Loading...
12-101197 ay • •uilding - ging* family Community CFederalof&Eco^.Dev.Services Permit #: 12-101197-00-SF 33325 8th Ave S Federal Way,WA 98003 2 ec53 inspection Request Line: Ph:(253)835-2607 Fax:(253)835-2609 -� p � )835-3050 1 L .-•_may Project Name: SAGHALIE FIRS LOT Project Address: 1931 SW 341ST PL Parcel Number: 750380 0240 Project Description: NEW-Construction of a new 1,640 square foot,2-story single-family residence,with a 56 square foot covered entry and a 367 square foot attached garage,including plumbing and mechanical work. No deck.****4 bedrooms;Estimated selling price$259,995**** BASIC#11-100570 • Owner Applicant Contractor Lender SSHILLC DBA D R HORTON INC SSHI LLC DBA D R HORTON INC D R HORTON SSHI LLC DBA D R HORTON INC 12931 NE 126TH PL 12931 NE 126TH PL DRHOR**963CS(8/3/12) 12931 NE 126TH PL KIRKLAND WA 98034 KIRKLAND WA 98034 12931 NE 126TH PL KIRKLAND WA 98034 KIRKLAND WA 98034 Census Category: 101 -New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load Floor Area(sq.ft.) 1,696 0 0 0 Additional Permit Information New/Additional Sq.Feet-1st Floor 721 New/Additional Sq.Feet-2nd Floor 919 New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 1696 New/Additional Sq.Feet-Basement 0 Basic Plan? No Occupancy#1-Construction Type. Type V-B New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 367 Mechanical to be Included? Yes Occupancy#1-Class R-3 New/Additional Sq.Feet-Other 56 Plumbing to be Included? Yes New/Additional Sq.Feet-Total 2063 Occupancy#1-Use Residence(1 or 2 Zoning Designation. RS 7.2 family) Mechanical Fixtures Fans 4 Fireplace Inserts 1 Furnaces 1 Gas Piping 4 Hot Water Tanks. 1 Plumbing Fixtures Bathtubs 1 Dishwashers 1 Laundry Washer Outlets. 1 Lavatories 4 Other Plumbing Fixtures. 1 Showers 1 Sinks 2 Water Closets 3 Hose Bibbs 2 CONDITIONS: 1)Roof drains must connect to existing drywells. Drywells overflow to public storm system. See details attached to plans. c oho s. FII A !'D 40102 c 06-0 s,./eJa, P(44-5 P'Ac 4 , . 4 PELT EXPIRES Tuesday, October 1.012 Permit Issued on Thursday,April 19, 20 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington andtheCity of Federal Way. (�hq Owner • -•- CL Q '( _ Date: r City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: SAGHALIE FIRS LOT 24 Permit#: 12-101197-00-SF Address: 1931 SW 341ST PL Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 1,696 0 0 0 Owner Name: SSHI LLC DBA D R HORTON INC Owner Address: 12931 NE 126TH PL KIRKLAND WA 98034 e 9 -- it- 1 Building Offi ial Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severly affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. • - ¶S ` r '4A , , THIS CARD IS TO'REMAIN ON-SITE , ' a ' Construction Inaction Record Federal WayINSPECTION RE UESTS: (253)835-3050 Q PERMIT#: 12-101197-00-SF Address: 1931 SW 341ST PL Project: SSHI LLC DBA D R HORTON INC FEDERAL WAY, WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ❑ SWM Precon Site Mtg(4400) 0 Initial Erosion Control(4365) 0 Footings/Setback(4110) Approved To be done prior to breaking ground Approved to place concrete By Date By Date CS Date L_ 7_ i Z 0 Foundation Wall(4115) 0 Drainage/Downspout(4040) ' Plumbing Groundwork(4190) Approved to place concrete Approved to backfill Approved to cover By jr-6iDate 6-/3-/2_ By /" Date ‘Vit•l2 By Date -0 Slab/Concrete Floor(4255) 0 Underfloor Framing(4285) .0 Floor Sheathing(4105) Approved to place concrete fl.p- to sheath floor Approved to install flooring By Date By /' `. Date 7,3-12_ By 1C f Date 7-/7-/7� ' 0 Shear Walls(4245) 0 Roof Sheathing(4220) .0 Rough Plumbing(4230) Approved to install siding Approved to install roofing Approved By ©10, _ Date n—.)._.,)—vz By f2," Date 7-/7-/2 By Q�_____ Date h_'L'1—t • -❑ Mechanical Rough-in(4165) 0 Gas Piping(4125) 0 Fire/Draft Stops(4095) Approved Approved to release test Approved By .. Date 7..j,{-(1._ By Date .1,247-/Z By 0 Date r1 `2r1--, '1 0 Interim Erosion Control(4370) Prior to scheduling a Framing inspection; , -13 Framing(4120) Approved Electrical,Plumbing&Mechanical Rough-in and Approved to insulate Fire/Draft Stop inspections must be signed-off and By Date approved. IBC 109.3.4 1 By Q---)fl J Date "WI 1` ❑ Insulation(4150) ❑Gypsum Wallboard Nailing(4130) 0 Final Erosion Control(4375) Approved to install wallboard Approved to install mud&tape Approved Bar Date _? ' By c Date _L_ ( By Date ❑ Final-Mechanical(4065) . 0 Final-Plumbing(4075) .El Final-Building(4050) Approved Approved Approved 1(...... Date 9—/efre, B67 Date --ie--1Z. B S Dater/&/'? ❑ Rough ElectricalID Final Electrical El Right of Way Approved Approved Approved By. Date By Date By Date . . • J t v N _ rn I 41 kt. 11 -7 (-7 _ - r _ _L_• Fede (f PERMIT MF C ME DE EN FP COMMUM7Y DEVELOPMENT SERVICES AP P LI CAT I O N 4 s 253-835-2607•FAX 253-835-2609 U Is 7 tu; wuru;.eituorrederaauMrAR l 1 SITE Ae Y OF FEDERAL WAY SUITE To 1931 SW mitt Place PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# 7 5 0 3 8 0 - 0 2 4 0 TYPE OF PERMIT X BUILDING 131 PLUMBING X MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT (Tenant Name/Homeowner Last Name) Saghalie Firs Lot 24 PROJECT DESCRIPTION New Construction - Single Family Residence Detailed description of work to Under Basic Plan 3705 - 11-100570-00-SF be included on this permit only NAME ---- PRIMARY PHONE - - PROPERTY OWNER SSHI, LLC dba D.R. Horton (425) 821-3400 MAILING ADDRESS E-MAIL 12931 NE 126th Place CITY STATE ZIP Kirkland WA 98034 -- NAME PHONE Same as property owner MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# DRHOR**963CS 08 03 12 20-10-101914-00-BL NAME PHONE Same as owner and contractor APPLICANT MAILING ADDRESS E-MAIL CITY STATE ZIP FAX PROJECT CONTACT NAME - - - PHONE (The individual to receive and Stephen Rarick (425) 821-3400 x5135 respond to all correspondence MAILING ADDRESS E-MAIL concerning this application) srarick@drhorton.com CITY STATE ZIP FAX (817)928-2067 ALTERNATE CONTACT NAME: PHONE E-MAIL PROJECT FINANCING NAMEOWNER-FINANCED Required value of$5,000 or more SSHI owns the lots-No lender (RCW 19.27.095) MAILING ADDRESS,CITY,STATE,ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to t city as a part of this application. SIGNATURE: DATE 3/12/12 PRINT NAME: Steph n Rarick Bulletin#100-January 1,2011 Page 1 of 3 k:\Handouts\Permit Application orP PLAN 3705 MECHANICAL FIXTURES VALUE OF MECHANICAL WORK $ (a copy of bid or estimate must be provided) Indicate how many of each type of fixlwe to be installed or relocated as part of this project. Do not include existing fixtures to remain. -- AIR HANDLING UNITS 4 FANS -- GAS PIPE OUTLETS OTHER(Describe) -- AIR CONDITIONER 1 FIREPLACE INSERTS -- HOODS(commerela(( -- BOILERS 1 FURNACES 1 HOT WATER TANKS(Gas( -- COMPRESSORS -- GAS LOG SETS REFRIGERATION SYST -- DUCTING 4 GAS PIPING -- WOODSTOVES PLUMBING FIXTURES Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. 1 BATHTUBS(or Tub/Shower Combo( 4 LAVS(Hand Sinks) 3 TOILLIb 1 WATER PIPING 1 DISHWASHERS -- RAINWATER SYSTEMS -- URINALS OTHER(Describe) -- DRAINS 1 SHOWERS -- VACUUM BREAKERS -- DRINKING FOUNTAINS 2 SINKS(wtchen/Utility) WATER HEATERS(Eictric) 2 HOSE BIBBS SUMPS 1 WASI-IING MACHINES 16 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS Lakehaven Utility Lakehaven Utility $ EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? 8,029 sf ❑Yes X No ❑Yes X No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT ' ____ ---- ---- FIRST FLOOR(or Mobile Home) ---- 721 721 SECOND FLOOR ---- 919 919 COVERED ENTRY ---- 56 56 DECK ---- ---_ _-..- — ---- GARAGE X CARPORT El car sf ---- 367 367 - OTHER(describe) ---- ---- ---- Area Totals ��G PROPOSEDTOTAL 2063 2063 "IVEW HOMES ONLY*" ESTIMATED SELLING PRICE$ 259,995 #OF BEDROOMS 4 COMMERCIAL—SEW/ADDITION AREA DESCRIPTION Area Occupancy Group(s) Construction #of Additional Information in Square Feet Type Stories NEW BUILDING ADDITION COMMERCIAL —REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area Occupancy Group(s) Construction #of Additional Information in Square Feet Type Stories TOTAL BUILDING TENANT AREA ONLY PROJECT ARPA ONLT Bulletin#100-January 1,2011 Page 2 of 3 101-Iandouts\Permit Application DATE: 2/14/12 PLAN: 3105-A-R 15045-24 N eV41'04" W 64.06' DRYINELL 5' 555L i 23'-4" I 328.5 329 2 I w ; ! DESIGN F.F. z { 0cli z I 42'-10" I rn 18.5f .. ._ N 3504TOq" W rye, 1_-_______________ .; SILT FENCE i.—.—.— _.—.—.—._ SW 341st PLACE NOTE5: U EXTERIOR CONCRETE AREA5 MAY VARY WF_ TO 5ITF CL WDITIONS p 5' UTILITY ESMT 10' UTILITY ESMT ARMRED NS TENTRANCE — 20' S55L RECEIVED ` 5 2012 LEGEND �4---- = SEWER MAIW5NB $- • - =W,TER MAIWMETER ------ = STORM MAIWSNB D 0% 0 Fn m n:� N) D Fn I (D A To T Q -f r 3 0 -i N - A