Loading...
18-103443 Building.---Single Fawiiy City of Federal Way Permit #:18-103443-00-SF Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax(253)335-2609 Project Name: RETREAT MEADOWS LOT 19 Project Address: 35845 2ND AVE SW Parcel Number:724290 0190 Project Description: NEW-Construction of a 3264 square foot 2-story single family residence with a 60 square foot covered entry and a 640 square foot attached garage. Includes plumbing and mechanical. ***4 Bedrooms;$350,000 Estimated Selling Price*** \ Owner Applicant Contractor Lender LENNAR NORTHWEST INC SPENCER FITCHLENNAR LENNAR NORTHWEST INC OWNER IS LENDER 33455 6TH AVE S SUITE I-B ., NORTHWEST INC 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 33455 6TH AVE S UNIT I-B FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 Census Category: 101 -New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 3,264.00 0.00 Additional Permit Information New/Additional Sq.Feet-1st Floor 1645 New/Additional Sq.Feet-2nd Floor 1619 New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 3264 New/Additional Sq.Feet-Basement 0 Basic Plan No Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 640 Mechanical to be Included? Yes Plumbing Work Valuation 20000 Mechanical Work Valuation? 10000 Number of Stories 2 New/Additional Sq.Feet-Other 60 Plumbing to be Included? Yes New/Additional Sq.Feet-Total 3964 Will Certificate of Occupancy be Issued? Yes Occupancy#1-Use Residence(1 or 2 family) Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2 Residential Total Valuation:418,379.80 Ducting I Fans 5 Fireplace Inserts 2 Furnaces 1 Gas Piping 1 Gas Pipe Outlets 5 Hot Water Tanks 1 IIIIIIIIIIIIIIIIIIIMIIMIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 5 Showers 1 Sinks 1 Water Closets 3 Hose Bibbs 2 r , r • ••—• PERMIT EXPIRES Wednesday,10 April,2019 Permit Issued on Friday,October 12,2018 I hereby certify that the ab• e in rmation is correct and that the construction on the above described property and the occupancy an. the us= will be in accordance with the laws, rules and regulations of the State of ashington and the City of Federal Way. 11 Owner or agent Date: 6` I lb0 City of Federal Way 1 Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance,this structure was in compliance with the various ordinances of the City regulating building construction or use.This certificate is valid ONLY when endorsed by City staff. Tenant Name: RETREAT MEADOWS LOT 19 Permit# 18-103443-00-SF Address: 35845 2ND AVE SW Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 3,264.00 0.00 Owner Name: LENNAR NORTHWEST INC Owner Address: 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 dr A.4 vz. •v, 3--2/-/7' B Ing Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. .. . ' AT • THIS CARD IS TO REMAIN ON-SITE - Construction Inspection Record �� INSPECTION REQUESTS:(253)835-3050 • PERMIT#: 18 103443 00 Address: 35845 2ND AVE SW Project: LENNAR NORTHWEST INC FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read leR to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 SWM Precon Site Mtg(4400) El Initial Erosion Control(4365) 3❑ Footings/Setback(4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date By Date By %.;\:- i In Date . ^ , ' q 0 Foundation Wall(4115) El Drainage/Downspout(4040) El Plumbing Groundwork(4190) Approved to place concrete Approved to backfill Approved to cover By '<::: ` Date • - By C f3, Date 1- e" I . By C I3 Date I - , ' El Slab/Concrete Floor(4255) El Underfloor Framing(4235) El Floor Sheathing(4105) Approved to place concrete Approved to sheath floor ( Approved to install flooring By Date By C, ` Date a- b'I t By Date El Shear Walls(4245) 51 Roof Sheathing(4220) an Rough Plumbing(4230) Approved to install sidingsi\ l Approved to install roofing Approved By Date)d� � 1 By /4,J Date 12-41 /e By 44 Date II/5 /9 El Mechanical Rough-in(4165) 23 Gas Piping(4125) al Fire/Draft Stops(4095) Approved Approved to release test Approved By C fr Date --L* (1 By Date By I Date /-1 01/9 a3 Interim Erosion Control(4370) Prior to.ebdallag a Fronded*Patton Til Framing(4120) • ApprovedMetrical,Plumbing&MechanicalApproved to insulate sad FiMDraa Stop iaapecti.as asast be rived- By Date .clad approved. IBC 109.3.4 By Date/---k01-19 al Insulation(4150) nn Gypsum Wallboard Nailing(4130) - ' ' Final Erosion Control(4375) Approved to install wallboard Approved to install mud d.tape Approved By C6 Date /--3/-1 By 7 Date Z if By ' Date NMI X31 Final-Mechanical(4065) Final-Plumbing(4075) El Final-Building(4050) Approved Approved • Approved By Date .-• ...14111By Date By .r, Date-3 -071•"/"° AO -v►Ir6)Z O _ l0)3 I 0 Rough Electrical 0 Final Electrical 0 Right of Way Approved Approved Approved By Date . By Date By Date Hb(tIVhU 3265 AUG 0 3 2018 PERMIT APPLICATION CITY OF • Federal Way COCITY NOITY DEVRAL WAY ELOPMENT PERMIT NUMBER J - ] b 3 _ I I . - - - I �, TARGET DATE SITE ADDRESS SUITE/UNIT# • 35845 2nd Ave SW Federal Way,WA PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL t S 175,000.00 RS7.2 7 2 4 2 9 0 - 0 1 9 0 TYPE OF PERMIT pQ BUILDING (iPLUMBING [2 MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT Retreat Meadows • Build 2 story SFR 3264 Sq Ft. Lot 19 PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE Lennar Northwest Inc. 253-590-2215 PROPERTY OWNER w33455 ADDRESS Ave S.,Unit 1-B Spen er.j.fitch@lennar.con CIFederal Way AWA E 98003 NA"E Lennar Northwest Inc. PH253-590-2215 CONTRACTOR 33455 6th Ave S.,Unit 1-B E-MAIL p"e cer.j.fitch@lennar.com Federal Way STATE ZIP WA 98003 FAX •Wlrfil1V 1V L"11V 107 EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE e 1V 1V�11V12S )1117 11/ 7 /2019 NAME PRIMARY PRONE Spencer Fitch • 253-590-2215 APPLICANT MAILING ADDRESS E-MAIL 33455 6th Ave S.,Unit 1-B Spencer.j.fitch@lennar.com CITY_ ederal Way °TWA z1l98003 FAX NAMEHONE PROJECT CONTACT Spencer Fitch 253)P590-2215 (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence 33455 6th Ave S.,Unit 1-B Spencer.j.fitch@lennar.com concerning this application) Orrtederal Way WA E 98003 FAX PROJECT FINANCING N , Lennar Northwest Inc. ®—A#NHI-FINANGIBD-- When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PONE (RCW 19.77.095) 33455 6th Ave S.,Unit 1-B Federal Way,WA 98003 (253) 590-2215 I certify under penalty of perjury that I am the property owner or authorised agent of the property owner.I certify that to the best of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the Issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of'Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: Sperweit.heft DATE 8/1/2018 PRINT NAME: Spencer Fitch • Bulletin#100—February 22,2016 Page 1 of 2 k:\Handouts\Permit Application VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ 10,000.00 Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS rj FANS 5 GAS PIPE OUTLETS • OTHER(Describe) AIR CONDITIONER -2-- FIREPLACE INSERTS HOODS(Commercial) e BOILERS 1 FURNACES 1 HOT WATERrFA�1148 tc,.)Tanldess COMPRESSORS GAS LOG SETS REFRIGERATION SYST 1 DUCTING T GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT 20,000.00 Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. �— BATHTUBS(or Tub/Shower Combo) 5 MVS(Hand Sink.) 3 TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS 1 SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS 1 SINKS)Kitchen/UnVty) WATER HEATERS(FJectuirt 2 HOSE BIBBS SUMPS 1 WASHING MACHINES 16 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS N/A Lakehaven Utilty District N/A EXISTING/PREVIOUS USE LOT SIZE ha Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Vacant 7,219 0 Yes Iii No o Yes et No • RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE ;$ASEMENT r , -_ _ - FIRST FLOOR(or Mobile Home) 0 1645 1645 \ , ds y t,1 ,-SSCO ilp.FLOOR • " J - ..` :1619. 1.619.`",'. . / � COVERED ENTRY 0 60 C0 GARAGE ECJ CARPORT ❑ 0 rt... Iu 640 'OVHERIdescribe) 'Rear.PPti(i' - .'12G.: - t2.0' Area Totals EXISTING SO 4084 :±; _ • . •- .. ,.- - _ a lyiri s o z^ '' : •; .. ,,...2 .:.,..,,...._'-'..'.-k, ESTIMATED SELLING PRICE$ 350,000.00 1 #OF BEDROOMS 4 • COMMERCIAL—NEW/ADDITION AREA DESCRIPTION Area inConstructionGroup(s) Construction #of Additional Information Square Feet Type Stories NEW BUILDIII(#. '. r;C ADDITION COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Groups) Construction #of Additional Information Square Feet Type Stories -.TOI'AL BUILDING _•.t. TENANT AREA ONLY PROJECT AREA ONLY -i= ''i: -- " -- Bulletin#100—February 22,2016 Page 2 of 2 k:lHandouts\Pennit Application RECEIVED • AUG 0 7 2018 ( 06 Lakebave fTY OF FEDE WATER&SEWER DISTR( yjMb RAL WAY NfTY DEVELOPMENT Lakehaven Water&Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580 • Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ® Building Permit-SFR(56) 0 Building Permit-MFR 0 Building Permit-Other ❑Subdivision 0 Short Subdivision 0 Binding Site Plan ❑ Rezone 0 Boundary Line Adjustment ❑ Other(specify/describe) Tax Parcel Number(s): TBD (orig. 3021049020, 3021049021. 3021049058. 3021049082) Site Address: Multiple Ex. Bldg. Area to Remain: N/A sf New Bldg.Area Proposed: 3,500-4.500 sf Lakehaven GIS Grid: H-13 Applicant's Name: Lennar NW, Inc. WATER SYSTEM INFORMATION 1. ® Water service can be provided by service connections to a new diameter water main that is approximately 10+/- to 185+/-feet from the plat lots. 2. 0 Water service for the site will require an improvement to Lakehaven's water distribution system of: ❑ a. feet of "diameter water main to reach the site; and/or ❑ b. The construction of a water distribution system on the site; and/or ❑ c. A major portion of Lakehaven's comprehensive water system plan would need to be Implemented and/or constructed; and/or ❑ d. Other(describe): 3. ® a. The existing water system is in conformance with Lakehaven's Comprehensive Water System Plan. ❑ b. The existing water system is not in conformance with Lakehaven's Comprehensive Water System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The subject property is within the corporate limits of Lakehaven Water&Sewer District, or has been granted Boundary Review Board approval for extension of water service outside of Lakehaven's water service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Water service is subject to: ® a. Payment of connection charges(to be determined by Lakehaven); ® b. Proof or reservation of easement(s) as required by Lakehaven; ❑ c. Other: Water Service Connection applications(1/lot) reauired. Comments/special conditions: Associated Developer Extension Agreement project(#6314010) must be accepted by Lakehaven, prior to activating service connections. Service pressure greater than 80 Psi indicated for some plat lots, some Pressure Reducing Valves indicated,contact local building official for reaulrements&/or additional information. The nearest fire hydrants are approximately 5+1-to 375+1-feet from the plat lots(as shown on map on the back of this page). System hydraulic model results (FF #57, copy attached), at no less than 20 psi, indicate that Lakehaven's standard maximum allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 2,700 GPM (approximate). This flow figure depicts the theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water distribution system improvements,contact Lakehaven for additional information. 450 Pressure Zone Est. Meter Elevation(s)-GIS: High 276+/-, Low 248+/- Est. Pressure Range at Meter(s) (psi): 73-87 I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN/ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR } -0- Signature: L J � � - Date: PERMIT #: 18-103443-00-SF ADDRESS: 35845 2nd Avenue SW Retreat Meadows wtr.docx(Form Update 1/3/17) t PROJECT: New Single Family RETREAT MEADOWS LOT 19 1 DATE: 8/7/18 4 • SW 356�H ST '� 1:',. IN III 12 nr „©r xz Jr- 12.Pir �--- II 1 Ce Hydr. Hydr. 2 E i -r '� N 302104902 T 3021049036 - 4 _____ 9 J r4, Hydr. 10 3021049125 11 p Alhik Rt 12 3021049118 3021049164 13 es 14 • i i ~ '41, 8"DI it) SW '••THST 15 Il Ill 43 46 3021049156 3021049121 16 { 17 42 51 B Tai • 4 3SSTH PL 41 50j , 40 49 3021049004 18 ; 39 48 19 ~ .11111 1111111t0)4 103021049126 Z0 •.111141111114111113021049157 21 •, , i'' r r 22 23 " 6 II 28 29 1 3021049092 3021049013 8-"DI ' v ,...7 A colE: Lakehaven Water and Sewer Yater Certificate of Availability District nether warrants nor guarantees i the accuracy of any facilky information Plat of Retreatment Meadows provided.Facility locations and conditions cc are subject to feid verkication. I 1•111111111 fee; 3/5/2018 BIA Retreat Meadows wtr.docx (Form Update 1/3/17) Page 2 of 2 r RECEIVED 15 . ri:"i Lakebaven AUG 01 2018 lin : eWATER &SEWER UISTRiti7T1Y OF FEDERAL WAY ..... . sit‘s. , COMMUNITY DEVELOPMENTre svimimaimmialam Lakehaven Water&Sewer District - Development Engineering Section 31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249 Telephone: 253-945-1581 or 253-945-1580 • Email: DE@Lakehaven.org This certificate is intended to provide the applicant, land use agencies &/or public health departments with information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations in Lakehaven's or Other Purveyor's system facilities. Proposed Land Use: ® Building Permit-SFR(56) 0 Building Permit-MFR 0 Building Permit-Other ❑ Subdivision 0 Short Subdivision 0 Binding Site Plan 0 Rezone 0 Boundary Line Adjustment ❑ Other(specify/describe) Tax Parcel Number(s): TBD(prig. 3021049020,3021049021, 3021049058, 3021049082) Site Address: Multiple Ex. Bldg. Area to Remain: N/A sf New Bldg.Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: 11-13 Applicant's Name: Lennar NW. Inc. SEWER SYSTEM INFORMATION 1. ® Sewer service can be provided by service connections to new 2", 3" or 6" diameter sewer mains that are approximately 5+/-to 150+/-feet from the plat lots and the sewer system has the capacity to serve the proposed land use. 2. 0 Sewer service for the site will require an improvement to Lakehaven's sanitary sewer system of: ❑ a. feet of "diameter sewer main or trunk to reach the site; and/or ❑ b. The construction of a sanitary sewer collection system on the site; and/or ❑ c. A major portion of Lakehaven's comprehensive wastewater system plan would need to be implemented and/or constructed; and/or ❑ d. Other(describe): 3. ® a. The existing sewer system Is in conformance with Lakehaven's Comprehensive Wastewater System Plan. ❑ b. The existing sewer system is not in conformance with Lakehaven's Comprehensive Wastewater System Plan and an Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits. 4. ® a. The proposed site land use is within the corporate limits of Lakehaven Water&Sewer District,or has been granted Boundary Review Board approval for extension of sewer service outside of Lakehaven's sewer service area. ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. 5. Sewer service is subject to: ® a. Payment of connection charges(to be determined by Lakehaven); ® b. Proof or reservation of easement(s)as required by Lakehaven; EJ c. Other: Sewer Service Connection Permit(1/lot) required. Private Grinder Pump Agreement(1/lot) required. Comments/special conditions: Associated Developer Extension Agreement project(#6314010) must be accepted by Lakehaven, prior to activating service connections. I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of signature. Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR 5//ga / , Signature: /.."----,' Date: P J if PERMIT #: 18-103443-00-SF ' ADDRESS: 35845 2nd Avenue SW PROJECT: New Single Family RETREAT MEADOWS LOT 19 DATE: 8/7/18 Retreat Meadows swr.docx (Form Update 1/3/17) Page 1 of 2 SW 3561f1 S� a a 'b • a " 2 15 •;w E :t 3 :4 4 . x 4 302104902 FP N+ 3021049036 } 9 8 r A ` 10 idight 3021049125 11 ` 12 3021049118 54 53 5 3021049164 13 - - 14 i ��• SW 358TH ST a r 46 1 3021049156 3021049121 16 4. ‘ ti 17 42 51 E3 41 SQ 3 35Walto P Inrl■l ,� 49 4 3021049004 . I. H 39 48 w *w ., 19 - 4 Ili I ' 2 i - 4 35 34 3021049126 2E3 a rxy 1 V.43021049157 MI: SW 359TH •L 1 ■ lull ■ f ell �6 2 t 3021049092 IN II III 6' 3021049013 ■llll•lll• •l/l ,'' - Sill■.■l 4 10 �SUTE: Lakehaven Water and Sewer 1,4Dewe r Certificate tate of Availability District neither warrants nor guararteesPlat of Retreatment Meadows the accuracy of faciky infonformationation 0 mo sin provided.Facility locations and conditions ' are subject tofie id veriication. IMINIIIIIMMIIIIIIIIIIIIMI gee; W5/2018 BIA I. Retreat Meadows swr.docx(Form Update 1/3/17) Page 2 of 2 LAKEHAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form Requested By: Date: Bert Ross 03/3/98 Hydrant Location: Off site of Illahee Jr HS 1/4 Section: H-14 Intersection: Approx. S 360th and 1 Ave S Add. Description: Ka6uL7b ux: DArr„ muuLL Kum Au.: John Bowman 03/05/98 95LUDSFF.INP FF#57 Condition Pressure (psi) Flow (gpm) Static 100 0 Fire Flow 20 4800 NOTE: This fire flow rate will cause velocities in excess of 10 f/s within the water distribution system. A fire flow rate less than 2700 gpm will maintain flow velocities below 10 f/s. There is no guarantee that the Hydraulic Model results will represent actual system performance. Model results depict the theoretical performance of the system under high demand conditions. Field measurements should always be obtained for design purposes. r - IL-1 m PLAT BOUNDARY EXISTING CONTOURS BSBL (TYP.) INFILTRATION TRENCH YARD DRAIN INSTALL SILT FENCE AS SHOWN 40.19' 1. FINISHED GRADE TO SLOPE AWAY NOT LESS THAN 1:12 FOR A MINIMUM OF 6—FT OR TO PROPERTY LINE ADJACENT TO FOUNDATION AND SHALL START BELOW THE BOTTOMS OF ALL FOUNDATION VENTS. PROVIDE ADDITIONAL SOIL AS REQUIRED TO CREATE DRAINAGE AWAY FROM STRUCTURES ALONG PROPERTY LINE BETWEEN STRUCTURES. �O 2. ANY PORTIONS OF STRUCTURES WITH LESS THAN 10—FEET OF SEPARATION SHALL BE ARE RATED. 3. INSTALL 8" OF TOPSOIL WITH 4!' OF COMPOST WORKED INTO THE TOPSOIL. THIS WOULD NEED TO BE SPREAD OVER THE ENTIRE SITE, WHERE LAWN AND OTHER LANDSCAPING WOULD BE INSTALLED BY THE BUILDER OR FUTURE HOMEOWNER. Dwigmd —SMS scale., 18215 72ND AVENUE SOUTH DBR(GGS Horizontal N KENT, WA 98032 (425)251-6222 �-20' checked —BMS V (425)251-8782 FAX Vertical 0 App""� CML ENGINEERING, LAND PLANNING, pad 7 to 18 N/A SURVEYING, ENVIRONMENTAL SERVICES A18221\lots\1822.1—Retreat Meodows—Lot.dwg Date/Umw.7/12/2018 10:13 &M DBRIGGS 1.02' 29' 23.29' Imm NST33-35-W 115 50 WATER SERVICE W ROW BUILDING FOOTPRINT C LOT 19 Z 04 PROPOSED SINGLE FAMILY RESIDENCE PORCH EAVE � PLANTER STRIP N8fr33'35"W 115.50' PROPOSED SS STUB VALVE LOT20 SEWER GRINDER INSTALL SILT FENCE PUMP AS SHOWN 44.58' 22.2' 20' SIDE: 5' REAR 10' LOT ADDRESS 35845 2ND AVENUE SW FEDERAL WAY,:SWA LOT SIZE '--'74219 SF TOTAL IMPERVIOUS: 3,484 SF (48.3%) ROOF: 2,682 SF DRIVEWAY. 617 SF WALKWAY: 83 SF DECK: 102 SF FT—C—E]=INSTALL TEMP. CONST. ENTRAP FTs—s]=INSTALL TEMP. SOIL STOCKPILE HOUSE PLAN No. 32E Job Numl For: LENNAR NORTHWEST INC. Title: RETREAT MEADOWS 1820f 33455 6TH AVENUE SOUTH, UNIT 1-13 RESIDENTIAL SITE ft" -!, EIVED SUBDIVISION LOT-19 Sheet FEDERAL WAY, WA 98003 PARCEL NO. TBD 0 7 2018 (253) 590-2205 IN