Loading...
14-104877y City of Federal Way Community & Econ. Dev. Services 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: TWIN LAKES APARTMENTS Project Address: 3320 SW 320TH ST t !F 1 Ouilding - NUld #am ly Permit #: 14 -104877 -00 -MF Inspection Request Line: (253) 835-3050 Project Description: REP - Remove existing flat roof and replace with pitched roof Parcel Number: 132103 9072 Owner ARDlicant Contractor Lender TWIN LAKES PLAZA LLC KARL SCHMIDT ARCHITECTURE GREEN HOME CONTRACTORS PO BOX 22485 PLLC LLC SEATTLE WA 98122 2016 MCGILVRA BLVD E GREENHC906CQ (3/12/16) SEATTLE WA 98112 6042 45TH AVE SW SEATTLE WA 98136 Census Category: 437 - Commercial alt / add / conversion Includes: # 1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load- Floor oadFloor Areas . ft. 0 0 0 1 0 Additional Permit Information Mechanical to be Included? .............................No Number of Stories.......................... ............,......2 Permit for Building Shell Only? ............................No Plumbing to be Included? ...................................... No No Fixtures Associated With This Permit 11 CONDITIONS: fire department inspection required prior to building department roof sheeting and framing inspection. PERMIT EXPIRES Sunday, March 22, 2015 Permit Issued on Tuesday, September 23, 2014 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the se will be in accordance with the laws, rules and regulations of the State of Washington and the i of Federal Way. g Owner or agent: Date: r Apartment Building 3320 SW 320th St Federal Way, WA 98023 NAIL 2x4 BLOCKING TO 44 WITH (3) 16d PER BLOCK (TYP) SIMPSON H4 AT EACH TRUSS (TYP.) NUOUS 4x4 PLATE W/ #6x6" SCREWS AT 24" OR 16" O.C. (E) STUD WALL HALAS ENGINEERING 11711 8th Ave. NW Seattle WA 206 362-2707 TRUSS PER MFG. W" NAIL SHEATHING TO 2X4 BLOCKING BLOCKING WITH 8d AX//� @ 6" O.C. -TYP 9 2X4 STUD BOTH SIDES OF EACH TRUSS 2X4 BLOCKING 5/8" PLYWOOD BETWEEN TRUSSES - W/ 8d AT 6" O.C. AT PLYWOOD EDGES APR VED By Date .�•'- v. y `• . 1 TYPICAL TRUSS/ROOF CONNECTION �C�-loo,..«...1 1/2" = 1'-0" >.� Got RECEIVED RECEIVED i 2/24/15 A •�,s ,,,, �' , ,�° FEB 2 6 2015 SK -1a Nv all CITY OF FEDERAL WAY l 1 O ..0 00 ftj 61% 4 r Structural Calculations For Twin Lakes Apartments 3320 SW 320th St. Federal Way, WA 98023 Halas Engineering 11711 8th Ave. NW Seattle Wa 98177 206 362-2707 WIND LOADS Simplified method h = 25.00 ft 0.4H = 10.00 Exposure = B 6.5.6.2 Roof Angle = 18.4 Deg. Basic wind speed = 85 mph Lambda = 1.00 t = 1.0 Kzt = 1.00 fig. 6-2 B C D E F G H Ps30 = -4.2 10.6 -2.3 -13.8 -9.6 -9.6 Ps = -4.2 10.6 -2.3 -13.8 -9.6 -9.6 6.9 A, Ps = 0.00 B, Ps = -4.20 C, Ps = Shear wall Wall load load/ft h h B w B 23.00 lbs/ft 10.0 2.3 1 -633 9.18 6.00 13.80 EOH EOH -7.3 -19.30 -15.1 -7.3 -19.3 -15.1 10.60 D, Ps = -2.30 hD wD 6.00 20.70 a L 10%L 40%h max. 4%Lmin. 3ft Min. 0 7 69.00 6.9 10.0 6.9 0.92 3.0 3.0 0 3 23.00 2.3 10.0 2.3 0.92 3.0 3.0 0 3 23.00 2.3 10.0 2.3 0.92 3.0 3.0 0 7 69.00 6.9 10.0 6.9 0.92 3.0 3.0 Force At Diaphroagm Chord Direction 1 (E -W) Seismic Controls Roof Level Length (ft) Seismic (lb) Wind (lb) (plf) Wall 69 1281 -633 19 2/26/15 Page 1 of 2 37 Ib per truss location USE #6 Screws at 16" or 24 " O.C. i •� ►••'i RECEIVED FEB 2 6 2015 CITY OF FEDERAL WAY CDS h _ Y • f Twin Lakes Apartments SEISMIC LOADS EQUIVELANT LATERAL FORCE PROCEDURE Ss = 1.243 Seismic Design Category = D Fa = 1.003 F = 1.1 R = 6.5 SMI = 0.63 SDI= 0.42 SDs = 0.83 Cs 0.13 I i • Halas Engineering 2/26/15 Page2 of 2 Roof Loads ASCE 7 - 05 roofing 3.0 Ib/sf Sheathing 1.8 Ib/sf USGS Trusses @24 3.0 Ib/sf Tbl. 11.6-1 0.0 Ib/sf soils 12.14.8.1 insl 0.0lb/sf 12.14.8.1 Misc 1.0lb/sf Plywd SW Tbl 12.2-1 subtotal 8.8 Ib/sf Snow 25.0 Ib/sf (2/3)*Fa*S 12.14-11 total 33.8 Ib/sf 12.8.1.1 roof length 69 ft Roof width 16.5 ft Area 1138.5 sf Weight = 10018.8 lbs Seismic load 1281 lbs Laod/ft 18.57 lbs/ft CITY OF Federal Way . THIS CARD IS TO ON-SITE Construction In ectiI Record INSPECTION REQ TS: (253) 835-3050 PERMIT #: 14 -104877 -00 -MF Address: 3320 SW 320TH ST Project: TWIN LAKES PLAZA LLC FEDERAL WAY, WA 98023-2294 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. SWM Precon Site Mtg (4400) E] Drainage/Downspout (4040) Initial Erosion Control (4365) Re -steel (4215) Footings/Setback (4110) Approved to place concrete Approved By To be done prior to breaking ground By Approved to place concrete By Date By Date By Date Foundation Wall (4115) E] Drainage/Downspout (4040) n Re -steel (4215) Approved to place concrete Approved to backfill By Approved to place concrete or grout By Date By Date By Date Date Slab/Concrete Floor (4255) Underfloor Framing (4285) Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By Date By Date Shear Walls (4245) Roof Sheathing (4220) 0 Fire/Draft Stops (4095) Approved to install siding nn Approved to install roofing Approved By Date By Pjv Date 3—( By Date Interim Erosion Control (4370) Prior to scheduling a Framing inspection; rt Framing 4120 g ( ) Approved Electrical, Plumbing & Mechanical Rough -in and Approved to insulate By Date Fire/D Stop inspections must be signed-otr and By Date approved. IBC 109.3.4 Insulation (4150) Gypsum Wallboard Nailing (4130) Suspended Ceiling Grid (4265) Approved to install wallboard Approved to install mud & tape Approved to drop tile By Date By Date By Date Final - Fire Department (4060) Final - Planning11 Final Erosion Control (4375) Approved Approved Approved By Date By Date By Date Final - Building (4050) Approved By Date — t— Rough Electrical Approved n Final Electrical Approved Right of Way Approved By Date By Date By Date �Xk T E- INSPECTOR AREA ANDTYPE 0- INSPECTION PAL Noa d -&-r 1 c)•— &4141 i dr' Cl-