12-103561Electrical
City of Federal Way
Community & Econ. Dev. Services Permit #: 12-103561-00-E L
33325 8th Ave S
Federal Way, WA 98003 Inspection Request Line: 253 8
Ph: (253) 835-2607 Fax: (253) 835-2809 '""' p q � ) 35050
Project Name: ATIINS
Project Address: 3738 SW 332ND PL
Parcel Number: 1099610110
Project Description: (1) Install one 20 -amp dedicated circuit for 1st floor and 2nd floor bathroom GFCI
receptacles only. Replace GFCI wiring with 12/2 NM. (2) Install one 20 -amp general
branch circuit: Run 12/2 NM wire to 1st floor bathroom fan, radiant floor heater
thermostat box, and light switches; moving 1st floor bath light switches and fan off 15 -amp
branch circuit. Replace 1st floor bathroom vanity light box with two boxes for wall sconces;
run 12/2 NM cable to new boxes. (3) Upgrade wiring from 14/2 NM to 12/2 NM for one
receptacle on northeast corner of kitchen. (4) Install 20 -amp circuit in garage, i uding a
GFCI-protected receptacle. *** Addition to this permit to include moving a rical outlet
in upstairs storage room. (CJD 7-24-157. & A
Owner ARplicant 57WNERISCONTRACTOR Contractor
BENJA ATKINS BENJA ATKINS
CYNTFIIA C ATKINS 3738 SW 332ND PL
3738 SW 332ND PL FEDERAL WAY WA 98023
FEDERAL WAY WA 98023-2922
Ad
Is Use Educational or Institutional? ....................... No
Circuits - Residential ...................... 3 Thermo w..� .......................
I hereby certify that the above information is
the occupancy and the use will be in accoyl
Owner or agent:
S Friday, J 1t 31, 2015
o
e n Friday, Augus , 2012
'rect and that the?Way.
uction on the above described property and
;e with the lawand regulations of the State of Washington
the City of Fede 1-V On -11ul 6 Date: -717,1-411
-1�OP
City of Federal Way
Community & Econ. Dev. Services
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
I .. w
FILE
nectirical
Permit #: 12-103561 -00-EL
Inspection Request Line: (253) 835-3050
Project Name: ATKINS
Project Address: 3738 SW 332ND PL Parcel Number: 1099610110
Project Description: (1) Install one 20 -amp dedicated circuit for 1st floor and 2nd floor bathroom GFCI
receptacles only. Replace GFCI wiring with 12/2 NM. (2) Install one 20 -amp general
branch circuit: Run 12/2 NM wire to 1st floor bathroom fan, radiant floor heater
thermostat box, and light switches; moving 1st floor bath light switches and fan off 15 -amp
branch circuit. Replace 1st floor bathroom vanity light box with two boxes for wall sconces;
run 12/2 NM cable to new boxes. (3) Upgrade wiring from 14/2 NM to 12/2 NM for one
receptacle on northeast corner of kitchen. (4) Install 20 -amp circuit in garage, including a
GFCI-protected receptacle.
Owner
A1212licant
Contractor
BENJA Y ATKINS
BENJA ATKINS
OWNER IS CONTRACTOR
CYNTHIA C ATKINS
3738 SW 332ND PL
3738 SW 332ND PL
FEDERAL WAY WA 98023
FEDERAL WAY WA 98023-2922
Additional Permit Information
Is Use Educational or Institutional?.......................No
Electrical Fixtures
Circuits - Residential ...................... 2 Thermostat..................................... 1
PERMIT EXPIRES 3 (( I
Permit Issued on Friday, August 3, 2012
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and the Ci of Federal Way.
Owner or agent: Date:
f"
THIS CARD IS TO REMAIN ON-SITE k
CITY OF Constniction Inspection Record `
Federal Way INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 12 -103561 -00 -EL
Project: BENJA Y ATKINS
Address: 3738 SW 332ND PL
FEDERAL WAY, WA 98023-2922
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible (read left to right, top to bottom). Please schedule inspections
as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
Right of Way
Approved
UFER Ground (4295)Ditch
cover (4030) Slab/Concrete Floor (4255)
Approved
Approved Approved to place concrete
By
Date By
Date By Date
Pool Bonding (4195)
Temporary Power (4275)13 Service (4235)
Approved
Approved Approved
By
Date By
Date By Date
Feeders/Sub-panels (4045)
Rough Electrical.(4225) ❑ Ceiling Cover (4020)
Approved
Approved Approved
By
Date
Date BY Date
Final - Electrical (4055)
Approved
Rk
Dat.
Rough Electrical
Approved
Final Electrical
Approved
Right of Way
Approved
By
Date
By
Date
By
Date
13t 119'
c W -0m,
- OV To Cow.- wcoc