Loading...
01-102664 , • city of Federal Way Sign Permit#:01 - 102664 — 00 — SG Community Development Services 33530 1st Way S Federal Way,WA 98003-6210 Ph:253.661.4000 Fax:253.661.4129 Inspection request line: 253.835.3050 Project Name: DAE YOUNG PALACE CHINESE RESTAURANT Project Address: 33324 PACIFIC HWY S Suite408 Parcel Number: 797820 0025 Project Description: SIGN-Install 30 square foot internally illuminated wall sign. EBF-512 SF SAP-30 SF Owner Applicant Contractor Ick Jin&Suk Hui Kim YOUNG'S NEON SIGN CO YOUNG'S NEON SIGN CO 28317 15TH AVE S 30318 13TH AVE NW 30318 13TH AVE NW FEDERAL WAY WA FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 98003-6100 (253)946-1286 P 1/ /Comprehensive Plan Designation Community Business Zoning Designation BC Wall Signs Registration# Sign Type Illuminated Sign Face Sign Face #of Sign Faces Building Width(Ft.) Height(Ft) Elevation A I 01-0145 I Channel Letters I Yes I 10 I 3 I 1 I West CONDITIONS: 1. Pursuant to FWCC,Sec.22-1602(f),no sign may contain or utilize the following:(1)Any exposed incandescent lamp with a wattage in excess of 25 watts.(2)Any exposed incandescent lamp with an internal or external reflector.(3)Any continuous or sequential flashing device or operation.(4)Except for electronic changeable message signs,any incandescent lamp inside an internally lighted sign.(5)External light sources directed toward or shining on vehicular or pedestrian traffic or on a street.(6)Internally lighted signs using 800-milliamp or larger ballasts if the lamps are spaced closer than 12" o.c.(7)Internally lighted signs using 425-milliamp or larger ballasts if the lamps are spaced closer than 6" o.c.(8)All illumination for externally illuminated signs must be aimed away from nearby residential uses &on-coming traffic. 2. Signs should be constructed&installed so that angle irons,guywires,braces&other structural elements are not visible.This does NOT apply to structural elements that are an integral part of the overall design.(FWCC,22-1602(A)) 3. No sign shall project above the roofline of the exposed building face to which it is attached.(FWCC,22-1601(B)(2)) 4. A separate electrical permit is required for any sign requiring electrical work.Electrical work must be approved by one of the City's electrical inspectors.Please call the inspection request line at 253-835-3050 to schedule an on-site inspection,prior to the installation of any such sign(s).Contact a Development Specialist 253-661-4115 for questions regarding electrical permit applications. 5. FINAL SIGN INSPECTION IS REQUIRED in order to receive the sign registration sticker.Please call 253-835-3050 to schedule the inspection. PERMIT EXPIRES January 23,2002,IF NO WORK IS STARTED. Permit issued on July 27,2001 I hereby certify that the above information is correct and that the construction on the above described property the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washingt1 the City of Federal Way. Owner or agent: Date: . FINCEIVED 4110 ter« SIGN PERMIT APPLICATION ' • fey 1 ��F JUL O 5 "I APPLICATION NUMBER: 0 ( - / D Z 6. 6 c/- 0 o VV F���— **The folloWfr slL .information—Please print(in ink)or type** ■ PROPERTY INFORMATION . SITE ADDRESS a -�-'(J� �" Pc.2-- *-,\e-- s' ASSESSOR'S TAX/PARCEL #: `472C/' dve2CJ LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY): • PROJECT INFORMATION TYPE OF PROJECT(Check all that apply): ❑ PERMANENT ❑ TEMPORARY gf NEW ❑ ALTERATION ❑ REFACE ❑ EXEMPT NUMBER OF SIGNS APPLIED FOR WITH THIS APPLICATION: I PROJECT DESCRIPTION (Provide detailed description): I/JGt(( cl "rz,`_ BUSINESS/TENANT NAME: U Ae- yo(A N4 Plat LrA c,� C r-f tN-E-S; es. uRRtor - ■ PEOPLE INFORMATION - SIGN OWNER: NAME DAYTIME PHONE PA& Your)6r PAS-Ac -- c.)- -3) ga-7- 3 868 MAILING ADDRESS(STREET ADDRESS,ES��CITYY,(,SSSTTATTE,,ZIP) 333 DERAL4Y BUSINESS LICENSE NUMBER �w y S\ 4 4-Off CITY OFJ EXPIRATION DATE - - / / CONTRACTOR: NAME c rk���/ C` DAYTIME PHONE) - '^ f-6 MAILING 3ADDRESS(STREET A�'DDDRRp�EESS'S;CITY,STATE,ZIP): EVENING P\HO E: CITY OOF FEDERAL L WAY BUSINESS LICENSE NUMBER S` FAX U)3 ER 6 6( Cr' 1 - - (_.-4c1- . - I 6 CONTRACTORS REGISTRATION NUMBER' EXPIRATION DATE: (Copy required) O &6_0$_011-.1_K'E g- / g- /,003 APPLICANT: NAME DAYTIME PHONE. ( ) MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP). EVENING PHONE. FAX NUMBER CONTACT FOR THIS PROJECT: ❑ PROPERTY OWNER ❑ APPLICANT IK CONTRACTOR E-MAIL ADDRESS: .-- . . - • ■ **TEMPORARY SIGN APPLICATIONS ONLY** - TYPE/PURPOSE OF EVENT: DATE OF INSTALLATION: DATE OF REMOVAL: TEMPORARY SIGN TYPE: ❑ BANNER ❑ INFLATABLE ❑ PORTABLE ❑ SEARCH LIGHTS/BEACON NUMBER OF EACH TYPE: ■ PROJECT DETAILS PROPOSED NUMBER OF WALL SIGNS: ( PROPOSED NUMBER OF FREE STANDING SIGNS: �C(,� TOTAL ESTIMATED PROJECT COST:$ O‘00 NUMBER OF TENANTS/BUSINESS SPACES ON PROPERTY: l �"1/41P � J • ■ TYPE OF SIGN(S)(Check all that apply) PERMANENT FREE STANDING: ❑ MONUMENT ❑ OTHER ❑ PEDESTAL ❑ POLE ❑ TENANT DIRECTORY NUMBER OF EACH TYPE: PERMANENT BUILDING MOUNTED:❑ AWNING ❑ CABINET ❑ CANOPY ❑ CENTER IDENTIFICATION(CID)*CHANNEL LETTERS NUMBER OF EACH TYPE: ❑ MARQUEE ❑ OTHER ❑ PROJECTING ❑ TENANT DIRECTORY NUMBER OF EACH TYPE: • ■ DETAILED SIGN INFORMATION • FREE STANDING SIGN SIGN AREA(SQ.FT.) ILLUMINATED?: REFACE? PART OF CID TOTAL SIGN BASE TYPE WIDTH X HEIGHT X#OF FACES NO/INT/EXT YES/NO SIGN? HEIGHT(FT) HEIGHT(FT) A B C STREET FRONTAGE(Fr): BUILDING MOUNTED ILLUMINATED? SIGN AREA(SQ.FT.) BUILDING EXPOSED BUILDING SIGN TYPE NO/INTERNAL/EXTERNAL WIDTH X HEIGHT X#OF FACES ELEVATION(N,S,E,W) FACE(SQ.FT.) A divvms.e-I e_5 3 49 sa v\.) S- • ■ DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made NAME/TITLE: DATE: 4 / SIGNATURE tt NAME(Print) PRINT FOR OFFICE USE ONLY: ^ ZONING DESIGNATION: 13-V COMP PLAN DESIGNATION: BUILDING MOUNTED SIGN FREE STANDING SIGN AREA PERMITTED: 35 4E1 AR PERMITTED: AREA PROPOSED: 31j AREA PRO ED: 5-14k63 LARGEST BUILDING FACADE: STREET FRONTAL NUMBER OF SIGNS ALLOWED: ' NUMBER OF SIGNS ALL ED: LAND USE APPROVER INITIALS: DATE: STRUCTURAL APPROVER INITIALS: C DATE: REGISTRATION NUMBER: 01 .101 tf S REGISTRATION NUMBER: REGISTRATION NUMBER: - • ;- ... .. REGISTRATION NUMBER: - REGISTRATION NUMBER: = REGISTRATION NUMBER: COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•P.O.BOX 9718•FEDERAL WAY,WA 98003-6221•(253)661-4000• FAX:(253)661-4129 • =3 c 41111 m w m - m v Ei v 33 W m 0 ei00101r1 A _ ' ' I. Di .� 6 m I D3 ..l '1 m I O v13 ' ° m 0 1 40 n (.4 ,, rb --10, ie-o 9 ab y V3 V 0 •• o o RA I . Co V. - c T1 V• --A qk 44414 ,.."IIIIIN m '''' 1141 IIS 0 Z o 4t , ______________ ir J Q n J . 1m 2 7 CO m P°.3 °0 mg gtd ni 0 I 0 Q i4 m [ . . • . C.--. UUP s M il G., w Cil - ! omm1::o 3. /'1j if-f, LA 11 ' IA ,N fiN i4 9 Y\ < (. ^� _ - 1 Y -k-- W- > I` ' Q • T 00 M 0 ri I 0 11,4a 1 I 1111M1 OP 1- PA c err c yAJY Py V) Z m w 11.1 lj 70Q C 1 - 1. C a C m a� .moi+ v-n a) -a 2 ci GJ� ;i* cz i a l 1 -f- w r CO4 C) 0 0 waft �T��= 30 s6 1 -/ yTh (._ 3r,Qrr ----r _. • Y3, � ___e_ DAE YOUNG PALACE CHINESE RESTAURANT II " 7 / f , o _ o r Attachment inspection ELECTRICAL PERMIT required: provide access REQUIRED for inspection prior to covering with face panel 5. TYPICAL INSTALLATION - IItJ 1. BUILDING WALL ( FASCIA ) wtv' ,�,�0 5�'Y�c�-�✓�a • A \ ' -it--. 2. 1" SQ. TUBING FRAMES .,� 3. STANDARD P.K HOUSINGS. G.T.O WIRE & TRANSFORMERSP' ' �5 6 6. 4 i I 2. ED I 4. 3A"'>( ' LEG SHIELDS. BOLTS. WASHERS 6 Pc • r 3. 5. 24 GA. CHANNEL LETTER ( COLOR: RLAc(c ) ' W 7. J ,. . RACEWAY BOX ( COLOR : MATCH TO BUILDING WALL. FASCIA) mi...-- 4. 6. PLEXIGLAS FACES ( REP -Y�Ct,dw . lah(-FE ) JUL Q 5 200 ""` 7. 15mm NEON GLASS TUBE ( u)(1(1-(--. ) 8. 3/4 PLASCO TRIMCAP RETAINER ( f q,c.K. ) CITY OF FEDERAL DEPT WAY 8. / 9. 1/4" DRAIN HOLES BUILDING 9. YOUNG'6 NEON CO I TEL (253) 946-1286 FAX (253) 946-1286