Loading...
13-102482' • K, fuilding - Si'nglt Family CityCommunity & Econ.FedeevWay S Permit #. 13 -102482 -00 -SF Community &Econ. Dev. Services 33325 8th Ave S ' Federal way' WA 98003 Inspection Request Line: 2 Ph: (253) 835-2607 Fax (253) 835-2609 P eq (53) 835-3050 Project Name: WYNSTONE EAST LOT 94 Project Address: 1101 SW 3391M ST Parcel Number: 957850 0940 Project Description: NEW - Construction of a 2,778 square foot 2 -story single family residence with basement, 334 square foot covered entry and 372 square foot attached garage. Includes plumbing & mechanicaL **4 Bedrooms; $361,950 estimated selling price** Owner Applicant Contractor Lender LENNAR NORTHWEST INC LENNAR NORTHWEST INC LENNAR NORTHWEST INC OWNER IS LENDER 12815 CANYON RD E SUITE F 12815 CANYON RD E SUITE F LENNANI893QG (11/7/15) R-3 PUYALLUP WA 98373 PUYALLUP WA 98373 12815 CANYON RD E SUITE F Residence (1 or 2 family) PUYALLUP WA 98373 Census Category: 101- New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type. Type V - B Occupancy Load- oadFloor FloorArea . ft. 3,484 1 0 1 0 1 0 Additional Permit Information New / Additional Sq. Feet - I st Floor....................1167 0 - New / Additional Sq. Feet - 3rd Floor.................... New / Additional Sq. Feet - Basement...................518 Occupancy #I - Construction Type ........................Type V - B New / Additional Sq. Feet - Garage ....................... 372 Plumbing Work Valuation?....................................7900 New / Additional Sq. Feet - Other ..........................334 New / Additional Sq. Feet - Total .......................... 3484 Zoning Designation...............................................RM 3600 Ducting........................................... Furnaces......................................... Hot Water Tanks. ........................... Bathtubs......................................... Lavatories ....................................... Water Closets ................................. 1 1 1 7 4 New / Additional Sq. Feet - 2nd Floor...................1093 Occupancy # 1 - Area (Sq. Feet).............................3484 BasicPlan?........................................................... No New / Additional Sq. Feet - Deck..........................0 Mechanical to be Included? .................................... es Occupancy # I - Class ............................................. R-3 Plumbing to be Included? ....................................... es Occupancy # 1 -Use ............................................... Residence (1 or 2 family) Mechanical Fixtures Fans........................:��.... Gas Piping........ ......... res Di s washers. .................................. Showers .......................................... Hose Bibbs..................................... 6 Fireplace Inserts ............................. 1 1 Gas Pipe Outlets ............................. 3 1 Laundry Washer Outlets ................' 1 2 Sinks ............................................... 1 2 PERMIT EXPIRES Saturday, June 28, 2014 Permit Issued on Monday, December 30, 2013 I hereby cbrtify that the above information is correct and that the construction 'on the above described property and the occupancy and the use will be' the laws, rules and regulations of the State of Washington and the City f Federal Way. Owner or agent: Date: FA City -of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: WYNSTONE EAST LOT 94 Address: 1101 SW 339TH ST Permit #: 13 -102482 -00 -SF Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction T Type V - B Occupancy Load Floor Area . ft. 3,484 0 0 0 Owner Name: LENNAR NORTHWEST INC Owner Address: 12815 CANYON RD E SUITE F PUYALLUP WA 98373 Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severly affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner / occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which itis situated. Such compliance is the responsibility of the owner and / or occupant of the premises. THIS CARD IS TO MAIN ON-SITE "T' °�""'""' Construction I ection Record Federal WayINSPECTION REQUE TS: (253) 835-3050 PERMIT #: 13 -102482 -00 -SF . Address: 1101 SW 339TH ST Project: LENNAR NORTHWEST INC FEDERAL WAY, WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 SWM Precon Site Mtg (4400)Initial Erosion Control (42 Approved 0 To be done prior to breaking ground By Date By l_,�,- Date ✓ 0 Foundation Wall (4115) 0 Drainage/Downspout (4040) Final Electrical Approved to place concrete 1:1Approved Approved to backfill By W&8 Date l 30 `14 Maar Date 0 Slab/Concrete Floor (4255) 0 Underfloor Framing (4285) Date Approved to place concrete By Approved to sheath floor By Date By Date 4 21 0 Shear Walls (4245) 0 Roof Sheathing (4220) Approved to install siding Approved to install roofmg By ( Date 1' bof (4 By W Date 4 1z 114 Mechanical Rough -in (4165) Approved t By Date 4 I Li 1 14 Interim Erosion Control (4370) Approved By Date Gas Piping (411, Approved to release test By _ Date _ Prior to scheduling a Framing inspection; I lectrical, Plumbing & Mechanical Rough -in and re/)raft Stop inspections must be signed -off and approved. IBC 109.3.4 Insulation (4150) Gypsum Wallboard Nailing (4130) Approved to install wallboard Approved to install mud & tape By Date 5 (� By Date Final - Mechanical (4065) Final - Plumbing (4075) Approved Approved By Date,—%—/'� By �L,745 Date 55 Footings/Setback (41 Approved to place concrete Date V_ -21z_ t 0 Plumbing Groundwi Approved to cover Date Floor Sheathil Approved to install By " Date —1 (1,1 0 Rough Plumbing (4230) Approved By Date 0 Fire/Draft Stops (4095) Approved By Date Framing (4120) Approved to insulate By h'$ Date �l t,. Final Erosion Control (4375) Approved By Date Final - Building (4050) Approved /`'� By tDate -1 115+4 El Rough Electrical Approved M Final Electrical 1:1Approved Right of Way Approved By Date By Date By Date C,roFPIYAPPLICATION Federal Way JUN 0 7 2013 CITY OF FEDERAL WAY CDS PERMIT NUMBER _ _ S 71d ��LL TARGET DATE SITE ADDRESS SUITE/UNIT # 1101 SW 339st St PROJECT VALUATION ZONING ASSESSOR'S TAR/PARCEL $ 152,790.00 RS7.2 957850 _ 0940 TYPE OF PERMIT ❑ BUILDING ❑ PLUMBINGMEC ICAL 1:1 DEMOLITION ❑ENGINEERING ❑FIRE PREVENTION NAME OF PROJECT Wynstone East Construct new SFR PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER Lennar NW Inc. 253-590-2205 MAILING ADDRESS E-MAIL 12815 Canyon Rd. E., Ste. F karen.hruza@lennar.com CITY STATE ZIP Puyallup WA 98373 NAME PHONE Lennar NW Inc. 253-590-2205 MAILING ADDRESS E-MAIL CONTRACTOR 12815 Canyon Rd. E., Ste. F karen.hruza@lennar.com CITY STATE ZIP FAX Puyallup WA 98373 253-446-6751 WA STATE CONTRACTOR'S LICENSE M EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE M LENNAN1893QG 11/ 07 13 20-13-100182-00-131- 0-13-100182-00-BLNAME NAME PRIMARY PHONE Lennar NW Inc. 253-590-2205 APPLICANT MAILING ADDRESS 12815 Canyon Rd. E., Ste. F E-MAIL karen.hruza@lennar.com CITY STATE ZIP FAX Puyallup WA 98373 253-446-6751 NAME PRIMARY PHONE PROJECT CONTACT Karen Hruza 253-590-2205 MAILING ADDRESS 12815 Canyon Rd. E., Ste. F E-MAIL karen.hruza@lennar.com (The individual to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) Puyallup WA 198373 253-446-6751 PROJECT FINANCING NAME N/A -Owner Financed OWNER -FINANCED Required value of $5,000 or more (RCW 19.27095) MAILING ADDRESS, CITY, STATE, ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance• of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a e s ap ication. SIGNATURE: / DATE S PRINT NAME: Karen Hruza Bulletin #100 — January 1, 2013 Page 1 of 3 k:\Handouts\Pelmit Application I GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF MECHANICAL WORK MECHANICAL PERMIT Lakehaven Lakehaven $ None EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? None $ 4,800.00 Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing res to remain. AIR HANDLING UNITS 6 FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER GARAGE W1 CARPORT ❑ None FIREPLACE INSERTS HOODS (c.—r-1) OTHER (Describe) BOILERS 2 FURNACES HOT WATER TANKS (Gas( �� TOTAL COMPRESSORS 3484 3484 GAS LOG SETS REFRIGERATION SYST 31 DUCTING 3 GAS PIPING WOODSTOVES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF PLUMBING WORK PLUMBING PERMIT Lakehaven Lakehaven $ None EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? None $ 7,900.00 Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing ixtures to remain. BATHTUBS (or Tub/shote: combo( 7 LAVS (Hand sinks( 4 TOILETS WATER PIPING DISHWASHERS GARAGE W1 CARPORT ❑ None RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS 2 SHOWERS VACUUM BREAKERS �� TOTAL DRINKING FOUNTAINS 3484 3484 SINKS (srt�h—/Util<ry( WATER HEATERS (Eka o) 31 2 HOSE BIBBS ESTIMATED SELLING PRICE $ 361,950 # OF BEDROOMS 4 SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS None Lakehaven Lakehaven $ None EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? None 5201 ❑ Yes W No ❑ Yes Gt No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE AREA DESCRIPTION 1167 1167 .. ............ FIRST FLOOR (or Mobile Home) None SI`f? i}e x.! � ' � ".'i : '� • G ,t'� S.,Y.' Sw'.'i ;!' ��e, 7. ........... COVERED ENTRY None 334 334 i IYt I r li . 4,a �.1�." GARAGE W1 CARPORT ❑ None 372 372 �•.ry a`r 3 grIaa Area Totals �� TOTAL 3484 3484 / COMMERCIAL• 1 1 IMPROVEMENTS 777 ESTIMATED SELLING PRICE $ 361,950 # OF BEDROOMS 4 COMMERCIAL11 1 AREA DESCRIPTION Occupancy in S uare Feet qu Type Stories i IYt I r li . 4,a �.1�." �•.ry a`r 3 / COMMERCIAL• 1 1 IMPROVEMENTS • • • , Construction Additional in Square Feet Type tories ..;P K'•• o �.� .Y l(+"�,+"^ti° �r � „�T .t. •t. .J ' i�rSi'� li'�7�•'Ys'._. �S'.•. .�"�'r s�•.� 'jInformation • Y ! ��_}i Yv'w~ #� d.4 yi�� "�. .K; '�[;�. ip,' '..a� 3'':.' '�'i"`` J � � � .:; ."-'7�S ""E r �4»:.��a! rCtr,:' riii 1. TENANT . REA ONLY ,L '.'',.•+," f r' , . k.,y $!'�' .;y Yi•^'' �..--�%.;.��`ay.� ,'4L' T" tr p ( -q rg• i Vii A•T• <«'�}C., jM t } q.. � v �� ?';• '`.LL t'.� ,Y' ','.Lw xe.'.�x y..u,n y rVi''"",_'_��A'R'lI' ':•.ie: t ''t�<._:k._ai':. Bulletin #100 — January 1, 2013 Page 2 of 3 k:\I-Iandouts\Permit Application PROPERTY/LOT LINE A=09'12'20" RIGHT OF WAY LINE R=I 26.00' ROAD CENTERLINE — EDGE OF PAVING/CURB LINE Noizonfol CONTOUR LINE A=1'23'58" STORM DRAIN CATCH BASIN R=1267,50' STORM DRAIN UNE —D - SANITARY SEWER MANHOLE sw 33 SANITARY SEWER LINE SRO - SANITARY SIDE SEWER LINE SS CLEAN OUT (425}251-8782 FAX WATER METER WM WATER MAIN LINE W FIRE HYDRANT FH AIR VACUUM VALVE ASSEMBLY PUYALLUP WA 98327 NATURAL GAS STUB ® G POWER STUB OF CONCRETE o NEW IMPERVIOUS/DRIVEWAY ROOF DOWNSPOUT CONNECTION ------------- RETAINING WALL POINT OF MEASUREMENT 0 SILT FENCE = • LOT SIZE = 5,201 SF LOT COVERAGE: HOUSE PLAN # MAX ALLOWABLE = 60% . TOTAL COVERAGE: 2,070 SF (39.8%) m BUILDING: 1524 SF LOT ADDRESS: DRIVEWAY: 362 SF 1101 SW 339TH ST WALKWAY: 40 SF FEDERAL WAY, WA 98023 PATIO: 144 SF LEGAL DESCRIPTION LOT 94 OF THE PLAT OF BSBL WYNSTONE EAST, RECORDED FRONT: 10' UNDER AUDITOR'S FILE NO. GARAGE: 20' FROM R 20121205001817, RECORDS SIDE: 5' OF KING COUNTY, REAR: 5' WASHINGTON. N38'57'17"E 16.08' F V �Q A=37'44' 18" v R= 81.00' j Im GARAG:C s , 1 L=53.35' +n ' S PNLE 1`l LOT 94 2778 B 1 95 1 x'.48' y EAVE r DS 1 i C DS/ t1 '`336,1`111 �rn PROPOSED CONTOURS 93 A=02'02'00" .fit N01'12'59"E 26.95' M Mi cP R=1359.00' L=48.23' ams A=09'12'20" V H q(j �r R=I 26.00' L=2024' WM FOR Noizonfol LOT 93 A=1'23'58" R=1267,50' v �R L=30.95' <k Q sw 33 LOCATION, CONTRACTOR TO FIELD LOCATE SRO - N01'12'59"E 26.95' M Mi cP R=1359.00' L=48.23' ams S°°`° V H q(j �r 18215 72ND AVENUE SOUTH For; LENNAR NORTHWEST INC. a Noizonfol mQ �+A>j�.�� WA 02 STUB LOCATION 2'x10' PERFORATED PIPE CONNECTION TRENCH PER 2009 KC SWDM FIGURE C.2.11.A APPROX. (KENT, 425)251-8222 LOCATION, CONTRACTOR TO FIELD LOCATE 12815 CANYON RD E, STE F Checked 0 1"=20' S� (425}251-8782 FAX ROOF DOWNSPOUT pyo y 8M5 "e"`°'s .1 g, CIVIL ENGINEERING, LAND PLANNING, RECD � �V/ PUYALLUP WA 98327 pad 5�1 13 N/A �T/A'G ENG�N��4 SURVEYING, ENVIRONMENTAL SERVICES JUN 0 7 2013 1253) 590_2205 `GJJJ SJ IJ LGIJJ File:P:\16000s\16305\lots\16305—Wynstone Lots.dwg Plot Dote/Time:5/31/2013 3:53 PM AJONES T APPROX. POWER VfMTY MAP STUB LOCATION APPROX. GAS STUB LOCATION 2'x10' PERFORATED PIPE CONNECTION TRENCH PER 2009 KC SWDM FIGURE C.2.11.A APPROX. —� LOCATION, CONTRACTOR TO FIELD LOCATE 0 1"=20' S� ROOF DOWNSPOUT CONNECTION RECD � �V/ 'c rn 00 rn A JUN 0 7 2013 C) CD Y OF FEDERAL IMAY CDS HOUSE PLAN # . m T'#fig' RESIDENTIAL SITE PLAN JC S WYNSTONE-LOT 94 PARCEL 957850-0940