECTRICAL (To attach to existing J -box - include on this permit) ❑ ELECTRICAL (New/altered circuit & J -box added - separate permit is required) NUMBER OF SIGNS APPLIED FOR WITH ��TH��IyS**yyAr�PPLICATION: Wall Mounted: Freestanding: TOTAL ESTIMATED PROJECT COST: $'4� DETAILED PROJECT DESCRIPTION: \ e OCAnok lV1 C),j �-d o'vvt lO BUSINESS NAME ON SIGN: SIGN OWNER: CONTRACTOR: APPLICANT PROJECT CONTACT NAME: ISA. �( J �' 1� � ► I 1 �C. PRIMARY PHONE MAILING ADDRESS (STREET ADDRESS; ITY. STA , Z ): k"' 9800'�s FAX NUMBER 3 ) b s�- - CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: I E-MAIL ADDRESS COMPANY NAMEAPPLICANT NAME PRIMARY PHONE OFFICE PHONE k ,c - mAiLiNG ADDRESS c ) -aHto mAiLING ADDRESS TRE ET DRESS: CITY, STATE, ZIP): RELATIONSHIP TO PROJECT E-MAIL ADDRESS CELL PHONE SII Cijo- CITY OFF DERAL WAY BUSINESS LICENSE NUMBER: EXPIRATION DATE: FAX NUMBER 1 - qq -10 - -cc -31-- I'�--3i-Iq c - CONTRACTOR'S NUMBER: EXPIRATION DATE: E-MAIL ADDRESS (REGISTRATION \ L ' - / - i A COMPANY NAME APPLICANT NAME PRIMARY PHONE -F-- C - mAiLiNG ADDRESS CITY, STATE, ZIP FAX NUMBER l � - RELATIONSHIP TO PROJECT E-MAIL ADDRESS ❑ Contractor ❑ Tenant ❑ Other N,�,�Q�M'��E PRIMARY PHONE E-MAIL ADDRESS: '[ 9'n�nnv�..� /Illc 1011 �)�%, _,414%O QI,.L.'.><a,.,.,.la.l„ o(onLnlr_ I certify under penalty of per ury that the information furnished by me is true and correct to the best of my knowledge, and further, that I autho a by the owner of the above premises to perform the work for which the permit application is made SIGNATURE DATE:Vv- COMMUNITY DEVELOPMENT SERVICES - 33325 8T1 AVENUE SOUTH - FEDERAL WAY, WA 98003-6325 - 253-835-2607 - FAX: 253-835-2609 JR' OTHER PERMANENT BUILDING MOUNTED: AWNING CABINET CHANNEL LETTERS TENANT DIRECTORY OTHER (Describe) FREE STANDING SIGNS MOUNTED SIGNS SIGN TYPE SIGN AREA (SQ. FT.) ILLUMINATED? REFACE? TOTAL HEIGHT BASE HEIGHT (FT) REGISTRATION NUMBER: REGISTRATION NUMBER: WIDTH x HEIGHT x # OF FACES NO / INT / EXT YES / NO FT A A �;� x IUB x B B x x — x x — C C x x — x x — STREET FRONTAGE (LINEAR FEET): BUILDING MOUNTED SIGNS BUILDING MOUNTED SIGNS SIGN TYPE SIGN AREA (SQ. FT.) ILLUMINATED? BUILDING ELEVATION EXPOSED BUILDING FACE REGISTRATION NUMBER: REGISTRATION NUMBER: WIDTH x HEIGHT x# OF FACES NO/INT/EXT N S E W S. FT. A x x — B x x — C x x — D x x — E x x — LARGEST EXPOSED BUILDING FACE (SQUARE FEET): **FOR OFFICE USE ONLY** ZONING DESIGNATION: PROFILE: ❑ HIGH ❑ MEDIUM ❑ LOW ❑ FREEWAY BUILDING MOUNTED SIGNS FREE STANDING SIGN(S) AREA PERMITTED: AREA PROPOSED: LARGEST BUILDING FACADE: NUMBER OF SIGNS ALLOWED: AREA PERMITTED: AREA PROPOSED: STREET FRONTAGE: NUMBER OF SIGNS ALLOWED: LAND USE APPROVAL BY: DATE: STRUCTURAL APPROVAL BY: DATE: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: Bulletin #102—January 1, 2011 Page 2 of 4 k:/Handouts/Sign permit Application U SIGN PERMIT APPLICATION CHECKLIST APPLICATIONS WILL NOTBE ACCEPTED AT THE COUNTER UNLESS ALL REQUIRED INFORMATION IS PROVIDED ❑ COMPLETED PERMIT APPLICATION ❑ APPLICATION FEES ❑ TWO (2) COMPLETE SETS OF PLANS (ASSEMBLED AND STAPLED INTO SETS) ❑ MINIMUM PLAN SIZE— 11"X 17" ❑ PLANS DRAWN TO SCALE AND SCALE PROVIDED ❑ SITE PLAN: ❑ Scale (1" = 20') ❑ ❑ North arrow ❑ E Property lines and building footprint ❑ ❑ Location of suite, if multi -tenant ❑ ❑ ELEVATION DRAWINGS ❑ Scale (1/8" = 1') ❑ Location and size of all signage including: ❑ Existing signs to be removed ❑ Existing signs to remain on each facade ❑ Proposed signs ❑ Dimensions of each building face or suit Bade ❑ Calculated total building face area ❑ Calculated total sign face area OR Calculated total area of individual signage components (letters,.n6mbers, logos, etc.) ❑ Each proposed sign alpha labeled consistent with application Location of ALL proposed signs, including refaces Each sign alpha labeled consistent with application Location of all existing signs to remain Location of all existing signs to be removed ❑ DETAILS ❑ Scale ❑ Sign materials, color and illumination type ❑ Actual weight of sign or individual letters ❑ Cross-section showing scaled width of sign: if canopy or awning, show entire building including awning/canopy and color scheme ❑ Method of attachment, size/type of connector AND ❑ Site-specific installation details (what sign is attached to in field), placement and construction ❑ Each proposed sign alpha labeled consistent with application ❑ SITE/ LANDSCAPING PLAN © ELEVATION DRAWINGS (IN ADDITION TO OVERALL SITE PLAN) ❑ Scale ❑ Minimum scale 1" = 20' ❑ Sign materials, color & illumination type El Footprint and dimensions of sign CpSign face/panel/base dimensions ❑ Setbacks from property line(s) / j ❑ Calculated total sign/panel area D Show point of measurement for location of� ❑ Base materials & how harmonious w/building property line(s) using fog -line, sidewalk, �� and/or edge of ❑ Foundation type Alpha labeling ❑ pavement �,�� Show location of driveway and street ❑ consistent with application ❑ Footprint and dimensions of landscape area CROSS-SECTION ❑ Type & location of landscape vegetation ❑ Scale ❑ Calculated landscape area �� ❑ Edge of landscaping area (minus footprint of sign) �,� ❑ Existing & finished grades surrounding sign DETAILS ❑ Total sign height from average grade ❑ Foundation/footing information ❑ Wind load calculations (for signs 6' & over) Bulletin #102—January 1, 2011 Page 3 of 4 k:/Handouts/Sign Permit Application DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8`h Avenue South Federal Way, WA 98003-6325 CITY OF 253-835-2607; Fax 253-835-2609 Federal Way www.cityoffederalway.com JUN 0 9 2fl14 Ci"('Y OF FEDERAL WAY RESUBMITTAL INFORMATION This completed form MUST accompany all resubmittals. **Please note: Additional or revised plans or documents for an active project will not be accepted unless accompanied by this completed form. Mailed resubmittals that do not include this form or that do not contain the correct number of copies will be returned or discarded. You are encouraged to submit all items in person and to contact the Permit Counter prior to submitting if you are not sure about the number of copies required. ** ANY CHANGES TO DRAW/NGS MUST BE CLOUDED. Project Number: - 7 - C' Q - Project Name: lkiiot (akes c5 Dpi Crit+er— Project Address: -rh Projeci Contact: kAR- �QhA13EP, Phone: 053-922- dl'l(o RESUBMITTED ITEMS: i. # of Copies ** Detailed Description of Item 3 �1 i i s "ov►S a4J t fur lt►�5 cis , � FK „mer App ( tA)I tip M Sfire,-t ex t ' A 5 I Q Iti . ladL6k4&'_ 3 &A ;+� �ziofi W i �.l ccs (Cti "" Always submit the same number of copies as required for your initial application." Resubmittal Requested by: Letter Dated: to em er OFF/CE USE ONL Y RESUB #. Distribution Date: By.- Dept/Div Name # Description Building Planning PW Fire Other -0"Al Bulletin #129—.Ianuary 1, 2011 Page I of I k:\Handouts\Resubmittal Information TTED RESU BMI , DEPARTMENT OF COMMUV[TY DEVELOPMENT SERVICES 33325 8'h Avenue South CITY OF � APR U 3 2014 Federal Way, WA 98003-6325 253-835-2607; Fax 253-835-2609 Federal Way CITY OF FEDERAL WAY www.citvoffederalway.com CDS RESUBMITTAL INFORMATION This completed form MUS T accompany all resubmittals. **Please note: Additional or revised plans or documents for an active project will not be accepted unless accompanied by this completed form. Mailed resubmittals that do not include this form or that do not contain the correct number of copies will be returned or discarded. You are encouraged to submit all items in person and to contact the Permit Counter prior to submitting ifyou are not sure about the number of copies required. ** ANYCHANGES TO DRAW/NGS MUST BE CLOUDED. Project Number: Project Name: Project Address: 2-311 SW 33&,"" Project Contact: t A4"/zdIle-7 Phone: 2S-3 RESUBMITTED ITEMS: # of Copies Detailed Description of Item Dept/Div -Name G^ftii• �zu,,��s' S L��lr��s Gr/is� Buildin o e-�t� c2 ae AI owf7 '-Z /So Planning PW Fire Other " Always submit the same number of copies as required for your initial application.'" Resubmittal Requested by: Letter Dated: Member) RESUB ,# OFFICE USE ONL Distribution Date. G� By. 1 Dept/Div -Name # Description Buildin o u) y Planning PW Fire Other Bulletin "129 — January I, 2011 Page I of I V Handouts\Resubmittal Infonnation From: Sent: To: Cc: Subject: Attachments: Good afternoon Rich, PermitCenter Thursday, March 20, 2014 3:14 PM 'rich@signtechelectric.com' Scott Sproul Twin Lakes Shopping Center sign 129 Resubmittal Information.doc I've completed my initial review of the sign permit materials you submitted on 2/14/14. The following items need clarification and subsequently, submittal of drawings, in order for me to complete the review: Site/Landscaping Plan • Plans should be drawn to a minimum scale of 1" = 20' • Setback from property line(s), including the point of measurement for location of property line(s) using fog -line, sidewalk, and/or edge of pavement. • Footprint and dimensions of landscape area (FWRC 19.140.170(5)) • Type & location of landscape vegetation • Calculated landscape area (minus the footprint of the sign) • Footprint and dimensions of sign Elevation Drawin • Base materials & how harmonious w/building(s) on-site (FWRC 19.140.170(3)(c)) Please submit 2 copies of the requested materials along with the attached Resubmittal form. If you wish to, you may submit the foundation and wind load information along with these items. They will be routed to the appropriate staff. The application review is on -hold until these items are received. Please let me know if you have any questions, my contact information is noted below. Thank you. K.4. c " cpr Permit Center Supervisor 33325 8`h Avenue S Federal Way, WA 98003-6325 Ph: 253-835-2607 Fx:253-835-2609 !2ermitcenter@cityoffederalway.co iA Please consider the environment before printing this email March 27, 2014 Sign -Tech Electric LLC 5113 Pacific Hwy E, Suite 12 Fife, WA 98424 Re: File #14 -100726 -000 -00 -SG; TWIN LAKES SHOPPING CENTER 2311 SW 336`h Street, Federal Way Dear Applicant: I am unable to complete the plan review of the above -referenced project until I receive additional information regarding, but not limited to, the following: Original Comment 1. Provide wind load calculation for the sign. The calculation shall detail the steel post and footings are sized correctly. 2. Provide complete attachment details for sign frame to steel pipe; none have been provided. New Comment 1. The resubmitted drawings did not provide wind load calculation and attachment details. The submitted calculation shall be stamped and signed by a Washington State Licensed Engineer. 2. Please specify the minimum concrete thickness under the steel column. The plans depict it supported by the ground. The purpose of this plan review is to verify code compliance, to the extent possible and reasonable, given the information provided on the plans and the city's plan review resources and capabilities. In no way does any city approval constitute a guarantee of code compliance; authorize any work in violation of any applicable codes; or relieve the owner of responsibility for complying with pertinent codes and ordinances. Provide two sets of the corrected drawings, and complete the enclosed resubmittal form. Plans requiring engineering must be stamped by the engineer and be accompanied by the engineer's calculations. I will review the resubmittal as expediently as possible. Further corrections may be necessary as a result of submitting additional information. If you have any questions, please call me at 253-835-2633. Sincerely, Scott Sproul Assistant Building Official enc: Resubmittal Information Form 14-100726 Doc. I.D. 65294 _ --dam- . ,. . .:- .«�� -a A WIND LOAD CALCULATION 1= I I I WIND LOAD = 33 PSF (110 MPH WIND) Q' SOIL - FINE SAND -SOFT CLAY 1.5 KIPS PSF SUPPORT = SCHEDULE 40 STEEL 6" PIPE z ��y'Syy*f�y��e6'�y3gP 80SF X 33PSF =2640 FORCE 2640 FORCE X 5 =13,200 c w �4daadE 13,200 / 3 FOUNDATION LENGTH = 4400 4400 / 144 = 30.5 ?iaadt€) 3FL X 3FD = 9 9 / 30.5 = 3.5 FOUNDATION SHOULD BE 3' wide X 3'deep X 3.5'tal I MW■:u w � I Q I I I I i i SITE MAP • y W Is - E a.. SITZ` P P + i A. 2311 SW 336th St Federal Wbiy,. VIV, 198023 n - a M 3, V, RESUBMITTED JUN 0.9 2014 '�"I rOCITY OF FEDERAL WAY L CDS `�'`c�;--.� �3 A --------- ----- ----------------- - ------------- ------------------ ---- --- ----------- ------ ---- -0 m n ) A- X 0, --i 011 :03 J _1v - qI 3' 7< (D 01 V, RESUBMITTED JUN 0.9 2014 '�"I rOCITY OF FEDERAL WAY L CDS `�'`c�;--.� �3 A --------- ----- ----------------- - ------------- ------------------ ---- --- ----------- ------ ---- -0 m n ) X 0, --i u :03 qI 3' 7< (D 01 m :3 cn L0 0-0 &) :3 mac) FD (D n m 1-y"VIN LAKES SHOPPING CENTER SCALE: 1/2 .1 8; 71 C-�" 4.. 4-13\ weld attaichmen-11. 13 /-A ICZ STEEL 0MA-r 3'-0 O �o m 0 FE 27 CfVBlET PA 10 3/4" C) o OVERHEAD VIEW OF �r-, i'! ET "ONSTRUCTION IN �- � -If S.OG 0 t i n tc. EXISTING MONUMENT SIGN CABINET: QQL I Rl E Sl QFQ EXTRUDED ALUMINUM FACES. PC)'L'--C_,ARBONATE 1 CXOPY MIULT"FENANT PAH ELS lLLUN';,lNATl,0N- HC"D rl---1-U0RESCENT 13"1 LAMPS -a , ILK 3'-0 SKIRTING: .040 STEEL SHEET METAL TEXTURE PAI NTED TO MATO H BUILDING � --%- ---, iY RESUBMITTED JUN 0 9 2014 CITY OF FEDERAL WAY CDS --------------- --------------- SIGN DES(."'RIPTION SCALE: 1/9 =1 Lu cc 2s, , kr� -4 &V, 336th - -- — - ----------- -------3_0 1 - ----- "D 0- Sign PlacernentA. -ey 3 foo' sc:--t batck hn By J m JUN 0 9 2014 Ay ro� 1%io ---------------------------------- CL CL ------- --------- ---------- - -------- ---------- -------------------------- -------- ------------- ----------- ....... ------------------- --------- ---------------------- S ITE. Irlil A T, 2 1 N' R.. 3E W M. �.,a.i-w.li A� tel-•• i" ".* � '�.tili'} 1'. iV Et. 15s ly: E {f { V., T-3Z6.ETH i An f U. La LL t� ;12 4 T N IRAINAGE: CONSTRUCTIOw! W EMCM W, P', PC- A,�AXI C, R � MIA! tA�% 0 K C"-r%iJ C -MM A STWw4 UPX-- P'' is *JOOR 0, CoNs-mcmON Nams. GENERA- NOTES., VMMWNI� 4m -m P.M io 45 x.17, 'U:NA" W� Cql'i owatuld M EK -11 UALL i)n 94M, CxLVlk4 WX;;w1p , M") v'fiinui. rwo Am &r"MFuv.Tf*- CUM "0 kagvtr-r- UVAVIK", kv 4XIMMOS M"I10", 109t 14 �FMV-Cte t7teMr"i.l. MTAU cw R. N'v 4w iF`�Fmut��7t.:--Zs* P&STALL rW. VvsW smL�r! I'm RIC mwo., lj IOWTAIL tCJW'fiA:,-Y CQ*v'fFP,:.LjWR oex, miGa. mo RESP u lzwkw To piwhEa wAm MISTALL NVW A& AX -5 F'l BMITTED M, ma, r 41 siv5-4 CAF nz ?z-rtr-cr,-. aw" 111W. A" OARV C* FW* Vo VNIAO-1 4;wvl AkL Fl*SwWl csT vvf. 7. aqmti. W,'O PAW L, PLATM M It 3UN M V He om E"ll In e-WIku —1 e L Z C-1 1 09-2114 CIA i t� A. C"" WAy IL MH 14ftw w4ln TLL. Fed" DRAINAGE PLA14 way ------------------------- ---------------- ------------------ -- ---------------- -------------------------- ------------------- ---------------- ------------------------- --------- ----------------------------------- -------------- — ------- -------------- ----------------------------------------------- - ------ ---------------- ..-------- _ _------------------------� � I { ICc ; a gn ;v ed �'H t h 3, lo v U v n P�!t zt, I - { s Xf I y ( { f ! { tj� --�F, I -- _ 1 _ mu _ oo Lu set DIr tt'`-a2'' �' S3 tax 4YdFsu��. ( �l f { F¢ #1 c Fg k' i`r tl. 11111 i t�orl y IjI �r�}I i��°'4i} bm"s< Sr�e y f f III { I i xfif w �F r4$r.a1 iSi w�yik's {in , A SIGN FOOT T,Ccom>- ! l `4�� ( 2 3 i �. : fau"`• C'y 0,.4" A �'^1 j py {-- 1 ,,,, BTRAC I l Oa laid y ...s . c _ r f �..__-�W civ- � �/Q „' �-���• "' " �-� , ' �.1 L -i - � y CPA pa fm If uj RESUBMITTED JUN 0 9 2014 S � CT i # � y OF FEDERAL WAY 3 �.� a # �c)t z � a- �> k CDS : }� I s, i i - i r ♦ , 3 I D O OAD CALCULATION SCALE: 1/2 0 8' I nk r i E I { E - F I WEND LOAD = 33 PSF (110 MPH WEND) SOIL - FINE SAND -SOFT CLAY 1.5 KIPS PSF SUPPORT = SCHEDULE 40 STEEL 6" PIPE 80SF X 33PSF =2040 FORCE 2440 FORCE X 5 =13,200 13,200 i 3 FOUNDATION LENGTH = 4400 4400 i 144 _k :�>0_5, 3FLX3FD=9 9!30.5=3.5 FOU NDA ON SH OUL D BE 3'vAde X 3'deep X 3.5'taii y, n' I 1 RESUBMITTED i 1161 f JUN 0 9 2014 CITY OF FEDERAL WAY CDS LLL.