Loading...
18-103808 ie / r � 1 Building - Single Family City of Federal Way Permit #:18-103808-00-SF Commtmity Development Dept 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax(253)835-2609 Project Name: RETREAT MEADOWS LOT 40 Project Address: 35832 2ND AVE SW Parcel Number:724290 0400 Project Description: NEW-Construction of a 3017 square foot 2-story single family residence with a 35 square foot covered entry and a 477 square foot attached garage. Includes plumbing and mechanical. ***4 Bedrooms;$350,000 Estimated Selling Price*** Owner Applicant Contractor Lender LENNAR NORTHWEST INC SPENCER FITCHLENNAR LENNAR NORTHWEST INC OWNER IS LENDER 33455 6TH AVE S SUITE 1-B NORTHWEST INC 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 33455 6TH AVE S UNIT I-B FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 Census Category: 101 -New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 3,017.00 0.00 Additional Permit Information New/Additional Sq.Feet-1st Floor 1574 New/Additional Sq.Feet-2nd Floor 1443 New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 3017 New/Additional Sq.Feet-Basement 0 Basic Plan? No Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 477 Mechanical to be Included? Yes Plumbing Work Valuation? 20000 Mechanical Work Valuation 10000 Number of Stories 2 New/Additional Sq.Feet-Other 35 Plumbing to be Included? Yes New/Additional Sq.Feet-Total 3529 Will Certificate of Occupancy be Issued? Yes Occupancy#1-Use Residence(1 or 2 family) Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2 Residential Total Valuation:387,784.10 Ducting 1 Fans 6 Fireplace Inserts 1 Furnaces 1 Gas Piping 1 Gas Pipe Outlets 4 Hot Water Tanks 1 Bathtubs 3 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 5 Sinks 1 Water Closets 3 Hose Bibbs 2 • • • ,.• e • s „ : . • PERMIT EXPIRES Sunday,21 April,2019 Permit Issued on Tuesday,October 23,2018 I hereby certify that the =bo e information is correct and that the construction on the above described property and the occupancy :nd e use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. • to•a3'/ Owner or agent: ` Date: City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance,this structure was in compliance with the various ordinances of the City regulating building construction or use.This certificate is valid ONLY when endorsed by City staff. Tenant Name: RETREAT MEADOWS LOT 40 Permit# 18-103808-00-SF Address: 35832 2ND AVE SW Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 3,017.00 0.00 Owner Name: LENNAR NORTHWEST INC Owner Address: 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 B •mg Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. #s; THIS CARD IS TO REMAIN ON-SITE Fec�era�Way Construction Inspection Record INSPECTION REQUESTS:(253)835-3050 PERMIT#: 18 103808 00 Address: 35832 2ND AVE SW Project: LENNAR NORTHWEST INC FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. El SWM Precon Site Mtg(4400) El Initial Erosion Control(4365) El Footings/Setback(4110) ,"" CA Approved To.be done PRIOR to breaking ground Approved to place concrete .5e Q By Date By Date By C U Date r, j) ' r L ID Foundation Wall(4115) El Drainage/Downspout(4040) El Plumbing Groundwork(4190) 1,...`.. Approved to place concrete Approved to backfill\ if—r {� Approved to cover f � By t Date`\ l A/� \ By C, C Date I d.' , By C V Date —b - ; G El Slab/Concrete Floor(4255) ® Underfloor Framing(4235) Q Floor Sheathing(4105) Approved to place concrete Approved to shatb floor Approved to install flooring e7 C By Date By Date By Date M Shear Walls(4245) M Roof Sheathing(4220) M Rough Plumbing(4230) Approved to install siding Approved to install roofing Approved By /11\) Date I By .: Date g ,_ By Date 2"7-4 cc n3 Mechanical Rough-in(4165) M Gas Piping(4125) M Fire/Draft Stops(4095) B Approved Approved to release test Approved Z By _ Date / By Any Date 2, By i Date 2' t El Interim Erosion Control(4370) Prior to scheduling a prig Framing(4120) e Electric'',Plumbing Me haakal Rea f-ia Approved sad Fire/Draft slap tsa*eeiiaas asst be signed- Approved to insulate Date off and approved. MC 1Y1.14 BY Date Z 1 an Insulation(4150) V f t3' Gypsum Wallboard Nailing(4130) 77 Final Erosion Control(4375) Approved to install wallboard 50 ; ' Approved to install mud&tape Approved By 'lr0 Date 2,6 By Date,2% Z - 1 ' By Date 31 Final-Mechanical(4065) ' M Final-Plumbing(4075) 2] Final-BuIlding(4050) Approved� Approved Approved : et,j Date ft-it- 0 By 40 Date Y""y- BY4e, Date fe--- �/- uF.r F)4 (k)%k r .. 6 1 - ,k)- 0 Rough Electrical 0 Final Electrical 0 Right of Way Approved Approved Approved By Date By Date By Date 3017 40 SRECEIVEDPERMIT APPLICATION CI*OF �.� . AUG 2 2 2018 Federal Way CITY OF FEDERAL WAY Q PERMIT NUMBER / g _ / 5° O E PME� '' _1 0 V - TARGET DATE a_(.0 SITE ADDRESS SUITE/UNIT I 35832 2nd Ave SW Federal Way WA PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL A • $ 175,000.00 RS7.2 7 2 4 2 9 0 - 0 4 0 0 TYPE OF'PERMIT 19 BUILDING M PLUMBING U MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT Retreat Meadows Build New 2 story SFR 3017 Sq Ft. Lot 40 PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE Lennar Northwest Inc. 253-590-2215 PROPERTY OWNER MAILING ADDRESS E-MAIL 33455 6th Ave S.,Unit 1-B spencer.fitch@lennar.com C" ederal Way `WA XII ' Lennar Northwest Inc. PHONE253-590-2215 CONTRACTOR MAILING 3455 6th Ave S.,Unit 1-B spencer.fitch@lennar.com CITY STATE Way ` AWA ZIP 98003 FAX WA STATE CONTRACTOR'S LICENSE I EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE t CC LENNNANI893QG 11/ 7 /2019 NAMES Spencer Fitch PRIMARY PHONE P 253-590-2215 APPLICANT MAILINGADDRESS33455 6th Ave S.,Unit 1-B it-mon ITS spencer.fitch@lennar.com a Federal Way `�IWA 21x98003 FAX NAME PRIMARY PHONE PROJECT CONTACT Spencer Fitch 253-590-2215 (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence 33455 6th Ave S.,Unit 1-B spencer.fitch@lennar.com concerning this application) clederal Way WA ZIP 98003 FAX PROJECT FINANCING NA ennar Northwest Inc. --0WU 4 MNC ie.--- When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW19.27.095) 33455 6th Ave S.,Unit 1-B 253-590-2215 I certify under penalty of perjury that I am the property owner or authorised agent of the property owner.I certify that to the best of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating . construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE: Speneeu`;� DATE 8/20/2018 • PRINT NAME: Spencer Fitch Bulletin#100-February 22,2016 Page 1 of 2 1c\Handouts\Pennit Application - ----- CI* i • • VALUE OF MECHANICAL WORK A MECHANICAL PERMIT $ 10,000.00 Indicate how many of each type offacture to be installed or relocated as part of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS FANS 4 GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER T FIREPLACE INSERTS HOODS ...R;rI BOILERS 1 FURNACES 1 HOT WATER TANKS IO,4Tankless COMPRESSORS GAS LOG SETS REFRIGERATION SYST 1 DUCTING —4 — GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT • $ 20,000.00 Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. 3 BATHTUBS for Tub/Shower Combo) 5 LAVS(Hand anlu) 3 TOILETS WATER PIPING — 1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS 1 SINKS pciw,en/ubii5y( WATER HEATERS(Elecui.) —2-- HOSE B1BBS SUMPS 1 WASHING MACHINES 16 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE O!EXISTING IMPROVEMENTS N/A Lakehaven Utilty District N/A RIQSTING/PREVIOUS USE LOT SIZE(In Square Peet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED TIRE SUPPRESSION SYSTEM? Vacant 8,499 ❑Yes No fire sprinkler?o s 411 No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE FIRST FLOOR(or Mobile Home) 0 1574 1574 ':::§-i-60. NZ).-FLOOR : -, • • • 0 ...--.';'--,:-..'-',.,4443.,..,. :1443;'-,, . COVERED ENTRY 0 35 35 GARAGE Ir CARPORT ❑ 0 477 477 ,,Q'FHER,-•(c1 sia�e) • _ Area Totals `ANO PROPOSE') TOTAL 3529 3529 ESTIMATED SELLING PRICE$ 350,000.00 I'#OF BEDROOMS 4 COMMERCIAL—NEW/ADDITION Area in Construction #of AREA DESCRIPTION q Occupancy Group(s) ape Stories Additional Information Square Feet ADDITION - COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Group(s) Construction #of Additional Information Square FeetFP)! Stories r•.q:OTAL BUIL INO •�:` •to],, _- - ,' • • TENANT AREA ONLY �. PRo,Iact AREA ONLY :, Bulletin#100—February 22,2016 Page 2 of 2 k:\Handouts\Permit Application REC i.:"..J ya AUG 2 2 2!?13 F I I_ E , , „ TY r F=DEF.'.L':yi,Y CO4 kehav n WATER& SEWER DISTRICT lit Lakehaven Water&Sewer District - Development Engineering Section 31623 - 1st Ave S . PO Box 4249 t Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ® Building Permit-SFR(56) 0 Building Permit-MFR 0 Building Permit-Other 0 Subdivision 0 Short Subdivision 0 Binding Site Plan ❑ Rezone 0 Boundary Line Adjustment ❑ Other(specify/describe) Tax Parcel Number(s): TBD (oris. 3021049020, 3021049021, 3021049058, 3021049082) Site Address: Multiple Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: 3.500-4,500 sf Lakehaven GIS Grid: H-13 Applicant's Name: Lennar NW. Inc. WATER SYSTEM INFORMATION 1. ® Water service can be provided by service connections to a new /If diameter water main that is approximately 10+/- to 185+/-feet from the plat lots. 2. 0 Water service for the site will require an improvement to Lakehaven's water distribution system of: ❑ a. feet of "diameter water main to reach the site; and/or ❑ b. The construction of a water distribution system on the site; and/or ❑ c. A major portion of Lakehaven's comprehensive water system plan would need to be implemented and/or constructed; and/or ❑ d. Other(describe): 3. ® a. The existing water system is in conformance with Lakehaven's Comprehensive Water System Plan. ❑ b. The existing water system is not in conformance with Lakehaven's Comprehensive Water System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The subject property is within the corporate limits of Lakehaven Water&Sewer District,or has been granted Boundary Review Board approval for extension of water service outside of Lakehaven's water service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Water service Is subject to: ® a. Payment of connection charges(to be determined by Lakehaven); ® b. Proof or reservation of easement(s) as required by Lakehaven; ® c. Other: Water Service Connection applications(1/lot) required. Comments/special conditions: Associated Developer Extension Agreement project(#6314010) must be accepted by Lakehaven.prior to activating service connections. Service pressure greater than 80 psi Indicated for some plat lots, some Pressure Reducing Valves indicated, contact local building official for requirements&/or additional information. The nearest fire hydrants are approximately 5+/-to 375+/-feet from the plat lots(as shown on map on the back of this page). System hydraulic model results (FF #57, copy attached), at no less than 20 psi, Indicate that Lakehaven's standard maximum allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 2,700 GPM (approximate). This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water distribution system improvements, contact Lakehaven for additional information. 450 Pressure Zone Est. Meter Elevation(s)-GIS: High 276+/-, Low 248+/- Est. Pressure Range at Meter(s) (psi): 73-87 I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR - XLDate: —3 /1ic Signature: .•� t �.. j .15: `A L,. fff Retreat Meadows wtr.docx (Form Update 1/3/17) Page 1 of 2 SW 356 - u F s2' le 1 Hyd r Hydr. 2 '� E ' 3 _ c41 — 4 et 302104902 7 7Kt �S 302I049035 F K 9 d 8 1(7--N./ Hyd r. riPrAIR 56 3021049125 11 4 4. 12 3021049118 54 53 5 3021049164 13 kI �' , 8"IiI 14 �o SW .8TH ST 15 q 43 46 47 3021049155 3021049121. 16 EO \ t 17 42 51 B 41 358TH PL ■ 41 50 40 49 3021049004 11 in 39:148 19 rin 135 134 3021049126 20 cl i .4 3021049157 r. 21 -+, "DI , ;4 r, 22 C 26112 30 3021049092 23 t, 3021049013 8"Dr v,� • , , - 3OTE: Lake haven Water and Sewer Water Certificate of Aval ability s District nether warrants nor guarantees mat of Retreatment Meadows i the accuracy of any facility information o MO 440 provided.Facility locations and conditions are subject tofirk,veriicatian. Fees 3/52018 BIA I Retreat Meadows wtr.docx (Form Update 1/3/17) Page 2 of 2 RECEIVED 14 AUG 222018 F I L E CITY OF"r DE EPN-- ilUir WATER&SEWER DISTRICT Lakehaven Water &Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580 • Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ® Building Permit-SFR(56) 0 Building Permit-MFR 0 Building Permit-Other ❑ Subdivision 0 Short Subdivision 0 Binding Site Plan ❑ Rezone 0 Boundary Line Adjustment ❑ Other(specify/describe) Tax Parcel Number(s): TBD(oris. 3021049020, 3021049021, 3021049058,30210490821 Site Address: Multiple Ex. Bldg. Area to Remain: N/A sf New Bldg.Area Proposed: 3,500-4.500 sf Lakehaven GIS Grid: H-13 Applicant's Name: Lennar NW, Inc. SEWER SYSTEM INFORMATION 1. ® Sewer service can be provided by service connections to new 2", 3" or 6" diameter sewer mains that are approximately 5+/-to 150+/-feet from the plat lots and the sewer system has the capacity to serve the proposed land use. 2. 0 Sewer service for the site will require an improvement to Lakehaven's sanitary sewer system of: ❑ a. feet of "diameter sewer main or trunk to reach the site; and/or ❑ b. The construction of a sanitary sewer collection system on the site; and/or ❑ c. A major portion of Lakehaven's comprehensive wastewater system plan would need to be implemented and/or constructed; and/or ❑ d. Other(describe): 3. ® a. The existing sewer system is in conformance with Lakehaven's Comprehensive Wastewater System Plan. ❑ b. The existing sewer system is not in conformance with Lakehaven's Comprehensive Wastewater System Plan and an Amendment to this Plan will be required.This may cause a delay in issuance of land use approvals or permits. 4. ® a. The proposed site land use Is within the corporate limits of Lakehaven Water&Sewer District,or has been granted Boundary Review Board approval for extension of sewer service outside of Lakehaven's sewer service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Sewer service Is subject to: • a. Payment of connection charges(to be determined by Lakehaven); ® b. Proof or reservation of easement(s)as required by Lakehaven; • c. Other: Sewer Service Connection Permit(1/lot) reauired. Private Grinder Pump Agreement(1/lot) rewired.. Comments/special conditions: Associated Developer Extension Agreement oroiect(#6314010) must be accepted by Lakehaven, prior to activating service connections. I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR t � r ° "' Date: /57/ Signature: �^�-� f ; Retreat Meadows swr.docx (Form Update 1/3/17) Page 1 of 2 4 SW 3567 N ST • 1 1 :y < < VI • E • N, ■ :q 4 ` x � ro 302104902 7 5 3021049036 F � t A 8 tr • . 10 4 56 . 3021049125 11117 55 • 3021049118 5 3021049164 ■ 153 ■ t •., ■■•■■ I.. SW358THST Le 46 3021049156 3021049121 16 `. 17 51 B • ■ .50 . 3 358H P : 91 ■■■ 40 49 ■ .r 3021049004 . a • =al 48 39 . In . M = In • _ __min � . 19 . q 5 34 3021049126 20 • N EII3 � _ 3021049157 MI: . SW 359TH •L 4" t IN pull I ■■p■■. C III 26 28 29 3021049092 • j 6" 3021049013 ....•..l■■p■l■■i ' M 4144TE: Lakehaven Water and Sewer Sewer C ertificate of Availability District neither warrants nor guarantees Plat of Retreatment WWeadows the accuracy of any facilky information © 100 400 provided.Facility locations and conditions are subject tofield verification. IMIIIIIIIIIIIIMMIIIII Fee 3/5/2018 8IA Retreat Meadows swr.docx (Form Update 1/3/17) Page 2 of 2 • , • LAKE HAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form Requested By: Date: Bert Ross 03/3/98 Hydrant Location: Off site of Illahee Jr HS 1/4 Section: H-14 Intersection: Approx. S 360th and 1 Ave S Add. Description: KL'SULIS BT: DAM: MUUbL cue NU.: John Bowman 03/05/98 95LUDSFF.INP FF#57 Condition Pressure (psi) Flow (gpm) Static 100 0 Fire Flow 20 4800 NOTE: This fire flow rate will cause velocities in excess of 10 f/s within the water distribution system. A fire flow rate less than 2700 gpm will maintain flow velocities below 10 f/s. There is no guarantee that the Hydraulic Model results will represent actual system performance. Model results depict the theoretical performance of the system under high demand conditions. Field measurements should always be obtained for design purposes. zv.z r 55' INSTALL SILT FENCE AS SHOWN PROPOSED SEWER SIDEWALK GRINDER LOT 4i SIGN F PUMP PLANTER N88'33'3WW 160.37' 2'z10' PERFORATED PIPE CONNECTION �' ` , c6----,__. — TRENCH PER 2016 KC SWDM FIGURE ( 10' -- — C.2.11.A APPROX. LOCATION, CONTRACTOR TO FIELD LOCATE I UE �BUILDING ROW I FOOTPRINT SS STUB VALVE v;� PORCH LOT 404- ca� Y b PROPOSED SINGLE ^-SS- M .4 ;, 3. FAMILY RESIDENCE ✓ a I" ¢ �� n o v p co ]> EAVE � Q ` N o MSD Z z , --.. —�—. , A __. — — j — N88'33'35'W 1 %35 WATER SERVICE SD STUB 11^ 39 1. FINISHED GRADE TO SLOPE AWAY NOT LESS THAN 1:12 FOR A MINIMUM OF 6—FT OR TO PROPERTY LINE ADJACENT TO FOUNDATION AND SHALL START BELOW THE BOTTOMS OF ALL FOUNDATION VENTS, PROVIDE ADDITIONAL SOIL AS REQUIRED TO CREATE DRAINAGE AWAY FROM STRUCTURES ALONG PROPERTY LINE BETWEEN STRUCTURES. 2. ANY PORTIONS OF STRUCTURES WITH LESS THAN 10—FEET OF SEPARATION SHALL BE FIRE RATED. 3. INSTALL 8" OF TOPSOIL WITH 4" OF COMPOST WORKED INTO THE TOPSOIL. THIS WOULD NEED TO BE SPREAD OVER THE ENTIRE SITE, WHERE LAWN AND OTHER LANDSCAPING WOULD BE INSTALLED BY THE BUILDER OR FUTURE HOMEOWNER. 26.27' 1 49' Oemgned etas scale: Q„G 14A(j 18215 72ND AVENUE SOUTH Drawn DeRMS Horizontal ov '♦'I]'�� �Z KENT, WA 98032 1•=20• (425)251-6222 rAaak� eras (425)251-8782 FAX Vertical o r, 1 > FlIe:P:\18000s\18221\lots\18221—Retreat Meadows—Lotdwg Date/Tme:7/12/2018 10:13 AM DBRIGGS For: LENNAR NORTHWEST INC. 33455 6TH AVENUE SOUTH, UNIT 1-B FEDERAL WAY, WA 98003 (253) 590-2205 85.1' 85,08' GARAGE: 20' ME 5' REW: 10' LOT ADDRESS: 35832 2ND AVE SW FEDERAL WAY, WA LOT SIZE = 8,499 SF TOTAL IMPERVIOUS: 2,898 SF (34.1 ROOF: 2,324 SF DRIVEWAY: 446 SF m WALKWAY: 26 SF PATIO: 102 SF TCE =INSTALL TEMP. CONST. ENTRAI TSS =INSTALL TEMP. SOIL STOCKPILE HOUSE PLAN No. 30 Title: Job Nurr RETREAT MEADOWS 182 RESIDENTIAL SITE P4 k: �V ::; SUBDIVISION LOT-40 sbee PARCEL NO. TBD AUG2 2 2018 1 !I