Loading...
19-101951 Building - Single Family City of Federal Way Permit #:19-101951-00-SF Community Development Dept 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: OVERFLOW BLESSINGS SENIOR CARE LLC Project Address: 33233 36TH AVE SW Parcel Number: 109961 I270 Project Description: ALT-Verification of Occupancy for Adult Family Home. ***No construction work allowed under this permit.*** Owner Applicant Contractor Lender LYDIAH GATHARA LYDIAH GATHARA 33233 36TH AVE SW 33233 36TH AVE SW FEDERAL WAY WA 98023 FEDERAL WAY WA 98023 USA USA Census Category: 434-Residential alt/add- no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 0.00 0.00 Additional Permit Information New/Additional Sq.Feet-1st Floor 0 New/Additional Sq.Feet-2nd Floor 0 New/Additional Sq.Feet-3rd Floor 0 New/Additional Sq.Feet-Basement 0 Basic Plan? No Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 0 Mechanical to be Included? Yes Number of Stories 4 New/Additional Sq.Feet-Other 0 Plumbing to be Included? Yes New/Additional Sq.Feet-Total 0 Will Certificate of Occupancy be Issued9 No Occupancy#1-Use Residence(1 or 2 Comprehensive Plan Designation SF-High-Density family) Residential • No.Fixt Cres, doted=With Tins Po'rmitlt, "^ E. PERMIT EXPIRES Tuesday,22 October,2019 Permit Issued on Thursday,April 25,2019 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: ,0\k Date: \ 2s °\I t-/4.t City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance,this structure was in compliance with the various ordinances of the City regulating building construction or use.This certificate is valid ONLY when endorsed by City staff. Tenant Name: OVERFLOW BLESSINGS SENIOR CARE LLC Permit# 19-101951-00-SF Address: 33233 36TH AVE SW Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: 0.00 Floor Area(sq.ft.) 0.00 0.00 Owner Name: LYDIAH GATHARA Owner Address: 33233 36TH AVE SW FEDERAL WAY WA 98023 USA Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. • THIS CARD IS TO REMAIN ON-SITE 4.104Construction Inspection Record Way INSPECTION REQUESTS:(253)835-3050 PERMIT#: 19101951 00 Address: 33233 36TH AVE SW Project: LYDIAH GATHARA FEDERAL WAY WA 98023-2903 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. Final-Building(4050) Approved/Date • 0 Rough Electrical Final Electrical 0 Right of Way Approved Approved Approved By Date By Date By Date • Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References:2015 IRC Section R325(WAC 51-51) APPLICATION NUMBER: /f".. / lCCi SOD SECTIONS 1. 2. 3. AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION WILL BE PROCESSED SECTION 1—PROPERTY INFORMATION SITE ADDRESS 33a33 3b��p(Vs wory ASSESSORS TAXIPARCEL#: Ct(Q_ t 2-73-0 SECTION 2—APPLICANT INFORMATION PROPERTY OWNER NAME: p GN- €t 1'r 11411\ t_.P — DAYTIME PHONE: i-0 b - O\ uqt c( AFH LICENSEE NAME(IF DIFFERBIT): -D�&C V ' cc DAYTIME PHONE: 1 I SECTION 3—FLOOR PLAN On a separate sheet of paper (8 1/2 x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms (bedrooms) indicating which bedroom is: A, B, C D, E and F. Label all components for exiting i.e.,stairs, ramps, platforms, lifts and elevators. SECTION 4—DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home at this location. I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any person,including the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application. I a NAME/TITLE: ,-_W)\ >_ � _ Mt ��14 ` DATE: j„�,I'}-3, �1 Y L$PROPERTY OWNER QAPPLICANT Q LICENSEE ` lJ (Effective July 1, 2013.) Effective:2013 July 01 Updated:2017 February WAC 51-51-0325 Section R325—Adult family homes. SECTION R325 ADULT FAMILY HOMES R325.1 General.This section shall apply to all newly constructed adult family homes and all existing single family homes being converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington department of social and health services prior to July 1,2001. R325.2 Reserved. R325.3 Sleeping room classification.Each sleeping room in an adult family home shall be classified as: 1.Type S-Where the means of egress contains stairs,elevators or platform lifts. 2.Type NS1 -Where one means of egress is at grade level or a ramp constructed in accordance with R325.9 is provided. 3.Type NS2 -Where two means of egress are at grade level or ramps constructed in accordance with R325.9 are provided. R325.4 Types of locking devices and door activation. All bedroom and bathroom doors shall be openable from the outside w hen locked. Every closet shall be readily openable from the inside. Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist.Pocket doors shall have graspable hardw are available w hen in the closed or open position. The force required to activate operable parts shall be 5.0 pounds (22.2 N) maximum. Required exit doors shall have no additional locking devices. Required exit door hardw are shall unlock inside and outside mechanisms w hen exiting the building allowing reentry into the adult family home without the use of a key, tool or special know ledge. R325.5 Smoke and carbon monoxide alarm requirements.All adult family homes shall be equipped with smoke and carbon monoxide alarms installed as required in Sections R314 and R315.1. Alarms shall be installed in such a manner so that the detection device warning is audible from all areas of the dwelling upon activation of a single alarm. R325.6 Escape windows and doors.Every sleeping room shall be provided with emergency escape and rescue windows as required by Section R310. No alternatives to the sill height such as steps,raised platforms or other devices placed by the openings w ill be approved as meeting this requirement. R325.7 Fire apparatus access roads and water supplyfor fire protect ion.Adultfamily homes shall be served by fire apparatus access roads and water supplies meeting the requirements of the local jurisdiction. R325.8 Grab bar general requirements.Where facilities are designated for use by adult family home clients, grab bars for water closets,bathtubs and shower stalls shall be installed according to this section. R325.8.1 Grab bar cross section.Grab bars with a circular cross section shall have an outside diameter of 1 1/4 inches minimum and 2 inches maximum. Grab bars with noncircular cross section shall have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4 5/8 inches maximum. R325.8.2 Grab bar installation.Grab bars shall have a spacing of 1 1/2 inches between the wall and the bar.Projecting objects, control valves and bathtub or show er stall enclosure features above, below and at the ends of the grab bar shall have a clear space of 1 1/2 inches to the grab bar. EXCEPTION:Swing-up grab bars shall not be required to meet the 1 1/2 inch spacing requirement Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener,mounting device or supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering unit. Acrylic bars found in bathing units shall be removed. Fixed position grab bars,when mounted, shall not rotate, spin or move and have a graspable surface finish. R325.8.3 Grab bars at water closets.Water closets shall have grab bars mounted on both sides. Grab bars can be a combination of fixed position and swing-up bars.Grab bars shall meet the requirements of R325.8. Grab bars shall mount between 33 inches and 36 inches above floor grade. Centerline distance between grab bars,regardless of type used, shall be between 25 inches Effective:2013 July 01 Updated:2017 February minimum and 30 inches maximum. R325.8.3.1 Fixed position grab bars.Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from the rear w all. R325.8.3.2 Swing-up grab bars.Swing-up grab bars shall be a minimum of 28 inches in length from the rear w all. 8325.8.4 Grab bars at bathtubs.Horizontal and vertical grab bars shall meet the requirements of R325.8. R325.8.4.1 Vertical grab bars.Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and head end wall.Grab bars shall mount within 4 inches of the exterior of the bath tub edge or w ithin 4 inches within the bath tub. The bottom end of the bar shall start betw een 36 inches and 42 inches above floor grade. EXCEPTION:The required vertical grab bar can be substituted with a floorto ceiling grab bar meeting the requirements of R325.8 at the control end and head end entry points. R325.8.4.2 Horizontal grab bars.Horizontal grab bars shall be provided at the control end, head end, and the back w all w ithin the bathtub area.Grab bars shall be mounted betw een 33 inches and 36 inches above floor grade. Control end and head end grab bars shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. R325.8.5 Grab bars at shower stalls.Where shower stalls are provided to meet the requirements for bathing facilities, grab bars shall meet the requirements of R325.8. EXCEPTION:Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab bars at the seat end wall.A vertical floor to ceiling grab bar shall be installed within 4 inches of the exterior of the shower aligned with the nose of the built-in seat. R325.8.5.1 Vertical grab bars.Vertical grab bars shall be 18 inches minimum in length and installed at the control end w all and head end w all.Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. R325.8.5.2 Horizontal grab bars.Horizontal grab bars shall be installed on all sides of the shower stall mounted betty een 33 inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls.Horizontal grab bars shall not interfere with shower control valves. R325.9 Ramps.All interior and exterior ramps, w hen provided, shall be constructed in accordance with Section R311.8 with a maximum slope of 1 vertical to 12 horizontal. The exception to R311.8.1 is not allowed for adult family homes. Handrails shall be installed in accordance with R325.9.1. R325.9.1 Handrails for ramps.Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with R311.8.3.1 through R311.8.3.3. R325.10 Stair treads and risers.Stair treads and risers shall be constructed in accordance with R311.7.5. Handrails shall be installed in accordance with R325.10.1. R325.10.1 Handrails for treads and risers.Handrails shall be installed on both sides of treads and risers numbering from one riser to multiple risers. Handrails shall be installed in accordance with R311.7.8.1 through R311.7.8.4 R325.11 Shower stalls.Where provided to meet the requirements for bathing facilities, the minimum size of shower stalls for an adult family home shall be 30 inches deep by 48 inches long. [Statutory Authority:RCW 19.27.031 and chapters 19.27 and 34.05 RCW.13-04-068,§51-51-0325,filed 2/1/13,effective 7/1/13.Statutory Authority:Chapter 19.27 RCW.10-18-036,§51-51-0325,filed 8/25/10,effective 9/25/10.Statutory Authority:RCW 19.27.190,19.27.020,and chapters 19.27 and 34.05 RCW.09-04-023,§51-51-0325,filed 1/27/09,effective 7/1/10.Statutory Authority:RCW 19.27.074,19.27.020,and chapters 19.27 and 34.05 RCW.07-01-090,§51-51-0325,filed 12/19/06,effective 7/1/07.StatutoryAuthonty:RCW 19.27.031 and 19.27.074.04- 01-109,§51-51-0325,filed 12/17/03,effective 7/1/04.] Effective:2013 July 01 Updated:2017 February NAME OF AFH: el -- .0\ OIL"ejkl SECTION 5 MUSTBE COMPLETED BY THE BUILDING DEPARTMENT INTHEJURISDICTIONTHE HOME WILL BE LOCATED. PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A B CD E AND F AND CLASSIFICATION CODES,NS1 OR NS2. SECTION 5—BUILDING INSPECTOR'S INSPECTION CHECKLIST R325.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area Type NS1—where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R325 9 is provided to evacuate residents to public area. Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with R325.9 are provided to evacuate residents to public area. • . SLEEPING ROOM.A , 0 Type S O Type NS1 tom'Type NS2 YES NO Closetdoor/s are readily openable from the inside gYes 0No Smoke al arm is installed in the bedroom � 0 Bedroom door opens easily and quickly from the outs ide when locked ® 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;atl east 20"wide) A 0 EXCEPT per R310.2.1:at-gradeescapewi ndows—may have netclearance opening 5 SF Sleeping room window has a maximum sill height of 44"abovefloor to clear opening;no steps under window allowec la 0 SLEEPING ROOM B 0 Type S 0 Type NS1 El Type NS2 YES NO Closetdoor/s are readily openablefromthe inside LEI Yes 13 No Smoke al arm is installed in the bedroom0 Bedroom door opens easily and quicklyfrom the outs ide when locked ja 0 Sleeping room window has a net opening of5.7SF(minimum dimensions at least 24"high;atl east 20"wide) $ 0 EXCEPT per R310.2.1:at-grade escape windows—ma y have netclearance opening 5 SF Sleeping room window has a maximum sill height of 44"a bove floor to clear opening;no steps under windowallowec JEI 0 SLEEPING ROOM C 0 Type S O Type NS1 1j4 Type NS2 YES NO Closetdoor/s are readily openable from the i nside ItYes 1:1 No Smoke alarm is installed in the bedroom Al 0 Bedroom door opens easily and quickly from the outside when locked ..' 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions atleast 24"high;at least 20"wide) Al 0 EXCEPT per R310.2.1:at-grade escape windows—may have netclearance opening 5 SF Sleeping room window has a maximum sill height of 44"abovefloor to clear opening;no steps under windowallowec 111 0 SLEEPING ROOM D O Type S 0 Type NS1 Al Type NS2 YES NO Closetdoor/s are readily openable from the i nside gYes 10 No Smoke al arm is installed in the bedroom .® 0 Bedroom door opens easily and quicklyfromthe outside when locked El 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions atleast 24"high;atleast 20"wide) 0 EXCEPT per R310.2.1:at-grade escape windows—may have netclearance opening 5 SF Sleeping room window has a maximum sill height of 44"a bovefloor to clear opening;no steps under windowallowec 0 'SLEEPING ROOM E 0 Type S 0 Type NS1 gt Type NS2 YES NO Closet door's are readily openable from the i nside j,Yes 0 No Smoke a la rm is installed in the bedroom .- 0 Bedroom door opens easily and quicklyfrom the outs ide when locked .Q' 0 Sleeping room window has a net opening of5.7SF(mi nimumdimensions atleast 24"high;atleast 20"wide) CL. 0 EXCEPT per R310.2.1:at-grade escape windows—may have netclearance opening 5 SF Sleeping room window has a maximum sill height of 44"a bove floor to clear opening;no steps under windowallowec 0 0 SLEEPING ROOM F O Type S 0 Type NS1 O Type NS2 YES NO Closetdoor/s are readily openable from the i nside 0 Yes El_No I Smckealarmisinstalledinthebedroom 0 0 Bedroom door opens easily and quicklyfromth- • -'.- en locked 0 0 Sleeping room window has aneto.-•• :o 5.7 SF(mi nimumplirr n ' satleast 24"high;atleast 20"wide) 0 0 EXCEPT per R310.2.1:at-gr.• -scape wi ndows—may haveLtr eopening 5SF Sleeping room wind• has a maximum sill height of 44"abo floor to clear opening;no steps under windowallowec 0 0 Effective:2013 July 01 Updated:2017 February GENERAL . YES NO ' Bathroom doors are easily and quickly openable from the outs ide when locked , . 0 Carbon Monoxide alarms a re installed asrequired inR315oneachlevelofthe home. 0 Smoke a la rms are i nstalled on all levels of the dwelling,in each resident sleeping room,outside ea ch separate sleeping area in the i mmediate vicinity of sleeping rooms(R314). 0 Smoke and Carbon Monoxide alarms areinstalledinsuchamannersothattheaudiblewarningmaybeheardinall AI 0 parts of the dwelling upon activation of a single device. Access road and water supply meet localfirejurisdictional requirements. 0 R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 1 0 Pocket doors shall have graspable hardware available when in the closed or open position. 0 R311,:8 Ramps ', ,, ,' ' .. . , - k . . f YES NO Inside Ramp, ' N/A ' ;,. ... . , . ,' . ,, ,,,„ 0 0 R311.8.1 Maximum 5 lope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 0 R311.8.2 Landing Requirements:min.3X3 foot landing attop/bottom,where doors open onto ramps,and where rampchanges directions. 0 0 R325.9.1 Handrails required on both sides of ramp in accordance with R311 8.3.1–R311.8.3.3. 0 0 Outside Ramp N/Ag YES NO R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope) (Exception R311.8.1 Not allowed in AFH) ,13 0 R311.8.2 Landing Requirements:min.3X3 foot landing attop/bottom,where doors open onto ramps,and where rampchanges 0 directions. R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1–R311.8.3.3. 0 0 Guards bel ow a re depi cted vertically as an example only.All Ramps must have Guards , 0 r- Handrail both sides Less than 4" i 34"-38" i Guard `� -- _— 36"min --` - I j 1 s✓ _� 3'x3'min �_ landing 3'x 3'min ------ _ .............� landing N �y _� - , _, i 3' { One unit vertical in twelve units horizontal 3' minimum is an 8.3%slope all along surface of the ramp. minimum R311.2 Means of Egress . . YES NO R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. 0 0 R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). ® 0 R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry a 0 without use of key,tool or ecial knowledge. „R311.7Stairways I'N/A � YES NO R311.7.5.1 Riser Height:Max riser height shall be 7%inches(8 inches in structures built prior toJuly 1,2004) 0 0 R311.7.5.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) 0 0 R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple 0 0 risers.Handrails shall be installed in accordance with R311.7.8.1–R311.7.8.4 Effective:2013 July 01 Updated:2017 February R325.8 Grab Bars in Bathrooms I N/A 0 YES NO Grab bars shall be installed for all water closets(toilets),bathtubs and showers according to R325.8. i 0 Water Closets(toilet)shall have grab bars installed on both sides according to R325.8—R325.8.3.1 or R325.8.3 2. 0 Bathtubs shall have two vertical and three horizontal grab bars installed according to R325.8-R325.8.4—R325.8.4.2 0 Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R325.8—R325.8.5— A 0 R325.8.5.2. Shower stalls must be minimum size of30 inches deep by48 inches long(R325.11) i' 0 AG103—AG105 Swimming Pool,Spa, Hot Tub YES NO AF105.2 Must be surrounded bya barrier that is 48 inches high, h Ars and or gates that must have audible alarms when 0 0 opened. AG105.5 EXCEPTION: Pools,Spas or Hot Tubs with a safety coverw ch complies with ASTM F 1346 0 0 9(�PASSED '0eORRECTIONSREQUIRED Q PERMIT.REQUIRED„ , ` INSPECTORNAM 'S ' PRINT)` . ' . ' INSP S SIGN " ' D E: 3332S-.5 . /4v.if. 1 - . . " . .2 - As= INSPECTOR'S OFFICEADDRESS PHONE NUMBER:' Application and inspection checklist developed by Washington Association of Building Officials(WABO),in cooperation with Department of Social and Health Services(DSHS)for use by both departments'and licensors. 07/01/2013 Effective:2013 July 01 Updated:2017 February --'-'i\--1- 1/4-7-- c 3- 1.c.,\--A ---1- . • 1 . • . , ' P.6 r9• 1 i .5'•b7.;:. A. 42 •ris---- ---• --- ..., = . i I (/‘1 I iq\li g.M 1 HT— ! 1 , I 1-•-•, ii i 1 .._ I ----7-1 - C 11 -Cs'N ;• , / li ii i, 1 2,_I, • t ' J fi , ) ,.0., . _ 1 t i Li.— if"---------i. ... .t - ) AA HI / .••••-• I , : 1 'I' --;,... •-.1--s1 , 311/101-ic r d ,.! •I. .A.A.. - _± ,, --K - -t 1 --- ' , \ 1 . t',1-..- 1 1 •Nt •4 1 1746 )(0 °II ' I31A 6,e'i.xc. ,01 -..i 9 lAIY 11 c.i.FE r. 1 •i 11 •,i 1 i 1 I --4 - - T-----_____,.-,.. — 4.4 -Tivl - - „