19-100570IL
Electrical
City nityDe Federal p Wry Permit #:19 -100570 -00 -EL
Community Development Dept.
33325 8th Ave S FILE
Federal Way, WA 98003 Inspection Request Line: (253) 835-3050
Ph: (253) 8352607 Fax. (253) 835-2609
Project Name: MCDONALDS
Project Address: 2302 S 320TH ST Parcel Number: 092104 9272
Project Description: Remodel restroom, dining,menu boards, front counter, self order kiosks, drink station, lighting
and power. Installing 4 chases for the POS systems at the counter; 12 circuits total being
altered - including 4 lighting and 8 for equipment.
Additional Permit Information
Is this an Online or O.T.C. application? .................. Yes
Circuits - Commercial 12 Low Voltage - Other (Commel 4
PERMIT EXPIRES Tuesday, 4 February, 2020
Permit Issued on Monday, February 4, 2019
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: Date:
Owner
Applicant
Contractor
MCDONALDS
ROBERT CLARKR J CLARK LLC
R J CLARK LLC
2302 S 320TH ST
19424 SE 67TH AVE
RJCLAL*981MA (7/1/20)
FEDERAL WAY WA 98003
SNOHOMISH WA 98296
19424 67TH AVE SE
SNOHOWSH WA 98296
Additional Permit Information
Is this an Online or O.T.C. application? .................. Yes
Circuits - Commercial 12 Low Voltage - Other (Commel 4
PERMIT EXPIRES Tuesday, 4 February, 2020
Permit Issued on Monday, February 4, 2019
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: Date:
4• �+
:4
THIS CARD IS TO REMAIN ON-SITE
MY or 1/
Construction Inspection Record
Federal Way INSPECTION REQUESTS: (253) 835-3050
PERAW #: 1910057000 Address: 2302 S 320TH ST
Project: MCDONALDS FEDERAL WAY WA 98003-5418
Scheduled inspections may be failed if this card is not on-6te. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check withour
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. y mor if
El
UFER Ground (4295)
®
0
Ditch cover (4030)
El
S1ab/Conerete Floor (4255)
App1OVed
Approved
Approved
1BY
Approved
By
Approved to place concrete
By
Date
By
By
Date
l
Date
®
Pool Bonding (4195)
®
Temporary Power (4275)
®
Service (4235)
0
App1OVed
Approved
1BY
Approved
By
Date
By
Date
By
Date
❑
Feeders/Sub-panels (4045)
®
Rough Electrical (4225)
0
Ceiling Cover (4020)
0
Approved
Approved
Approved
By
Date
By tj
Date nt ►3,%,
By
Dateis. — ig
Final - Electrical (4055)
Approved
By 6ALr, I Date 3— T-1
Rough Electrical
0
Final Electrical
0
Right of Way
Approved
Approved
Approved
By
Date
By
Date
By