Loading...
02-100265 4 ay om tf unity .e aI Development en Building - Single Family Permit #:02 - 100265.00-.SF Community Develo ment Services , 33530 1st Way S Federal Way,WA 98003-6210 Ph.253 661 4000 Fax 253.661 4129 Inspection request line: 253.835.3050 Project Name: SOUTH CAMPUS BIBLE SCHOOL,LOT#8 Project Address: 1847 SW 352ND ST Parcel Number: 787960 0080 Project Description: NSF with attached garage. Includes plumbing and mechanical. No deck. ***4 bedrooms,Selling price=$224950 *** Owner Applicant Contractor Lender DREAMCRAFT HOMES DREAMCRAFT HOMES DREAMCRAFT HOMES CITY BANK *MICHELI 215 E MEEKER 215 E MEEKER MJFHOI*092DA 10/1/03 PO BOX 97007 KENT WA 98032 KENT WA 98032 215 E MEEKER LYNNWOOD WA 98046 KENT WA 98032 Includes: Census category: 101 -New si #1 #2 #3 #4 Occupancy Group: R-3 R-3 Construction Type: Type V-N Type V-N Occupancy Load: Floor Area(Sq.Ft.): 1st Floor Proposed Sq.Feet 984 2nd Floor Proposed Sq.Feet 830 Basic Plan No Census Category 101-New single family housf Construction Type#2 Type V-N Garage Proposed Sq.Feet 660 Mechanical Yes Occupancy Group#1 R-3 Occupancy Group#2 • Total Building Sq.Feet R-3 Plumbing Yes 2474 Total Proposed Sq.Feet 2474 Zoning Designation RS 7.2 Plumbing Fixtures ' Description Quantity ., - . Qescription;:'-,,,-:',;:-,;:;;_l Quantity - Description: ;, syr""" Quantity Dishwashers 1 Gas Pipe Outlets 3 Laundry Washer Outlets 1 Bathtubs 2 Lavatories 4 Water Heaters 1 Showers 2 Sinks 1 Water Closets 3 Mechanical Fixtures Description Quantity _ : Description Quantity Description - Quantity) Furnaces 1 Gas Logs 1 Ranges 1 Hoods 1 CONDITIONS: See conditions doc. PERMIT EXPIRES August 26,2002,IF NO WORK IS STARTED. Permit issued on February 27,2002 I hereby certify that the above information is correct and that the construction on the above described property and • the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washington and the City of Federal W y. Owner or agent: Date: . -'1 (, • POSTTIS CARD ON THE FRONT OF BUILDIN i G I VVBUIL 'NG DIVISION , . INSPECTION RECORD la • INSPECTION REQUEST PHONE#: 253-835-3050gli • • PERMIT #: 02-100265-00-SF OWNER'S NAME: DREAMCRAFT HOMES SITE ADDRESS: 1847 SW 352ND 2 ( ) FOOTINGS/SETBACKS 3/7/C Z'' / ( ) FOUNDATION WALL 3/I7/i2 _ ,.,.fir-_ n /5/y�/� -�y%jj�/':'/ij�� �a ,(� ^'n*tYr^-., « j�j) 'Y^ '^f Ki � inn!a 7,' ( ) DRAINAGE: Line f da , �Inwel.i o..y. • tk...5"5 ( ) Connection q7t /f z ( ) UNDERFLOOR FRAMING Vfr /' •z /h ( ) ROUGH PLUMBING: DWV I 1 7/7 2 Water piping 0//P /i I% (a4fOUGH MECHANICAL Aftr,,Z ;75i- 4—t;-o'er— Gas piping Per --'S G-1 s� z Ar,/,..?, SHEATHING 6".'—'1 ---/O 55 Roof /G-elZ--SS Floor 7/iAs�/ ( ) SHEAR WALLS C-/6 zx 5 () ELECTRICAL ROUGH-IN / /JDitch Cover FIRE/DRAFTSTOPS 1/ 7-i ,y Z- • -.LLL + :_o;t. ;`ut_i,c}.�'a, '1`4:0`.';'1,1: s'.,1i 1' s-'O1'I 0 t'i,COW:0 ill14:.EsteE ii-, 10 f. ,a'E_'iftiM �. - ''"7'': ':''r`4"-‘ . ( ) FRAMING/FIRESTOPPING F 7-0 i l'c-5 :j F,'i ,vii': t'.: :1 '',40..T.00-f tivg i-k0)',i*Z,g1 1,G't tS l .'.G0 8*s" -tOrC".4t 1>• r ' ''''..:`.;c:,7:::',,,:. ( ) INSULATION: Floors Walls i lagr07..-.- 1 ;/'c N:F3 A;14)^ 6k(%;:iit1rS tJtrl0t{6Pira 1);V;4(el Ci Tki)4.‘;:0 _G A1►f4't*ITO 0.kte 0)st* . (WALLBOARD NAILING 4-2fl-- L /S ( ) SUSPENDED CEILING ( ) ELECTRICAL FINAL e ^/)-' az , 5 ( ) PLANNING FINAL (/ _ () PUBLIC WORKS FINAL ( ) FIRE FINAL __-'.t i-5 ;:.‘.4:10",r4.r4 a. t:'#,:,**".0 "1 d i i e',1rtlitIDK *,I P,_<.,. HU1,.i.:.4ii I "'.:;a:, , " ` ., `. / ( ) BUILDING FINAL / c! ' e,-a. G V) •;:41:07 `reinh '';, `"i c f%r(4,, 1 i M "-_ •Jev l w 7 O !1 1 tlC MB • INSPECTION LOG 9 DATE INSPECTOR OK CORRTREJ AREA AND TYPE OF INSPECTION Lt1:444 aii-e4,A 0/i S - - - 111 Gilt- 7 VC, ' cnYo G 0 CONSTRU ION PERMIT APPLICATION APPLICATION N BER: OZ- I QQ Si[c -o uv ED., _ A0 PPLICABY - COMMUNITY DEVELOPMENT DEPARTMENT APPLICATION NUMBER: gg APPLICATION NUMBER: - - it6 ga s required information-Please print(in ink)or type** Please note: Electrical, Fire Prevention Systems and Engineering permits may require a separate application. i k'149k _ ■ PROPERTY INFORMATION Q C SITE ADDRESS: 1 V41 5� 5` 2+ S1 ASSESSOR'S TAX/PARCEL#: - I LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY): ■ PROJECT INFORMATION TYPE OF PROJECT(This application): BUILDING ❑ PLUMBING ❑ MECHANICAL 0 DEMOLITION ❑ ELECTRICAL 0 ENGIINE�E�RING❑ FIRE PREVENTION� s SYSTEM PROJECT DESCRIPTION(Provide detailed description): 14e(1)14e(1) CL 6� C,� —` 2--) PROJECT NAME: A CairiWidt,S Gbite `Cz.. c` &il ■ PEOPLE INFORMATION PROPERTY OWNER: NAME: DAYTIME PHONE: DreamCraft Homes (95/) tgi - gig- 215 East Meeker MAILING Kent,WA 98032 IP)" CONTRACTOR: NAME: DAYTIME PHONE: /� DreamCraft Homes ( : ) 8J/ - 671f�'l 7 215 East Meeker `` �� MAILIN( UP): EVENING PHONE: Kent,WA 98032 ( ) - CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: FAX NUMBER: d - - !/'.J3)v. - -5 CONTRACTOR'S REGISTRATION NUMBER: EXPIRATION DATE: (copy of card required) fl)T r 0 / 9r o q a D,} 10 /a / D_.3 APPLICANT: NAME: DAYTIME PHONE: �i,�r.�, krt.). la,r-h n a3) -17e47 MAILING ADDRESS(STREET ADD SS; STATE,ZIP): EVENING PHONE: 15 E 1y��2 Cr1 f GUS} CJb3•�► ( ) - RELATIONSHIPTOPROJECT: 1 FAX NUMBER: �y�f� 0 ARCHITECT 0 TENANT OTHER(DESCRIBE): 77G}�iIl- (3) ✓O"O ��l E-MAIL ADDRESS: CONTACT PERSON FOR THIS PROJECT: ❑ PROPERTY OWNER Pt/APPLICANT 0 CONTRACTOR • ■ DETAILED BUILDING INFORMATION EXISTING USE: �,�p EXISTING BUILDING ASSESSED/APPRAISED VALUATION $ PROPOSED USE: J F?Z. PROPOSED VALUATION FOR IMPROVEMENTS: $ SPRINKLERED BUILDING? 0 YES kr-NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED:0 YES A NO WATER SERVICE PROVIDER: 0 LAKEHAVEN 0 HIGHLINE 0 TACOMA ❑ PRIVATE(WELL) SEWER SERVICE PROVIDER: ❑ LAKEHAVEN 0 HIGHLINE 0 PRIVATE(SEPTIC) • • - **NEW RESIDENTIAL CONSTRUCTION ONLY** NUMBER OF BEDROOMS: ESTIMATED SELLING PRICE: $ a a4� U ■ PROJECT FLOOR AREAS 7 FLOOR EXISTING SQ.FT. PROPOSED SQ.FT. TOTAL - BASEMENT FIRST a 44 q al - SECOND _1g' g THIRD FOURTH OTHER FLOORS(DESCRIBE) DECK GARAGE CI^r- HOW MANY FLOORS? 2- ' O GO ' CO OD TOTAL: ' all l 1 Li Indicate number of each type of fixture MECHANICAL AIR HANDLING UNIT(S) EVAPORATIVE COOLER(S) 1 GAS LOG(S) REFRIG.SYSTEM(S) BBQ(S) FAN(S) I HOOD(S) WOODSTOVE(S) BOILER(S) FIREPLACE INSERT(S) 1 RANGE(S) MISC.( ) COMPRESSOR(S) I FURNACE(S) ,-,� DUCT(S) 3 GAS PIPE OUTLET(S) HEAT SOURCE: ❑ ELECTRIC Ri GAS PLUMBING 2. BATHTUB(S) 4 LAVATORY(S) URINAL(S) I WATER HEATER(S) I DISHWASHER(S) RAIN WATER SYS. VACUUM BREAKER(S) ❑ ELECTRIC Cr5 GAS DRINKING FOUNTAIN(S) 2 SHOWER(S) I WASH MACHINE OUTLET '3 GAS PIPE OUTLET(S) I SINK(S) 3 WATER CLOSET(S) MISC.( ) INTERCEPTOR(S) SUMP(S) ■ DISCLAIMER/SIGNATURE BLOCK I certify under penplty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the City of Federal Way,but only where such claim arises out of the reliance of the city,including its officers and employees,upon the accuracy of the information supplied to the city as a part of this application. �1 NAME/TITLE: vL 'v�'4b ( P � k�. DATE: 12,1V7 lo, ❑ PROPERTY OWNER FAPPLICANT 0 CONTRACTOR - FOR OFFICE USE ONLY: 0 NEW 0 ADDITION 0 ALTERATION 0 REPAIR 0 TENANT IMPROVEMENT CENSUS CODE: LOT SIZE: ZONING DESIGNATION: BUILDING SHELL ONLY? 0 YES 0 NO COMP PLAN DESIGNATION BASIC PLAN? 0 YES 0 NO SECTION TOWNSHIP RANGE NEW ADDRESS REQUIRED? 0 YES 0 NO PLATTED LOT? 0 YES 0 NO CHANGE OF USE? 0 YES 0 NO COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•P.O.BOX 9718•FEDERAL WAY,WA 98063-9718•253-661-4000•FAX:253-661-4129 III • 0 Construction Permit Fee Calculation Sheet *****PLEASE NOTE: ALL FEES MUST BE VERIFIED BY CITY STAFF PRIOR TO ACCEPTANCE OF PAYMENT. CHECKS FOR INCORRECT AMOUNTS WILL NOT BE ACCEPTED!******* Building,mechanical,and fire prevention system fees are based on the following schedule. TABLE A TOTAL VALUATION FEE FACTOR (1)$1.00 to$500.00 (1)$24.25 (2)$501.00 to$2,000.00 (2);24.25 for the first;500.00 plus$327 fa each addbo✓,a/swam or fraction thereof,to and including$2,000.00 (3)$2,001.00 to$25,000.00 (3);71.46 for the first;2,000.00 plus$1500 for each add,fiona/$1.000.00or fraction thereof,to and including $25,000.00 (4)$25,001.00 to$50,000.00 (4)$403.61 for the first;25,000.00 plus$10.82 for each additional$1.000.00 or fraction thereof,to and including $50,000.00. (5)$50,001.00 to$100,000.00 (5);664.35 for the first;50,000.00 plus$7.50 for each addti0na/$I.000.OQor fraction thereof,to and including $100,000.00. (6)$100,001.00 to$500,000.00 (6)$1,025.55 for the first$100,000.00 plus$6.00 for each additional 31.000.00or fraction thereof,to and including $500,000.00 (7)$500,001.00 to$1,000,000.00 (7)$3,337.23 for the fist$500,000.00 plus$5.09 for each additional$1.000.00 or fraction thereof,to and including $1,000,000 00. (8)$1,000,001.00 and up - (8)$5,788.23 for the first$1,000,000.00 plus$3.91 for each additional$1.000.0Qor fraction thereof. Bold number is the base fee for the specified increment Italicized,underlined number is the fee Der additional specified increment PLUS: Add 65 percent of the base building permit fee for plan review fee. Add 25 percent of the base mechanical permit fee for mechanical plan review fee. Add 15 percent of the base building permit fee for Fire District#39 surcharge,commercial only. Add$4.50 for WA State Building Code Council,plus$2.00 per unit for duplex&above. ** Electrical, plumbing,and mechanical fees are calculated separately** ■ BUILDING PROPOSED VALUATION: FEE FACTOR FROM TABLE A: Number: (a)Base Fee: (b)Additional Increment Fee: Estimated Permit Fee: (1) Estimated Plan Review Fee: (2) Estimated FW Fire Department Surcharge: (3) • (COMMERCIAL ONLY) ■ MECHANICAL PROPOSED VALUATION: 3765 .30 2 FEE FACTOR FROM TABLE A: Number: (a)Base Fee: (b)Additional Increment Fee: Estimated Permit Fee: (4) Estimated Plan Review Fee: (5) ■ FIRE PREVENTION SYSTEM • PROPOSED VALUATION: FEE FACTOR FROM TABLE A: Number: (a)Base Fee: (b)Additional Increment Fee: Estimated Permit Fee: (6) Estimated Plan Review Fee: (7) • PLUMBING Base Fee Number of Futures $21.00+{ X$7.00/fixture}= (8)Estimated Permit Fee Estimated Permit Fee X .65= (9)Estimated Plan Review Fee Miscellaneous Fixture Charge:(10) Sub Total (Page one): Line(s)(1)+(2)+(3)+(4)+(5)+(6)+(7)+(8)+(9)+(10) = (11) TABLE B NEW RESIDENTIAL SERVICES MOBILE HOMES MISC EQUIPMENT/TEMP SERVICES _Single Family _Service or feeder only $44.25 _#of Thermostats(First-$33.50;add'n-S 1 (First 1300 ft2-567.00;Each add'n 500(12-$21.50) _Service and feeder $72.25 _it of Low voltage fire or burglar alarms Square Feet: First 2500 tie-538.75;Each add'n 2500 112-510. _Each outbuildingor garage S28 00 MOBILE HOME/RV PARK Square Feet: (Inspected with service) _#of service or feeders *I'cr WAC 296-46-910(5)(b)(i&ii) _Each outbuildingor garage $44.25 (First service/feeder-$44.25;Add'n service/ _#of Signs(First sign-$33.50;add'n sign (Inspected separately) feeder-$28 each) $16.00 each) Progress inspection per' hr $33.50 _Swimming pool.hot tub,spa 67.00 Yard Pole meter loops 44 25 `NEW MULTI-FAMILY COMMERCIAL/INDUSTRIAL COMMERCIAL/INDUSTRIAL (Includes three units or more) Altered Service or Feeders Service Feeder Amps Service or Add'n _0 to 200 $72.25 _Up to 200 amp $72.25 $21.50 Feeder _201-600 169.00 _201-400 amp 89.75 44.25 _0 to 100 $72.25 $44.25 _601-1000 254.50 _401-600 amp 123.25 61.50 -101-200 89.75 56.25 _over 1000. 282.75 _601s.800 amp 158.00 84.25 _201-400- 169.00 67.00 _#of circuits _Over 800 amp 225.25 169.00 _401-600 197.00 78.75 (I-5 circuits-$56.25;Add'n circuits.$5 ea) ALTERED SINGLE/MULTI FAMILY _601-800 254.50 107.25 (When inspected separately from the services.) _801-100O 310.75 129.75 Temporary Service Service or Feeder _Over 1000 339.00 181.00 _0 to 60 $38.75 0 to 200 amp $61.50 _Over 600 volts surcharge 56.25 _61-100 44.25 201-600 amp 89.75 _Mast or meter repair 61.50 _101-200 56.25 _over 600 amp 135.25 _201-400 67.00 _Mast or meter repair 33.50 _401-600 89.75 N of circuits _over 600 97.75 (1-4 circuits-S44.25;Add'n circuits$5 ea) - If service is greater than 200 amp,a plan review is rcq'd.Fee is 35%of permit tee+$56.25.Add'I plan review for other submissions is S67.00/hr. FIXTURE DESCRIPTION(A) FIXTURE FEE FROM TABLE B(B) NUMBER OF UNITS(C) TOTAL(D) TOTAL COLUMN(D): _ Total Column(D) Estimated Permit Fee: (12) • Estimated Permit Fee from Buie 12 Estimated Plan Review Fee: $56.25+ X.35=(13) ■ DEMOLITION Estimated Permit Fee: (14) Bond Amount:(15) • ENGINEERING Estimated Permit Fee:(16) Bond Amount: (17) ■ OTHER FEES Mitigation Fee:(18) (20) (22) 58CC Surcharge:(19) (21) (23) Total(Pages One&Two): Line(s)(11)+(12)+(13)+(14)+(15)+(16)+(17)+(18)+(19)+(20)+(21)+(22)+(23)= (24) Bulletin#100-January 3,2001