18-105010City of Federal Way
Community Development Dept.
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Project Name: EUROPEAN WAX CENTER
Project Address: 1706 S 320TH ST
Building - Commercial
Permit #:18 -105010 -00 -CO
Inspection Request Line: (253) 835-3050
Parcel Number: 092104 9208
Project Description: TI - Tenant improvements including new partition walls, doors, ceiling and finishes and adding
2 restrooms. Includes plumbing and mechanical.
Owner
Applicant
Contractor
Lender
HARSCH INVESTMENT
THOMAS BOUFFARD
D A BENTLEY CONSTRUCTION
TENANT IS LENDER
PROPERTIES
1822 MAIN ST
LLC
1430 SW BROADWAY SUITE 100
HUNTINGTON BEACH CA 92648
1079 NE COXLEY DR
PORTLAND OR 97201
VANCOUVER WA 98662
Census Category: 437 - Commercial alt / add / conversion
Includes: #1 #2 #3 #4
Occupancy Class:
Construction Type:
Occupancy Load:
Floor Area (sq. ft.) 0.00 0.00 1 0.00 0.00
Additional Permit Information
Mechanical to be Included? .....................................
Yes
Mechanical Work Valuation? ..................................
35000
Is this an Online or O.T.C. application? ..................
Yes
Plumbing to be Included? ........................................
Yes
Total Valuation: 120,000.00
Ducting 1 Fans
Lavatories 2 Sinks
Water Heaters 2
Plumbing Work Valuation? ..................................... 12500
Number of Stories ................................................... I
Permit for Building Shell Only? .............................. No
2
1 Water Closets
PERMIT EXPIRES Wednesday, l May, 2019
Permit Issued on Friday, November 2, 2018
2
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accords with the laws, rules and regulations of the State of
Washin on a Ci o Federal Way.
Owner or agent. Date: i
CITY OF
Federal Way
THIS CARD IS TO REMAIN ON-SITE
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 18 105010 00 Address: 1706 S 320TH ST Unit G
Project: HARSCH INVESTMENT PROPERTI FEDERAL WAY WA 98003
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
®
Initial Erosion Control (4365)
®
Footings/Setback (4110)
El
Re -steel (4215)
Approved
To be done PRIOR to breaking ground
Approved to place concrete
By AfJ Date 1 p
Approved to place concrete or grout
By
Date
By
Date
By
Date
E.
Plumbing Groundwork (4190)
®
Slab/Concrete Floor (4255)
El
Underfloor Framing (4285)
Approved
Approved to cover
Approved to place concrete
By AfJ Date 1 p
Approved to sheath floor
By
Date - i 01
By
Date
By
Date
0 Floor Sheathing (4105)
El Rough Plumbing (4230)
® Mechanical Rough -in (4165)
Approved to install flooring
Approved
Approved
Approved
Approved to release test
By Date
By AfJ Date 1 p
By Date I
El
Gas Piping (4125)
El
Fire/Draft Stops (4095)
El
Interim Erosion Control (4370)
Approved
Approved to release test
Approved
By
Approved
By
Date
By
Date
By
Date
11
Prior to scheduling a Framing inspection; 9's Framing (4120) Insulation (4150)
Electrical, Plumbing & Mechanical Rough -in Approved to insulate Approved to install wallboard
and Fire/Draft Stop inspections must be signed -
off and approved. IBC 109.3.4 By A, Date 11 15 f By Date
0
Gypsum Wallboard Nailing (4130)
El
Suspended Ceiling Grid (4265)
El
Final - S K F & R (4060)
Approved
Approved to install mud & tape
Approved to drop tile
By
Approved
By
Date
By
I.,:, Date ")_- ('
By
Date
El
Final - Planning
Is
Final Erosion Control (4375)
Final - Building (4050)
Final - Mechanical (4065)
Approved
Approved
Approved
By
Approved
By
Date
By
Date
By
Date
El
Final - Plumbing (4075)
22
Final - Building (4050)
Approved
Right of Way
Approved
By
Date 2- -7
Approved
By
Date J13
ti's L - t✓ ��
Rough Electrical
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
By
Date
By
Date
ti
RECEIVE
C17V OF A� OCT 23 2021 PERMIT APPLICATION
Federal Way CITY OF FEDE4L 1'AY PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325
253-835-2607 + FAX 253-835-2609 +)ermitcentelfukitvoffederalwav.com
GOMMUNITY DEVELOPMEI
PERMIT NUMBER _ S0 � / l/ / 1 6 _ / 0
G �/ .cam TARGET DATE
SITE ADDRESS
SUITE/UNIT #
PROTECT VALUATION
$#
ZONING
� �
ASSESSOR'S TAIL/PARCEL
Cl � a o f?
« 000
_v -
TYPE OF PERMIT
AKBUILDING ted PLUMBING W MECIiANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
-cgF+IhtJ'r I M rAIEyAI�i4T V��WVAJ WAY �V
�� '"'TT
k •� /
til,moi
PROJECT DESCRIPTION
Detailed description of work to
•'
r49 (,#A "47, 09,17
L G vt O
be included on this permit only
4 x) vie- s
NAME
t -F A 2 5 car} IK WW—r t
PRIMARY PHONE
03 -r7-1 dl -7G
PROPERTY OWNER
MAILING ADDRESS
MAIL
CITY
STATE I
ZIP
NAM 4/ A (0" �
epSNE 4r, Sr Z
MAILING ADDRESS
O -1.1 l'i9XL1E Y �� •
H_-
4 -A ti LrpF t'�
CONTRACTOR
FAR
CITY
lOuv�•
a ATR
�r
ZIP
Gl 'iG
WA STATE CONTRACTOR'S LICENSE #
e G P
EXPIRATION DATE
o,ie,+i2a
FEDERAL WAY BUSINESS LICENSE #
NAME
Nq jkc V5 OV
PRIMARY PHONE
o-7 7 Z' BJS�
MAILING ADDRESS
j 0 2 2 /M," V S'r
MAIL
��•�G�3
APPLICANT
CITY
G1�Tti�'G oti1 I�/sr9
STATB
GfJ
ZIP
�LG4'�
FAX
�'".
AAM �/ I
•�"�
PRIMARY PHONE
'7�I %SG
PROJECT CONTACT
soplh!�'
7
MAILING ADDRESS
1 gZy PkAltj
E-MAIL
•�s/Arrt' Aemlve
(The individual to receive and
respond to all correspondence
CITY
04.4-r,46
STATE
ZIP
FAX ling'. AO
concerning this application)
PROJECT FINANCING
NAME
❑ OWNER -FINANCED
When value is $5, 000 or more
(RCW 19.27.095)
MAILING ADDRESS, CITY, STATE, ZIP
PHONE
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claiml, which may be made by any person, including the undersigned, and filed against the city,
but only where such claim ari of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied tot ity as a is application.
SIGNATURE: / DATE G
, /
PRINT NAME: 10� �v
Bulletin #100 — January 29, 2016 Page I of 2 kA Iandouts\Permit Application
7-1
Loi
0
Oil
I
It
MECHANICAL PERMIT
Indicate how many of each e o
tore to be installed or relocated as
part of this project. Do not include existiftg fixtures to remain.
AIR HANDLING UNITS
FANS
GAS PIPE OUTLETS OTHER (Describe)
AIR CONDITIONER
FIREPLACE INSERTS
HOODS (commem �t
BOILERS
FURNACES
HOT WATER TANKS (Gass
_ COMPRESSORS
GAS LOG SETS
REFRIGERATION SYST
( DUCTING
GAS PIPING
WOODSTOVES
PLUMBING PERMIT
Indicate how many o each type
of fixture to be installed or relocatPrl as nart of this project. Do not include existingfwtures to remain.
BATHTUBS (,,T•,b/sh—rCombo) 'j'+1) ALAVS (Hand Sinks
q TOILETS WATER PIPING
DISHWASHERS
RAINWATER SYSTEMS
URINALS OTHER (Describe)
DRAINS�
SHOWERS
VACUUM BREAKERS
DRINKING FOUNTAINS
�
_L SINKS (K;mhen/uahtyi
Z WATER HEATERS (Eteocdo
HOSE BIBBS
SUMPS
WASHING MACHINES TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY?
WATER PURVEYOR
SEWERS/EW�E�R PURVEYOR
VALUE OF EXISTING IMPROVEMENTS
# of
Stories
(yI r4
v.1 i-1'��
1
$
EXISTING/ PREVIOUS USE
LOT SIZE (In Square Feet)
EXISTING FIRE SPRINKLER SYSTEM?
PROPOSED FIRE SUPPRESSION SYSTEM?
❑ Yes V No
[]Yes r"1140
RESIDENTIAL - NEW OR ADDITION '
AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
....._.................................................................................................................
BASEMENT
........................................................................................................................
FIRST FLOOR (or Mobile Home)
........................................................................................................................
SECOND FLOOR
........................................................................................................................
COVERED ENTRY
........................................................................................................................
DECK
........................................................................................................................
GARAGE ❑ CARPORT ❑
.......................................................................................................................
OTHER (describe)
._..........................................................................................................
Area Totals EXISTING PROPOSED TOTAL.
**NEW HOMES ONLY**
ESTIMATED SELLING PRICE $ # OF BEDROOMS
COMMERCIAL — NEW/ADDITION
AREA DESCRIPTION
Area in
Square Feet
Occupancy Group(s)
Construction
# of
Stories
Additional Information
NEW BUILDING
ADDITION
COMMERCIAL—REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION
Area in
Square Feet
s
Occupancy Group()
Construction
# of
Stories
Additional Information
TOTAL BUILDING
TENANT AREA ONLY
J 4 D
v
1
PROTECT AREA ONLY
Bulletin #100 — January 29, 2016 Page 2 of 2 k:�Handouts\Permit Application
European Wax Center
Federal Way,WA
AIR BALANCE / COMMISSIONING REPORT
Test Equipment Used:Dwyer VT-140 Thermo Anemometer Ft/Mm Measurement +/-(2%Accuracy)
RTU-1
Zones 1 thru 8 exam and restrooms 9 @ 590 Ft/ Min @ 100 cfm
Zone 8 hallway 2 @ 600 Ft/ Min @ 350 cfm
Zone 9 lobby 3 @ 580 Ft/ Min @ 200 cfm
Zone 10 1 @ 590 Ft/Min @ 300 cfm
Zone 11 1 @ 600 Ft/Min @ 300 cfm
RTU-1 Total CFM = 2,800
Total space supply air 2,800 CFM/Total outside air @ min 20% =560 CFM/Total space
Heating/cooling 7-Tons
Field notes: Systems are all controlled by a Honeywell Vari-Zone with?-day programmable
thermostat.
K&D Mechanical,Inc.
335301st Way south Suite 102
Federal Way,WA 98003
James Dahlen I President 12-7-2019
— JO5 \ O