Loading...
01-104031 1111 City of Federal Way 0 Community Development Services Slgn Permit#:01 - 104031 - 00 - SG 33530 1st Way S Federal Way,WA 98003-6210 Ph•253 661.4000 Fax•253 661.4129 Inspection request line: 253.835.3050 Project Name: SPRING VALLEY MONTESSORI Project Address: 36605 PACIFIC HWY S Parcel Number: 292104 9074 Project Description: SGN-Install freestanding(pedestal)sign. Owner Applicant Contractor SPRING VALLEY MONTESSORI FEDERAL WAY SIGN CO FEDERAL WAY SIGN CO 36605 PACIFIC HWY S FEDERAL WAY SIGN CO FEDERAL WAY SIGN CO FEDERAL WAY WA 98003 30665 MILITARY RD S 30665 MILITARY RD S AUBURN WA 98001 (253)529-2011 s; 110 — /// l s- Comprehensive Plan Designation SF-Low-Density Residential Zoning Designation RS 35.0 Free Standing Signs Registration# Sign Type Illuminated #Sign Setback Sign Face Sign Face Sign Height Base Height Landscape Area Faces (Ft.) Width(Ft.) Height(Ft.) (Ft.) (Ft.) (Sq.Ft.) A 01-0246 Pedestal 1 15 4 6 10 4 60 CONDITIONS: 1.This permit is issued based on the information provided by the applicant.Since property lines cannot be verified without a survey,the property owner,his/her heirs or assigns shall assume all liability for any relocation or any other associated costs should the sign be located in public right-of-way or within the required yard setback. 2.The required setback from property lines for all signs shall be not less than 5'in residential zones and not less than 3' in all other zones. 3.Sign base shall be made of solid materials harmonious with the character of the primary structures on the subject property.There shall be no visible gap between the sign base&finished grade for all monument&pedestal signs,per FWCC,Sec.22-1602(3)(I). 4.FINAL SIGN INSPECTION IS REQUIRED in order to receive the sign registration sticker.Please call 253-835-3050 to schedule the inspection. PERMIT EXPIRES April 29,2002,IF NO WORK IS STARTED. Permit issued on October 31,2001 I hereby certify that the above information is correct and that the construction on the above described propert! the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washingt. the City of Federal Way. Owner or agent: Date: (0.6Q \ O l 1101r— 1 .0 aro"' QIGN PERMIT APPLICATION • •OCT 18 2001 �� �Ef�L APPLICATION NUMBER: OL - 101034- (, Giill BUILDING DEPT. VAY 77 **The following is required information-Please print(in ink)or type** • PROPERTY INFORMATION 3G 6 o s Tca.e.. 414"ua;, • Q_L. LO SITE ADDRESS: a C? $Oo'S ASSESSOR'S TAX/PARCEL #: - LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY): • PRO3ECT INFORMATION TYPE OF PROJECT(Check all that apply): ❑ PERMANENT ❑ TEMPORARY giNEW ❑ ALTERATION ❑ REFACE ❑ EXEMPT NUMBER OF SIGNS APPLIED FOR WITH THIS APPLICATION: I PROJECT DESCRIPTION (Provide detailed description): (1-4.4-4r- 1).-9-0/4)44 "7Y BUSINESS/TENANT NAME: eR--1OJC Vh 1'l-Ey t}40IiTe"-I'S-0 IR,i L. -Om L, - ■ PEOPLE INFORMATION • SIGN OWNER: NAME U� ^ DAYTIME PHONE MAILING ADDRESS(STREET DDRESS,CITY,S i i E,ZIP) 3“, o ?o -. Co . cat- . UOC11 ./ W °r g Op CITY OF FEDERAL WAY BUSINESS LICEN E UMBER ' U EXPIRATION DATE / CONTRACTOR: NAME_ DAYTIME PHONE CA • ( 2S3) r'°--9 - t t MAILING ADDRESS(STREET ADDRESS;CITY, TE,ZIIEVENING PHONE: 3b6ro5 1A..t.A.0—(- ,t-% Pot . _e-, /WA-CIROo1 (.9 ) CITY OF FEDERAL WAY BUSINESS LICENSE NUMBta FAX NUMBER - - ( ) CONTRACTOR'S REGISTRATION NUMBER' EXPIRATION DATE. (Copy required) -FPe RW. 1 ( O J I. 3 142-'2- / `1-061 APPLICANT: NAME DAYTIME PHONE /1.w..Qom,,,,, ( ) - MAILING ADDRESS(STREET ADDRESS,CITY,STATE,ZIP) EVENING PHONE S-aL t.u.C_ o ( ) FAX NUMBER CONTACT FOR THIS PROJECT: ( ) ❑ PROPERTY OWNER ❑ APPLICANT / 3ONTRACTOR E-MAIL ADDRESS: _ - ' '- ; ■ **TEMPORARY SIGN APPLICATIONS ONLY** •. ' TYPE/PURPOSE OF EVENT: DATE OF INSTALLATION: DATE OF REMOVAL: TEMPORARY SIGN TYPE: ❑ BANNER ❑ INFLATABLE ❑ PORTABLE ❑ SEARCH LIGHTS/BEACON NUMBER OF EACH TYPE: • PRO3ECT DETAILS PROPOSED NUMBER OF WALL SIGNS: r---, PROPOSED NUMBER OF FREE STANDING SIGNS: TOTAL ESTIMATED PROJECT COST: $ ( 100 r--- NUMBER OF TENANTS/BUSINESS SPACES ON PROPERTY: 1 i 1 • TYPE OF SIGN(S)(Check all that apply) PERMANENT FREE STANDING: El MONUMENT ❑ OTHER PEDESTAL ❑ POLE ❑ TENANT DIRECTORY NUMBER OF EACH TYPE: 1 PERMANENT BUILDING MOUNTED:El AWNING ❑CABINET El CANOPY ❑ CENTER IDENTIFICATION(CID)El CHANNEL LETTERS NUMBER OF EACH TYPE: ❑ MARQUEE ❑ OTHER El PROJECTING ❑ TENANT DIRECTORY NUMBER OF EACH TYPE: - • ■ DETAILED SIGN INFORMATION • FREE STANDING SIGN SIGN AREA(SQ.FT.) ILLUMINATED?: REFACE? PART OF CID TOTAL SIGN BASE TYPE WIDTH X HEIGHT X#OF FACES NOI NFt XT IFESlNO SIGN? HEIGHT(FT) HEIGHT(FT) A on eJ 2-Lk- -1A-Ar o tt C STREET FRONTAGE(FT): BUILDING MOUNTED ILLUMINATED? SIGN AREA(SQ.FT.) BUILDING EXPOSED BUILDING SIGN TYPE NO/INTERNAL/EXTERNAL WIDTH X HEIG #OF FACES ELEVATION(N,S,E,W) FACE(SQ.FT.) A • DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by t owner of the above premises to perform the work for which the permit application is made d ( $ 20 n NAME/TITLE: � DATE: I - — SIGNATURE�, / � NAME(Print) � `1 LA PRINT FOR OFFICE USE ONLY: I ZONING DESIGNATION: _XS 3C5'.0 COMP PLAN DESIGNATION: .S F Lino BUILDING MOUNTED SIGN FREE STANDING SIGN AR a• • RMITTED: AREA PERMITTED: AREA PROPO • AREA PROPOSED: a l LARGEST BUILD • G FAc• : : STREET FRONTAGE: ! 3 70 NUMBER O• IGNS ALLOWED: NUMBER OF SI9NS ALLOWED: _ I LAND USE APPROVER INITIALS: /_ S DATE: lb - 3 b -O 1 STRUCTURAL APPROVER INITIALS: - DATE: I 0- _ •I REGISTRATION NUMBER: REGISTRATION NUMBER: Q I • o zy c. REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•P.O.BOX 9718•FEDERAL WAY,WA 98003-6221•(253)661-4000• FAX:(253)661-4129 rr SIGN PERMIT APPLICATION LI CHEC C ST ALL INFORMATION MUST BE PROVIDED BEFORE THE APPLICATION WILL BE ACCEPTED. Plans shall be of sufficient clarity to indicate the locations, nature and extent of the work proposed and show that it will conform to the provisions of the adopted Land Use and Uniform Codes and ordinances. Plan sheets must be 24" x 36". Minimum scale as indicated is required. 2 (two) COMPLETE SETS of plans must be submitted with each application. ■ REQUIRED DOCUMENTS ❑ COMPLETE PERMIT APPLICATION ❑ SITE PLAN ❑ ELEVATION PLAN ■ SITE PLAN • ❑ Scale (1"= 20') ❑ Location of ALL proposed signs, including refaces ❑ North arrow ❑ Alpha labeling of each sign consistent with application ❑ Property lines and building footprint ❑ Location of all existing signs to remain ❑ Location of suite, if multi-tenant ❑ Location of all existing signs to be removed ❑ OTHER ITEMS APPLICABLE TO NEW OR ALTERED FREE-STANDING SIGNS ONLY ■ ELEVATION PLAN BUILDING-MOUNTED SIGNS (See Figures 2A, 2B, 3, and 4) ❑ Scale (1/8"= 1', details 1/4"= 1') ❑ Dimensions of proposed signs ❑ Location of existing and proposed signs 0 Sign materials, color and illumination type ❑ Location of existing signs to be removed 0 Alpha labeling of sign consistent with application ❑ Dimensions of existing signs to remain on each façade ❑ Cross-section showing scaled width of sign: if canopy or awning, show entire building including awning/canopy and color scheme ❑ Dimensions of each building face or suite façade ❑ Actual weight of sign ❑ Calculated total building face square footage ❑ Method of attachment, size/type of connector AND ❑ Calculated total area of individual letter, number, etc., OR ❑ Site-specific installation details (what sign is attached calculated total sign face square footage to in field), placement and construction FREE-STANDING SIGNS (See Figure 5 and 6) El Scale (1/8"= 1', details 1/4"= 1') ❑ Calculated total panel area square footage, reface only ❑ Sign materials and color ❑ Sign base dimensions and finished grade El Sign face dimensions ❑ Alpha labeling of sign consistent with application ❑ Panel dimensions, reface only ❑ OTHER ITEMS APPLICABLE TO NEW OR ALTERED FREE-STANDING SIGNS ONLY • **NEW OR ALTERED FREE STANDING SIGNS ONLY** ALL PLANS AND DETAILS MUST BE TO SCALE SITE/LANDSCAPE PLAN DETAILS (minimum scale 1"= 20') ❑ Footprint and dimensions of sign 0 Show location of driveway and street ❑ Setbacks from property line(s) ❑ Footprint and dimensions of landscape area El Delineate edge of pavement ❑ Location of vegetation within landscape area ❑ Show point of measurement for location of property ❑ Type of landscape vegetation line(s) using fog-line, sidewalk, and/or edge of pavement El Calculated landscape area (minus footprint of sign) ELEVATION PLAN DETAILS (minimum scale 1/8"= 1') Construction details to include: ❑ base materials&how harmonious? 0 foundation type ❑ wind load calculations, if over 6' tall (Figure 6) Cross-section sign details to include: ❑ total sign height from average ground elevation ❑ edge of landscaping area El grade surrounding sign ❑ Existing and finished grades 0 Calculated total sign area square footage -- .- II+-4"` -- , 1 7 Zs, SOI CITY OF FE I E-AL WAY .6itialii- 6-ir 1411 DEPT. OF COMMU ITY DEVELOPMENT 74 �, �`It tiwYTS 01404031-00-SG ' eV() PEDESTAL SIGN 3 ,, 4- SPRING VALLEY MONTESSORI 10/18/01 DATE SUBMITTED /0-/, 0 I DATE APPROVED/o -/ 6 '�� • 44 [APPROVED BYAT �� 'Ci. lei.bi l'Aiktc-%v.)c. 'I!, r ILE it-A 44 a 0.___ ;77CD –36 - p( 1.,' ' o u a, �M E.X.1gr ItEAP6RE5o/UZD �1�_�_,T, LI » S+�u ' 147-�*1oi O 8• Ko r-oSE I> Stat °"." • FINAL SIGN INSPECTION I '/ REQUIRED IN ORDER TO 41,4 # I-2.-3- it-5- G-i- -g RECEIVE SIGN REGIST ON .1, Exist. SSvILDIoas NUMBER. CALL 253-8 - 150 TO RECEIVED SCHEDULE INSPECT - -- -- - OCT 18 7rrpi 1-3 E1 VII 7 ur —.._; _WVK i BUILDING DEPT, S+-[t. 'LA►4 /Sri?..% VP LL.EY MotJTES.So ( 5c -. / SG : I" too` , ��p80SED SIGN It IA (2.' SCZ fir) / Ia ( jr. LANDScA 'ED ARCA .i (C.o Sq IFT) �' ei SttR.,vgs 4.1 J? AL zze • t - _ ; ki w�Y '.. -; inimum of 50% of the required landscaped iZ, ea should be planted with low shrubs & groundcover such that within 2 years, 90% of the landscaped area is covered. If all grasses are to be used, landscaped area must be covered 100% at time of planting. s e area jent to the base ofRECEIVED gn each freestandingadacsot ibe lanThdscaped equal to themust sign OCT 1 8 2001 area. CITY OF FEDERAL WAY BUILDING u 'PT. STTB/rL6C. t_ LAN sch 'U DETAILS / Srik.1M VALLEY hONT�SSoR.► / Sc: I" = 10� tiht-v" 0 h. s TEE L.. 'F.RA11 E vl X 3" ..r.0 et Ns; S t Po 1.! 'PiN W E 1,., SIGN /RRE 0 (. /s!. 1'lDO ?LYWop) I Zit sa FT l9 C'+) BRAc44... "s. vw/ /& o ccR.EWS I a __I_. STEM_ Tive 75 Li.' i SI p.) BAs , 0 (M14TE�..t I h 1... C.a,t..oR 011 t.N6. g,1..A4,s i g:Ji Iv ,rig 1" Lvaii ,►o . : 1-1 = wcivr. ateAte r 0 .? 0 0. I , ,,,, ..v....) . . 0 lVC6°> 4 r co; g,; low 1 i ...ad c.--- ZC ' ;Ti 0 co ..... (gASE) I r. ' yr 1� 5R in V ?Epee-rpm_ I SuN6LE. 'hc Sl'N W tTh{ '?L:(wooD Sign base shall be made of solid materials PA►J EL. harmonious with the character of the primary structures on subject property& there shall be no visible gap between sign base& finished grade for all monument& festal sigts.(FWCC Sec 22-1602(3XI)) TEIDESTAi... SIrcN IAAw/ P IW C. VA 1.-1..e%( 1-i0141e-M,Mt / SC: 1" = 2: • I A O Q. _A� J I o c4 INIIMMIal 2 C, >w■ Ofp 0 o MMI � in a ,- ,: A ,� C) Rj 4 = J MI :r 1— _ Om Q in M Vtil tii CO in Ii z J M 3 - s r a H ad 4 Q s ho— b9 O = R EC F!\' v-) 2 (11Y 01=r Ei:�ri::i.vvn Y BUILDING DEPT, a�crE'r^V�rJie@710]�.T, '::r- ..- - .--", i .. ----- _ i%. iet: Eii33 r.Lw:;.rr sEiri .:rn I �..oi([EiliL:;Center Pole n Installatio - Base r c _u N_ ;NN .. •+Tt*i rTY ,l :.T-�.-rf..}w r . fti+alF•Fa1•�i.. 4..1Calculation Factors I1 u-u I:L-, i•- -1 --'H ,-I I ' I ic_.-[2:"'t"-,. T:,..1-i-ITlxCT 1. Height(H) tot Width(W) 4' Area (A) 40 2. Design Wind Pressure (PSF) Exposure B= 8o KQtt @ 'I.5 Height above ground. P = PSF(see below) 16.- x(A) 4-o = GG 8- Lbs. Pressure(PSF)/Height Factor -., 0-20'= 16.7 20'-40'= 19.0 40'-60'=23.8 y= :T 60'- 100'=26.2 100'- 150'=30.9 150'- 200'=33.3 9 � . s� ��� 3. Hei ht to center of windload (H)�:_ 4. Bending Moment(M) _ (P) 6 8 x(H) S'4 N 1bs ..-._s :� o.:'i5. Section Modulus(Sx) = M x 12 = 60, tZo = 2.8 0=_=- --- 1.33x16x"..:7".:::._,:.71:":,....,...,:..,.. - -= `=. , 1000 2I , 2 O Sx Definitions: j 12-Factor to change to inches 1.33- Windload factor(UBC) t 16-Steel Standard Factor 1000-Factor(Engineering) Sign Sketch Base Schedule Standard Pipe F_-i.51/BISREr3 Gea rrx .--...--..:;^ _T�:: itr:ii.:;Iii:1HEEHE HEEIEBER - T Pipe Size Thickness Measure -A Measure;'B Pipe Size Weight per ft. Sect. Mod. 2" .0154" 1'6" 2' 2" 3.652 .5606 3" .216" 1'6" 2' 6" 3" 7.575 1.724 X;'O .0257 '': .1'6" ,f.i(7).- _.....,..) co 10.790 3.214 ao z c) � 6" .290" 2' 4'S.. 6" 18.974 =.49b GT '''" 8" .277" 3' 8" - 23.554 16.81 v c;; a° 10" .297" 3' 6' m--. '': - 10"--.'*\ 34.240 25.57 'sI 12" .330 4' 7' 12 ' 43.773 38.97 I A I fi A- B A n x A x — . . • , i