18-103056City of Federal way
Community Development Dept
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835.2607 Fax (253) 836.2609
x
Building - Single Family
FILE Permit #:18 -103056 -00 -SF
Inspection Request Line: (253) 835-3050
Project Name: RETREAT MEADOWS LOT 52
Project Address: 176 SW 358TH ST
Parcel Number: 724290 0520
Project Description: NEW - Construction of a 2 -story, 3264 square foot single family residence with a 60 square
foot covered entry and a 420 square foot deck, including plumbing and mechanical. *** 4
bedrooms; $350,000 estimated selling price***
Owner
Applicant
Contractor
Lender
LENNAR NORTHWEST INC
JULIE FISONLENNAR
LENNAR NORTHWEST INC
0
33455 6TH AVE S SUITE 1-B
NORTHWEST INC
33455 6TH AVE S SUITE 1-B
No
FEDERAL WAY WA 98003
33455 6TH AVE S UNIT 1-B
FEDERAL WAY WA 98003
0
New / Additional Sq. Feet - Garage ........................
FEDERAL WAY WA 98003
Mechanical to be Included?.....................................
Yes
Census Category: 101- New Single Family House
Includes:
#1 #2 #3 #4
Occupancy Class:
R-3
Construction Type:
Type V - B
Occupancy Load:
0
Floor Area (sq. ft.)
0.00
Additional Permit information
New/ Additional Sq. Feet -1st Floor .....................
1645
New / Additional Sq. Feet - 2nd Floor....................
1619
New / Additional Sq. Feet - 3rd Floor .....................
0
Occupancy #1 - Area (Sq. Feet)..............................
0
New / Additional Sq. Feet - Basement ....................
0
Basic Plan? ...........................................................
No
Occupancy #1 - Construction Type .........................
Type V - B
New / Additional Sq. Feet - Deck ...........................
0
New / Additional Sq. Feet - Garage ........................
420
Mechanical to be Included?.....................................
Yes
Plumbing Work Valuation? .....................................
20000
Mechanical Work Valuation?..................................
10000
Number of Stories ...................................................
2
New / Additional Sq. Feet - Other...........................
60
Plumbing to be Included? .................. ................
......
Yes
New / Additional Sq. Feet - Total...........................
3744
Will Certificate of Occupancy be Issued? ...............
Yes
Occupancy #1 - Use................................................
Residence (I or 2
family)
Comprehensive Plan Designation ...........................
SF - High -Density
Zoning Designation .................................................
RS 7.2
Residential
Ducting 1 Fans 5 Fireplace Inserts 2
Furnaces I Gas Piping 5 Gas Pipe Outlets 5
Hot Water Tanks 1
Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1
Lavatories 5 Showers 1 Sinks 1
Water Closets 3 Hose Bibbs 2
11 .,
PERMIT EXPIRES Monday, 21 January, 2019
Permit Issued on Wednesday, July 25, 2018
I hereby certify that the above
and the occupancy and the
Owner or agent:
d" V ♦ a
mation is correct and that the construction on the above described property
will be in accordance with the laws, rules and regulations of the State of
Nashington and the City of Federal Way.
City of Federal Way
Certificate of Occupancy
Date: L 2T-/9
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance, this structure was in
compliance with the various ordinances of the City regulating building construction or use. This certificate is valid
ONLY when endorsed bV City staff.
Tenant Name: RETREAT MEADOWS LOT 52
Address: 176 SW 358TH ST
Includes: #1 #2
Occupancy Class: R-3
Construction Type: Type V - B
Occupancy Load: 0.00
Floor Area (sq. ft.) 0.00
Owner Name: LENNAR NORTHWEST INC
Owner Address: 33455 6TH AVE S SUITE 1-B
FEDERAL WAY WA 98003
uilding Official
Permit # 18 -103056 -00 -SF
#3 #4
Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/ occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises.
crry w
Federal Way
PERMIT #:
Project:
THIS CARD IS TO REMAIN ON-SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
18103056 00 Address: 176 SW 358TH ST
LENNAR NORTHWEST INC FEDERAL WAY WA 98023
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
El
SWM Precon Site Mtg (4400)
0
Initial Erosion Control (4365)
0
Footings/Setback (4110)
Approved
Illy
To be done PRIOR to breaking ground
Approved to place concrete
By
Date
ByQ-C Date R. z0
Date
By
Date
®
Foundation Wall (4115)
®
Drainage/Downspout (4040)
®
Plumbing Groundwork (4190)
Approval to place concrete
Approved to backfill
Approved to cover
By
Date
ByQ-C Date R. z0
Date ( 6
By
Date
I By
Date
By
El
Slab/Concrete Floor (4255)
®
Underfloor Framing (4285)
Floor Sheathing (4105)
Approved to place concrete
Approved to sheath floor
Approved to install flooring
By
Date
By
hfi Date /d i 5
By
Date
o
Shear Wang (4245)
0
Roof Sheathing (4220)0
Rough Plumbing (4230)
Approved to install siding
Approved to instal roofing
Approved
By
Date 11 Z
By
t)3 Date �l
By
Date
13
By
Mechanical Rough -in (4165)
Approved
Date lk-4,Datey
4
Gas Piping (4125)
Approved to release Lest
�-
®
1By
Fire/Draft Stops (4095)
Approved
Date ^ 1
®
Interim Erosion Control (4370)
Approved
Prior to scheduling a Framing
Electrical, PlmaNng & Mechanical Roagb4n
and Fire/Draft Stop inspections mit be signed -
0
1By
Framing (4120)
Approved to iasul to
By
Date
oRand approved. IBC 109.3.4
Date 1
is
Insulation (4150)
0
Gypsum Wallboard Nailing (4130)
99
Final Erosion Control (4375)
Approved to install wallboard
Approved to install mud dt tape
Approval
By
Date - 1,
By C Date _3
By
Date
El
Final - Mechanical (4065)
2
Final - Plumbing (4075)
Final - Building (4050)
Approved
Approved
Approval
By
P {2 Date 1 - 2 4 1 Q
By
C U Date 1. 4 1 o,1By
2 _ Date 1 �- ZR '1 L'
0 - k1,L_ k*u, 016
Rough Electrical
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
I By
Date
By
Date
3264
JUL 1 1 2018
CITY OF FEDERAL wAYPERMIT APPLICATION
CITY OF �� C)OMMUNI7Y DEVELOPMENTFederal Way
PERMIT NUMBER _ 0TARGET DATE �J I
- � - -
SITE ADDRESS
SUITE/UNIT M
176 SW 358th St
PROJECT VALUATION
ZONING
ASSESSOR'S TAX/PARCEL 4
$ 175,000.00
RS7 2
7 2 4 2 9 0_ 0 5 2 0
TYPE OF PERMIT
MBUILDING M PLUMBING VMECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
Retreat Meadows
Build 2 story SFR 3264 Sq Ft. Lot 52
PROJECT DESCRIPTION
Detailed description of work to
be included on this permit only
.
NAME
Lennar Northwest Inc.
PRIMARY PHONE
253-590-2213
PROPERTY OWNER
MAILING ADD S
33455 6ti Ave S., Unit 1-B
E-MAIL
julie.fison@lennar.com
c`TTederal Way
sTWA
ZIP 98003
NAME
Lennar Northwest Inc.
PH253-590-2213
MAILING ADDRESS -
33455 6th Ave S., Unit 1-B
E-MAIL
'ulie.fison@lennar.com
CONTRACTOR
°ITYFederal Way
ST WA
V V
ZIP 98003
FAX
WA STATE CONTRACTOR'S LIbENSE Y
EXPIRATION DATE
FEDERAL WAY BUSINESS LICENSE M
CC LENNNANI893QG
11/ 7 /2019
NAME
Julie Fison
PRIMARY PHONE
253-590-2213
APPLICANT
MAILING ADDRESS
33455 6th Ave S., Unit 1-B
E ,
)ulie. fison@lennar.com
CITY
Federal Way
STATE
WA
21P98003
FAX
NAME
P
253)P590-2213
PROJECT CONTACT
Julie Fisori
MAILING ADDRESS
33455 6th Ave S., Unit 1-B
E-MAIL
julie.fison@lennar.com
(The individual to receive and
respond to all correspondence
CITfederal Way
STATE
Z198003
FAX
concerning this application)
PROJECT FINANCING
NA!"tennar Northwest Inc.
®—s tlsl �N es?o---
When value is $5,000 or more
(RCW 19.27.095)
MAILING ADDRESS, CITY, STATE, ZIP
33455 6th. Ave S., Unit 1-B Federal Way, WA 98003
PHONE
(253) 590-2213
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
irVormation supplied to the city as apart of this application.
SIGNATURE: gldoit. DATE 7/9/2018
PRINT NAME: Julie Flson
Bulletin #100 — February 22, 2016 Page 1 of 2 k:\Handouts\Permit Application
AL
MECHANICAL PERMIT
Indicate how many of each typ
AIR HANDLING UNITS
AIR CONDITIONER
BOILERS
COMPRESSORS
1 DUCTING
PLUMBING PERMIT
Indicate how many of each type o re to be installed or relocated as part of this project. Do not include existing res to remain.
BATHTUBS )or Tub/Show rcombn) LAVS (Ha dSinks) _3 TOILETS WATER PIPING
1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe)
DRAINS 1 SHOWERS VACUUM BREAKERS
DRINKING FOUNTAINS 1 SINKS )Kitchen/Unlit WATER HEATERS (Eiectri,)
7— HOSE BIBBS SUMPS �_ WASHING MACHINES 16 TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY?
WATER PURVEYOR
SEWER PURVEYOR
VALUE OF EXISTING IMPROVEMENTS
N/A
Lakehaven Utilty District
# of
N/A
Square Feet
a
EXISTING/PREVIOUS USE
LOT SIZE (In Square Feet(
EXISTING FIRE SPRINKLER SYSTEM?
PROPOSED FIRE SUPPRESSION SYSTEM?
Vacant
7,479
❑ Yes M No
❑ Yes IX No
COMMERCIAL — NEW ADDITION
AREA DESCRIPTION
Area in
Occupancy Group(s)
Construction
# of
Additional Information
Square Feet
a
Stories
77777777
NEW BUILDING •
- -
ADDITION
COMMERCIAL — REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION
Area in
Occupancy Group(s)
Construction
# of
Additional Information
Square Feet
a
Stories
TOTAL Bd[iptxG
TENANT AREA ONLY
PROJECT AREA ONLY .
Bulletin #100 —February 22, 2016 Page 2 of 2 k:\Handouts\Permit Application
RECEIVED
FILE
JUL 11 2018
t4�p
Lakehaven GM "DE'V L PME
WATER &SEWER DISTRICT GOMMUNIT'(DE1't:LOPMENT
Lakehaven Water & Sewer District - Development Engineering Section
31623 - 1st Ave S * PO Box 4249 0 Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: ® Building Permit -SFR (56) ❑ Building Permit -MFR ❑ Building Permit -Other
❑ Subdivision ❑ Short Subdivision ❑ Binding Site Plan
❑ Rezone ❑ Boundary Line Adjustment
❑ Other (specify/describe)
Tax Parcel Number(s): TBD (orig. 3021049020 3021049021 3021049058 3021049082) Site Address: Multiple
Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: H=13
Applicant's Name: Lennar NW. Inc.
WATER SYSTEM INFORMATION
1. ® Water service can be provided by service connections to a new a! diameter water main that is approximately 10+/- to
185+/- feet from the plat lots.
2. ❑ Water service for the site will require an Improvement to Lakehaven's water distribution system of:
❑ a. feet of " diameter water main to reach the site; and/or
❑ b. The construction of a water distribution system on the site; and/or
❑ c. A major portion of Lakehaven's comprehensive water system plan would need to be implemented and/or
constructed; and/or
❑ d. Other (describe):
3. ® a. The existing water system is in conformance with Lakehaven's Comprehensive Water System Plan.
❑ b. The existing water system is not in conformance with Lakehaven's Comprehensive Water System Plan and an
Amendment to this Plan will be required. This may cause a delay in Issuance of land use approvals or permits.
4. ® a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted
Boundary Review Board approval for extension of water service outside of Lakehaven's water service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
5. Water service Is subject to:
® a. Payment of connection charges (to be determined by Lakehaven);
® b. Proof or reservation of easement(s) as required by Lakehaven;
® c. Other: Water Service Connection applications (1/Iotarhe uired.
Comments/special conditions: Associated Develg=r Extension Agreement project 46314010) must be accepted by Lakehaven prior
to activating service connections Service pressure areater than 80 psi indicated for some plat lots some Pressure Reducing Valves
Indicated contact local building official for requirements &/or additional information.
The nearest fire hydrants are approximately 5+/- to 375+/- feet from the plat lots (as shown on map on the back of this page).
System hydraulic model results (FF #57, copy attached), at no less than 20 psi, Indicate that Lakehaven's standard maximum
allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 2.700 GPM (approximate). This flow figure depicts the
theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be
accommodated through water distribution system improvements, contact Lakehaven for additional information.
450 Pressure Zone Est. Meter Elevation(s)-GIS: High 276+/-, Low 248+/- Est. Pressure Range at Meter(s) (psi): 73-87
I hereby certify that the above water system Information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR
Signature: • s A �;9A Date: JG7
Retreat Meadows wtr.docx (Form Update 1/3/17) Page 1 of 2
Yom!
Retreat Meadows wtr.docx (Form Update 1/3/17) Page 2 of 2
FILL RECEIVED
JUL 11 2018
Lakehaven CITY CF FECEEFiAL 1NAY
,Z WATER & SEWER DISTRICT COMMUNITY DEVEL,0PMENT
Lakehaven Water & Sewer District - Development Engineering Section
31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: ® Building Permit -SFR (56) ❑ Building Permit -MFR ❑ Building Permit -Other
❑ Subdivision ❑ Short Subdivision ❑ Binding Site Plan
❑ Rezone ❑ Boundary Line Adjustment
❑ Other (specify/describe)
Tax Parcel Number(s): TBD foria 3021049020 3021049021 3021049058, 3021049082) Site Address: Multiple
Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: H=13
Applicant's Name: Lennar NW. Inc.
SEWEg sYSTEM INFORMATION
Sewer service can be provided by service connections to new 2". 3" or 6" diameter sewer mains that are approximately
5+/- to 150+/- feet from the plat lots and the sewer system has the capacity to serve the proposed land use.
2. ❑ Sewer service for the site will require an improvement to Lakehaven's sanitary sewer system of:
❑ a. feet of " diameter sewer main or trunk to reach the site; and/or
❑ b. The construction of a sanitary sewer collection system on the site; and/or
❑ c. A major portion of Lakehaven's comprehensive wastewater system plan would need to be implemented and/or
constructed; and/or
❑ d. Other (describe):
3. 0 a. The existing sewer system is in conformance with Lakehaven's Comprehensive Wastewater System Plan.
❑ b. The existing sewer system is not in conformance with Lakehaven's Comprehensive Wastewater System Plan and an
Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits.
4. 0 a. The proposed site land use is within the corporate limits of Lakehaven Water & Sewer District, or has been granted
Boundary Review Board approval for extension of sewer service outside of Lakehaven's sewer service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
S. Sewer service is subject to:
® a. Payment of connection charges (to be determined by Lakehaven);
® b. Proof or reservation of easement(s) as required by Lakehaven;
® c. Other: Sewer Service Connection Permit (1/lot) required Private Grinder Pump Agreement (1/lot) required.
Comments/special conditions: Associated Developer Extension Agreement project (#6314010) must be accepted by Lakehaven prior
I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of
signature.
Signature:
Date: !
Retreat Meadows swr.docx (Form Update 1/3/17) Page 1 of 2
d,. R
MOTE: Laketwmn water and Sewer Sews rCectifitate of Availability
District neftwr warrants nor guarartees Plat of Retrelttitetit Meadows
accuracy of any facilityirdormation 0 200.
provided. Facility tocattons and conditions
are subject to#%tdverfication.
Feet 3/5/2018: BIA
Retreat Meadows swr.docx (Form Update 1/3/17) Page 2 of 2
�t
+
3021049125
11 :
55
12
3021049118
=
54 53. 5
3021049164
13
14
358TH ST
15
43
46,147 47 :
3021049156
3021049121
16
17
42
S
358�N PPS
•�
4Q
• y
4
3021049004
q
18 3
39
` E
. to
3
�35
34
3021049126
gag
3021049157
21, il,
SW 359TH
. ■
.■■■ ■
■r■■if
�4
25 27
2$
3023
3021049092
c„
3021049013 •■■■■■■■■■�■■■■r■■�rr ws`nrrrrr■.■■.r
■@■■rrrr■r■r■tr■ 04
MOTE: Laketwmn water and Sewer Sews rCectifitate of Availability
District neftwr warrants nor guarartees Plat of Retrelttitetit Meadows
accuracy of any facilityirdormation 0 200.
provided. Facility tocattons and conditions
are subject to#%tdverfication.
Feet 3/5/2018: BIA
Retreat Meadows swr.docx (Form Update 1/3/17) Page 2 of 2
LAKE -HAVEN UTILITY DISTRICT
Hydraulic Model Fire Flow Estimate
Request/Reporting Form
NOTE:
This fire flow rate will cause velocities in excess of 10 f/s
within the water distribution system. A fire flow rate less
than 2700 gpm will maintain flow velocities below 10 f/s.
There is no guarantee that the Hydraulic Model results will
represent actual system performance. Model results depict
the theoretical performance of the system under high demand
conditions. Field measurements should always be obtained for
design purposes.
"- ILA
t--
W
W
WATER SERVICE
z
SS--� RO
SS STUB
VALVE zDj I
INSTALL SILT FENCE �I r[14'
AS SHOWN i2'x10' PERFORATED PIPECONNECTION TRENCH PER
2016 KC SWDM FIGURE
C.2.11.A APPROX
1. FINISHED GRADE TO SLOPE AWAY NOT
LESS THAN 1:12 FOR A MINIMUM OF
6—FT OR TO PROPERTY LINE ADJACENT
TO FOUNDATION AND SHALL START
BELOW THE BOTTOMS OF ALL
FOUNDATION VENTS, PROVIDE
ADDITIONAL SOIL AS REQUIRED TO
CREATE DRAINAGE AWAY FROM
STRUCTURES ALONG PROPERTY LINE
BETWEEN STRUCTURES.
2. ANY PORTIONS OF STRUCTURES WITH
LESS THAN 10—FEET OF SEPARATION
SHALL BE FIRE RATED.
3, INSTALL 8" OF TOPSOIL WITH 4" OF
COMPOST WORKED INTO THE TOPSOIL.
THIS WOULD NEED TO BE SPREAD
OVER THE ENTIRE SITE, WHERE LAWN
AND OTHER LANDSCAPING WOULD BE
INSTALLED BY THE BUILDER OR FUTURE
HOMEOWNER.
CTOR r z
CATS 'SD-
I
SIDEWAI LK
FIRE HYDRANT
SEWER
GRINDER
PUMP
.............
23.28'
aesqnea
Scale: �G14Aj ems 18215 72ND AVENUE SOUTH
Ora" DBRIGGS kafi2anta! Q"�, � KENT, WA 98032
474 , � (425)251-6222
=ZD
Checked BMS (425)251-8782 FAX
Verbcai o '
4C58'
LOT 53
N01*57'56"E 148,001-T'
RCH
>DCO
LOT 52
iD STUB
PROPOSED SINGLE
FAMILY RESIDENCE
_................. 26
iv
UILDING
" m
FOOTPRINT
�NO1'27'33"E 147.56' P
PLAT BOUNDARY-
51.91'
72,76'
ROCKERY
For:
LENNAR NORTHWEST INC.
33455 6TH AVENUE SOUTH, UNIT 1—B
FEDERAL WAY, WA 98003
(253) 590-2205
Title:
I...OT 55
Y
�z
BUILDING 5E(6ACK5:
G4R4GE: 20' SIDE: 5' REFR 10'
RECEIVED
.11.1 1 1 2018
CITY = EDE',PAI ''wAy
ce,MMUN TY DEVELOPMENCf
Im
LOT ADDRESS:
776 SW 358TH STREET
FEDERAL WAY, WA
LOT SIZE = 7,479 SF
TOTAL IMPERVIOUS: 2,997 SF (40.1%)
ROOF: 2,418 SF
DRIVEWAY: 392 SF
WALKWAY: 85 SF
PATIO: 102 SF
C AQ m
TCE =INSTALL TEMP. CONST. ENTRANCE
-+ Oar
rn s— A �;
CPCrn�
TSS ]=INSTALL TEMP. SOIL STOCKPILE
HOUSE PLAN No. 3264`00
Job Number
RETREAT MEADOWS
18221
mco
RESIDENTIAL SITE PLAN
SUBDIVISION LOT-52
Sheet
t"rn
PARCEL NO. TBD
1 or
FlIe:P:\180DOs\18221\lots\18221—Retreat Meadows—Lot.dnq Dote/11me:4/9/2018 10:18 At DBRIGGS