Loading...
11-102012City of Federal Way Community & Econ. Dev. Services 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 FILE Project Name: PHAN LOT 3 Project Address: 31000 20TH AVE S • ROV fuilding-' Single,,.. City Permit #: 11 -10201 -00 -SF Inspection Request Line: (253) 835-3050 Parcel Number: 053700 0595 Project Description: NEW - Construction of 2,859 sqft, 2 -story, single family residence with 68 sqft covered entry, 60 sqft deck and 877 sqft attached garage. Includes plumbing & mechanical. ***3 Bedrooms, Estimated selling price $300,000*** Owner Ap lits cant Contracto Lender LONG VAN PHAN LONG VAN PHAN 1939 LIGHTHOUSE LN NE LONG VAN PHAN 1939 LIGHTHOUSE LN NE 1939 LIGHTHOUSE LN NE TACOMA WA 98422-3467 1939 LIGHTHOUSE LN NE TACOMA WA 98422-3467 TACOMA WA 98422-3467 Gas Logs........................................ TACOMA WA 98422-3467 Census Category: 101- New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load:- oadFloor 1 FloorAreas . ft. 3,864 1 0 1 0 1 0 Additional Permit Information New / Additional Sq. Feet - I st Floor....................1371 New / Additional Sq. Feet - 2nd Floor ................... 1556 New / Additional Sq. Feet - 3rd Floor....................0 Occupancy # 1 - Area (Sq. Feet) ............................. 3864 New / Additional Sq. Feet - Basement...................0 1 Basic Plan? ........................................................... No Occupancy #I - Construction Type ........................Type V - B New / Additional Sq. Feet - Deck .......................... 60 New / Additional Sq. Feet - Garage .......................877 Gas Logs........................................ Mechanical to be Included? ................................... Yes Occupancy # 1 - Class.............................................R-3 Gas Pipe Outlets ............................. New / Additional Sq. Feet - Other .......................... 0 Plumbing to be Included? ...................................... Yes New / Additional Sq. Feet - Total.......................... 3864 Occupancy # 1 - Use ............................................... Residence (1 or 2 Zoning Designation ............................................... RS 7.2 family) 2 Dishwashers................................... CONDITIONS: 1. An automatic fire sprinkler system is required. No framing inspection until the sprinkler system is installed and approved. 2. Six Douglas Fir and/or Western Red Cedar minimum 6 -feet in height must be replaced prior to C of O. Three on the property and three on the neighboring open space tract. .V Mechanical Fixtures Ducting ........................................... 1 Fans................................................ 4 Fireplace Inserts............................. 1 Furnaces......................................... 1 Gas Logs........................................ 1 Gas Piping ...................................... 1 Gas Pipe Outlets ............................. 1 Hoods............................................. 1 Hot Water Tanks............................ 1 Plumbing Fixtures Bathtubs ......................................... 2 Dishwashers................................... 1 Laundry Washer Outlets................ 1 Lavatories....................................... 5 Showers.......................................... 3 Sinks............................................... 1 Water Closets ................................. 3 Hose Bibbs..................................... 2 — 'A %✓s CONDITIONS: 1. An automatic fire sprinkler system is required. No framing inspection until the sprinkler system is installed and approved. 2. Six Douglas Fir and/or Western Red Cedar minimum 6 -feet in height must be replaced prior to C of O. Three on the property and three on the neighboring open space tract. .V ■ gr PEOT EXPIRES Saturday, August 1' 12 r Permit Issued on MondYeb cti 2012 1 hereby certify that the above information is correct and t uon the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington A�7— and the City of Federal Way. Owner or agent: / �' — F l � CCP Date: �Z City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed byCHy staff. Tenant Name: PHAN LOT 3 Address: 31000 20TH AVE S Permit #: 11 -102012 -00 -SF Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction T Type V - B Occupancy Load Floor Area (sq. ft.) 3,864 1 0 0 0 Owner Name: LONG VAN PHAN LONG VAN PHAN Owner Name: Owner Address: 1939 LIGHTHOUSE LN NE TACOMA WA 98422-3467 e7 -go 2- /- /3 Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severly affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner / occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. 4 THIS CARD IS TOMAIN ON CITY OF VINM�M�� • Construction In ectlon Record Federal Way INSPECTION REQ TS: (253) 835-3050 PERMIT #: 11 -102012 -00 -SF Address: 31000 20TH AVE S Project: LONG VAN PHAN FEDERAL WAY, WA 98003 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. SWM Precon Site Mtg (4400) Initial Erosion Control (4365) Footings/Setback (4110) Approved To be done prior to breaking ground Approved to place concrete By t1V Date '3/1//Z, By 11,,,41' Date 31171 1'2_ BY Date Rough Electrical Approved Final Electrical Approved 1:1Approved Foundation Wall (4115) 0 Drainage/Downspout (4040) Plumbing Groundwork (4190) Date Approved to place concrete By Approved to backfill Approved to cover By Date �, _ By flit' Date S-4 -/"y By Date Slab/Concrete Floor (4255) Underfloor Framing (4285) Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By l� Date r-14 -/-Z By /v/ Date Shear Walls (4245) ❑ Roof Sheathing (4220) 0 Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved B Date _� Z By Date �'-�2 -/2 B Date Mechanical Rough -in (4165) Gas Piping (4125) Fire/Draft Stops (4095) Approved Approved to release test 10P51 Approved By Date �Z By Date 8_b �'Z By Date Interim Erosion Control (4370) Framing (4120) prior to scheduling inspection; By/0 Approved Date Electrical, Plumbing &al Rough -in andApproved �a:Framing Fire/Draft Stop inspectibe signed off and/"� to insulate approved3.4 By Date /C Insulation (4150) Gypsum Wallboard Nailing (4130) Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By fZ Date CT 7-� By Date ; �% - By /y�C Date Final - Mechanical (4065) Final - Plumbing (4075) Final - Building (4050) Approved Approved Approved By Date ��-/._3 By Datej" By Date Rough Electrical Approved Final Electrical Approved 1:1Approved Right of Way By Date By Date By Date GEORGE GERGM P. E. CIVEL-STRUCTURAL-GEOT.EC MCAL 12701 111 th Ave E Puyallup, Wa 98374 (253) 241-3334 May 02, 2012 Mr. Long Van Phan Federal Way, WA Re: New two story structure located at 31000 201' Ave SW, Federal Way, WA 98003. City of Federal Way. Owner: Long Van Phan Dear Mr: Phan This letter addresses the garage front walls of the subject building PURPOSE OF LETTER This is to address the garage front walls. FINDINGS The garage front wall consists of three shear walls. The size on the plans was two feet each. There will be 1 %2 deducted for the door trim. The new dimension will be slightly shorter. The difference in length of the walls is small and will not result in changes. Therefore, the garage front shear walls may remain 1/2"plywood with l Od @3"inches on center. Should you have any questions regarding the content of this report, please contact George Gergis at the above address. Sincerely, George Gergis y nn '/ARECE111Federal Way WERMIT COMMUNITY DEVELOPMENT SERVIc9AY 2 "APPLICATION 253-835-2607• FAX 253-835-2609 SOF FEDERAL WAY rnc� �S*F 1 1 CO ME PL DE EN FP 3� SITE ADDRESS 31000 J!h� SUITE/UNIT # PROJECT VALUATION $ ZONING ASSESSOR'S TAX/PARCEL # aS-Cc_�s�s TYPE OF PERMIT XBUILDING PLUMBING MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT (Tenant Name/HomeoumerLast Name) Plq�4N L C PROJECT DESCRIPTION Detailed description of work to coc�l6?'rzuc ��iV or ,4 �Ew SFie kvl7-A4 _ be included on this permit only PROPERTY OWNER NAME L. /b'c� N6v y�' NE PRIMARY PHONE MAILING ADDRESS l93g L/GN7*'g6C56 L, 46 t4E, E-MAIL CITY r ACD�-4,A STATE c )A ZIP J794 2i , PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # NAME Lo%(G PNat-I / ��+/ 1 ��i /�./p+�/. Cw �' Y C/ 7 �7 PHONE APPLICANT MAILING ADDRESS F -MAIL CITY STATE - I ZIP FAX PROJECT CONTACT (The individual to receive and —_L NAME IA $rzP_4 A. i—I r_7© f— VA L.. PHONE2�� V MAILING ADDRESS // �i�t ZY 1e.C/[�([• �L E-MAIL � �.�/ �L.Gi ✓•42%�� respond to all correspondence concerning this application) CITYSTATE Ko T t-e�,4 • ZIP 1?0 �O - FAX ALTERNATE CONTACT NAME: PHONE E-MAIL PROJECT FINANCING Required value of $5,000 or more NAME �( OWNER -FINANCED X MAILING ADDRESS, CITY, STATE, ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. 1 certify that to the best Of my knowledge, the information submitted in support of this permit application is true and correct. 1 certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE- 7z PRINT NAME: Bulletin #100—January 1, 2011 Pagel of3 Ul-landoutsTermit Application a 59 0 VALVE OF MECHAMCAL WORK $ / ` ' (a copy of bid or estimate must be provided) Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS (Commercial) BOILERS _� FURNACES HOT WATER TANKS (c—) COMPRESSORS �_ GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain - L BATHTUBS (or Tub/shower combo) _t:F LAVS (Hand Sinks) _9 TOILETS WATER PIPING I DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kitchen/utility) WATER HEATERS (Electric) Z HOSE BIBBS SUMPS WASHING MACHINES CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? /O :—;5• r 4 D Yes D No D Yes D No AREA DESCRIPTIONI Area I Occupancy Groups) I Construction I # of I Additional Information in Square Feet Tvue Stories ADDITION AREA DESCRIPTION Area in Square Feet TENANT AREA ONLY Occupancy Group(s)Construction I # of Additional Information Tvve Stories Bulletin #100 – January 1, 2011 Page 2 of 3 kAHandouts\Permit Application GENERAL NOTES FILTER FENCE CONSTRUCTION ACCESS TEMPORARY SEEDING AND MULCHING PLASTIC COVERING sroacP,�Es STORM DRAIN INLET (INSERT) METAL FENCE POSTS SEEDING MAY BE USED ONLY BETWEEN APRIL 1 AND JUNE 30, AND SEPTEMBER 1 AND OCTOBER 30. /- ANCHOR WEIGHTS WITH STAKES PRE -MANUFACTURED CATCH BASIN OR INLET INSERT FILTER FABRIC MATERIAL 60" WIDE // STRAW WATTLE BOLLS. USE STAPLES OR WRE RINGS TO ELECTRICAL CODE ALL WORK SHALL COMPLYEC2 WITH IBC-200 AND WITH ALL LOCAL CODES; Sys ROP° LENGTH PER THE OPD S TE W ///- SEEDMATREAREA D, TOR HYDRO 0 SEEDING FIBER PPED AND THEN TEMPORARILY \ 10' MAX. SOIL BERM PREACAPPRa E� EgUWARE MIRAFl 700% OR MECHANICAL CODE IMC "2100, DEVELOPMENT INSPECTOR � $ / TECHNIQUES. � � STRAW BALES PLUMBING CODE y // » ® o it FIRE CODE NFPA /R-25' MIN; ;' "� • N a () 2" X 2" X 1490 WIRE FABRIC OR EQUIV. / - '^ ' (OPr1ONAL-PER SITE CONDITION) DO NOT SCALE DRAWINGS, VERIFY ALL DIMENSIONS PRIOR TD NOTIFY OF coNv£Y RUNOFF TO APPROVED LDGAnDN. le ;' ti ' • , r BURY BOTTOM OF FILTER MATERIAL IN 8' ' "•, , X 12' TRENCH ANY DISCREPANCIES. IF WORK STARTED PRIOR NOTIFICATION, THE GENERAL CUT SLOPES .. AND THE SUB CONTRACTOR PROCEED AT THEIR OWN RISK y BURY SHEETING IN 4 IN. X 6 IN, TRENCH A ANCHOR WEIGHTS WITH STAKES ' �1 ` 6•-0' STRAW MULCHING y' MINIMUM Of 8 FT. SETBACK FROM TOP OF ( MAXIMUM 1. FOR AREAS OF SITE WITH LESS THAN 307 SLOPE � - �, 10' MAX. NOTES,* U u PLAN DIMENSIONS ARE TO NOMINAL FACE OF STUDS, FACE OF CONCRETE E 2-3 BALES OF STRAW EQUALS 2-INCHES OF SLDPE. BACKFILL WITH WASHED ROCK. CONVEY RUNOFF TO 1. STORM DRAIN INLETS NEED TO BE REMOVED OVERFLOW (TO BYPASS WALLS, CENTER UNE OF COLUMN GRIDS, U.N.O. 4"-8" QUARRY SPALLS STRAW MULCH OVER 1000 SRARE FEET. APPROVED LOCATION, AT THE END OF THE JOB. PEAK STORM VOLUMES) FILTER FABRIC MATERIAL 2, MULCH SHALL BE WEED FREE STRAW. 2. STORM GRAIN INLETS ARE ONLY T0:8E HE - .... .:...........:.......... •................. ... . PROVIDE FULL WIDTH ....... .....:._. .... ...::.. .:. .. :.... :•: :..:'..:::::,. •. ..::: :.:':.::........:.::::;•::-. MANUFACTURER'S IRE OMMENDATIQNS.CATCN PE AT THE END OF RUN. IN TE: ANGLE SILT FENCE BACK UP T VERIFY ALL ROUGH - IN DIMENSIONS FOR WINDOWS, DOORS, PLUMBING CEO -TEXTILE FABRIC :ABLE.& SEfDR2G.,MtX}llJ3ES"... ..........:.:. :..:.. ... ...:....::.......: ::.. :.:....: .- ......'„ {' \ BASIN INSERTS ARE NOT TO BE INSTALLED �-0 o FIXTURES AND APPLIANCES PRIOR TO COMMITMENT OF WORK. INGRESS/EGRESS AREA PROVIDE ENERGY DISSIPATION AT TOE WHEN NEEDED. + NAME PRDP0Rnms- Y R DiT R PURITY 7. GERMINATION \ 10' MAX. W CURB INLETS. 1n \ 3. INSERTS SHALL BE INSPECTED AND MAINTAINED BACKFlLL WITH NATIVE SOIL MATERIAL 12" MIN. THICKNESS REDTOP (AGROSTIS ALBA) 107 92 90 TOE IN SHEETING IN 4 IN. % 6.IN, TRENCH A 3 MIN' WHEN A 1/2 INCH RAIN ACCUMULATES WITHIN A OR GRAVEL BACKFILL IN TRENCH AND VERIFY SIZE AND LOCATION AS WELL AS PROVIDE ALL OPENINGS THOUGH ANNUAL RYE (LODUM MULTIFLORUM) 40% 48 90 MINIMUM OF 3 FT. SETBACK FROM BOTTOM -• •---•— 24 HOUR PERIOD. CLEAN AND/OR REPLACE INSERT ON BOTH SIDES OF FENCE OF SLOPE. BACKFILL WITH WASHED ROCK. WHEN HALF OF THE TRAP IS FILLED WITH SEDIMENTS. FABRIC ON THE SURFACE FLOORS AND WALLS, FURRING, CURBS, ANCHORS, INSERTS, MACHINE BASES GHEVANGS FESCUE (FETUCA RUBRA GOMMurnrA) 40% 97 60 '�-':: '" -::: , AND ROUGH BUCKS / BACKING FOR SURFACE MOUNTED ITEMS. INCLUDING ACCESS SHALL . USED M ALL AREAS VI THE SITE WITH VEHICLE TRAFFIC AND PARKING, WHITE DUTCH CLOVER (TRIFODUM PEPENS) 40% 96 90 CONVEY RUNOFF TO APPROVED LOCATION, INCLUDING PLANTING STRIPS. OTHER MEANS Of PROVIDING STABILIZED ACCESS WILL HE CONSIDERED. . T ND IMMEDIATE N T SLOPES AND . TO PREVENT SEDIMENT ENTERING STORM DRAINAGE SYSTEMS PRIOR TO /+� TO 1NTERCEFT k.DE�:IJN SMALL AMOUNTS OF SEDIMENT UNDER SHEET FLOW CONDITIONS FROM TO.REDUCE THE AMOUNT OF MUD, DIRT, ROCKS; ETC, TRANSPORTED ONTO . TO PROVIDE TEMPORARY SOIL STABILIZATION BY PI.ANtiNG GRASSES AND LEGUMES TO AREAS THAT WOULD 0 PROVIDE EOIATE TEMPORARY EROSION FROTECTIO 0 SLO REASON:. RtN CONSTRUCTION. VELOCITY OF SHEET OHS. " PROVIDE FURRING AS REQUIRED TO CONCEAL MECHANICAL AND/ OR ELECTRICAL REASON. PUBLIC ROADS BY MOTOR VEHICLES OR RUNOFF. REASON' REMAIN BARE FOR MORE THAN 7 DAYS WHERE PERMANENT COVER IS NOT NECESSARY OR APPROPRIATE. REASON. DISTURBED AREAS THAT CANNOT BE COVERED BY MULCHING & MATTING REASON. PERMANENT STABILIZATION OF THE DISTURBED AREA. DISTURBED AREAS DU G CON UC ON TO DECREASE FL SYMBOL: SYMBOL: - : mm. HARD WARE IN FINISHED AREAS. SYMBOL: � SYMBOL: Ts sa' _.. _ _ _ REPETITIVE FEATURES ARE OFTEN DRAWN ONLY ONCE AND SHALL BE COMPLETELY PROVIDED AS IN DRAWN FULL. ASBREw!!AWN DOORS NOT DIMENSIONALLY LOCATED SHALL BE 3" FROM STUD FACE OF DOOR OPENING OR CENTERED BETWEEN OR CENTERED BETWEEN WALLS AS SHOWN. PROJECT DATA ABV: ABOVE AFF. ABV. FINISHED FLOOR "FLOOR LINE" REFERS TO TOP OF CONCRETE SLAB OR TOP OF SUBFLOOR. ADJT. ADJUSTABLE OWNER: L»O,NG F'1 /dN !-ti1YD LIEU NGUY�'N A/C AIR CONDITION PARTITIONS ARE 2x4 @ 16" O.G., UNL/"9 L.JGTRJ67l ESS OTHER WISE NOTED. iSE LsvJ5 JIE 7AC.O9-1.C> A.B. ANCHOR BOLT PROJECT ADDRESS: 3JOxx 20 %�, A✓� �• f�'BD. WAY : AVERAGE VENT ALL BATHROOM/LAUNDRY FANS, RANGE HOODS ( UNLESS APPROVED SELF- AVG. V AVGBEAM VENTING j , AND DRYERS TO OUTSIDE ATMOSPHERE PARCEL #: BF. BI -FOLD 1MPPERV1®U ,6 A941rA MAX. DRYER DUCT LENGTH IS 14'-0" UNLESS U.L APPROVED MECHANICAL CODES. ZONING: BED. BI - KI INFI LT2ATtC7l t PbZ01fl p U FOR J fJ7 'J. 4GXx� = FT i! AKG. BLOCKING CANT. CANTtUVEF? VERIFY CONSTRUCTION OF VENT SPACE WITH 200 I.B.0 AND LOCAL SCOPE OF WORK: ColVorZUGT'lpN OF A'1149W 0F9, CLG: CLG. ORDINANCES. W/3 CAZ5J" C,,AR.AC;� ,A7 AC.P1ED. JMPERV100!1 a ARE�4 L.O?' CY. CERAMIC TILE 900F AREA 2513 5Q-P'r CLR. CLEAR PROVIDING ANCHORING AND BRACING @ WATER HEATERS TO RESIST DRfVeWAY-PAi1C7 9lv8 aQ.F7' CL, CLOSET EARTHQUAKE MOTION. OCCUPANCY GROUP: !2. 3 , u. T8T<SL, .348/ SOFT' COL COLUMN CONC. CONCRETE PROVIDE APPROVED NUMBER OR ADDRESS POSITIONED TO BE PLAINLY VISIBLE CONSTRUCTION TYPE V b (4pr11ZF 12na) . CLOST. CONSTRUCTION AND LEGIBLE FROM THE STREET. CONT. CONTINUE (200 I.B.C. 501.2) PLUMBING INSTALLATIONS TO BE INSPECTED BY COMPLIANCE SET SACKS: FRONT: ✓�J 8�8 CODRYCONS RCTIDN SIDE R 5 BSI.. B • D: ' DRYER OFFICER PRIOR TO COVERING WORK. REAR 5, L35L 6 DTL. DETAIL OR: DOOR NO BUILDING OR PORTION OF A BUILDING SHALL BE OCCUPIED OR USED FOR OR DOWNSPOUT STORAGE PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. AREA: FLOOR LIVING AREA DSP. DISPOSAL 9•F 1 OW. DISHWASHER a a NO EXCEPTIONS". APPROVAL FOR OCCUPANCY IS ONLY GRANTED AFTER Ux'PR /5510 5 •F ` EA, EACH w ACCEPTANCE BY PUBLIC WORKS, PLANNING FIRE MARSHAL, AND BUILDING " ELECT. ELECTRICAL OFFICIAL. TOTAL 2859 5.R _ _A/g 9 4�✓ 22 E , !3$s:'5O - ELEV. ELEVATIONS THE UST SMALL INDICATE THE NAME OF THE INSPECTOR, DATES, AND TIMES GARAGE: 8'22 S.F.� raXIleTt 6 MOGf4�Y EQ; EQUAL r2;ar L 6. EQUIP: EQUIPMENT S PRESENT ON THE JOB SITE AND TYPES OF INSPECTIONS BEING CONDUCTED. EXT. EXTERIOR }, T�2aTEcT �+No 'n�rzM P✓LT av EW: EACH WAY � ALL REQUESTED INSPECTIONS SHALL BE CALLED IN ON THE 24 HOUR INSPECTION DECK / PORCH: 16P4 0-1~ TrzAcTbTZ DR41N GON EG7'1Dl l 7b Vc9ID CaV REQUEST PERMIT.- SLR ,� $p FF. FINISHED FLOOR ��.=.171Ni�'N%' TOlNp1GTlZATO 7�Za5t�jGkl . LOT SIZE: 10�44 0--F- A , d /`\ i a a'. zbvPub 5 lz�tar�t. PLR. FLOOR CHANGES TO APPROVED PLANS SHALL FIRST BE APPROVED BY THE BUILDING !^}C!5 ll�lC, ASP941- ?�- Q . FIG: FOOTING OFFICIAL LOT COVERAGE: 21 'c 0 : , s ' , a — — — -- -- - I . FOT. FOUNDATION lyj a ... Ga. GAGE Z to L?2dv6 ' i GV. GALVANIZED -4 COPIES OF SUCH APPROVALS SHALL BE ON THE JOB SITE PRIOR TO ► ' LEGAL DESCRIPTION: •< � `�:'� I .—_. '� GLS: GLASS COMMENCEMENT OF WORK. °' A GUBo GLUE LAM BEAM ` GWB; GYPSUM WALL BOARD ALL MATERIALS & PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH BUR. HANGER Y) MANUFACTURES WRITTEN INSTRUCTIONS & INSTALLED IN ACCORDANCE WITH �7-C9' - ' I STANDARD & EXTEND WARRANTIES, AS APPLIES, s e': i 1 HQVti/. HARDWARE LYtfou iV ". I—___--1= HDR. HEADER U uiz SOLELY AS A CONVENIENCE TO THE OWNER AND CONTRACTOR, THE DESIGNER hD '1J 6 1 I HTI' HEATING' et MAY INCLUDE DOCUMENTS PREPERED BY CERTAIN CONSULTANTS AND/OR : , i i HT. HEIGHT CQNTRvcrloN Acc VENDORS (OR INCORPORATE THE RECOMMENDATIONS OF SAID CONSULTANTS _ , .-' �� i AND/dR VENDORS INTO �CUMENTS PREPARED BYTHE DESIGNER] WITHIN L.= •Jc7714 f'/!nt`�f' �T27;F HC HOLLOW CORE i I ,, HOR HORIZONTAL THE SET OF DOCUMENTS ISSUED BY THE DESIGNER. IT IS EXPRESSELY ¢ �`3 C�UQ 2RY SPAcL�� '6: = p. , i /Casa H& HOSE BIBB UNDERSTOOD, THAT BY SUCH ISSUANCE, THE DESIGNER ASSUMES NO LIABILITY Ci�O'7'EC7"tl FA�k'1C: y > „ 1 HWT. HOT WATER TANK FOR THE SERVICES OF SAID CONSULTANT AND/OR VENDORS. WJ J�N njC>T th! U5 WILL 1 A' - -'— .. <: ': i " . " ' : ' iNSUL. INSULATION ��cor t J.�Jvw�y + I 1 TNT. INTERIOR PROTECTION: SAFETY BARRICADES, FENCES TEMPORARY WALKS, AND SIGNALS Ifl 5 �a JO 1 - -� � ,.- I�' � �� J T. JOIST SHALL BE ERECTED IN COMPLIANCE WITH THE LOCAL BUILDING CODES AND I �' N. LINEN POLICE REGULATIONS. r -- - + •'. � J LAVATORY . THE PROJECT SHALL BE CLEAND AND IN WORKING ORDER PRIOR TO ACCUPANCY LIVELOAD S I T S P A N a: MANUFACTURE :' b i L MATERIAL z M COORDINATION NOTES i i MAXIMUM � - _ MG: MEDICINE CABINET THE FOLLOWING NOTES SHALL SERVE AS A GUIDE TO THE CONTRACTOR TO VERIFY j / 1 I MECH. MECHANICAL oS .n o EACH CONDITION WITH THE PRODUCT, MANUFACTURER OR SUPPLIER, AND/ OR t., MTL. METAL Z .t LOCAL JURISDICTION FOR THEIR REQUIREMENTS PRIOR TO SUBMITTING A BID TO p i I MIN. MINIMUM 'R THE OWNER OR PROCEEDING WITH WORK ° I j MISC. MISCELLANEOUS W , $ . THE ITEMS OUTLINED BELOW ARE NOT INTENDED TO BE AN EXHAUSTIVE ANAUSYS I tti 1 OF ALL POSSIBLE AREAS OF CONCERN OR CONFLICT, BUT RATHER TO SERVE A5 Q MAD MOLDING < I? � t11 J 1 '' THE BEGINNING POINT IN IDENTIFYING COMMONLY OVERLOOK AREAS IN THE S 3041" ST 00 NA. NOT APPLICABLE 5 M R CONSTRUCTION PROCESS. Fl Prr?!'C z TUTS: NOT TO SCALE F.F. 11. 1 A.JG°7(8� : 11 DBS. - OBSCURE b N -ul / I D.C. ON CENTER „ 1: REVIEW MANUFACTURER'S PRODUCT LITERATURE FOR INSTALLATION" { / INSTRUCTIONS UNIQUE TO THE PROJECT CONSTRUCTION TYPE. I ?a PL PLATE OR PROPERTY LINE v S a) HVAG. EQUIPMENT AND DUCTINGSAIL 22. r I 3 .p� 21 O PLWD. PLYWOOD e a + PTLAWE. PRESSURE TREATED b) RECESSED AND SEMI -RECESSED LIGHTING cn REF. REFRIGERATOR c ) ALL EXHAUST FANS AND DUCTING ROOM S 4 RM: d) BATH TUB AND SHOWER ENCLOSURES. E) RECEPTACLE BOXES (TV., TELEPHONE, ELECTRICAL AND PLUMBING «s I / I R & S ROD & SHELF cv ( SHTHG SHEATHING 2: COORDINATE WITH THE FOLLOWING UTIUTIES AND COMPLY WITH y ,jCl SC. SOLD CORE LOCAL JURISDICTIONAL REQUIREMENTS. S�pm k!!�E SPEC. SPECIFICATION y . a) GAS UTILITY t2?; o b) TELEPHONE UTILITY 31 o SQUARE o STANOAR W' N c) CABLE TV. AND UTILITY H / d) POWER UTILITY I SINWALL e) TRASH SERVICE %i TEL TELEPHONE f) LOCAL DISTRICT FOR WATER, SEWER AND STORM r`�B TV. TELEVISION ! �9 3.- THE FOLLOWING ITEMS SHALL BE DESIGN BUILD SYSTEMS AND , THK. THICK � , r . a T.P. TOILET PAPER o SHALL BE APPLIED FOR BT THE CONTRACTOR ATA LATTER DATE. N ��' N o THE CONTRACTOR SHALL PROVIDE A COMPLETE SYSTEM TO THE OWNER -- T & G TONGUE AND GROOVE 0 — — N.89d 43 22"� f TYP. TYPICAL @ > N WHICH COMPLIES WITH ALL JURISDICTIONAL REQUIREMENTS. ��` 81 S _ - . a ELECTRICAL U.NO. UNLESSE THERWISE`'. V:B VAPOR A RI 1� ui c b) PLUMBING c J MECHANICAL/ HEATINGVK*4ff MAP W. VERTICAL d W. WASHER fr,+';I; 13 2012 � d) FIRE SPRINKLER W.M. WIRE MESH M>S WD. WOOD "'11-y OF FEDERAL W,4Y W / WITH COS