18-105797City of Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax (253) 8352609 Project Name: DANIEL Project Address: 34213 11TH AVE SW Electrical Permit #:18 -105797 -00 -EL Inspection Request Line: (253) 835-3050 Project Description: Installation of 7.08 kW photovoltaic solar rooftop system. Parcel Number: 957850 0090 Owner Applicant Contractor MICHAEL DANIEL HEIDI PASCHALSMART ENERGY TODAY SMART ENERGY TODAY 34213 11TH AVE SW 1001 COOPER POINT RD SW SMARTET869RJ (12/18/18) FEDERAL WAY WA 98023 OLYMPIA WA 98502 1001 COOPER POINT RD SW OLYMPIA WA 98502 Additional Permit Information Is this an Online or O.T.C. application? .................. No Circuits - Residential PERMIT EXPIRES Saturday, 14 December, 2019 Permit Issued on Friday, December 14, 2018 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or a - Date: ) 2- l q- 1 LZ s nom; THIS CARD IS TO REMAIN ON-SITE Orv°r Construction Inspection Record FLacWf al Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 1810579700 Address: 3421311TH AVE SW Project: MICHAEL B DANIEL FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the lack of this card. 0 UFER Ground (4295) ® 0 Ditch cover (4030) Service (4235) Slab/Concrete Floor (4255) Approved Approved Approved Approved By Approved to place concrete By Date By By Date By Date 0 Pool Bonding (4195) ® Temporary Power (4275) © Service (4235) Approved EBy Approved Approved By Date Date By Date 0 Feeders/Sub-panels (4045) ® Rough Electrical (4225) 1 Ceiling Cover (4020) Approved IBY Approved Approved By Date Date By Date Fol Final - Eleetrical (4055) Approved By Date 13 Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date CITY OF Federal Way RECEIVED DEG 10 2018 CF Y C1= Fc -:0E AL WAY COMMI NMI D`L`.`24.0PMENT AAzl(fd � ! i-aG--(8 ELECTRICAL PERMIT APPLICATION `PERMIT NUMBER I V - I C) 5-1 cl-7 - 6t-- I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such clai"g, which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: -A� �° ""rt ""' — PATE 11/27/2018 PRINT NAME: Heidi Paschal PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + permitcenter(u'cityoffederalway.com Bulletin #160 - April 14, 2016 Page 1 of 1 k:\Handouts\Electrical Permit Application SUITE/UNIT/SPACE M SITE ADDRESS: 34213 11th Ave SW, Federal Way PROJECT VALUATION ASSESSOR'S TAX/PARCEL N CURRENT/PROPOSED USE 3,500 9 5 7 8 5 0 _ 0 0 9 0 PROJECT NAME (Tenant or Homeowner Last Name) Michael Daniel Installation of PV Solar Rooftop System 7.08kW PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER Michael Daniel ( 206 601 -6218 MAILING ADDRESS E-MAIL 34213 11th Ave SW bigdog.md06(i,gmail.com CITY STATEZIP FAX Federal Way WA 98023 ( ) - NAME PRIMARY PHONE Smart Energy Today ( 360 637 - 4343 x 2226 MAILING ADDRESS E-MAIL ELECTRICAL 1001 Cooper Point Rd SW heidi.pi;smartenergytoday.net CITY STATE ZIP FAX CONTRACTOR Federal Way WA 98502 ( _ WA STATE CONTRACTOR'S LICENSE M EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE R SMARTET869RJ 1 10/2019 20 -15 -101145 -00 -BL NAME PRIMARY PHONE APPLICANT Heidi Paschal ( 360 ) 637 - 4343 x 2226 MAILING ADDRESS 1001 Cooper Point Rd SW E-MAIL heidi.p asmartenergytoday.net CITY STATE ZIP FAX Olympia WA 98502 ( - NAME PRIMARY PHONE PROJECT CONTACT Heidi Paschal ( 360 637_ 4343 x 2226 I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such clai"g, which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: -A� �° ""rt ""' — PATE 11/27/2018 PRINT NAME: Heidi Paschal PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + permitcenter(u'cityoffederalway.com Bulletin #160 - April 14, 2016 Page 1 of 1 k:\Handouts\Electrical Permit Application (N) Roof Mounted PV Array 24 x Itek IT295-SE Modules / 00 x Solaredge P320 Optimizers EMT Conduit Run on Roof (Z"-32" Above Rooftop), Under Eaves Where Possible, Down Exterior Wall 3 U) W W � I u � i I I I r I I i I I , Driveway I D------------ SID INV PM ACD UM SITE PLAN SCALE: 3/32" = 1' -- (E) Utility Meter (E) Main Service Panel (Inside) (N) Customer Generation AC Disconnect (Outside) LEGEND (N) Solar Production Meter (E) EXISTING (Outside) (N) --- NEW WIRING METHOD AP FIRE ACCESS POINT (N) Solaredge SE760OH-US Je JUNCTION BOX PV String Inverter with Disconnect UTILITY METER (Outside) nnsP MAIN SERVICE PANEL pM PRODUCTION METER nc� AC DISCONNECT wv INVERTER Sr wl energy today® SOLAR 1 1001 COOPER POINT RD SW, STE 140-290, OLYMPIA, WA 98502 PHONE: 360-637-4343 HEIDI PASCHAL PROJECT MANAGER 7.080 DC KW 7.000 KW CEC-AC RATING CENTRAL INVERTER SYSTEM 18, 270' TILT AZIMUTH 34213 1 1 TH AVE. SW FEDERAL WAY, WA 98023 MICHAEL DANIEL (206) 601-6218 APN:9578500090 DATE I DESCRIPTION UM « 11/27/18 DRAWN: DRAWN BY: I PD SITE PLAN A 00 2 Ig- A5 797