18-101315I y • 3 City of Federal way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 8352607 Fax: (253) 8352609 1 Building - Commercial Permit #:18 -101315 -00 -CO F I U E Inspection Request Line: (253) 835-3050 Project Name: BANK OF AMERICA Project Address: 2100 SW 336TH ST Parcel Number: 132103 9024 Project Description: TI - Removal of 2 existing ATM's, infilling north exterior wall, and installing 2 walk-up ATM's Owner Applicant Contractor Lender BANK OF AMERICA WESTMARK CONSTRUCTION WESTMARK CONSTRUCTION BANK OF AMERICA 101 N TRYON ST UNIT NCI -00 INC INC 101 N TRYON ST UNIT NCI -00 CHARLOTTE NC 28255-0001 6102 N 9TH ST SUITE 400 6102 N 9TH ST SUITE 400 CHARLOTTE NC 28255-0001 TACOMA WA 98406-2036 TACOMA WA 98406-2036 Census Category: 437 - Commercial alt / add / conversion Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area (sq. ft.) 0.00 1 0.00 1 0.00 Additional Permit Information Mechanical to be Included? ..................................... No Number of Stories ................................................... 0 Is this an Online or O.T.C. application? .................. No Permit for Building Shell Only?.............................. No Plumbing to be Included? ........................................ No Comprehensive Plan Designation ........................... Neighborhood Business Zoning Designation ................................................. BN Total Valuation: 22,000.00 PERMIT EXPIRES Monday,1 October, 2018 Permit Issued on Wednesdav, April 4, 2018 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and th a 11 be in accordance with the laws, rules and regulations of the State of ashington and the City of Federal Way. Owner or agent: Date: LA CITY or Federal Way PERMIT #: 1810131500 Project: BANK OF AMERICA 4 THIS CARD IS TO REMAIN ON-SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835,3050 Address: 2100 SW 336TH ST FEDERAL WAY WA 98023-2883 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Initial Erosion Control (4365)❑ Footings/Setback (4110) 0 Rested (4215) Floor Sheathing (4105) To be done PRIOR to breaking ground Approval to ptace concrete Approved to place concrete Electrical, Phalbilg & Me&mied R"&4n and Fk*MraR Stop iospedhins mast be siped- Approved to place concrete or grout By Date By Date By Date ® Slab/Concrete Floor (4255) El Underfloor Framing (4285) © Floor Sheathing (4105) Approved Approval to ptace concrete Approved Electrical, Phalbilg & Me&mied R"&4n and Fk*MraR Stop iospedhins mast be siped- Approved to sheath floor Date Approved to install flooring By Date .tread approved. IBC 109.3.4 By Date By Date 0 Fire/Draft Stops (4095):TBy Interim Erosion Control (4370) Final Electrical Prior to aeiedwUng a Framing ; 0 Approved Approved Electrical, Phalbilg & Me&mied R"&4n and Fk*MraR Stop iospedhins mast be siped- By Date Date Approval .tread approved. IBC 109.3.4 ® Framing (4120) By Insolation (4150) 0 Gypsum Wallboard Nailing (4130) Date Approved to insulate Approved to install wallboard Illy Approved to install mud dt tape By Date By Date Date Suspended Ceiling Grid (4265) Final - S K F & R (4060) Q Final - Planning Approved to drop the Approved 113Y Approved By Date By Date Date E9 Final Erosion Control (4375) rft:� Final - Baflding (4050) Approved Approved By Date Date Rough Electrical 0 Final Electrical 0 Right of Way Approval Approval Approval By Date By Date By Date POST -INSTALLED A14CHORS REPORT Report Number: M8181112.0004 Service Date: 12/04/18 Report Date: 12/07/18 Client Westmark Construction Attn: Tom Frank 6102 N 9th St Ste 400 Tacoma, WA 98406-2097 MAYES TESTING UVG/NEERS 10029 S. Tacoma Way Ste E2 Tacoma, WA 98499-4686 253-573-9939 Project Bank of America Twin Lakes TI 2100 SW 336th St Federal Way, WA Project No.: M8181112 Permit No.: 18 101315 000 00 CO Inspectors: Tom Callea Onsite as scheduled to perform Post Installed Anchor inspection. The contractor is installing 2 ATM machines using 3/8" x 3 Y2" Hilti KB -TZ 304/316 wedge anchors. The contractor torqued each of the 8 wedge anchors installed to 25 ft. lbs. as specified by the manufacturer. No discrepancies found. To the best of our knowledge, the items inspected today are in conformance with approved plans and specifications. Services: Special Inspection/Materials Testing Mayes Testing Engineers Rep.: Thomas Callea Reported to: Contractor: Report Distribution: (1) Westmark Construction, Tom (1) City of Federal Way WA, Building / Frank Official ; J `� (1) Gensler, Jeff Schmierer (1) Jones Lang LaSalle (Bank of Reviewed By: 1� (1) Terracon Consultants, Inc., Paul America), Tina Fite Davis Paul Davis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CT0001, 10-16-13, Rev.10 Page 1 of 1 Federal Way OF • Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: 21110 sW 3 S G -, s-+ • PERMIT#: 1 -101,3/S ejVk�' D ��✓�S S�a L( loe &AS"4i- �cs(- iASb-e£_-f IF YOU HAVE QUESTIONS CALL (g7jj�( (253) 835- -,7-(. 3 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 9),2-,q A/ DAT INSPECTOR DO NOT REMOVE THIS NOTICE Page of or PERMIT APPLICATION CITY OfVA�%' RECE, v E Federal Way �/ � J� DERMIT CENTER + 33325 81h Avenue South +Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + permitcentetf&,ciMoffederalway.com MAR 13 1018 41 n PERMIT NUMBER �) _ LIM�'�F'E� AY� kIE TARGET DATEpla SITE ADDRESS SUITE/UNIT # 2100 SW 336th Street, Federal Way, WA 98023 PROJECT VALUATION ZONING ASSESSOR'S TAIL/PARCEL # $ 22,000 BN 1 3 2 1 0 3- 9 0 2 4 TYPE OF PERMIT N BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT BANK OF AMERICA - TTW WU ATM TWIN LAKES Removal of two 2 existingATM's. Infillingexterior wall and installation of PROJECT DESCRIPTION Detailed description of uAork to two walk-up ATM's be included on this permit only NAME PRIMARY PHONE Bank of America, Tina Fite 206.200.0467 PROPERTY OWNER MAILING ADDRESS 800 Fifth Avenue, 14th Floor E-MAIL Tina. Fite am.oll.com CITY Seattle STATEZIP. WA 98104 NAME J ,, TBD QS n'l •7 MAH.Tj_ 0 _a CONTRACTOR" C C� STATEZI LN % 1 `''� kE' FAX s C- WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # NAME Jeff Schmierer PRIMARY PHONE 510.625.7467 MAILINGADDRESS Webster Street Suite 2000 2 01 jeffffs chmierer@gensler.com APPLICANT CITY' Oakland CA 194612 ZIP FAX PROJECT CONTACT NAME Jeff Schmierer PRIMARY PHONE 510.625.7467 MAMING ADDRESS 2101 Webster Street Suite 2000 E -MAD:. jeff_schmierer@gensler.com (The individual to receive and respond to all correspondence CITY Oakland STATE I CA ZIP 194612 FAX concerning this application) PROJECT FINANCING NAME ® OWNER -FINANCED When value is $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CITY, STATE, ZIP PHONE I certify under penalty of perjury that I am the property owner or authorised agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information suppii the city apart of application. Q, SIGNATURE: DATE t 219 ( b PRINT NAME: 4wc rwerer Authorized Agent) Bulletin #100 - January 29, 2016 Page I of 2 kAHandouts\Permit Application 'k . r" - VALUE OF MECHANICAL WORK MECHANICAL PERMIT Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS )Commercial) BOILERS FURNACES HOT WATER TANKS )Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR VALUE OF PLUMBING WORK PLUMBING PERMIT NONE Lakehaven Lakehaven $ 1,020,000 EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? Indicate how many of each type of fixture to be installed or relocated as part of this projeCL Do not include existing fixtures to remain. BATHTUBS )or Tub/Shower Combo) LAVS )Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kitchen/Utility) WATER HEATERS (Electric) # of HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS NONE Lakehaven Lakehaven $ 1,020,000 EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? BUSINESS -B 39,294 D Yes X No D Yes X No COMMERCIAL — NEW/ADDITION AREA DESCRIPTION Area In Occupancy Group(s) Construction # of Additional Information Square Feet a Stories Nzw BvILDINa ADDITION COMMERCIAL — REMODEL/TENANT IMPROVEMENTS Area in Construction # of AREA DESCRIPTION Square Feet Occupancy Group(s) TvDe Stories Additional Information TENANT AREA ONLY 4,032 BUSINESS -B V -B 1 PROdECTAREAAONLY 111 BUSINESS -B V -B 1 Bulletin #100 - January 29, 2016 Page 2 of 2 k:\Handouts\Permit Application �c4k