18-105335 Building - Single Family
city of Federal Way Permit #:18-105335-00-SF
Community Development Dept. IR
33325 8th Ave S
Federal Way,WA 98003 ` :,. Inspection Request Line: (253)8354050
Ph:(253)835-2607 Fax(253)835-2609 k_ ?_b
Project Name: RETREAT MEADOWS LOT 20
Project Address: 35851 2ND AVE SW Parcel Number:724290 0200
Project Description: NEW-Construction of a 3017 square foot 2-story single family residence with a 35 square foot
covered entry and a 477 square foot attached garage. Includes plumbing and mechanical.***4
Bedrooms;$350,000 Estimated Selling Price***
Owner Applicant Contractor Lender
LENNAR NORTHWEST INC SPENCER FITCHLENNAR LENNAR NORTHWEST INC OWNER IS LENDER
33455 6TH AVE S SUITE 1-B NORTHWEST INC 33455 6TH AVE S SUITE 1-B
FEDERAL WAY WA 98003 33455 6TH AVE S UNIT I-B FEDERAL WAY WA 98003
FEDERAL WAY WA 98003
Census Category: 101 -New Single Family House
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) _ 3,017.00 0.00
Additional Permit Information
New/Additional Sq.Feet-1st Floor 1574 New/Additional Sq.Feet-2nd Floor 1443
New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 3017
New/Additional Sq.Feet-Basement 0 Basic Plan? No
Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0
New/Additional Sq.Feet-Garage 477 Mechanical to be Included9 Yes
Plumbing Work Valuation9 20000 Mechanical Work Valuation9 10000
Number of Stories 2 New/Additional Sq.Feet-Other 35
Plumbing to be Included', Yes New/Additional Sq.Feet-Total 3529
Will Certificate of Occupancy be Issued? Yes Occupancy#1-Use Residence(1 or 2
family)
Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2
Residential
Total Valuation:387,784.10
Ducting 1 Fans 6 Fireplace Inserts 1
Furnaces 1 Gas Piping 1 Gas Pipe Outlets 4
Hot Water Tanks 1
Y{E-•
Bathtubs 3 Dishwashers 1 Laundry Washer Outlets 1
Lavatories 5 Sinks 1 Water Closets 3
Hose Bibbs 2
F - .f
wyr it
PERMIT EXPIRES Saturday, 15 June,2019
Permit Issued on Monday,December 17,2018
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: Date: 1 yl 7/I 9
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance,this structure was in
compliance with the various ordinances of the City regulating building construction or use.This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: RETREAT MEADOWS LOT 20 Permit# 18-105335-00-SF
Address: 35851 2ND AVE SW
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load: -
Floor Area(sq.ft.) 3,017.00 0.00
Owner Name: LENNAR NORTHWEST INC
Owner Address: 33455 6TH AVE S SUITE 1-B
FEDERAL WAY WA 98003
Bui .mg Official Date
The priority focu:in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises.
•
0
-41, . , `
J , .
. - • • ifi&
THIS CARD IS TO REMAIN ON-SITE
Construction Inspection Record
ai INSPECTION REQUESTS:(253)835-3050
PERMIT#: 18 105335 00 Address: 35851 2ND AVE SW
Project: LENNAR NORTHWEST INC FEDERAL WAY WA 98023
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about my of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
SWM Precon Site Mtg(4400) El Initial Erosion Control(4365) 0 Footings/Setback(4110)
Approved To be done PRIOR to breaking ground Approved to place concrete
By Date By Date By Date
CI Foundation Wall(4115) ® Drainage/Downspout(4040) tEl Plumbing Groundwork(4190)
Approved to place concrete Approved to backfill Approved to cover v r!4a— ,
4�
By Date By til Date if l? / BY Date //7 j'
El Slab/Concrete Floor(4255) ® Underfloor Framing(4235) El Floor Sheathing(4105)
Approved to place concrete Approved to sheath boorApproved to install flooring
TIP
By Date By C Date r" 1.— 1 By Date
El Shear Walls(4245) 51 Roof Sheathing(4220) MI Rough Plumbing(4230)
Approved to install si ' Approved to install roofing Approved
By AV'S Date By A Date 2bq By Date
OD Mechanical Rough-in(4165) On Gas Piping(4125) al Fire/Draft Stops(4095)
Approved tP f/ Approved
By Govt Date 3-6-( By4i)5 Date $-6-f By£'t Date 3-6-/-
M Interim Erosion Control(4370) Prior to edie0•11•g a Fraadog imispes ron; cag Framing(4120)
Approved Merlvaiai "� Approved to insulate
amid Fire/Draft Step imiapestiew oast be siva&
By Date Wand approved. IBC 109.3.4 B3'ewes Date 3 4 if
Ti Insulation(4150) 21 Gypsum Wallboard Nailing(4130) ® Final Erosion Control(4375)
Approved to install wallboard Approved to install mud&tape Approved
By ..J" Date 3^ /-/' By f."JA Z'Mhate ..l - - By Date
•31 Final-Mechanical(4065) El • Final-Plumbing(4075) ,27 Final-Building(4050)
Approved Approved Approved
By10S Date 5---A.-/- By` Date ,S`--.Z -/' Byc'lo Date l ali`
0 Rough Electrical 0 Final Electrical [J Right of Way
Approved Approved Approved
By Date By Date By Date
PERMIT #: 18-105335-00-SF
• ADDRESS: 35851 2nd Ave SW
41* 'rlo PROJECT: New Construction
RETREAT MEADOWS LOT 20
DATE: 11/08/2018 FILE
WATER&SEWER DISTRICT
1111111.1111111111
Lakehaven Water &Sewer District - Development Engineering Section
31623 - 1st Ave S PO Box 4249 0 Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 I Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: ® Building Permit-SFR(56) 0 Building Permit-MFR 0 Building Permit-Other
❑Subdivision 0 Short Subdivision 0 Binding Site Plan
0 Rezone 0 Boundary Line Adjustment
❑Other(specify/describe)
Tax Parcel Number(s): TBD(prig. 3021049020.3021049021.3021049058. 3021049082) Site Address: Multiple
Ex. Bldg.Area to Remain: N/A sf New Bldg.Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: H-13
Applicant's Name: Lennar NW. Inc.
WATER SYSTEM INFORMATION
1. lI Water service can be provided by service connections to a new 8" diameter water main that is approximately 10+/- to
185+/-feet from the plat lots.
2. 0 Water service for the site will require an improvement to Lakehaven's water distribution system of:
❑ a. feet of "diameter water main to reach the site; and/or
❑ b. The construction of a water distribution system on the site; and/or
❑ c. A major portion of Lakehaven's comprehensive water system plan would need to be implemented and/or
constructed; and/or
❑ d. Other(describe):
3. 181 a. The existing water system is in conformance with Lakehaven's Comprehensive Water System Plan.
❑ b. The existing water system is not in conformance with Lakehaven's Comprehensive Water System Plan and an
Amendment to this Plan will be required.This may cause a delay in issuance of land use approvals or permits.
4. ® a. The subject property is within the corporate limits of Lakehaven Water&Sewer District,or has been granted
Boundary Review Board approval for extension of water service outside of Lakehaven's water service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
5. Water service is subject to:
® a. Payment of connection charges(to be determined by Lakehaven);
O b. Proof or reservation of easement(s) as required by Lakehaven;
® c. Other: Water Service Connection applications(1/lot) required.
Comments/special conditions: Associated Developer Extension Agreement project(#6314010) must be accepted by Lakehaven. prior
to activating service connections. Service pressure greater than 80 psi indicated for some plat lots, some Pressure Reducing Valves
indicated,contact local building official for requirements&/or additional information.
The nearest fire hydrants are approximately 5+/-to 375+/-feet from the plat lots(as shown on map on the back of this page).
System hydraulic model results (FF #57, copy attached), at no less than 20 psi, indicate that Lakehaven's standard maximum
allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 2.700 GPM (approximate). This flow figure depicts the
theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be
accommodated through water distribution system improvements,contact Lakehaven for additional information.
450 Pressure Zone Est. Meter Elevation(s)-GIS: High 276+/-, Low 248+/- Est. Pressure Range at Meter(s) (psi): 73-87
I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN/ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR
Signature: L _,, Date: EVED
NOV 082018
Retreat Meadows wtr.docx(Form Update 1/3/17) Pae 1 of 2
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
0
I
40k
$w 356 `ti ST 12" 'j '4 ! '-DI 22-Dr 72.13Z et
,2•
111 y Hyd r.
Hyd r. 2 R
awl E
Z
4 ll
..4
302104902 lip
5 N 3021049036
J
ill
-. 9
8 Hydr.
S1'56-1114)
10
3021049125NW
44 55
4i
3021049118
54 53 52
Fr
3021049164
ISW Y,STH ST
15
43 ' " 46 47 3021049156
3021049121 16 :o
17 42 51 w B
+ R
S 358TH PC 7r! 41 50
40 49 3021049004
-
Ma 3 39 48
19
38 IL00153021049126 20 � 3021049157
21 ' -t a
•'
22
C
26 27 28 29 30 3021049092
23
1 3021049013 5-rr '
- in7 .
ItIOfE: Lakehaven Water and Sewer
Water Certificate afAvailebility
District neuter warrants nor guarantees flat of Retreatment Meadows
the accuracy of any facility information a za 440
provided.Facility tocations and conditions
are subject tofekiverdication.
Feet 3/5{2018 BIA
Retreat Meadows wtr.docx(Form Update 1/3/17) Page 2 of 2
♦ !
•
titLakebaven
WATER&SEWER DISTRICT
Lakehaven Water&Sewer District - Development Engineering Section
31623 - 1st Ave S t PO Box 4249 * Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 • Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: ® Building Permit-SFR (56) 0 Building Permit-MFR 0 Building Permit-Other
❑ Subdivision 0 Short Subdivision 0 Binding Site Plan
❑ Rezone 0 Boundary Line Adjustment
❑Other(specify/describe)
Tax Parcel Number(s): TBD(orig.3021049020. 3021049021.3021049058.3021049082) Site Address: Multiple
Ex. Bldg.Area to Remain: N/A sf New Bldg.Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: H-13
Applicant's Name: Lennar NW. Inc.
SEWER SYSTEM INFORMATION
1. ® Sewer service can be provided by service connections to new,2". 3" or 6" diameter sewer mains that are approximately
5+/-to 150+/-feet from the plat lots and the sewer system has the capacity to serve the proposed land use.
2. 0 Sewer service for the site will require an improvement to Lakehaven's sanitary sewer system of:
❑ a. feet of "diameter sewer main or trunk to reach the site; and/or
O b. The construction of a sanitary sewer collection system on the site; and/or
O c. A major portion of Lakehaven's comprehensive wastewater system plan would need to be implemented and/or
constructed; and/or
❑ d. Other(describe):
3. ® a. The existing sewer system is in conformance with Lakehaven's Comprehensive Wastewater System Plan.
O b. The existing sewer system Is not in conformance with Lakehaven's Comprehensive Wastewater System Plan and an
Amendment to this Plan will be required.This may cause a delay in issuance of land use approvals or permits.
4. ® a. The proposed site land use is within the corporate limits of Lakehaven Water&Sewer District,or has been granted
Boundary Review Board approval for extension of sewer service outside of Lakehaven's sewer service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
5. Sewer service Is subject to:
® a. Payment of connection charges(to be determined by Lakehaven);
® b. Proof or reservation of easement(s)as required by Lakehaven;
• c. Other: Sewer Service Connection Permit(1/lot) required. Private Grinder Pump Agreement(1/lot) required.
Comments/special conditions: Associated Developer Extension Agreement project(#6314010) must be accepted by Lakehaven.prior
to activating service connections.
I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR �}
Signature: w-� �!/�✓�-�`�`�`� `' Date: 3/5/I CJ
Retreat Meadows swr.docx(Form Update 1/3/17) Page 1 of 2
!r
SW 356TH ST `
a. a I aka
■ •h,
E «e
..q
4 } x
302104902 lir 5
1.4 3021049036
Y
IP' 47
. 9 a
841111 �4a
a
a
i.
a
10 a 56
3021049125 11Iv 55
12 . 3021049118
54 53 52
3021049164 13 .
_
14
#+, SW 358TH ST
15 I
43 46 1 3021049156
3021049121 16 a
17 42 51 B
i
}
S 358, P1 41 50 : RI
`` 40 49 ■ 3021049004
39 48 "▪ '
CI I
l▪ e
}w
19 : N }
: 4 35 34
3021049126 20 ni 3 3021049157
21 • SW 359TH PL n;}`
211
WIN II III 8 #Eil
6 27 28 29 30 3021049092
6"
3021049013 "a#..� "" „ CE,.i,..,r.errrr`. .
imilib
•
lill
110TE: Lakehaven Water and Sewer SewerCertificate of Availability
District matter warrants nor guarantees
the accuracy of any belay information o Plat of Retreatxivetlt Meadows 400
provided.Facility locations and conditions
IIIIMIIIIIIIIIIIIIIIIMIN
are subject to field venTication.
Feet 3/5/2018 BIA
Retreat Meadows swr.docx(Form Update 1/3/17) Page 2 of 2
, _ f.
. ,
LAKEHAVEN UTILITY DISTRICT
Hydraulic Model Fire Flow Estimate
Request/Reporting Form
Requested By: Date:
Bert Ross 03/3/98
Hydrant Location: Off site of Illahee Jr HS
114section: H-14
Intersection: Approx. S 360th and 1 Ave S
Add. Description:
ddSdLIS bi: — VAIG 4 J MOuEL NM NO.:
John. Bowman 03/05/98 95LUDSFF.INP FF#57
Condition Pressure (psi) Flow (gpm)
Static 100 0
Fire Flow 20 4800
NOTE:
This fire flow rate will cause velocities in excess of 10 f/s
within the water distribution system. A fire flow rate less
than 2700 gpm will maintain flow velocities below 10 f/s.
There is no guarantee that the Hydraulic Model results will
represent actual system performance. Model results depict
the theoretical performance of the system under high demand
conditions. Field measurements should always be obtained for
design purposes.
1l- It\
"A.
RECEIVED 3017 3O
Nov sPERMIT APPLICATION
CITY OF O 2018
Federal Way CITY Onon WAYcoi
ENT
PERMIT NUMBER / V X - / e) 5.3 2 S - S TARGET DATE I - 13-13
SITE ADDRESS SUITE/UNIT t
•
35851 2nd Ave Sw Federal Way,WA
PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL t
$ 175,000.00 RS7.2 7 2 4 2 9 0 _ 0 2 0 0
TYPE OF PERMIT S BUILDING NJ PLUMBING LJ MECHANICAL ❑DEMOLITION ❑ENGINEERING ❑FIRE PREVENTION
NAME OF PROJECT Retreat Meadows `s+ 2,0
Build New 2 story SFR 3018 Sq Ft. Lot 20
PROJECT DESCRIPTION
Detailed description of work to
be included on this permit only
NAME PRIMARY PHONE
Lennar Northwest Inc. 253-590-2215
PROPERTY OWNERMAILING ADDRESS E-MAIL
33455 6th Ave S.,Unit 1-B spencer.j.fitch@lennar.com
O1rx RIF
1 ederal Way STATE' 8003
NAME Lennar Northwest Inc. PHONE
253-590-2215
MAILING ADDRESS E-MAIL
CONTRACTOR 33455 6th Ave S.,Unit 1-B spencer.j.fitch@lennar.com
`Federal Way STATE ZIP FAX
98003
WA STATE CONTRACTOR'S LICENSE{ EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE F
CC LENNNANI893QG 11/ 7 /2019
NAME Spencer Fitch PT2215
APPLICANT I
AILING ADDRESS E"p(5Ihcer.j.fitch@lennar.com
33455 6th Ave S.,Unit 1-B �Y�
STATE
ZIP FAX
�ederal Way
NAME PRIMARY PRONE
PROJECT CONTACT Spencer Fitch 253-590-2215
MAI(The individual to receive and
3455 6th Ave S.,Unit 1-B sNG ADDRESS pencer.j.fitch@lennar.com
respond to all correspondence
concerning this application) clTTederal Way WA ZIP
8003 FAX
PROJECT FINANCING N ennar Northwest Inc. —6 -0WIIBR-i NAwi3Bil`---
When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PRONE
(RCW 1977.095) 33455 6th Ave S.,Unit 1-B 253-590-2215
I certify under penalty of perjury that I am the property owner or authorised agent of the property owner.I certify that to the best
of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in
the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as a part of this application.
SIGNATURE: Spencex g DATE 11/8/2018
PRINT NAME: Spencer Fitch
Bulletin#100-February 22,2016 Page 1 of 2 k:\Handouts\Pennit Application
•
VALUE OF MECHANICAL WORK
MECHANICAL PERMIT $ 10,000.00
Indicate how many of each type offacture to be installed or relocated as pad of this project.Do not include existing fixtures to remain.
AIR HANDLING UNITSFANS 4 '`,, GAS PIPE OUTLETS - OTHER(Describe)
AIR CONDITIONER T( FIREPLACE INSERTS HOODS(Co...eI
BOILERS 1 FURNACES 1 HOT WATER 2434K8(G..Tankless
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
1 DUCTING 4 GAS PIPING WOODSTOVES
VALUE OF PLUMBING WORK
PLUMBING PERMIT
• $ 20,000.00
Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain.
3 BATHTUBSIorThb/Showercoabo) 5 LAVS((i.mSinks) "; TOILETS WATER PIPING
—
1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe)
DRAINS SHOWERS VACUUM BREAKERS
DRINKING FOUNTAINS 1 SINKS(IUuhenfutssa j TV, 4 WATER HEATERS(Uectisi
—2—
HOSE BIBBS SUMPS 1 WASHING MACHINES 16 TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL ARIAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS
N/A Lakehaven Utilty District N/A
EXISTING/PREVIOUS USE LOT SIZE Ku Square Peet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM?
Vacant 7411 ❑Yes IN No ❑Yes 43 No
fire sprinkler?
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
'BASEM,ENT- : _
FIRST FLOOR(or Mobile Home) 0 1574 1574 3`D
;-S C041:PLOOR - - - ,..--6:•...-::.,:;,-..-: „•1443.•' ':-.:1443,y,,
COVERED ENTRY 0 35 35
GARAGE Lt CARPORT 0 0 477 477
•9THER,(describe) - ••--
_ - '-
EXISTING PROPOSED TOTAL
Area Totals 3529 3529
ESTIMATED SELLING PRICE$ 350,000.00 I •OF BEDROOMS 4 r _
COMMERCIAL—NEW/ADDITION
AREA DESCRIPTION °a hi Occupancy Group(s) Construction i of Additional Information
Square Feet Type Stories
ADDITION .
COMMERCIAL—REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION Area in Occupancy Group(s) Construction #of Additional Information
Square Feet Tyke Stories
i .B L - ,. :• ---
-,'j`01'AL IPI PING - i•' - • _ _ •i•.._ ,;_''
TENANT AREA ONLY
. PROJECT AREA ONLjr - - , -.- -
Bulletin#100—February 22,2016 Page 2 of 2 k:'I•landouts\Permit Application
BUILDING SETBACKS:
GARAGE: 20' SIDE: 5' REM: 10'
40.44'
55'
20.06'
PROPOSED
SEWER
PLAT BOUNDARY
SD STUB
Le.3i ill)
GRINDER
PUMP
POWER TRANSFORMER
EXISTING
N88'33'351V 115.50,
1
OWER VAULT
CONTOURS
_ _ _ _ _ — —
— _
_�
TALLSHOSILT FENCE
PATFOOTPRINT
BUILDING
U
3��ROW
S
INFILTRATION TRENCH.
TSS""PLANTER
STRIP
BSBL (TYP.)
PORCH
.,
SIDEWALtCLOT
2® ..
I
10'
b
PROPOSED SINGLE -
f
¢�
UE
SS STUB VALVE
i
o
FAMILY RESIDENCE
I
{
, W
,
,
C
•E,
I
EAVEQC
{ o
¢
=:
z
a °�W"
YARD DRAIN
1'
INSTALL SILT FENCE
I`'
"t
I`
N
AS SHOWNc
1. FINISHED GRADE TO SLOPE AWAY NOT
LESS THAN 1:12 FOR A MINIMUM OF
6—FT OR TO PROPERTY LINE ADJACENT
TO FOUNDATION AND SHALL START
BELOW THE BOTTOMS OF ALL
FOUNDATION VENTS. PROVIDE
ADDITIONAL SOIL AS REQUIRED TO
CREATE DRAINAGE AWAY FROM
STRUCTURES ALONG PROPERTY LINE
BETWEEN STRUCTURES.
2. ANY PORTIONS OF STRUCTURES WITH
LESS THAN 10—FEET OF SEPARATION
SHALL BE FIRE RATED.
3. INSTALL 8" OF TOPSOIL WITH 4" OF
COMPOST WORKED INTO THE TOPSOIL.
THIS WOULD NEED TO BE SPREAD
OVER THE ENTIRE SITE, WHERE LAWN
AND OTHER LANDSCAPING WOULD BE
INSTALLED BY THE BUILDER OR FUTURE
HOMEOWNER.
° Scale: Designed ems sus V 18215 72ND AVENUE SOUTH
am,, DBRM Horizontal KENT, WA 98032
=20' (425)251-6222
Checked eels (425)251-8782 FAX
Vertical 04,
_`►. 8�
AaProved BMS 0 ® ®I►®' y CIVIL ENGINEERING, LAND PLANNING,
N/A <rAA✓G EN GiN��P SURVEYING, ENVIRONMENTAL SERVICES
Date 8 73 78
FlIe:P:\13000s\18221\lots\18221—Retreat Meadows—Lot.dwg Date/rtme:8/10/2018 4:35 NA DBRIGGS
LOT 21
20' 26.06'
NORTHWESTLENNAR
SOUTH,
FEDERALi1
"i M
Title:
SERVICE
LOT ADDRESS:
35851 2ND AVENUE SW
FEDERAL WAY, WA
LOT SIZE = 7,219 SF
TOTAL IMPERVIOUS: 3,481 SF (48.2%)
ROOF: 2,600 SF
DRIVEWAY: 753 SF
WALKWAY: 26 SF
DECK: 102 SF
U o y
TCE =INSTALL TEMP. CONST. ENTRAP A p m
0TSS =INSTALL TEMP. SOIL STOCKPILE m n N
n m
HOUSE PLAN No. 301 ;u Z
Cn o�
Job Numb m � c O
RETREAT MEADOWS9E32,'o 0 W
RESIDENTIAL SITE PLAN A C a bn
SUBDIVISION LOT-20 sheet 0 <
o = 0` u
PARCEL NO. TBD R EWEL` 0 0
1 of.
CITY OF FEDERAL WAY O
GUMUPlMY DEVELOPAoI00