Loading...
18-103056City of Federal way Community Development Dept 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835.2607 Fax (253) 836.2609 x Building - Single Family FILE Permit #:18 -103056 -00 -SF Inspection Request Line: (253) 835-3050 Project Name: RETREAT MEADOWS LOT 52 Project Address: 176 SW 358TH ST Parcel Number: 724290 0520 Project Description: NEW - Construction of a 2 -story, 3264 square foot single family residence with a 60 square foot covered entry and a 420 square foot deck, including plumbing and mechanical. *** 4 bedrooms; $350,000 estimated selling price*** Owner Applicant Contractor Lender LENNAR NORTHWEST INC JULIE FISONLENNAR LENNAR NORTHWEST INC 0 33455 6TH AVE S SUITE 1-B NORTHWEST INC 33455 6TH AVE S SUITE 1-B No FEDERAL WAY WA 98003 33455 6TH AVE S UNIT 1-B FEDERAL WAY WA 98003 0 New / Additional Sq. Feet - Garage ........................ FEDERAL WAY WA 98003 Mechanical to be Included?..................................... Yes Census Category: 101- New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: 0 Floor Area (sq. ft.) 0.00 Additional Permit information New/ Additional Sq. Feet -1st Floor ..................... 1645 New / Additional Sq. Feet - 2nd Floor.................... 1619 New / Additional Sq. Feet - 3rd Floor ..................... 0 Occupancy #1 - Area (Sq. Feet).............................. 0 New / Additional Sq. Feet - Basement .................... 0 Basic Plan? ........................................................... No Occupancy #1 - Construction Type ......................... Type V - B New / Additional Sq. Feet - Deck ........................... 0 New / Additional Sq. Feet - Garage ........................ 420 Mechanical to be Included?..................................... Yes Plumbing Work Valuation? ..................................... 20000 Mechanical Work Valuation?.................................. 10000 Number of Stories ................................................... 2 New / Additional Sq. Feet - Other........................... 60 Plumbing to be Included? .................. ................ ...... Yes New / Additional Sq. Feet - Total........................... 3744 Will Certificate of Occupancy be Issued? ............... Yes Occupancy #1 - Use................................................ Residence (I or 2 family) Comprehensive Plan Designation ........................... SF - High -Density Zoning Designation ................................................. RS 7.2 Residential Ducting 1 Fans 5 Fireplace Inserts 2 Furnaces I Gas Piping 5 Gas Pipe Outlets 5 Hot Water Tanks 1 Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 5 Showers 1 Sinks 1 Water Closets 3 Hose Bibbs 2 11 ., PERMIT EXPIRES Monday, 21 January, 2019 Permit Issued on Wednesday, July 25, 2018 I hereby certify that the above and the occupancy and the Owner or agent: d" V ♦ a mation is correct and that the construction on the above described property will be in accordance with the laws, rules and regulations of the State of Nashington and the City of Federal Way. City of Federal Way Certificate of Occupancy Date: L 2T-/9 This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed bV City staff. Tenant Name: RETREAT MEADOWS LOT 52 Address: 176 SW 358TH ST Includes: #1 #2 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: 0.00 Floor Area (sq. ft.) 0.00 Owner Name: LENNAR NORTHWEST INC Owner Address: 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 uilding Official Permit # 18 -103056 -00 -SF #3 #4 Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/ occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. crry w Federal Way PERMIT #: Project: THIS CARD IS TO REMAIN ON-SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 18103056 00 Address: 176 SW 358TH ST LENNAR NORTHWEST INC FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. El SWM Precon Site Mtg (4400) 0 Initial Erosion Control (4365) 0 Footings/Setback (4110) Approved Illy To be done PRIOR to breaking ground Approved to place concrete By Date ByQ-C Date R. z0 Date By Date ® Foundation Wall (4115) ® Drainage/Downspout (4040) ® Plumbing Groundwork (4190) Approval to place concrete Approved to backfill Approved to cover By Date ByQ-C Date R. z0 Date ( 6 By Date I By Date By El Slab/Concrete Floor (4255) ® Underfloor Framing (4285) Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By hfi Date /d i 5 By Date o Shear Wang (4245) 0 Roof Sheathing (4220)0 Rough Plumbing (4230) Approved to install siding Approved to instal roofing Approved By Date 11 Z By t)3 Date �l By Date 13 By Mechanical Rough -in (4165) Approved Date lk-4,Datey 4 Gas Piping (4125) Approved to release Lest �- ® 1By Fire/Draft Stops (4095) Approved Date ^ 1 ® Interim Erosion Control (4370) Approved Prior to scheduling a Framing Electrical, PlmaNng & Mechanical Roagb4n and Fire/Draft Stop inspections mit be signed - 0 1By Framing (4120) Approved to iasul to By Date oRand approved. IBC 109.3.4 Date 1 is Insulation (4150) 0 Gypsum Wallboard Nailing (4130) 99 Final Erosion Control (4375) Approved to install wallboard Approved to install mud dt tape Approval By Date - 1, By C Date _3 By Date El Final - Mechanical (4065) 2 Final - Plumbing (4075) Final - Building (4050) Approved Approved Approval By P {2 Date 1 - 2 4 1 Q By C U Date 1. 4 1 o,1By 2 _ Date 1 �- ZR '1 L' 0 - k1,L_ k*u, 016 Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date I By Date By Date 3264 JUL 1 1 2018 CITY OF FEDERAL wAYPERMIT APPLICATION CITY OF �� C)OMMUNI7Y DEVELOPMENTFederal Way PERMIT NUMBER _ 0TARGET DATE �J I - � - - SITE ADDRESS SUITE/UNIT M 176 SW 358th St PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL 4 $ 175,000.00 RS7 2 7 2 4 2 9 0_ 0 5 2 0 TYPE OF PERMIT MBUILDING M PLUMBING VMECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Retreat Meadows Build 2 story SFR 3264 Sq Ft. Lot 52 PROJECT DESCRIPTION Detailed description of work to be included on this permit only . NAME Lennar Northwest Inc. PRIMARY PHONE 253-590-2213 PROPERTY OWNER MAILING ADD S 33455 6ti Ave S., Unit 1-B E-MAIL julie.fison@lennar.com c`TTederal Way sTWA ZIP 98003 NAME Lennar Northwest Inc. PH253-590-2213 MAILING ADDRESS - 33455 6th Ave S., Unit 1-B E-MAIL 'ulie.fison@lennar.com CONTRACTOR °ITYFederal Way ST WA V V ZIP 98003 FAX WA STATE CONTRACTOR'S LIbENSE Y EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE M CC LENNNANI893QG 11/ 7 /2019 NAME Julie Fison PRIMARY PHONE 253-590-2213 APPLICANT MAILING ADDRESS 33455 6th Ave S., Unit 1-B E , )ulie. fison@lennar.com CITY Federal Way STATE WA 21P98003 FAX NAME P 253)P590-2213 PROJECT CONTACT Julie Fisori MAILING ADDRESS 33455 6th Ave S., Unit 1-B E-MAIL julie.fison@lennar.com (The individual to receive and respond to all correspondence CITfederal Way STATE Z198003 FAX concerning this application) PROJECT FINANCING NA!"tennar Northwest Inc. ®—s tlsl �N es?o--- When value is $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CITY, STATE, ZIP 33455 6th. Ave S., Unit 1-B Federal Way, WA 98003 PHONE (253) 590-2213 I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the irVormation supplied to the city as apart of this application. SIGNATURE: gldoit. DATE 7/9/2018 PRINT NAME: Julie Flson Bulletin #100 — February 22, 2016 Page 1 of 2 k:\Handouts\Permit Application AL MECHANICAL PERMIT Indicate how many of each typ AIR HANDLING UNITS AIR CONDITIONER BOILERS COMPRESSORS 1 DUCTING PLUMBING PERMIT Indicate how many of each type o re to be installed or relocated as part of this project. Do not include existing res to remain. BATHTUBS )or Tub/Show rcombn) LAVS (Ha dSinks) _3 TOILETS WATER PIPING 1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS 1 SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS 1 SINKS )Kitchen/Unlit WATER HEATERS (Eiectri,) 7— HOSE BIBBS SUMPS �_ WASHING MACHINES 16 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS N/A Lakehaven Utilty District # of N/A Square Feet a EXISTING/PREVIOUS USE LOT SIZE (In Square Feet( EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Vacant 7,479 ❑ Yes M No ❑ Yes IX No COMMERCIAL — NEW ADDITION AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet a Stories 77777777 NEW BUILDING • - - ADDITION COMMERCIAL — REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet a Stories TOTAL Bd[iptxG TENANT AREA ONLY PROJECT AREA ONLY . Bulletin #100 —February 22, 2016 Page 2 of 2 k:\Handouts\Permit Application RECEIVED FILE JUL 11 2018 t4�p Lakehaven GM "DE'V L PME WATER &SEWER DISTRICT GOMMUNIT'(DE1't:LOPMENT Lakehaven Water & Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 0 Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ® Building Permit -SFR (56) ❑ Building Permit -MFR ❑ Building Permit -Other ❑ Subdivision ❑ Short Subdivision ❑ Binding Site Plan ❑ Rezone ❑ Boundary Line Adjustment ❑ Other (specify/describe) Tax Parcel Number(s): TBD (orig. 3021049020 3021049021 3021049058 3021049082) Site Address: Multiple Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: H=13 Applicant's Name: Lennar NW. Inc. WATER SYSTEM INFORMATION 1. ® Water service can be provided by service connections to a new a! diameter water main that is approximately 10+/- to 185+/- feet from the plat lots. 2. ❑ Water service for the site will require an Improvement to Lakehaven's water distribution system of: ❑ a. feet of " diameter water main to reach the site; and/or ❑ b. The construction of a water distribution system on the site; and/or ❑ c. A major portion of Lakehaven's comprehensive water system plan would need to be implemented and/or constructed; and/or ❑ d. Other (describe): 3. ® a. The existing water system is in conformance with Lakehaven's Comprehensive Water System Plan. ❑ b. The existing water system is not in conformance with Lakehaven's Comprehensive Water System Plan and an Amendment to this Plan will be required. This may cause a delay in Issuance of land use approvals or permits. 4. ® a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of water service outside of Lakehaven's water service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Water service Is subject to: ® a. Payment of connection charges (to be determined by Lakehaven); ® b. Proof or reservation of easement(s) as required by Lakehaven; ® c. Other: Water Service Connection applications (1/Iotarhe uired. Comments/special conditions: Associated Develg=r Extension Agreement project 46314010) must be accepted by Lakehaven prior to activating service connections Service pressure areater than 80 psi indicated for some plat lots some Pressure Reducing Valves Indicated contact local building official for requirements &/or additional information. The nearest fire hydrants are approximately 5+/- to 375+/- feet from the plat lots (as shown on map on the back of this page). System hydraulic model results (FF #57, copy attached), at no less than 20 psi, Indicate that Lakehaven's standard maximum allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 2.700 GPM (approximate). This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water distribution system improvements, contact Lakehaven for additional information. 450 Pressure Zone Est. Meter Elevation(s)-GIS: High 276+/-, Low 248+/- Est. Pressure Range at Meter(s) (psi): 73-87 I hereby certify that the above water system Information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR Signature: • s A �;9A Date: JG7 Retreat Meadows wtr.docx (Form Update 1/3/17) Page 1 of 2 Yom! Retreat Meadows wtr.docx (Form Update 1/3/17) Page 2 of 2 FILL RECEIVED JUL 11 2018 Lakehaven CITY CF FECEEFiAL 1NAY ,Z WATER & SEWER DISTRICT COMMUNITY DEVEL,0PMENT Lakehaven Water & Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ® Building Permit -SFR (56) ❑ Building Permit -MFR ❑ Building Permit -Other ❑ Subdivision ❑ Short Subdivision ❑ Binding Site Plan ❑ Rezone ❑ Boundary Line Adjustment ❑ Other (specify/describe) Tax Parcel Number(s): TBD foria 3021049020 3021049021 3021049058, 3021049082) Site Address: Multiple Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: H=13 Applicant's Name: Lennar NW. Inc. SEWEg sYSTEM INFORMATION Sewer service can be provided by service connections to new 2". 3" or 6" diameter sewer mains that are approximately 5+/- to 150+/- feet from the plat lots and the sewer system has the capacity to serve the proposed land use. 2. ❑ Sewer service for the site will require an improvement to Lakehaven's sanitary sewer system of: ❑ a. feet of " diameter sewer main or trunk to reach the site; and/or ❑ b. The construction of a sanitary sewer collection system on the site; and/or ❑ c. A major portion of Lakehaven's comprehensive wastewater system plan would need to be implemented and/or constructed; and/or ❑ d. Other (describe): 3. 0 a. The existing sewer system is in conformance with Lakehaven's Comprehensive Wastewater System Plan. ❑ b. The existing sewer system is not in conformance with Lakehaven's Comprehensive Wastewater System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. 0 a. The proposed site land use is within the corporate limits of Lakehaven Water & Sewer District, or has been granted Boundary Review Board approval for extension of sewer service outside of Lakehaven's sewer service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. S. Sewer service is subject to: ® a. Payment of connection charges (to be determined by Lakehaven); ® b. Proof or reservation of easement(s) as required by Lakehaven; ® c. Other: Sewer Service Connection Permit (1/lot) required Private Grinder Pump Agreement (1/lot) required. Comments/special conditions: Associated Developer Extension Agreement project (#6314010) must be accepted by Lakehaven prior I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of signature. Signature: Date: ! Retreat Meadows swr.docx (Form Update 1/3/17) Page 1 of 2 d,. R MOTE: Laketwmn water and Sewer Sews rCectifitate of Availability District neftwr warrants nor guarartees Plat of Retrelttitetit Meadows accuracy of any facilityirdormation 0 200. provided. Facility tocattons and conditions are subject to#%tdverfication. Feet 3/5/2018: BIA Retreat Meadows swr.docx (Form Update 1/3/17) Page 2 of 2 �t + 3021049125 11 : 55 12 3021049118 = 54 53. 5 3021049164 13 14 358TH ST 15 43 46,147 47 : 3021049156 3021049121 16 17 42 S 358�N PPS •� 4Q • y 4 3021049004 q 18 3 39 ` E . to 3 �35 34 3021049126 gag 3021049157 21, il, SW 359TH . ■ .■■■ ■ ■r■■if �4 25 27 2$ 3023 3021049092 c„ 3021049013 •■■■■■■■■■�■■■■r■■�rr ws`nrrrrr■.■■.r ■@■■rrrr■r■r■tr■ 04 MOTE: Laketwmn water and Sewer Sews rCectifitate of Availability District neftwr warrants nor guarartees Plat of Retrelttitetit Meadows accuracy of any facilityirdormation 0 200. provided. Facility tocattons and conditions are subject to#%tdverfication. Feet 3/5/2018: BIA Retreat Meadows swr.docx (Form Update 1/3/17) Page 2 of 2 LAKE -HAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form NOTE: This fire flow rate will cause velocities in excess of 10 f/s within the water distribution system. A fire flow rate less than 2700 gpm will maintain flow velocities below 10 f/s. There is no guarantee that the Hydraulic Model results will represent actual system performance. Model results depict the theoretical performance of the system under high demand conditions. Field measurements should always be obtained for design purposes. "- ILA t-- W W WATER SERVICE z SS--� RO SS STUB VALVE zDj I INSTALL SILT FENCE �I r[14' AS SHOWN i2'x10' PERFORATED PIPECONNECTION TRENCH PER 2016 KC SWDM FIGURE C.2.11.A APPROX 1. FINISHED GRADE TO SLOPE AWAY NOT LESS THAN 1:12 FOR A MINIMUM OF 6—FT OR TO PROPERTY LINE ADJACENT TO FOUNDATION AND SHALL START BELOW THE BOTTOMS OF ALL FOUNDATION VENTS, PROVIDE ADDITIONAL SOIL AS REQUIRED TO CREATE DRAINAGE AWAY FROM STRUCTURES ALONG PROPERTY LINE BETWEEN STRUCTURES. 2. ANY PORTIONS OF STRUCTURES WITH LESS THAN 10—FEET OF SEPARATION SHALL BE FIRE RATED. 3, INSTALL 8" OF TOPSOIL WITH 4" OF COMPOST WORKED INTO THE TOPSOIL. THIS WOULD NEED TO BE SPREAD OVER THE ENTIRE SITE, WHERE LAWN AND OTHER LANDSCAPING WOULD BE INSTALLED BY THE BUILDER OR FUTURE HOMEOWNER. CTOR r z CATS 'SD- I SIDEWAI LK FIRE HYDRANT SEWER GRINDER PUMP ............. 23.28' aesqnea Scale: �G14Aj ems 18215 72ND AVENUE SOUTH Ora" DBRIGGS kafi2anta! Q"�, � KENT, WA 98032 474 , � (425)251-6222 =ZD Checked BMS (425)251-8782 FAX Verbcai o ' 4C58' LOT 53 N01*57'56"E 148,001-T' RCH >DCO LOT 52 iD STUB PROPOSED SINGLE FAMILY RESIDENCE _................. 26 iv UILDING " m FOOTPRINT �NO1'27'33"E 147.56' P PLAT BOUNDARY- 51.91' 72,76' ROCKERY For: LENNAR NORTHWEST INC. 33455 6TH AVENUE SOUTH, UNIT 1—B FEDERAL WAY, WA 98003 (253) 590-2205 Title: I...OT 55 Y �z BUILDING 5E(6ACK5: G4R4GE: 20' SIDE: 5' REFR 10' RECEIVED .11.1 1 1 2018 CITY = EDE',PAI ''wAy ce,MMUN TY DEVELOPMENCf Im LOT ADDRESS: 776 SW 358TH STREET FEDERAL WAY, WA LOT SIZE = 7,479 SF TOTAL IMPERVIOUS: 2,997 SF (40.1%) ROOF: 2,418 SF DRIVEWAY: 392 SF WALKWAY: 85 SF PATIO: 102 SF C AQ m TCE =INSTALL TEMP. CONST. ENTRANCE -+ Oar rn s— A �; CPCrn� TSS ]=INSTALL TEMP. SOIL STOCKPILE HOUSE PLAN No. 3264`00 Job Number RETREAT MEADOWS 18221 mco RESIDENTIAL SITE PLAN SUBDIVISION LOT-52 Sheet t"rn PARCEL NO. TBD 1 or FlIe:P:\180DOs\18221\lots\18221—Retreat Meadows—Lot.dnq Dote/11me:4/9/2018 10:18 At DBRIGGS