13-104176City of Federal Way Community & Econ. Dev. Services 33325 8th Ave S Sign Permit #: 13 -104176 -00 -SG Federal Way, WA 98003 RPh: (253) 835-2607 Fax: (253) 835-2609 �.; Inspection Request Line: (253) 835-3050 Project Name: METRO PCS Project Address: 31007 PACIFIC HWY S Unit C Parcel Number: 082104 9061 Project Description: Install (2) internally -illuminated channel letter wall mounted signs. Includes electrical connections to existing Xboxes Owner Applicant Contractor ROBERT TJOSSEM SIGNS PLUS INC (GENERAL) SIGNS PLUS INC (GENERAL) PO BOX 614 1330 N FOREST ST SIGNSPI952LW (6/16/15) BOTHELL WA 98041 BELLINGHAM WA 98225 1330 N FOREST ST BELLINGHAM WA 98225 Additional Permit Information Comprehensive Plan Designation .......................... Community Zoning Designation ................................................ BC Business PERMIT EXPIRES Saturday, April 12, 2014 Permit Issued on Monday, October 14, 2013 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use wild be in accords ce with the laws, rules and regulations of the State of Washington and t City of Federal Way. Owner or agent: Date: /C'z" tI CITY OF Federal Way PERMIT #: THIS CARD IS TO REMAIN ON-SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 13 -104176 -00 -SG Address: 31007 PACIFIC HWY S Unit C Project: ROBERT TJOSSEM FEDERAL WAY, WA 98003 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. Attachment (4010) Approved By Date Footings/Setback (4110)Final - Electrical (4055) Final Electrical Approved Final - Sign (4085) Approved to place concrete By Approved Approved By Date By Date By Date Attachment (4010) Approved By Date Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date RECEIVED , SIGN PERMIT f=ederal Way SEP 2 0 20APPLICATION SITE ADDRESS , —1007 pA C i f iC } 1 WY (3_ 101176 oa SUITE/UNIT # ASSESSOR'S TAX/PARCEL # O 8 a I o A.t - I d b i— ZONING DESIGNATION TYPE OF PROJECT (Check all that apply): (ANEW ❑ ALTERATION ❑ REFACE ❑ EXEMPT ALECTRICAL (To attach to existing J -box - include on this permit) ❑ ELECTRICAL (New/altered circuit & J -box added - separate permit is required) NUMBER OF SIGNS APPLIED FOR WITH THIS APPLICATION: Wall Mounted: Freestanding: O Oo TOTAL ESTIMATED PROJECT COST: $ :57C000 " DETAILED PROJECT DESCRIPTION: JJ ;j'TA LL. — T�tl.3c> C Ili r_N h V N c -t_ BUSINESS NAME ON SIGN: M C- f10 f C J SIGN OWNER: CONTRACTOR: APPLICANT NAME: I `ol. rT ao Pe—S PRIMARY PHONE (2+4) d -3833 MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): FAX NUMBER 3 100 -7pp _ i F i C- 6.>" 1..,4 gblbO ( ) - CITY OF FEDERAL WAY BUSINESS LICENSE MBER: E-MAIL ADDRESS COMPANY NAME APPLICANT NAME OFFICE PHONE w rh — S A 8 0 v 15( ,516 NS PLJS K K E 10-fgalx.44 (3 66 ) 671 -7/0 MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): CELL PHONE E-MAIL ADDRESS %66 A1 ke- Dlzl ✓� /`3ELl,lNG(� Awl ,�,A je2a (3,60)�3�r -72 I!r CITY OF FEDERAL WAY BUSINESS LICENSt NUMBER: EXPIRATION DATE: FAX NUMBER P'ff JDI�_< (No ) 671 - 01Q CONTRACTORS REGISTRATION NUMBER: EXPIRATION DATE: E-MAIL ADDRESS 1G / q c,w �►, i.�.LpJ( COMPANY NAME APPLICANT NAME PRIMARY PHONE w rh — S A 8 0 v 15( ) - MAILING ADDRESS CITY, STATE, ZIP FAX NUMBER RELATIONSHIP TO PROJECT E-MAIL ADDRESS !elc, ontractor ❑ Tenant ❑ Other PROJECT NAME CONTACT �mwa I r✓L �Ii �%� I certify under penalty of perjury that the further, that I am authorized by the own o > e P PRIMARY PHONE E-MAIL ADDRESS: IcP i��s c36� -7195 NtIk&,A%cIU159 by me i rue and correct to the best of my knowledge, and top orm the work for which the permit application is made DATE: COMMUNITY DEVELOPMENT SERVICES • 33325 8' AVENUE SOUTH • FEDERAL WAY, WA 98003-6325 • 253-835-2607 • FAX: 253-835-2609 PERMANENT FREE STANDING: MONUMENT PEDESTAL POLE TENANT DIRECTORY OTHER OTHER (Describe) PERMANENT BUILDING MOUNTED: AWNING CABINET CHANNEL LETTERS TENANT DIRECTORY OTHER fDescribel FREE STANDING SIGNS MOUNTED SIGNS SIGN TYPE SIGN AREA (SQ. FT.) WIDTH x HEIGHT x # OF FACES ILLUMINATED? NO / INT / EXT REFACE? YES / NO TOTAL HEIGHT FT BASE HEIGHT (FT) A WIDTH x HEIGHT x # OF FACES NO/INT/EXT N,S,E,W B —11C x x = A GuA►.,v'lA-- t S`1 19 -T STREET FRONTAGE (LINEAR FEET): BUILDING MOUNTED SIGNS SIGN TYPE SIGN AREA (SQ. FT.) ILLUMINATED? BUILDING ELEVATION EXPOSED BUILDING FACE WIDTH x HEIGHT x # OF FACES NO/INT/EXT N,S,E,W (SQ- FT. A GuA►.,v'lA-- t S`1 19 -T -7q2 x'/=3% = B CNA>,WJ - , s. ,. 7 S p �,E - x�!-3 x�= 7a�S C x x - D x x = E _ x x = LARGEST EXPOSED BUILDING FACE (SQUARE FEET): 7D�• 5 0• * r** PROFILE: ❑ HIGH ❑ MEDIUM ❑ LOW ❑ FREEWAY IOUNTED SIGN(S) I FREE STANDING SIGN(S) 7• % — 51.94 *+ DATE: ,.:PTKATION NUMBER: REGISTRATION NUMBER: I_\4:7uIto94 G AREA PROPOSED: STREET FRONTAGE: NUMBER OF SIGNS ALLOWED: STRUCTURAL APPROVAL BY: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: DATE: Bulletin #102 - January 1, 2011 Page 2 of 4 k:/Handouts/Sign Permit Application If SIGN PERMIT APPLICATION CHECKLIST APPLICATIONS WILL NOTBE ACCEPTED AT THE COUNTER UNLESS ALL REQUIRED INFORMATION IS PROVIDED, ❑ COMPLETED PERMIT APPLICATION , / \ ❑ APPLICATION FEES n �`� ❑ TWO (2) COMPLETE SETS OF PLANS (ASSEMBLED AND STAPLED INTO SETS) V" ❑ MINIMUM PLAN SIZE — 11" X 17" ❑ PLANS DRAWN TO SCALE AND SCALE PROVIDED ❑ SITE PLAN: ❑ Scale (1" = 20') ❑ Location of ALL proposed signs, including refaces ❑ North arrow ❑ Each sign alpha labeled consistent with application ❑ Property lines and building footprint ❑ Location of all existing signs to remain ❑ Location of suite, if multi -tenant ❑ Location of all existing signs to be removed ❑ ELEVATION DRAWINGS (o kale ('ys" = 1') -Z Location and size of all signage including: ❑ Existing signs to be removed ❑ Existing signs to remain on each faSade Proposed signs Z/Dimensions of each building face or suite fagade r5 Calculated total building face area q"Calculated total sign face area OR Calculated total area of individual signage components (letters, numbers, logos, etc.) ❑ Each proposed sign alpha labeled consistent with application ❑ SITE/ LANDSCAPING PLAN (IN ADDITION TO OVERALL SITE PLAN) ❑ Minimum scale 1" = 20' ❑ Footprint and dimensions of sign [.l Setbacks from property line(s) ❑ Show point of measurement for location of property line(s) using fog -line, sidewalk, and/or edge of pavement ❑ Show location of driveway and stree ❑ Footprint and dimensions of Ian cape area ❑ Type & location of landscape vegetation ❑ Calculated landscape area (minus footprin of sign) ❑ DETAIL ❑ Fou ation/footing information ❑ Wind load calculations (for signs 6' & over) u DETAILS O�Scale cSign materials, color and illumination type ,6" Actual weight of sign or individual letters Cross-section showing scaled width of sign: if canopy or awning, show entire building including awning/canopy and color scheme n Method of attachment, size/type of connector AND p,,' Site-specific installation details (what sign is attached to in field), placement and construction Li Each proposed sign alpha labeled consistent with application ❑ ELEVATION DRAWINGS ❑ Scale �= ❑ Sign materials, .& illumination type ❑ Sign face/panel/base dimensions ❑ culated total sign/panel area ❑ Base materials & how harmonious w/building ❑ Foundation type ❑ Alpha labeling consistent with application ❑ CROSS-SECTION ❑ Scale ❑ Edge of landscaping area ❑ Existing & finished grades surrounding sign ❑ Total sign height from average grade Bulletin #102 — January 1, 2011 Page 3 of 4 k:/Handouts/Sign Permit Application CITY OF Federal Way RESUBMITTED DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES SEP 2 5 2013 33325 8`h Avenue South Federal Way, WA 98003-6325 CITY OF FEDERAL WAY 253-835-2607; Fax 253-835-2609 CDS www.cityoffederalway.com RESUBMITTAL INFORMATION This completed form MUST accompany all resubmittals. "Pleasenote: Additional or revised plans or documents for an active project will not be accepted unless accompanied by this completed form. Mailed resubmittals that do not include this form or that do not contain the correct number of copies will be returned or discarded. You are encouraged to submit all items in person and to contact the Permit Counter prior to submitting if you are not sure about the number of copies required. "" ANYCHANGES TO DRAW/NGS MUST BE CLOUDED. Project Number: Project Name - Lt i Project Address: 3too7 PA,1.tf_1 Project Contact: MiKe I ra-2gl Pl; k.�tL Phone: tomo- - (� 1- 71 RESUBMITTED ITEMS: # of Copies ** Detailed Description of Item l �t6CJ t7�"r4} ** Always submit the same number of copies as required for your initial application." Resubmittal Requested by: f_z=0 - Al, �_7 Letter Dated: / .Zo / 1`c'f.3 (Start mem r OFFICE USE ONL Y RESUB A' Distribution Date: By. Dept/Div Name # Description Building Planning PW Fire Other Bulletin 4129 —January 1, 2011 Page 1 of 1 k:\liandouts\Resubmittal Information `Federal Way r Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: 3% dog Pac.if; c. t-11NH S. V►,;+ C -PERMIT#: 13 64- 1 -7 1, - oo - Sc, . I l W IA C. -2A 1. - 4 to g- 0 l b G► e,, -e, C, k, c, i� v i C G� 1 W k v i v., jl� $ w 1'j Ayc(Ul iNG 5 $ I vi Vw� I v►Se- N IV1SpC-CA -Ior,.4-o u 11 V<_j a. H o,(low i►^Spec,+oy 47cViStre I,I I IVtS10e- wwve K04TAOVA p6LgeS 4- I Ks 4-1, (( &+i o h -67/" N t,G 0-J A l ey V ' rL YK hC o f � t c, - 4- . C o VL+ a c-4--&+'t-�(' V e- �Ld 5, -- t I � S Tc- t- , - , , - - o h S 14-c 47' i %o e-c4iovi at Lr 005't S - 2.Pa�,c t of Gi �`1 P (av% ✓&Vl'ew Ayc(Ul iNG 5 $ I vi Vw� I v►Se- N I S ►/G u 11 V<_j a. H WA,VJ wwve K04TAOVA p6LgeS 4- eAkd aa19vVve- c( p (CKs a' -e +�L5 . IF YOU HAVE QUESTIONS CALL V"`-U� (253) 835- -2-(-23 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. !0 2-3 113 DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of - iv;awy 'T Kent Woodmont Beach II a Aubua Federal Way` -vt_SF:T 11, T Oona It l•IirSso Cor partipr VICINITY MAP I I 88.1' PROPERTY LINE I LU I I J• I �I I of I I I I I � JOB SITE Q I METRO PCS I I 31007 PACIFIC HIGHWAY PARCEL # 01 I I = 1 0821049061 LL I I I UI i ----- ---------1 i a I I :I I PLACE PROPOSED NEW SIGN #1 HERE I I I I I I I I PLACE PROPOSED NEW SIGN #2 HERE I I I I I I I SITE MAP SCALE: 1 /32"=1 '-0" Sign attachment inspection required. RECEIVED SEP 2 0 2013 CITY OF FEDERAL WAY CDS (!!P) SIGNS PLUS 1330 N. Forest St. Bellingham, WA 98225 Phone 360.671.7165 Fax 360.671.0144 signsplusnw.com METRO PCS 31007 PACIFIC HIGHWAY FEDERAL WAY, WA 98003 CLIENT: ADVANCED WIRELESS FOLDER NAME: SHARED\PROJECTS\METRO PCS\ (03) FED-03\SITE MAP.CDR DATE: 9/6/2013 SCALE: AS NOTED SALES EXECUTIVE: ENTER NAME DESIGNER: MIKE LINEBRINK FINAL SALES DATE PRODUCTION DATE REVISION DATE REVISION DATE JOB # 99843 ®?m?Sgns Plaa I Thisar—kisd:` Underwriters property ofSigns Plus aad is protected each s— and fedoal copyright lawn � � Laborat -•--'-- My— fth:: ut 1, aher than die IISIE ba:imsa.mth Sugar:-ts.athoat wntte permission :hall conatiwte yoar 0 pur ,,,— agreement to chase this artswh, and the design proposed per M, � 0 I..n l� O LT5 Copyright Law T,& 17/92Chap-5 M L_ 70 M INTERNATIONAL SIGN M M SERVICE NOTES LAMPS: z.n co co 3 O Q0 O V 0. - w 0 � TRANSFORM ERS/BALLASTS: cD Q --1 cn (D -* O OTHER: CO n EAST ELEVATION SIrONO SOUTH ELEVATION 17 GkA -42- '5A T7 SIGNS PLUS mao.a,oa_..oataae the no,. 1330 N. Forest St. Bellingham, WA 98225 Phone 360.671.7165 Fax 360.671.0144 signsplusnw.com METRO PCS 31007 PACIFIC HIGHWAY FEDERAL WAY, WA 98003 CLIENT: ADVANCED WIRELESS FOLDER NAME: SHARED\PROJECTS\METRO PCS\ (03) FED-03\ELEVATIONS.CDR DATE: 9/6/2013 SCALE: 1/16"=I' -O" SALES EXECUTIVE: ENTER NAME DESIGNER: MIKE LINEBRINK FINAL SALES DATE PRODUCTION DATE REVISION DATE REVISION DATE JOB # 99843 02012 Thisart.vark Underwriters .. -d O property of Signs Pias.nd is protened ,rnygraiv. under ane end fed—I-pyright I.— ® Laboratories Inc.© Any am of thisa A eth<r than direr tistEo badne.a th signs—U,i thwt 1 t to purchase Jsis nnwork, A, L,—. end,6 design proposed per Vs Copynght I .Tde n/9'-' Ch.prer S INTERNATIONAL SIGN ASSOCIATION SERVICE NOTES LAMPS: TRANS FORMERS/BALLASTS: OTHER: T ptlk'l EAST ELEVATION FoOF= 4qS 0 7 WS;dSOUTH ELEVATION ew= (!-- T.—J> SIGNS PLUS 1330 N. Forest St. Bellingham, WA 98225 Phone 360.671.7165 Fax 360.671.0144 signsplusnw.com METRO PCS 31007 PACIFIC HIGHWAY FEDERAL WAY, WA 98003 CLIENT: ADVANCED WIRELESS FOLDER NAME: SHARED\PROJECTS\METRO PCS\ (03) FED-03\ELEVATIONS.CDR DATE: 9/6/2013 SCALE: 1/8"=1'-0" SALES EXECUTIVE: ENTER NAME DESIGNER: MIKE LINEBRINK FINAL SALES DATE PRODUCTION DATE REVISION DATE REVISION DATE JOB # 99843 PI... Underwriters UL Pro dyds,.. -I" Pros under—."hdeolcopyrightlaws. Laboratories Inc.. Any"ae "f1hie an Anther than d— M1u�nru wilM1 Sign. Plus without wrinen Permiuion.hall connituie your � .g.ammn. Purchase thn anwork. and thedr.igu pmp-d Per US Copyright Ia Title 17192 Chapte. 5, INTERNATIONAL SIGN ASSOCIATION SERVICE NOTES LAMPS: TRANSFORMERS/BALLASTS: RESUBMITTED OTHER: SEP 25 2013 CITY OF FEDERAL WAY C? N r cn - 17'-1" - 16'-51/2" • AM 1 0 , Ift 13 SQ. FT. 10'-71 /4„ - Illuminated Channel Letters On Raceway/ Tagline Cabinet - 30" Tall "PCS„ INDIVIDUAL LIGHTED CHANNEL LETTERS/ TAGLINE CABINET - RACEWAY 1/2" = 1'-0" SCOPE OF WORK: MANUFACTURE, SHIP & INSTALL ONE (1) SET OF INTERNALLY ILLUMINATED PLEX FACED CHANNEL LETTERS & TAGLINE CABINET. ALUMINUM CHANNEL LETTERS TO HAVE WHITE RETURNS AND TRIMCAP W/ #2447 WHITE ACRYLIC FACES W/ VINYL APPLIED TO FIRST SURFACE. "METRO" TO HAVE ARLON 5590-5412 PURPLE PERFORATED VINYL (DAY(NIGHT) APPLIED. "PCS" TO HAVE ARLON 5590-3411 ORANGE PERFORATED VINYL (DAY/NIGHT) APPLIED. ALUMINUM TAGLINE CABINET TO HAVE WHITE FILLER & RETAINERS. FACES TO BE WHITE ACRYLIC W/ #2500-3411 ORANGE VINYL APPLIED TO FIRST SURFACE. LETTERS & CABINET TO BE INTERNALLY ILLUMINATED W/ SLOAN VL PLUS WHITE SHORT L.E.D.'S. LETTERS & CABINET ARE MOUNTED TO RACEWAYS, PAINTED TO MATCH COLOR OF BLDG. METRO PCS LETTERS HAVE A WHITE 1/8° THICK ALUMINUM BACKGROUND PANEL MOUNTED BETWEEN THE LETTERS AND THE RACEWAY FOR BETTER CONTRAST AGAINST THE BUILDING. NOTE: TAGLINE CABINET TO BE SAME DEPTH AS LETTERS. 3-1/2" LAG EMBED INTO EXISTING STUDS @ 16' O.C. OR HEADER i / \\1\11\111\\111\1\1\111\\11 �— INTERIOR LAG ANCHOR DETAIL ANCHOR DIA. HOLE MIN. ULTIMATE TENSION & SHEER LOADING IN LBS. 8 LENGTH EMBEDMENT CONCRETE STRENGTH IN PSI. AS 2000 PSI. 3500 PSI. 3/B 3/6 REQUIRED TENSION SHEER TENSION SHEER 41 SQ. FT. UP o N M 54 SQ. FT. —FTTMTAL (ENVELOPE METHOD) LOW VOLTAGE L.E.D. LIGHTING SYSTEM U.L. LISTED CLASS 2 • CONFORMS TO 11148 NEC 600 CODE .040 Aluminum Return! Ah...,• mReui.. 1/8" Whrtn Alnminnm Badkgtomd Pend .063 Alum. Back! Raceway mounted to wall wth 3/8" lag bolts @ T-0" O.C. Aluminum Raceway Painted To Match Building Color L.E.D. Light Modules 3/16" Acrylic Faces 120v/12vdc Power Supply Located Inside Extruded Aluminum Raceway. External Cut Off Switch Required '/4" Weep Holes (2 Min.) in Bottom of Letters V? Conduit Thru Wall To Raceway w/ Electrical Stub Out By Sign Installer E i 120v Electrical To 1 -Box and .._.___........... I Final Hook -Up By G.C. Electrician SECTION DETAIL - LED ILLUMINATED "METRO PCS" LETTERS - RACEWAY SIGNS PLUS" 1330 N. Forest St.Y Bellingham, WA 98225 Phone 360.671.7165 Fax 360.671.0144 signsplusnw.com 4„ METRO PCS 31007 PACIFIC HIGHWAY FEDERAL WAY, WA 98003 CLIENT: ADVANCED WIRELESS FOLDER NAME: SHARED\PROJECTS\METRO PCS\ (03) FED-03\SIGN DETAIL.CDR DATE: 9/6/2013 SCALE: AS NOTED SALES EXECUTIVE: ENTER NAME DESIGNER: MIKE LINEBRINK I FINAL SALES DATE PRODUCTION DATE REVISION DATE REVISION DATE JOB # 99843 ®p.=a°p"r.,u Underwriters J`Sr g°. Plly�,.d,,p"ort1dv u,j,,u andf,idr.l,op}'r'gl"I.— Laboratories Inc.® iy .1"I artwork ud— Jinn dl. s.ED b�sine...n.h5�g"s Plus ­h..u�..n.icn p.rni.e�n shall conaiweyo�. ae.e.�mcni o pu.rhatt Jis an.n.k L� ad.h, a," p.opos d per l'S copy rish.l�...Tle i; 9'_Chapi 5 INTERNATIONAL SIGN ASSOCIATION SERVICE NOTES LAMPS: TRANSFORMERS/BALLASTS: OTHER: - 17'-1" - 16'-51 /2" 13 SQ. FT. 10'-71/4" - Illuminated Channel Letters On Raceway/ Tagline Cabinet - 30" Tall "PGS„ INDIVIDUAL LIGHTED CHANNEL LETTERS/ TAGLINE CABINET - RACEWAY 1/2" = 1'-I1„ SCOPE OF WORK: MANUFACTURE, SHIP & INSTALL ONE (1) SET OF INTERNALLY ILLUMINATED PLD( -FACED CHANNEL LETTERS & TAGLINE CABINET. ALUMINUM CHANNEL LETTERS TO HAVE WHITE RETURNS AND TRIMCAP W/ #2447 WHITE ACRYLIC FACES W/ VINYL APPLIED TO FIRST SURFACE. "METRO" TO HAVE ARLON 5590-3412 PURPLE PERFORATED VINYL (DAY/NIGHT) APPLIED. "PCS" TO HAVE ARLON 5590-3411 ORANGE PERFORATED VINYL (DAY/NIGHT) APPLIED. ALUMINUM TAGLINE CABINET TO HAVE WHITE FILLER & RETAINERS. FACES TO BE WHITE ACRYLIC W/ #2500-3411 ORANGE VINYL APPLIED TO FIRST SURFACE. LETTERS & CABINET TO BE INTERNALLY ILLUMINATED W/ SLOAN VL PLUS WHITE SHORT L.E.D.'S. LETTERS & CABINET ARE MOUNTED TO RACEWAYS, PAINTED TO MATCH COLOR OF BLDG. METRO PCS LETTERS HAVE A WHITE 118" THICK ALUMINUM BACKGROUND PANEL MOUNTED BETWEEN THE LETTERS AND THE RACEWAY FOR BETTER CONTRAST AGAINST THE BUILDING. NOTE: TAGLINE CABINET TO BE SAME DEPTH AS LETTERS. LAG ANCHOR DETAIL EXISTING STUDS @ D.C. OR HEADER INTERIOR ANCHOR DIA. HOLE MIN. ULTIMATE TENSION & SHEER LOADING IN LBS. & LENGTH EMBEDMENT CONCRETE STRENGTH IN PSI. AS 2000 PSI. 3500 PSI. 3/8- 3/8'v REQUIRED TENSION I SHEER TENSION I SHEER 41 SQ. FT. <P o E CV M 54 SQ. TOTAL (ENVELOPE METHOD) 1 �VI�i► LOCA VOLTAGE L.E.D. LIGHTING SYSTEM U.L LISTED CLASS 2 - CONFORMS TO U.L. 48 NEC 600 CODE .040 Aluminum Returns Al—i— a bi— vs" white n:., S..Agm d P-1 .063 Alum. Backs Raceway mounted to wall wth 3/8" lag bolts @ T-0" O.C. Aluminum Raceway Painted To Match Building Color L.E.D. Light Modules 3/16" Acrylic Faces 120v/12vdc Power Supply Located Inside Extruded Aluminum Raceway - External Cut Off Switch Required /" Weep Holes (2 Min.) in Bottom of Letters /2" Conduit Thru Wall To Raceway w/ Electrical Stub Out By Sign Installer 1 i 120v Electrical To 1 -Boz and ...... ..... ....... _._.__.–._..._._._.–.__. 1 Final Hook -Up By G.C- Electrician SECTION DETAIL - LED ILLUMINATED "METRO PCS" LETTERS - RACEWAY N.'rs. SIGNS PLUS'' 1330 N. Forest St. Bellingham, WA 98225 Phone 360.671.7165 Fax 360.671.0144 signsplusnw.com ry METRO PCS 31007 PACIFIC HIGHWAY FEDERAL WAY, WA 98003 CLIENT: ADVANCED WIRELESS FOLDER NAME: SHARE D\PROJECTS\METRO PCS\ (03) FED-03\SIGN DETAIL.CDR DATE: 9/6/2013 SCALE: AS NOTED SALES EXECUTIVE: ENTER NAME DESIGNER: MIKE LINEBRINK FINAL SALES DATE PRODUCTION DATE REVISION DATE REVISION DATE JOB # 99843 P1-ITh.di.p "`h. Underwriters P,.P".1's prop.rty ofgirs Plus and is prote..ed mdv mre mdfed.rJ.npyrighs6wc Laboratories Inc.: .{ny use a(this vtwork other tlu.. direct LIS(ED husinm with Signs Plus Witham w.iurn dull ll ­­­y­.greemmt �19P­­on t. p"rch.w this ­k,.ndthed it proposed pur L'S Copy right La TI,1.1'91ChapterS INTERNATIONAL SIGN ASSOCIATION SERVICE NOTES LAMPS: TRANSFORM ERS/BALLASTS: OTHER: N f I 11'-10" ----------------- ----------- Authorized Dealer 7'-4- k 0 0 INDIVIDUAL LIGHTED CHANNEL LETTERS/ TAGLINE CABINET - RACEWAY 1/2" = 1'-0" SCOPE OF WORK: MANUFACTURE, SHIP & INSTALL ONE (1) SET OF INTERNALLY ILLUMINATED PLEX-FACED CHANNEL LETTERS & TAGLINE CABINET. ALUMINUM CHANNEL LETTERS TO HAVE WHITE RETURNS AND TRIMCAP W/ #2447 WHITE ACRYLIC FACES W/ VINYL APPLIED TO FIRST SURFACE. "METRO" TO HAVE ARLON 5590-3412 PURPLE PERFORATED VINYL (DAY/NIGHT) APPLIED "PCS" TO HAVE ARLON 5590-3411 ORANGE PERFORATED VINYL (DAY/NIGHT) APPLIED. ALUMINUM TAGLINE CABINET TO HAVE WHITE FILLER & RETAINERS. FACES TO BE WHITE ACRYLIC W/ #2500-3411 ORANGE VINYL APPLIED TO FIRST SURFACE. LETTERS & CABINET TO BE INTERNALLY ILLUMINATED W/ SLOAN VL PLUS WHITE SHORT L.E.D.'S. LETTERS & CABINET ARE MOUNTED TO RACEWAYS, PAINTED TO MATCH COLOR OF BLDG. METRO PCS LETTERS HAVE A WHITE 1/8" THICK ALUMINUM BACKGROUND PANEL MOUNTED BETWEEN THE LETTERS AND THE RACEWAY FOR BETTER CONTRAST AGAINST THE BUILDING. NOTE: TAGLINE CABINET TO BE SAME DEPTH AS LETTERS. LAG ANCHOR DETAIL XISTING STUDS @ D.C. OR HEADER — INTERIOR ANCHOR 8 ENGTDHA I HOLE I EMBEDMENT I ULTIMA E TENSION & SHEER CONCRETE STRENGTH INDPSI. IN LBS. I AS 3/8"9' I 318"V I REQUIRED I TENSION w SHEER I TENSION V SHEER TOTAL SQUARE FEET = 34.4 SA4wbA now 5 *ea �e SIGN � LOW VOLTAGE L.E.D. LIGHTING SYSTEM U.L. LISTED CLASS 2 • CONFORMS TO LUL 48 NEC 600 CODE .040 Aluminum Returns Aluminum R etamen 118" White Aluminum Background Panel .063 Alum. Backs Raceway mounted to wall wth 3/8" lag bolts @ T-0" O.C. Aluminum Raceway Painted To Match Building Color L.E.D. Light Modules 3/16" Acrylic Faces 120v/12vdc Power Supply Located Inside Extruded Aluminum Raceway External Cut OH Switch Requirec Y(" Weep Holes (2 Min.', in Bottom of Letter. /7' Conduit Thru Wall To Raceway w/ Electrical Stub Out By Sign Installer 120v Electrical To 1 -Box and ...._ ___..___......-...._... _...___.. Final Hook -Up By G.C. Electrician SECTION DETAIL - LED ILLUMINATED "METRO PCS" LETTERS - RACEWAY T r m SIGNS PLUS 1330 N. Forest St. Bellingham, WA 98225 Phone 360.671.7165 Fax 360.671.0144 signsplusnw.com METRO PCS 31007 PACIFIC HIGHWAY FEDERAL WAY, WA 98003 CLIENT: ADVANCED WIRELESS FOLDER NAME: SHARED\PROJECTS\METRO PCS\ (03) FED-03\SIGN DETAIL.CDR DATE: 9/6/2013 SCALE: AS NOTED SALES EXECUTIVE: ENTER NAME DESIGNER: MIKE LINEBRINK FINAL SALES DATE PRODUCTION DATE REVISION DATE REVISION DATE JOB # 99843 020II Sgm flue Thiurlwor4;nh< U Underwriters properrydg;gns Plusad;sprotmed 1 "-drc d.n,nd ra...I.oPy.;gh�la... L Laboratories Inca Any -..f lhu aI.—h—han dircn huu.0-wish S;gns Run wilhoul wrinm Ih;s L� ageemml to porch -e anwwA, and Jx de.igo pmpm r-, US (:opyeighlI T;,I 1719]Chape,5 INTERNATIONAL SIGN ASSOC1AxioN SERVICE NOTES LAMPS: I TRANSFORMERS/BALLASTS: RESUBMITTED OTHER: SEP 2 5 2013 CITY OF FEDERAL WAY CDS T r m