Loading...
93-103022 T -r c a .,)a CITY 335300F FEDERAL WAY Firstt Way South B U I LD I NG PERMIT PERMIT NO: BLD93 ISSUED: 12/03/9363 Federal Way, WA 98003 Building Inspection Requests 661-4140 BY: FC 661-4000 EXPIRES: 06/01/94 ADDRESS:204 SW 292ND ST NO. : 119600-0125 PROJECT DESCRIPTION:CONSTRUCT NEN CONCRETE SHORELINE BULKHEAD OWNER — CONTRACTOR — LENDER WILLIAM CHRISTENSEN ***OWNER IS CONTRACTOR*** **NONE** 204 SW 292ND ST FEDERAL NAY NA 98023 39-2527 NONE BLD?:X NEC?: PIM?: FLR--EXIST--PROP--- DWELLING UNITS: 0 COMP PLAN .9 FEES: TYPE OF NORK:REP USE:RES 1ST.: 0: 0:sf STORIES • 0 REQUIRED PARKING..: 0 SPRINKLERS9 •? PLAN CHECK DEPOSIT.* 8 35.00 CENSUS CATEGORY •565 2ND.: 0: 0:sf HEIGHT - 0.00 ft HAZARD CLASS •9 FINAL PLAN CHECK...* $ 0.10 OCCUPANCY GROUP 3RD.: 0: 0:sf VALUATION REQUIRED SETBACKS FIRE FLOW • 0 gps BUILDING PERMIT....* $ 54.00 :? :? :? :? OTHR: 0: 0:sf EXIST..$: 0 FRONT • 0.00 ft SBCC SURCHARGE * $ 4.50 TYPE OF CONSTRUCTION BSMT: 0: 0:sf PROP...=: 2500 SIDE • 0.00 ft WATER SERVICE..:? :? :? :? :? DECK: 0: 0:sf REAR • 0.O0:ft SEWER SERVICE..:? OCCUPANT LOAD GAR.: 0: 0:sf RECEIVED.:11/23/93 0: 0: 0: 0: TOTL: 0: 0:sf INPERV SURFACE: 0 sf SENSITIVE AREAS?.:? FUEL TYPES.: FANS • 0 BOILERS/COMPRESSORS WATER CLOSETS - 0 . URINALS • 0 TOTAL FEES $ 93.60 f GAS PIPING.: 0 ft HOOD - 0 0-3 HP . 0 BATH TUBS - 0 DRINKING FOUNT.: 0 URN<100K..: 0 DUCT WORK - 0 3-15 HP • 0 SHOWERS • 0 SUMPS • 0 S HMT - 0 WOOD STOVES...: 0 15-30 HP • 0 LAVATORIES - 0 VAC BREAKERS...: 0 CONY BURNER: 0 FURN)100K • 0 30-50 HP - 0 SINKS • 0 DRAINS - 0 BBQ - 0 MISC - 0 5+ HP • 0 DISH WASHERS • 0 LAWN SPRINKLERS: 0 GAS DRYER..: 0 AIR HANDLING UNITS FUEL TANKS ELEC WTR HEATERS...: 0 OTHER FIXTURES.: 0 RANGE 0 <:10,000 CFM: 0 ABOVE GROUND: 0 LAUN NSHR OUTLTS...: 0 GAS LOGS...: 0 ) 10,000 CFM: 0 UNDERGROUND.: 0 i' PERMITS EXPIRE 180 DAYS AFTER ISSUANCE IF NO MORK IS STARTED. RESIDENTIAL AND GRADING PERMITS EXPIRE ONE YEAR AFTER DATE OF ISSUANCE. I CERTIFY THAT THE INFORMATION FURNISED BY ME IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND THE APPLICABLE CITY OF FERERAL NAY REQUIREMENTS WILL BE MET. a"4"1-&0--i-4-4, Zt,1 %Lz-; 4e-0_-- OWNER OR AGENT M_— DATE /2-----3N ctLP COPY t 4. CITY OF FEDERAL WAY BUILDING PERA4IT PERMIT NO: ISSUED: 12 /03/926 X3530 First Way South Federal Way, WA 98003 Building Inspection Requests 661-4140 BY: FC 661-4000 EXPIRES: 06/01/94 ADDRESS:204 SW 292ND ST 7r,1 7 // NO. : 119600-0125 /�/�'� PROJECT DESCRIPTION:CONSTRUCT NEM CONCRUE SHORELINE BUL><.HEAD ''� OWNER _�.�.._, _ -..-_�.,..._.— - —.__.._ . _ CONTRACTOR =-� - - _ lF E WILLIAM CHRISTENSEN ***OSIER IS CONTRACTOR**$ Is 704 SW 292ND ST FEDERAL NAY NA 98023 39-2521 NONE ��... .....�__�_ _ .-_; ,_ w ter., - _ ...w.....-.. __.. _� _ _.aw s� =...--'........ _.. MEC?_ : .�__PLM?: _.FLR __ _.��_ _...--.,... . BLD?:X -EXISTPROW-- Hat.. r COMP PLAN FEES: TYPE OF NORK:REP USE:RES 1ST.: 0: 0:sf' i°SIF +r tEQ11IRFD PARKING..: 0 SPRINKLERS? PLAN CHECK DEPOSIT.* $ 35.00 CENSUS CATEGORY •565 2NND.: : . O:sf! RET '1T...::": 0. ft °` HAIA I CLASS •7 FINAL PLAN CHECK...* $ 0.10 OCCUPANCY GROUP-- :�tD.: 0: 0 s i1 t�AT� ^-*- ^-* E T cumc t .' t a BUILDING PERMIT....* $ 54.00 :? :? :? :? (I : 0: t SSI. IST U 1 f 444 4� �� r L SBCC SURCHARGE * $ 4.50 s Y�4k4+M� B v. TYPE OF CONS1RUCTION m. 1 'iER ' �T: 0.. B. SOP r G a ;.. :? ? :? ? 0 ` REAS, • 4.00.ft SEWER SERVICE..:? OCCUPANT LO40------ ----- Ap. @ $ EC : r1. w . 0: 0: 0: 0: "�L � � PM SURFACE: 0 sf SENSITIVE AREAS?.:? , J �._.. .. BOILERS COMPRES�RS NATER �.T-�w.�..,_ �..�.,�-�w__..___�...__,._<-�___�._..�_ FUEL TYPES.: FANS d CLOSETS • 0 URINALS 0 TOTAL FEES $ 93.60 GAS PIPING.: 0 ft HOOD • 0 0-3 NP - 0 BATH TUBS • 0 DRINKING FOUNT.: 0 P0<IOOK..: 0 DUCT WORK • 0 3-15 HP • 0 SNORERS ...: 0 SUMPS • 0 HIT 0 MOOD STOVES...: 0 15-30 HP....: 0 LAVATORIES - 0 VAC BREAKERS...: 0 ' CONY BURNER: 0 FURN>100K • 0 30-50 HP....: 0 SINKS : 0 DRAINS - 0 HBO • 0 MISC . 0 5+ HP • 0 DISH MASHERS • 0 LAWN SPRINKLERS: 0 'J GAS DRYER..: 0 AIR HANDLING UNITS FUEL TANKS---- ELEC VTR HEATERS...: 0 OTHER FIXTURES.: 0 RANGE - 0 <:10,000 CFM: 0 ABOVE GROUND: 0 I.AUN NSW OUTLTS...: 0 \Y1 _ _ I GAS LOGS...: 0 > 10,000 CFM: 0 UNDERGROUND.: 0 -_.__ _ PERMITS EXPIRE 180 DAYS AFTER ISSUANCE IF NO WORK IS STARTED. RESIDENTIAL AND GRADING PERMITS EXPIRE CO. YEAR AFTER DATE OF ISSUANCE. I CERTIFY THAT THE IMFORMATI�ON/'FURNISEO BY NE IS TRUE AND CORRECT TO THE BEST OF NY KNOWLEDGE AND THE APPLICABLE CITY OF FERFRAL WAY REQUIREMENTS Wilt BE MET. OWNER OR AGENT < L h" �L�- r __._._. _ 1a� �z - 3-x,..3 ;. FIELD COPY p 'O p O O CA p 'n p m p " C N p c p % o z O m o r, p A p O p p N p C p -v p m p us °: ""� °�' "'� °�' ' � °+ z : �� v c °�' � °; � °' cn °; z d m d m m D ni r of S�n h � � r of O m co ,m co 'm co v co m 0 m Z FO w co co m co Eli C co > co _ m = o CA in 3 io D co m m 5 ED, ;.Z o W -n 2 73 b, , W 73 70 p m —. z z � O D m z (f) Z N-1 - • ` -1 O ccy0r , z v Z zw z ,7:z D D Or- 20 r= D '' D m m O O -c") t- 2 ' v� D 7; 71 m C 2 Z D O r 0Z i 0 L— Z r` J1 2• 2 O ,3 N co Co C[1 CO CA CO co 00 CA CO CO CO CO Co CO CO CA W X CO Co fa-) k v w N CJ � � C ci k r j . p U U Ex, w th, R a . 3 R. Tv i Z 11) o P0 m . v �' • City of Federal Way • � FIVE APPLICATION FOR BUILDING PERMIT NOV 231993 PLEASE PR/NT CITY OF FEDERAL WAY APPLICATION #: j9 9 -/ e ,� r T Z'4 TIO ovw Address fie' Lf I ,42 "23. Tenant (if known) Lot # ssessor's Tax # H 7/ eve,-i)/Ar-e). -- // Building_Owne Namg Address // %�. ,�C%/�/�lSj�/1j.S y.,5/ -5-41 vim-fir= a2 (2, City / "C-- 'C'��'V"'1 State 14//5/ Zip P 2-3 '•:3 J (I 2-- Phone /39-- Nature of Work /fef-j7.4"--41-et — 7,� Q '"`_rC/ Y re purr— ( . Name (F,M,L) • Address , Z-J yeti City / %L` 1- State /'e`e1- Zip Contact Person Day Phone Other Phone Fax 3/71L; J-)--7j [ LDING CONTRACTOR Company Name 01x✓ \e- t C L" C i - Address City State Zip Contact Person Phone Fax Contractor's # (card must be presented) Expiration Date Verified ❑ Yes ❑ No f ARCIECT Name Address City State Zip Contact Person Phone Fax LEGAL DESCRIPTION W / Please Complete Reverse Side CD0492(Rev 4/931 STRUCTURE Existing Use ()nosed Use 4 Permit includes: L ilding ❑ Plumbing ,_ echanical ❑ Other Type of Work: ❑ Residential ❑ New ❑ Remodel ❑ Number of Units ❑ Deck ❑ Commercial ❑ Addition ❑ Garage ❑ Shed ❑ Other Enter 1st Floor sq ft 2nd Floor sq ft 3rd Floor sq ft Existing Floor Area sq ft Area Basement sq ft Decks sq ft Garage sq ft Proposed Total Area sq ft 9 :C? : Water Availability ❑ Sewer Availability ❑ On-Site Septic System Availability 0 Project:Valuatt;i3n $. ,� ,� Zoning Lot Size Existing Bldg Vafuatto6 $ . >. is LENDER Name Address City State Zip — MECHANICA .:CONTRACTOR Contractor Name Address City State Zip Contact Phone Fax License # Expiration Date Verified ❑ Yes ❑ No LLUMBING CONTRACTOR: Contractor Name Address City State Zip Contact Phone Fax License # Expiration Date Verified ❑ Yes ❑ No PLUMBING FIXTURE COUNT Water Closets Sinks Urinals Lawn Sprinklers Bathtubs Dish Washers Drinking Fountains Other Showers Electric Water Heaters Sumps Lavatories Washing Machine Drains Tota'Fixture Count ME.CIANICAL UNIT-COUNT' Fuel Type (electric/other) Gas Dryer Air Handling < = 10,000 CFM 15-30 Tons Length of Gas Piping Range Air Handling > = 10,000 CFM 30-50 Tons Furn <100K BTUs Gas Log Unit Heater 50+ Tons Furn >100 BTUs Fans Miscellaneous Fuel Tanks Gas Hwt Hood Boilers Above Ground Cony Burner Duct Work 0-3 Tons Underground BBQ's Wood Stoves 3-15 Tons Total Unit Count DISCLAIMER: I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge and further that I am authorized by the owner of the above premises to perform the work for which permit application is made.I further agree to save harmless the City of Federal Way as to any claim(including costs,expenses, and attorneys'fees incurred in investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the City of Federal Way, but only where such claim arises out of the r an a of the City, including its officers and employees,upon the accuracy of the information supplied to the City as a part of this application. q � 'OwnerlA ant: /)//2//1. i �___/'/�-1 - `r`./,�'CZ // 2- ,�j -- 9 3 9 Date: Page No. 1 CASE HISTORY FOR CASE NO.: BLD93-1263 WILLIAM B CHRISTENSEN 204 SW 292ND ST 11/24/93 Action Description Req/ Schd/ End/ Action Notes Dif® By Update Upd Code Sent Done Done Date By -3T --I. BLDA010 Application received / / / / 11/23/93 11/23/93 FLF BLDA020 Address assigned 11/23/93 / / 11/24/93 11/24/93 KC - see existing OK KC 11/24/93 KC BLDA030 Contractr Registrat'n Verified 11/23/93 / / / / 11/23/93 FLF BLDA050 Location of plans / / / / 11/23/93 11/23/93 FLF - PLANS ROUTED TO PLANNING. 2PLN FLF 11/23/93 FLF BLDA100 Review - Land Use 11/23/93 11/23/93 / / 11/23/93 FLF BLDA200 Review - Plan Check 11/23/93 11/23/93 11/24/93 11/24/93 KC - Permit applicant shall OK KC 11/24/93 KC provide a geoengineer's report on soil/surf conditions found at the job site and make a recommendation for wall repair (the report shall be sealed by an engineer registered in the State of Washington). The applicant shall also provide an engineer stamped detail for the wall construction. The respective engineer shall inspect the work as it progresses and provide the building department a letter or field report of conformance. All of these engineer prepared reports shall be on site for the building inspector to verify during final inspection. • December 3,1993 JMATERIALs Page#1 of10 Report# A93190-001 TESTING ✓ GEOTECHNICAL SERVICES ✓ CONSTRUCTION MATERIALS TESTINCI CoRPoiTIoN ./ CONCRETE&Aspi-IALT MIX DESIGNS I AppROVEd SPECIAL INSPECTION ACTENCy SOILS RECEIVED DEC - 31993 INVESTIGATION CITY OF FEDERAL WAY BUILDING DEPT. REPORT FL-P`M - / 4, 3 BULKHEAD REPLACEMENT . 0 Owner Mr. Bill Christanson 204 S.W. 292nd Street Federal Way, WA 98023 (206) 839-2527 Prepared By Materials Testing Corporation FILE THERE ARE TO BE NO DEVIATIONS TO THE APPROVED DRAWINGS UNLESS OTHERWISE APPROVED BY Th. I EDER4E WRY SW14)1NA bEPT• AubuwN Office 4050AubuRn WAY NofuH,Scuff#5,AubuRA4 WAsIuNgTON 98002 P$ione(206)850-7797 FAx:(206)850-7890 BoisE OfficE: 2 30 SOUTH COLE Road,BoisE IdAlio 83709 Phone.(208)3763748 FAX:(208)3 22-65 15 ` . . December 3,1993 J MATERIALS • Page#2 of 10 Report# A93190-001 1. ENVIRONMENTAL SERVICES TESTING I GEOTECIJNICAI SERVICES ✓ CONSTRUCTION MATERIALS TESTING CORPORATION I CONCRETE&ASPHALT Mix DESIGNS I Appi o Ed SPECIAL INSPECTION AGENCY MR. BILL CHRISTIANSON 204 S.W.292"'Street Federal Way, WA 98023 Attn: Mr. Bill Christianson Re: Soils Report Failed Bulkhead Replacement Gentlemen: In compliance with your instructions, we have conducted a soils exploration and bulkhead replacement report for the property located at the above mentioned address. The results of this investigation, together with our recommendations, are to be found in the following report. We have provided three copies for your review and distribution. The results of the site exploration and analysis indicate that a typical concrete bulkhead appears to be the most suitable type of replacement for the existing bulkhead that has failed. Often, because of design and construction details that occur on a project, questions arise concerning soil conditions. We would be pleased to continue our role as geotechnical engineers during the project implementation. MTC also has great interest in providing materials testing and special inspection services during the construction of this project. If you will advise us of the appropriate time to discuss these engineering services, we will be pleased to meet with you at your convenience. We appreciate this opportunity to be of service to you and we look forward to working with you in the future. If you have any questions please call us at the phone numbers listed at the bottom of the page. Respectfully Submitted, MATERIALS TESTING CORPORATT ( ... .._-:„.„ ,,,,____ _____„„t•sto<v,jAssizip 4 J. Frank Spears,P.E. V.P./General Manager ;. `~ '- groreg t__. -- 70 ' kbURN Offic.: 4050 AubURN WAy NoRTI♦,SUITE#5,AubuuN WAsI1iNGTON 98002 PhoNE:(206)850.7797 FAX:(206)850.7890 Bois Office 230 SouTli Colt Ro.d,Bois Idaho 83709 Phonic(208) 3764748 FAX:(208)322-6515 • MATERIALS • December 3,1993 i IIII/ Page#3of10 Report# A93190-001 I ENVIRONMENTAL SERVICES \ TESTING I GEOTECIINiCA(SERVICES f�iCo ✓ COSTRUCTION MATERIALSTESTiNq RPORATIONI CONCRETE&AspirA(T Mix DESICINS I AppROVEd SPECIAL INSPECTION AgENCy TABLE OF CONTENTS INTRODUCTION 4 Authorization 4 Purpose 4 Scope 4 General 4 DESCRIPTION OF SITE 5 Site Location&Description 5 SUBSURFACE CONDITIONS 5 General Notes 5 Description Of In-Situ Soils 5 FOUNDATION DISCUSSION AND RECOMMENDATIONS 5 General Notes 5 Foundation Design Recommendations 5 CONSTRUCTION CONSIDERATIONS 6 Structural Fill 6 Concrete Bulkhead 6 Lateral Earth Pressures 6 Geoseismic Setting 6 General Comments 6 APPENDIX 7 General Notes 8 Typical Concrete Bulkhead 9 Test Pit Log 10 AUBURN Office 4050AubuwN WAy Norsrh,Subs#5,Auburov WashieeTon 98002 PhoNE:(206)850-7797 Fax:(206)850-7890 BoisE OfficE: 2 30 South ColE Road,BoisE Idaho 83709 Phone(208) 3764748 Fnx:(208) 322-6515 ID December 3,1993 ,Ll MATERIALS • Page#4 of IO Report# A93190-001 TESTING .../ ENVIRONMENTAISERVICES I GEOTECIiNICAI SERVICES r.i ./ CONSTRUCTION MATERIALS TESTINq J CORPORATION ✓ CONCRETE&AsplrAlT Mix DEsigNs ✓ AppROVEd SpEciAl INSpECTION AqENcy SUBSURFACE EXPLORATION & FOUNDATION RECOMMENDATIONS Introduction: This report presents the results of a soils site exploration and analysis for the proposed replacement bulkhead. This investigation was conducted for Mr. Bill Christianson. Authorization: Authorization to perform this exploration and analysis was in the form of a verbal authorization to proceed from Mr. Bill Christianson. Purpose: The purpose of this report and analysis was to determine the various soil profile components, the engineering characteristics of the in-situ soils and to provide criteria for use by the design engineers and architects in preparing or verifying the suitability of the bulkhead design. Scope: The scope of the report and analysis included a review of geological maps of the area and a review of geologic and related literature; a reconnaissance of the immediate site; field and laboratory testing; and an engineering analysis and evaluation of the foundation materials. MTC was not requested to provide an Environmental Site Assessment for this property. Any comments concerning onsite conditions and/or observations, including soil appearances and odors, are provided as general information. Information in this report is not intended to describe, quantify or evaluate any environmental concern or situation. General: The exploration and analysis of the soils conditions reported herein are considered sufficient in detail and scope to form a reasonable basis for the foundation design. Any revision in the plans for the proposed structure from those enumerated in this report should be brought to the attention of the soils engineer so that he may determine if changes in the foundation recommendations are required. If deviations from the noted subsurface conditions are encountered during construction, they should also be brought to the attention of the soils engineer. The soils engineer warrants that the findings, recommendations, specifications, or professional advice contained herein, have been promulgated after being prepared according to generally accepted professional engineering practice in the fields of foundation engineering, soil mechanics and engineering geology. No other warranties are implied or expressed. This report has been prepared for the exclusive use of Mr. Bill Christianson and his retained consultants. Findings and recommendations within this report are for specific application to the proposed bulkhead replacement. All recommendations are according to generally accepted soils and foundation engineering practices. Auburn Office 4050AubuRNWAY NoRrh,SUITE#5,AubuRNWAshiNcrroN 98002 P$ioNe(206)850-7797 FAX:(206)850-7890 BoisE OfficE: 230 Sour{r Colr RoAd,Boist IdAho 83709 Phone(208) 3 764748 FAX:(208) 3 22-65 1 5 i d • . December 3,1993 MATERIALS Page#5 of 10 Report# A93190-001 ✓ ENVIRONMENiAI SERVICES TESTING I GEOTECHNICAI SERVICES I CONSTRUCTION MATERIALS TEAINq CORPORATION ✓ CONCRETE&AspllAlr Mix DEsignis ✓ AppROVEd SpECIAl INSpECTION AGENCY DESCRIPTION OF SITE Site Location & Description: The site of the proposed bulkhead replacement upon which this soils report has been made is the western most edge of the lot located at 204 292"d Street in Federal Way, Washington. The southern half of the existing bulkhead has failed and is causing rapid erosion of the property that was behind the bulkhead. SUBSURFACE CONDITIONS General Notes: The types of soils materials encountered have been visually classified and are described in detail on the test pit log provided in the Appendix. The results of the field penetrometer and vane shear tests, moisture contents and other laboratory tests are presented on the logs. It is recommended that the logs not to be used for estimating quantities due to highly interpretive results. Description Of In-Situ Soils: The surface of the site is covered with 12 to 18 inches of washed beach sand and gravel to cobble sized rocks that extends in depth from 3"to 18". The soil encountered were relatively consistent and typical of the adjacent shoreline area of Puget Sound. A hardpan layer was encountered beneath the existing beach sand and extends to depths beyond the scope of this investigation. Lines of demarcation represent the approximate boundary between the soil types,but the transition may be gradual. In the absence of foreign substances, it is also difficult to distinguish between discolored soils and clean soil fills. It is recommended that the logs not to be used for estimating quantities due to highly interpretive results. FOUNDATION DISCUSSION AND RECOMMENDATIONS General Notes: Various foundation types have been considered for the support of the proposed bulkhead. Two requirements must be fulfilled in the design of the bulkhead. First, the load must be less than the ultimate bearing capacity of the foundation soils to maintain stability; and secondly, the differential settlement must not exceed an amount that will produce adverse behavior of the bulkhead. The allowable settlement is usually exceeded before bearing capacity considerations become important; thus, the allowable bearing pressure is normally controlled by settlement considerations. Bulkhead Design Recommendations: On the basis of the data obtained from the site and the test results from the various laboratory tests performed, MTC recommends that the following guidelines be used for the net allowable soils bearing capacity for bearing the footings on the native hardpan soils. Net Allowable Bottom of Footing Soils Bearing Depth Capacity 24 inches 6,000 lbs./ft2 Total settlement should be limited to 1 inch total with differential settlement of 3/4 inch. Any excessively loose or soft spots or areas that do not meet the compaction requirements that are encountered in the footing subgrade will require over-excavation and backfilling with structural fill or concrete. In order to minimize the effects of any slight differential movement that may occur due to AubuRN Office 4050AubuRN WAyNoarlr,SATE#5,AubuaN WAslriNgroN 98002 PlronE:(206)850-7797 Fax:(206)850-7890 BoisE Office. 2 30 Sourly CotE Road,Bois IdA110 8 3 709 PIroNE:(208)376.4748 FAX:(208) 3 22.6 5 1 5 M • December 3,1993 • A MATERIALS • Page#6of10 Report# A93190-001 ✓ ENVIRONMENTAL SERVICES TESTING ✓ GEOTECIiNICALSERVICES J�� CoRPoiTIoN ✓ CONSTRUCTION MATERIALS TESTINq ✓ CONCRETE&AsphhAlT Mix DEsigNs ✓ AppROVEd SPECIAL INSPECTION AgENCy variations in the characters of the supporting soils and any variations in seasonal moisture contents, it is recommended that all continuous footings be suitably reinforced to make them as rigid as possible. CONSTRUCTION CONSIDERATIONS Structural Fill: Structural fill should consist of a 3 inch minus select, clean, granular soil with no more than 3 %fines (-#200) and placed in layers of not more than 12 inches in thickness. Each layer of structural fill should be compacted to a minimum density of 95 % of the maximum dry density as determined by ASTM designation D-1557. For backfill behind the bulkhead, we recommend that beach sand or other free draining soils be used so that it will act to drain away all water from the land side of the bulkhead. Concrete Bulkhead: The concrete for the bulkhead should be I", of 4,000 psi. and should contain 6.0%± 1.0% air. The reinforcement steel should be grade 60 rebar. All lap slices should be a minimum of 24 inches. The size of the rebar should be #4 bars at 12 inches on center in both the horizontal and vertical directions. Lateral Earth Pressures: Lateral earth pressures are dependent upon the backfill materials and their configuration and moisture content. Based on our recommendations and the "Typical Concrete Bulkhead" drawing as designed and illustrated in the appendix the lateral earth, the bulkhead as design is adequate to withstand the lateral earth pressures from the sandy backfill. Geoseismic Setting: This project site is located within a "Zone 3 Area" as per the 1991 edition of the Uniform Building Code. All building structures on this project should be designed as per the U.B.C. Requirement for such a seismic classification. General Comments: When the plans and specifications are complete, or if significant changes are made in the character or location of the proposed bulkhead, a consultation should be arranged to review them regarding the prevailing soil conditions. Then, it may be necessary to submit supplementary recommendations. It is recommended that the service of a qualified soils engineering firm be engaged to test and evaluate the soils in the bulkhead excavation before placing concrete to determine that the soils meet the recommendations. Monitoring and testing should also be performed to verify that suitable materials are used for structural fills and that they are properly placed and compacted. AubuRNCAGE: 4050AubuRNWAyNoRTll,SUITE#5,AubuRNWAsl1iNGroN 98002 P4rone(206)850-7797 FAX:(206)850-7890 Bois Office. 230 South Cok Road,BOISE kl4io 83709 Mast:(208)376-4748 FAx:(208) 3 2 2-6 5 1 5 j December 3,1993 MATERIALSReport# A93190-001 TESTING ✓ ENIRONMNTA(SICES ✓ GEOTEC�hNIC )SRVICES CORPORATION ✓ CONSTRUCTON MATERIALS TESTING ✓ CONCRETE&ASplIAIT MIX DESIGNS ✓ AppROVEd SpECIA(INSPECTION AGENCY APPENDIX GENERAL NOTES TYPICAL CONCRETE BULKHEAD TEST PIT LOG Aubuae Office 4050AubuaN Way Noar11,SUITE#5,AubuaN Was11iNGToN 98002 PboNE:(206)850-7797 FAX:(206)850-7890 BoisEOfficc 230 South COLE Road,BoisEIda410 83709 P41ONE:(208) 376-4748 FAX:(208) 322-6515 ` December 3,1993 MATERIALS • • Page## A93190-001 f 10 Keport# ✓ ENVIRONMENTAL SERVICES \ TESTING I GEOTECIiNICALSERVICES r4 ✓ CONSTRUCTION MATERIALS TESTINq J CORPORATION ✓ CONCRETE&AsphhAlT Mix DESIGNS ✓ APPROVEd SPECIAL INSPECTION AgENCY GEOTECHNICAL GENERAL NOTES SOIL PROPERTY SYMBOLS N: Standard "N"penetration: Blows per foot of a 140 pound hammer falling 30 inches on a 2 inch O.D. split-spoon. Qu: Unconfined compressive strength,tons/ft2 Qp: Penetrometer value,unconfined compressive strength, lbs/ft2 V: Vane value,ultimate shearing strength, lbs/ft2 M: Water content,% LL: Liquid limit,% PI: Plasticity index, % D: Natural dry density,lbs/ft3 WT: Apparent groundwater level at time noted after completion. DRILLING AND SAMPLING SYMBOLS SS: Split-Spoon- 1 3/8" I.D., 2" O.D.,except where noted. ST: Shelby Tube-3"O.D., except where noted. AU: Auger Sample. DB: Diamond Bit. CB: Carbide Bit. WS: Washed Sample. RELATIVE DENSITY AND CONSISTENCY CLASSIFICATION Terms(Non-Cohesive Soils) Standard Penetration Resistance Very Loose 0-2 Loose 2 -4 Slightly Compact 4-8 Medium Dense 8- 16 Dense 16-26 Very Dense Over 26 Terms(Cohesive Soils) Qu-(tons/ft2) Very Soft 0-0.25 Soft 0.25 -0.50 Firm(Medium) 0.50 - 1.00 Stiff 1.00-2.00 Very Stiff 2.00 -4.00 Hard 4.00+ PARTICLE SIZE Boulders 8 in. + Coarse Sand 5 mm-0.6 mm Silts 0.074 mm-0.005 mm Cobbles 8 in. -3 in. Medium Sand 0.6 mm-0.2 mm Clays 0.005 mm& Smaller Gravel 3 in. -5 mm Fine Sand 0.2 mm-0.074 mm Abu Office 4050AubuRn WAY NoRt4h,SuhE#5,AubuRn WAs11iNGTon 98002 Phone:(206)850-7797 FAX:(206)850-7890 BOISE OflicE: 2 30 Souuh Co*E RoAd,Bois€IdAho 8 3 709 Phone(208) 37 64748 FAX:(208) 322-6 5 1 5 • December 3,1993 A MATERIALS Page#9of10 Report# A93190-001 ENVIRONMENTAL SERVICES • TESTING ../✓ GEOTECIINICAI SERVICES � ✓ CONSTRUCTION MATERIALS TESTINCI J CORPORATION ✓ CONCRETE&AsphALT Mix DEsigNs ✓ AppROVEd SpEciAI INSpECTION AciENcy TYPICAL CONCRETE BULKHEAD -4-18"-)'- ' .c C C C Clean Free . Draining Sand —0 . 4-81 7.0' Height will vary slightly with Grade . 1.0"diameter Drain Pipe _:1:=4--- placed @ 4'on center Beach Sand — 2'6" ► _ ____* Hardpan Soils . e • 1♦0" I_ 4.0' ..-I Horizontal Reinforcement Vertical Reinforcement #4 @ 12" on center #4 @ 12" on center Lap Splice 24" minimum Lap Splice 24" minimum fc =4,000 psi fy =60,000 psi Soils Bearing Capacity (Hardpan): 6,000 psf Aubuan Olficc 4050 Aubuan Way Nooh,SubE#5,Aubure WA1iNgTON 98002 Phone(206)850-7797 FAX:(206)850.7890 Bois Office. 2 30 South ColE RoAd,BOiwE kWio 83 709 Phone(208)3 76-4748 FAX:(208) 3 22.6 5 1 5 December 3,1993 , J MATERIALS Page#'°of 10 Report# A93190-001 TESTING ✓ ENVIRONMENT4SERVICES ✓ GEOTECIiNICAL SERVICES I CONSTRUCTION MATERIALS TESTING �� J CORPORATION ✓ CONCRETE&ASPIiAIT MIX DESIGNS ✓ AppROVEd SPECIAL INSPECTION AGENCY GEOTECHNICAL INVESTIGATION TEST PIT LOG Test Pit#: 1 MTC File#: A93190 Client: Mr. Bill Christianson Date Sampled:: Project: Bulhead Replacement Excavated By: JFS Address: 204 SW 292nd Logged By: JFS City, State: Federal Way,WA Location: Beach Depth of Change Soils Field In Sample Sieve Analysis (Ft) Description Soils Type %M LL PI 3/4" #4 #10 #40 #200 0.5 3"to 18"of beach sand _ __ __ - 1.0 Dark Brown Sandy Silt with Gravel _ GS 25.6%_ _NP_-N_P100 88 49 21 2.3 - 1.5 _ ___ ____ __ __ 2.0 -_Hardman,Gravelly Sand with Silt-- '— --GS- -18.8°/o- _34_ -7 - 100 83 59 25 9.7 - 2.5 to Sandi Gravel with Silt --- ----- -- --- - 3.0 4.0 4.5 - - 5.0 5.5 - ----- - 6.0 - - -- --- - AubusN Office: 4050AubuRN Way Noarii,Suire#5,AubuRN WadliNcrav 98002 Phone:(206)850-7797 Fax:(206)850-7890 Boise Office 230 Sourli Cole Road,Boise Idaho 83709 Phone(208) 3764748 Fax:(208) 322-6515 di. IIP CITY OF 61711�� (206)661-4000 N).\) Fry 33530 1ST WAY SOUTH FEDERAL WAY,WA 98003-6210 December 16, 1993 Mr. William Christensen 204 SW 292nd Street Vslk‘s . Federal Way, WA 98003 RE: New Shoreline Bulkhead, BLD93-1263 ( () 5 �� -rr) Dear Mr. Christensen: The purpose of this letter is to remind you of the agreement regarding your new shoreline bulkhead. As agreed, you must file a shoreline permit no late than February 3, 1cCO December 3, 1993 meeting, in which we issued the building permit provided you file a shoreline permit within 60 days. cow (-t°", eds0 F1C-E `CcfC 5 co( To fulfill the agreement, please provide me photographs of the new cor 7.0 c rk17'P c5 $50, payable to the City of Federal Way, no later than February 3, 1 -F--I LE 7 to begin processing the shoreline permit. c (( Please call me at 661-4110 if you have any questions. Respectfully, Bill Kingman Associate Planner BD931263.LT1