Loading...
19-100445A , . .1 ' Building - Single Family Contractor City of Fed e..IWay THOMAS RUDNICK Permit #:19 -100445 -00 -SF MATVEY FOUNDATION REPAIR Community Development Dept. 3927 SW 324TH ST INC INC 33325 8th Ave S Federal Way, WA 98003 FEDERAL WAY WA 98023 Inspection Request Line: (253) 835-3050 1912 S 146TH ST Ph: (253) 835-2607 Fax (253) 8352609 SEATAC WA 98168 SEATAC WA 98168 Project Name: RUDNICK Project Address: 3927 SW 324TH ST Parcel Number: 873196 0230 Project Description: RPP - Underpinning and repair of foundation for stabilization at the SW corner. Owner Applicant Contractor Lender THOMAS RUDNICK MATVEY FOUNDATION REPAIR MATVEY FOUNDATION REPAIR OWNER IS LENDER 3927 SW 324TH ST INC INC FEDERAL WAY WA 98023 1912 S 146TH ST 1912 S 146TH ST SEATAC WA 98168 SEATAC WA 98168 Census Category: 434 - Residential alt/add - no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area (sq. ft.) Additional Permit Information Mechanical to be Included? ..................................... No Is this an Online or O.T.C. application?.................. No Plumbing to be Included? ........................................ No Total Valuation: 11,100.00 PERMIT EXPIRES Saturday, 27 July, 2019 Permit Issued on Monday, January 28, 2019 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. / Owner or agent: 44,hl Date:rp �;vi&N{a arr or Federal Way PERMIT #: 1910044500 THIS CARD IS TO REMAIN ON-SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 Address: 3927 SW 324TH ST Project: THOMAS RUDNICK FEDERAL WAY WA 98023-2425 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential orcler as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Wait must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this cad. El SWM Precon Site Mtg (4400) ® Initial Erosion Control (4365) 3 Footings/Setback(4110) Approved Illy To be done PRIOR to breaking ground ift Approved to place concrete By Date By Date By Date El Underfloor Framing (4285) ® Floor Sheathing (4105) © Shear Walls (4245) Approved to sheath floor Illy Approved to install flooring 1By Approved to install siding By Date By Date By Date El Roof Sheathing (4220) ® Fire/Draft Stops (4095) 0 Interim Erosion Control (4370) Approved to install roofing Illy Approved 1By Approved By Date By Date By Date Prior to sesedawg a Fra ubg inspecdim; 0 Framing (4120) El Insulation (4150) Medrical, Ptmbbg & Medal Rangb-b Approved to insulate Approved to install wallboard and F WDhait Stop iaapeeden z ant be dped- offanti approved. IBC 104.3.4 By Date By Date Q Gypsum Wallboard Nailing (4130) 3 Final Erosion Control (4375) Q Final - Building (4050) Approved to install mud tit tape Approved Approved By Date By Date By Date c3 Q 11 Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date SFA dem Grout. L L r . STRUCTURAL I Cron I GEOTECHNWAL I LAID USE PLAaN LW 9020 SW Washington Square Dr, Suite 505, Portland, OR 97223 1813 Rutan Dr., Suite C, Livermore, CA 94551 1912 S 146th Street, Seattle, WA 98168 P: (503) 641-8311 www.sfadg.com 3/7 Page 2 of 5 LOAD TEST LOG Project I lame: - 7J- C Matvey Foundation Repair Site Ad s: -tit Project Foreman: !!� Test D : + ` Permit Number: ,,,�_ d Inspectc r Name: Jurisdiction: ccr Pier Tested: # / Teat Pressure, psi f "F -O o � 5 Design Load, laps:f �� 9 1 / Toted Creep, in: 0 L? 1 min: 0 5 min: 0 15 min: 40 min: = 2 min: 0 6 min: 0 20 min: 50 mit: CL m Me 3 min: 0 10 min: 0 30 min: 60 min: 4 met: 0 Pier Tested: Test Pressure, psi: Design Load, hips: Total Creep, in: 0 1 min: 0 5 min: 0 15 min: 40 min: 2 min: 0 6 min: 0 20 min: 50 min: CL 3 min: 0 10 min: 0 30 min: 60 min: 4 mn: 0 Continuous special inspection is required during installation per 20091130 section 1810.4.12. Load testing shall be performed in accordance with ASTM Method D1143 (Quick Method). 20 percent of piers shall be tested to 150 percent of design load. Load testing creep acceptance criteria mall be no greater than 0.04 inches within a 10 minute period. If movement is observed greater than 0.04 inches within the 10 minute period the bad test shall be held for an additional 50 minutes, the pier is to be deepened and re -tester, or the pier is to be abandoned and replaced with a new pier. If the load test is to be held the peer movements shall be measured at 15, 20, 30, 40, 50, and 60 minutes. The creep versus the logarithm of time shall be plotted. if the creep rate is less than 0.080 inches between 6 and 60 minutes, the load test shall be considered successful. Non -Co nphance Items: inspect Signature: 3/7 Page 2 of 5 1'. SFA Ekmdgn Group. [ic }' s7auaum 1 civi I c I tRno usf RA wru 9029 SW UP glm Square DdM soft soy. Portland. Oreps 97278 1813 Raton 0*0- safe C, ttverMfra, CWK=ub SMI j sfa 1912 S 1KIh Street. SeAk 98188 707 Casae ltoe RcA Uj* 8, Pdmer tape. CO 80133 PC 913.60.63ti stnrsradgtas I FIELD INSTALLATION LOG Pro* I Name: ' AZ i ! �— / 7 Cafttrac tor — 1 V, Site Project Foreman: v o / ? Pelmit Number —/co j -eO In Arrival: 'Contractor Arrival: G 1 Name: .- L� Juis�ciion: Ctv -F fecle,,41 r<t p.J 11,,,,,,..r�.. Ty,P.i�er,W,M �,�,,.�t, Pad on � Pier OD, in � • •+w�.wq In Length. ft � K � � t✓VF � � � 3 �(/ �L- ir-•G� 3 a 4 I i 1 r r � t PILL '7�L t ; N plianoe Items: i 'i I s�wlkfre: Rt.20r t/ rays i �i v I sfa March 8, 2019 SFA Design Group, LLC STRUCTURAL I CIVIL I GEOTECHNICAL I LAND USE PLANNING 9020 SW Washington Square Drive, Suite 505, Portland, Oregon 97223 1813 Rutan Drive, Suite C, Livermore, California 94551 1912 S 146th Street, Seattle, Washington 98168 p:503-641-8311 www.sfadg.com Special Inspection FINAL SUMMARY REPORT City of Federal Way Planning & Building Department ATTN: Special Inspections RE: Project Name: Rudnick Residence Underpinning Project No.: MFR18-178 Permit No.: 19 -100445 -00 -SF Address: 3927 SW 324th St., Federal Way, WA 98023 Dear Building Inspection Division: This letter serves to certify that in accordance with Chapter 17 of the International Building Code requirements outlined in the General Structural Notes on S 1.1 of the approved permit drawings, SFA Design Group, LLC has performed special inspection as detailed below. The inspector observed the installation of (3) FSI PP288 push piers, verifying pier locations, installation depth, installation pressure, bracket type, pier type, pier diameter and thickness. To confirm pier capacity, load tests were observed following installation and the results were within approved allowances. Please see attached field installation logs and load test data dated, 03/07/2019. All anchors were installed per the intent of the design and any installation deviations were reviewed and approved by this office with no outstanding non-compliance items. Our inspection and testing services do not constitute a warranty or guarantee of any type and were provided and intended to help reduce the risk of construction defects, deficiencies or omissions that may arise during and after construction. It is the contractor's responsibility to perform their work in accordance with the approved construction documents. All inspections and tests were performed and reported according to the requirements of the City Building Regulations and these Administrative Rules and, to the best of my knowledge, the work was in conformance with the applicable workmanship provisions of the State Building Code and Standards. Sincerely, Dustin Huddleston Engineer Technician — SFA Design Group Cc: Tara Todd, Matvey Foundation Repair Reviewed by: Jeff Fitch, PE, P.Eng, SFA Design Group, LLC EXPIRES: 12J2�%20 i �� CITY OF V;A Federal Way RECEIVED JAN 282019 CITY OF FEDERAL wAy COMMUNITY DEVELOPMENT PERMIT APPLICATION PERMIT CENTER + 33325 81' Avenue South + Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + permitcentel(@,citvoffederalwav.com PERMIT NUMBER —) I _ I 0 O -�E _ -iE TARGET DATE SITE ADDRESS 3997 SW 394th St Federal Way WA W9.14 SUITE/UNIT # PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL M $11,100 RS7.2 —8. —2 -3- --1- 9— 6— - —0- —2- -3- n TYPE OF PERMIT X BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Rudnick Residence PROJECT DESCRIPTION Detailed description of work to Underpinningof the foundation and repairingfoundation for stabilization on the SW corner. No alterations or additions to the existing footprint. be included on this permit only NAME PRIMARY PHONE Thomas Rudnick 253-661-5448 PROPERTY OWNER MAILING ADDRESS 3927 SW 324th St E-MAIL trudnick84@gmail.com CITY STATE ZIP Federal Way WA I 98023 NAME PHONE Matvey Foundation Repair 253-327-1650 MAILING ADDRESS E-MAIL 1912 S 146th St permits@gomatvey.com CONTRACTOR CITY STATE ZIP FAX Seatac WA 98168 WA STATE CONTRACTOR'S LICENSE N EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE M Matvefr83Zk5 20-1 Z-1 01757 -00 -151 - NAME Matvey Foundation Repair -Tara Todd PRIMARY PHONE 253-680-9200 MAILING ADDRESS 1912 S 146th St E-MAIL permits@gomatvey.com APPLICANT CITY STATEZD' FAX Seatac WA 98168 NAME PRIMARY PHONE PROJECT CONTACT Same as applicant MAILING ADDRESS E-MAIL (The individual to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) PROJECT FINANCING NAMEself financed by owner OWNER -FINANCED MAILING ADDRESS, CITY, STATE, ZIP PHONE When value is $5,000 or more (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied t the cit as apart of this application. q SIGNATURE: DATE Nbe I 1 PRINT NAME: / OVA O V Bulletin #100 — January 29, 2016 Page 1 of 2 k:\Handouts\Permit Application MECHANICAL PERMIT CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS no n/a $ n/a Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing Lxtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS (commercial) BOILERS FURNACES HOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES PLUMBING PERMIT $ n/a Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing res to remain. BATHTUBS (or Tub/shower combo) LAVS (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kitchen/utility) WATER HEATERS (Electric) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS no n/a n/a $ EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Single Family -no change 7,680 ❑ Yes X No ❑ Yes x No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE vo ' /},. R. . , t�SEM s--------------------------------------------------------------------------------------------------------------- "' Sur c3 zON l �y f i, ONf Square Feet a Stories NEW BunaING /� F�. :n/ ��., Al / /a -- - - -- - - - FIRST FLOOR (or Mobile Home) :; n/a n/a sEcol��%,Lc> ',, � r ` n/a n!a � �f>�`��� �'" n/a f. .,� r� Area in Occupancy Group(s) COVERED ENTRY # of n/a Square Feet DEcx Type n/a / ,. --------------------------------------------------------------------------------------------------------------------- .... ., GARAGE ❑ CARPORT ❑ n/a n/a n/a OTHER (describe) n/a r r; ,f TENANT AREA ONLY Area Totals EBISTDiG PROPOSED n/a TOTAL *:NEW HOMES ONLY** ESTIMATED SELLING PRICE $ n/a # OF BEDROOMS n/a COMMERCIAL — NEW/ADDITION AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet a Stories NEW BunaING /� F�. :n/ ��., Al / /a a ,rf :; n/a n/a ADDITION ADDITION n/a n/a n/a n/a COMMERCIAL — REMODEUTENANT IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet Type Stories roTAi suunzxG n7a n/a n/a n/a f ,f TENANT AREA ONLY PROJECT ARF ONLY% i; Bulletin #100 — January 29, 2016 Page 2 of 2 k:\Handouts\Permit Application