13-105329Project Name: WYNSTONE EAST LOT 80
Project Address: 1020 SW 338TH ST
4#uildimg -=-Single Family
Permit #: 13 -105329 -00 -SF
Inspection Request Line: (253) 835,3050
Parcel Number: 957850 0800
Project Description: NEW - Construction of a 2,650 square foot 2 -story single family residence with a 256
square foot covered entry and a 737 square foot attached garage. Includes plumbing &
mechanical
***4 Bedrooms; $399,950 estimated selling price.***
Owner
Applicant
Contractor
Lender
LENNAR NORTHWEST INC
LENNAR NORTHWEST INC
City of Federal Way
OWNER IS LENDER
Community & Econ. Dev. Services
33325 8th Ave S
12815 CANYON RD E SUITE F
Federal Way, WA 98003
FILE
Ph: (253) 835-2607 Fax: (253) 835-2609
PUYALLUP WA 98373
Project Name: WYNSTONE EAST LOT 80
Project Address: 1020 SW 338TH ST
4#uildimg -=-Single Family
Permit #: 13 -105329 -00 -SF
Inspection Request Line: (253) 835,3050
Parcel Number: 957850 0800
Project Description: NEW - Construction of a 2,650 square foot 2 -story single family residence with a 256
square foot covered entry and a 737 square foot attached garage. Includes plumbing &
mechanical
***4 Bedrooms; $399,950 estimated selling price.***
Owner
Applicant
Contractor
Lender
LENNAR NORTHWEST INC
LENNAR NORTHWEST INC
LENNAR NORTHWEST INC
OWNER IS LENDER
12815 CANYON RD E SUITE F
12815 CANYON RD E SUITE F
LENNAN1893QG (11/7/15)
PUYALLUP WA 98373
PUYALLUP WA 98373
12815 CANYON RD E SUITE F
Residence (1 or 2
family)
PUYALLUP WA 98373
Census Category: 101- New Single Family House
Includes:
#1 #2 #3 #4
Occupancy Class:
R-3
Construction Type:
Type V - B
Occupancy Load
V - B
Floor Areas . ft.
2,650 1 0 1 0 1 0
Additional Permit Information
New / Additional Sq. Feet - 1 st Floor....................1066
New / Additional Sq. Feet - 3rd Floor....................0
New / Additional Sq. Feet - Basement...................0
Occupancy #I - Construction Type ........................Type
V - B
New / Additional Sq. Feet - Garage .......................737
Occupancy # 1 -Class .............................................R-3
Plumbing to be Included?.......................................Yes
Occupancy # I -Use ...............................................
Residence (1 or 2
family)
New / Additional Sq. Feet - 2nd Floor...................1584
Occupancy # I - Area (Sq. Feet).............................2650
BasicPlan?........................................................... No
New / Additional Sq. Feet - Deck .........................0
Mechanical to be Included?...................................Yes
New / Additional Sq. Feet - Other..........................0
New / Additional Sq. Feet - Total .......................... 3387
Zoning Designation...............................................RM 3600
Mechanical Fixtures
Fans.................p............................... 7 Fireplace Inserts ..........................I Furnaces......................................... 1
Gas Piping ...................................... 5 Hot Water Tanks.................
Plumbing'
Bathtubs ......................................... 2 Dishw .. ...................... 1 Laundry Washer Outlets ............... 1
Lavatories ....................................... 5 Showers. ...................................... 1 Sinks................................:... 1
Water Closets ................................. 3 Hose Bibbs............ . ..................... 3
PERMIT EXPIRES Monday, September 8, 2014
Permit Issued on Wednesday, March 12, 2014
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and the Q!deral Way.
Owner or agent. Date: �'
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that
at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building
construction or use. This certificate is valid ONLY when endorsed by City staff.
Tenant Name: WYNSTONE EAST LOT 80
Address: 1020 SW 338TH ST
Permit #: 13 -105329 -00 -SF
Includes:
#1 #2 #3 #4
Occupancy Class:
R-3
Construction Type:
Type V - B
Occupancy Load:
Floor Area (sq. ft.)
2,650 0 0 1 0
Owner Name: LENNAR NORTHWEST INC
Owner Address: 12815 CANYON RD E SUITE F
PUYALLUP WA 98373
Building Official
(m -t
I (q -
Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severly affect the health and safety of the general public. Although the City has made as complete a
review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor
warrants to the owner / occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which itis situated. Such compliance is the responsibility of the owner and / or occupant of the premises.
a�
CITY OF
Federal Way
PERMIT #:
Project:
THIS CARD IS TOMAIN ON-SITE
Construction In ction Record
INSPECTION REQUE TS: (253) 835-3050
13 -105329 -00 -SF Address: 1020 SW 338TH ST
LENNAR NORTHWEST INC FEDERAL WAY, WA 98023
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
Foundation Wall (4115)
Approved to place concrete
By Date
Slab/Concrete Floor (4255)
Approved to place concrete
By Date
Shear Walls (4245)
Approved to install siding
Date 7 \ \
Mechanical Rough -in (4165)
Approved
By Date
11 Interim Erosion Control (4370)
Approved
By Date
Insulation (4150)
Approved to install wallboard
By Date 811 (tit
o Final - Mechanical (4065)
Approved
By Date A 2 /'-7
❑ Drainage/Downspout (4040) Plumbing Groundwork (4190)
Approved to backfill Approved to cover
By Nt Date S- yc(, ly By Date
Underfloor Framing (4285)
Approved to sheath floor
Byes Date
Roof Sheathing (4220)
Approved to install roofing
B Date
Gas Piping (41Z
Approved to release test
By A 4 Date rl
Prior to scheduling a Framing inspection;
Electrical, Plumbing & Mechanical Rough -in and
FireMraft Stop inspections must be signed -off and
approved. IBC 109.3.4
Gypsum Wallboard Nailing (4130)
Approved to install mud & tape
By Ind Date f; (S-
Final
SFinal - Plumbing (4075)
Approved
By 495 Date /'a/Z
❑ moor sheatning (41Ut�)
Approved to install flooring
By , I Date
Rough Plumbing (4230)
Approved
By (),,&, Date i�2,e.-1u
Fire/Draft Stops (4095)
Approved
By Date
Framing (4120)
Approved to insulate
By Date -7 o I q
El Final Erosion Control (4375)
Approved
By Date
Final - Building (4050)
Approved
By M Date t o -7 1 �
❑
SWM Precon Site Mtg (4400)
Initial Erosion Control (4365)
Final Electrical1:1Right
Approved
Footings/Setback (4110)
of Way
Approved
Approved
Date
To be done prior to breaking ground
By V-0
Approved to place concrete
By
Date
By
Date
By
VI -6 Date S' 1-11%4
Foundation Wall (4115)
Approved to place concrete
By Date
Slab/Concrete Floor (4255)
Approved to place concrete
By Date
Shear Walls (4245)
Approved to install siding
Date 7 \ \
Mechanical Rough -in (4165)
Approved
By Date
11 Interim Erosion Control (4370)
Approved
By Date
Insulation (4150)
Approved to install wallboard
By Date 811 (tit
o Final - Mechanical (4065)
Approved
By Date A 2 /'-7
❑ Drainage/Downspout (4040) Plumbing Groundwork (4190)
Approved to backfill Approved to cover
By Nt Date S- yc(, ly By Date
Underfloor Framing (4285)
Approved to sheath floor
Byes Date
Roof Sheathing (4220)
Approved to install roofing
B Date
Gas Piping (41Z
Approved to release test
By A 4 Date rl
Prior to scheduling a Framing inspection;
Electrical, Plumbing & Mechanical Rough -in and
FireMraft Stop inspections must be signed -off and
approved. IBC 109.3.4
Gypsum Wallboard Nailing (4130)
Approved to install mud & tape
By Ind Date f; (S-
Final
SFinal - Plumbing (4075)
Approved
By 495 Date /'a/Z
❑ moor sheatning (41Ut�)
Approved to install flooring
By , I Date
Rough Plumbing (4230)
Approved
By (),,&, Date i�2,e.-1u
Fire/Draft Stops (4095)
Approved
By Date
Framing (4120)
Approved to insulate
By Date -7 o I q
El Final Erosion Control (4375)
Approved
By Date
Final - Building (4050)
Approved
By M Date t o -7 1 �
❑
Rough Electrical
Approved
❑
Final Electrical1:1Right
Approved
of Way
Approved
By
Date
By V-0
Date to `'t I (�
By
Date
Cny of 7'&
Federal Way
PERMIT NUMBER 1
PERM IVAPPLICATION
RECEIVED
10 2 NOV 2$ 2013
iZ' L7�5
_c4:p( of -FEDERAL \NUGET DATE
4y`
rns
SITE ADDRESS O Sw — O
SUITE/UNIT N
PROJECT VALUATION
$
ZONING
ASSESSOR'S TAX/PARCEL �
9c�8o d
TYPE OF PERMIT
BUILDING PLUMBING a MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
63V '- 80
Construction of new SFR
PROJECT DESCRIPTION
Detailed description of work to
be included on this permit only
NAME
PRIMARY PHONE
PROPERTY OWNER
Lennar NorthWest
253-590-2200
MAILING ADDRESS
12815 Canyon Road E, Suite F
E-MAIL
Marijke.VanStichel@Lennar.com
CITY
Puyallup
STATE
WA
ZIP
98373
NAME
PHONE
Lennar NorthWest
253-590-2200
MAILING ADDRESS
E-MAIL
CONTRACTOR
12815 Canyon Road E, Suite F
Marijke.VanStichel@Lennar.com
CITY
STATE
ZIP
FAX
Puyallup
WA
98373
253-446-6751
WA STATE CONTRACTOR'S LICENSE k
EXPIRATION DATE
FEDERAL WAY BUSINESS LICENSE N
LENNAN1893QG
S
NAME
PRIMARY PHONE
Lennar NorthWest
253-590-2200
APPLICANT
MAILING ADDRESS
12815 Canyon Road E, Suite F
E-MAIL
Marijke.VanStichel@Lennar.com
CITY
STATE
ZIP
FAX
Puyallup
WA
98373
253-446-6751
NAME
PRIMARY PHONE
PROJECT CONTACT
Marijke Van Stichel
253-590-2205
MAILING ADDRESS
12815 Canyon Road E, suite F
E-MAIL
Marijke.VanStichel@Lennar.com
(The individual to receive and
respond to all correspondence
CITY
STATE
ZIP
FAX
concerning this application)
Puyallup
WA
98373
253-446-6751
PROJECT FINANCING
N)A E
OWNER -FINANCED
Required value of $5, 000 or more
(RCW 19.27.095)
MAILING ADDRESS, CITY, STATE, ZIP
PHONE
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claim), which may be made by any person, including the undersigned, andfiled against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as a s application.
i 1
SIGNATURE: DATE
PRINT NAME: 81ijke Van lchel
Bulletin #100 — January 1, 2013 Page 1 of 3 k:\landouts\Permit Application
J
4
MECHANICAL PERMIT
CRITICAL AREAS ON PROPERTY?
WATER PURVEYOR
-NNW
VALUE OF MECHANICAL WORK
$
Indicate how many of each type of
fixture
to be installed or relocated as part of this project. Do not include existing fixtures to remain.
AIR HANDLING UNITS
7
FANS
GAS PIPE OUTLETS OTHER (Describe)
AIR CONDITIONER
I 66
FIREPLACE INSERTS
HOODS (commercial)
BOILERS
�_
FURNACES
�_ HOT WATER TANKS (Gas)
COMPRESSORS
LAVS (H—ds-k.)
GAS LOG SETS
REFRIGERATION SYST
153UCTING
ADDITION
GAS PIPING
WOODSTOVES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY?
WATER PURVEYOR
SEWER PURVEYOR
/, pv/J���/^,
VALUE OF PLUMBING WORK
PLUMBING PERMIT
LOT SIZE (In Square Feet)
EXISTING FIRE SPRINKLER SYSTEM?
❑ Yes "Go
PROPOSED FIRE SUPPRESSION SYSTEM?
❑ Yes O(Vo
a
FIRST FLOOR (or Mobile Home)
I 66
$
Indicate how many of each type of
fixture
to be installed or relocated as
part of this project. Do not include existing fixtures to remain.
BATHTUBS (or Tub/shower combo)
r
LAVS (H—ds-k.)
TOILETS
WATER PIPING
DISHWASHERS
ADDITION
RAINWATER SYSTEMS
URINALS
OTHER (Describe)
DRAINS
SHOWERS
VACUUM BREAKERS
7 17
DRINKING FOUNTAINS
Construction
SINKS (Kiwhe /Utdzty)
WATER HEATERS (Eteetnc)
HOSE BIBBS
SUMPS
WASHING MACHINES
I / TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY?
WATER PURVEYOR
SEWER PURVEYOR
/, pv/J���/^,
VALUE OF EXISTING IMPROVEMENTS
EXISTING/PREVIOUS USE
N6
LOT SIZE (In Square Feet)
EXISTING FIRE SPRINKLER SYSTEM?
❑ Yes "Go
PROPOSED FIRE SUPPRESSION SYSTEM?
❑ Yes O(Vo
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION (in square feet)
EXISTING
PROPOSED
TOTAL
FOR OFFICE USE
BASEMENt
in Square Feet
a
FIRST FLOOR (or Mobile Home)
I 66
106 6
SEC'0ND Ft oar '
y
f214
COVERED ENTRY
ADDITION
DECK ;
`:7
GARAGE N CARPORT ❑
AREA DESCRIPTION
7 17
73 -7
Construction
OTHER (dGsctiii£
Additional Information
in Square Feet
Area Totals
STING
PROPOSED
e-13
TOTAL
361
.
ESTIMATED SELLING PRICE $ /SQ
# OF BEDROOMS 1
COMMERCIAL — NEW/ADDITION N/A
AREA DESCRIPTION
Area
Occupancy Group(s)
Construction
# of
Additional Information
in Square Feet
a
Stories
RL9q BUILItflt
ADDITION
COMMERCIAL — REMODEUTENANT IMPROVEMENTS N/A
AREA DESCRIPTION
Area
Occupancy Group(s)
Construction
# of
Additional Information
in Square Feet
a
Stories
l
.
TOTAL. 0#LDIPG
'=3'�
,�:. } -^~! fir
.:Y--.
.£'�
t - :'.:yp;.i"
.J. 'f k"` " •2
TENANT AREA ONLY
"
"?Y i
Bulletin #100 - January 1, 2013 Page 2 of 3 k:\Handouts\Permit Application
PROPERTY/LOT LINE
RIGHT OF WAY LINE
ROAD CENTERLINE WALL
EDGE OF PAVING/CURB LINE DRAIN
SDCO To'ROOF DOWNSPOUT
CONTOUR LINE PSDE CONNECTION
STORM DRAIN CATCH BASIN yyA2'x70' PERFORATED PIPE CONNECTION TRENCH
Sg PER 2009 KC SWDM FIGURE C.2.11.A APPROX.
STORM DRAIN LINE –1 SO', LOCATION, CONTRACTOR TO FIELD LOCATE
SANITARY SEWER MANHOLE SDCO
SANITARY SEWER LINE
SANITARY SIDE SEWER LINE VIONTY MAP
10, SD
CLEAN OUT
2' HIGH MAX.rr COPE `'----------
WATER METER %WM KEYSTONE -P,4
GRAVITY WALL 51 1
WATER MAIN LINE
FIRE HYDRANT
FH f
40, 5, 1 Pl'
AIR VACUUM VALVE ASSEMBLY 11, 'iik g "a"ggg"00,
x"'6w,T=201
NATURAL GAS STUB C LOT 81
LOT 80lo-
),
POWER STUB OP 2650C /q
91
CONCRETE h, 0)p, g ,q
NEW IMPERVIOUS/DRIVEWAY F 1� EAVE
LOT 79
"i'll
ig�lv
ROOF DOWNSPOUT CONNECTION ------+------ GARAGE R zci,�
RETAINING WALL
20' GARAGE �'p
POINT OF MEASUREMENT.j `25 PCRGH SETBACK
0 POWER STUB
POINT OF ELEVATION rn (APPROX
LOCATION)
SILT FENCE WA
GAS STUBSS 'N
LOT SIZE = 5,169 S (APPROX
LOCATION)
G P
IMPERVIOUS COVERAGE: LOT ADDRESS:
-N—OTE,
TOTAL IMPERVIOUS: 2,840 SE (54.9%) 1020 SW 338TH STREET ANY PORTIONS OF STRUCTURES WITH
FEDERAL WAY, WA 98023 m1e Y`
LESS THAN 10–FEET OF SEPARATION
ROOF: 2,319 SF Kp a g r SHALL BE FIRE RATED.
DRIVEWAY: 439 SF LEGAL DESCRIPTIO
--TED
WALKWAY: 36 SF LOT 80 OF THE PLAT OF POWER VAULT- LATEROW
PATIO: 46 SF WYNSTONE EAST, RECORDED (APPROX LOCATION) R=125.00
UNDER AUDITOR'S FILE NO. INSTALL SILT A--24*21' 8"
BSBL 20121205001817, RECORDS FENCE AS SHOWN 6 2014
FRONT: 10' OF KING COUNTY, L=53.5
GARAGE: 20' FROM III WASHINGTON. CITY OF FEDERAL WAY
SIDE: 5' CPS
REAR: 5'
SW 338TH STREET HOUSE PLAN # 2650C
0.;O.d SMS Scale: G14A(j 18215 72ND AVENUE SOUTH For: Till Job Number
IV - 0, e: RESIDENTIAL SITE PLAN
D—n iu Horizontal KENT, WA 98032 LENNAR NORTHWEST INC. 16305
(425)251-6222 WYNSTONE-LOT 80
Cb.k� Ws (425)251-8782 FAX 12815 CANYON RD E, STE F
Shoot
PUYALLUP, WA 98327 PARCEL 957850-0800
Appr"` 1p CIVIL ENGINEERING, LAND PLANNING,
HIA SURVEYING, ENVIRONMENTAL SERVICES
Dw� NG11�10' (253) 590-2205
File:P:\16000s\16305\lots\16305–Wynstone Lots.dwg Plot Date/Tirne:11/5/2013 4:34 PM BSCHWARTZ
z4-