11-101759 City of Federal Way Etrectrcal• Community Development Services Permit #: 11-101759-00-EL P.O.Box 9718 Federal Way,WA 98063-9718 Ph:(253)835-2607 Fax (253)835-2609 Inspection Request Line: (253)835-3050 F I LE Project Name: AREVA Project Address: 505 S 336TH ST Suite 400 Parcel Number: 926480 0270 Project Description: Install low voltage voice and data cabling Owner Applicant Contractor FSP FEDERAL WAY CORP B&C TELEPHONE INC BLACK BOX NETWORK SERVICES 401 EDGEWATER PL SUITE 200 800 SE 34TH ST SUITE A (DESIGN NET) WAKFIELD MA 01880-6207 RENTON WA 98055 BCTELI*001L1 (6/21/12) 800 SW 34TH ST SUITE A xx RENTON WA 98057 r Is Use Educational or Institutional? No Service greater than 999 Amps? No {. t., '4t;.; XI .. � ,,.kw. �'v''F±•'.. `.T `` �.;.z. v•°Yews . css Fixtures ffiii'i, ;...00'•".•": ;K', i . , ..1r�„.”' . , S .; am � ' Low Voltage-Other(Commercial; I PERMIT EXPIRES Saturday, May 5, 2012 Permit Issued on Friday, May 6, 2011 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: _ � Date: 5 " (�- 1 ( Fit 6fr ill -ter. • THIS CARD IS T MAIN ON-SITE '` ' ' crr c Construction I ection Record Federal Way INSPECTION REQUE TS: (253)835-3050 PERMIT#: 11-101759-00-EL Address: 505 S 336TH ST Suite 400 Project: FSP FEDERAL WAY CORP FEDERAL WAY, WA 98003 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. El UFER Ground (4295) El Ditch cover(4030) ❑ Slab/Concrete Floor(4255) Approved Approved Approved to place concrete By Date By Date By Date El Pool Bonding(4195) 0 Temporary Power(4275) CI Service(4235) Approved Approved Approved By Date By Date By Date 0 Feeders/Sub-panels(4045) '0 Rough Electrical(4225) �El Ceiling Cover(4020) Approved Approved Approved By Date By Date By(� Date 1 v- l ( . ❑ Fi I-Electrical(4055) Approved By Date 17 ❑ Rough ElectricalEl Final Electrical El Right of Way Approved Approved Approved By Date By Date By Date t • f i _E.L..,-,(.2( 7 5-61 CITY of ..w' _ _R , vE Federal Way ELECTRICAL PERMIT APPLICATION MAY 0 6 VII CITY OF FEDEIIAL WAY **Most electrical permits may be obtained on-line at www.cityo ederalwa . * SITE ADDRESS: 5°5 S 3�(0-11‘. 5-1- T- tteAk wcvy VA_ CI Soc2 SUITE/UNIT/SPACE# ASSESSOR'S TAX/PARCEL# CURRENT/PROPOSED USE L11N �1oor qz- & c _ © Zq- D PROJECT NAME (Tenant or Homeowner Last Name) P re/CL Lour Voktc4 e Vo. 4, "tc.A.k 6kl ttA PROJECT DESCRIPTION Detnilpd description of work to be included on this permit only NAMEPRIMARY PHONE PROPERTY OWNER �L----c-- !A ,-, ,-- t1.-1-- ( ) MAILING ADDRESS ADDRESS E-MAIL • CITY STATE ZIP FAX ( ) • NAME PRIMARY PHONE 0(r6‘CI,ac 16©c Ne;kwnrk SeiV(A45 (aDb )'163 -�qq� MAILING ADDRESS E-MAIL , ELECTRICAL )CO SW 34 th A CONTRACTOR CITY STATEFAX ReA 61B06-1 B05, ( )tn�i,n WA STATE CONTRACTOR'S LICENSE N EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# ISCrtMa4k oo 1,1..I 6 ),1 i Ia aD-oa-locol15•-Oo-Zeis NAME PRIMARY PHONE APPLICANT rEk C-le_Ne.g p, (660 ) 46-1 - 2110 MAILING ADDRESS E-MAIL 65 E L-.t.,t;,o\,n c .cL * Io\ . CITY STATE ZIP FAX SpOkuYne, "A- CI°laoe) (Soil ) `bbl - 2268 NAME PRIMARY PHONE PROJECT CONTACT - —' 123 't4! ;e (4;5 ) a° l - 131 I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses, and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE: G .-i�� DATE 5+ 6-‘k PRINT N a.sme S A j rCw 5 cze.,I N' 33325 8th Avenue South•PO Box 9718•Federal Way•WA•98063-9718•253-835-2607•fax:253-835-2609♦www.cityoffederalway.com Bulletin#160-April 9,2010 Page 1 of 2 k:\Handouts\Electrical Permit Application • RESIDENT COMMERCIAL NEW SINGLE FAMILY RESIDENCE NEW COMMERCIAL Total Square Feet (including attached garage): 1st Service/Feeder Additional Feeders •0-- 100 amp .x:$132.50 x$ 80.50 FEES: First 1300 ft2-$122.00; 101- 200 amp x$164.00 x$103.50 Each additional 500 ft2-$39.00 201- 400 amp x$307.00 x$121.00 NEW MULTIFAMILY (3 units or more) 401 - 600 amp x$358.00 x$143.50 1st Service/Feeder Additional Feeders 601- 800 amp x$463.00 x$196.00 0- 200 amp- x-$132.80• x .°$ 39.0.0 801- 1000 amp x$565.00 x$236.50 201 -400 amp x $164.00 x $ 80.50 Over -1t3Ci0 aXig;-_'->.' , .<`x$616.00 x$326.50 601 -800 amp x $287.00 x $153.50 Over 600 volts surcharge x$103.50 Over 800 amp x $410.50 x •t$307.00 ALTERED SINGLE or MULTI FAMILY ALTERED COMMERCIAL 1st Service/Feeder 1st Service/Feeder Additional Feeders 0= 206:amp ac01:Oi2 0 200 amp •r x$132.50 x$103.50 201 -600 amp x $164.00 201- 600 amp x$307.00 x$121.00 Over 600 amp x4246.50 601-100.0 altp x$463.00 x$196.00 Over 1000 amp x$515.50 x$328.50 Added or Altered Circuits 1-4 circuits$80.50:each additional$8.00 Added or Altered Circuits 1-5 circuits$103.50: each additional$8.00 Mast or meter repair $60.50 Mast or meter repair $111.50 MANUFACTURED HOMES PLAN REVIEW FEES Service or feeder only x $ 80.50 Plan Review required only for: Service and feeder x •$182.50 • New,or alteration to, service of 1.000 amps or greater • Medical/Educational/Institutional Facility $103.50 plus 35%of Permit Fee (Permit Fee x 35%= +$103.50=Plan Review Fee) Plan review for modified submittals $105.50/hour MISCELLANEOUS SERVICE/EQUIPMENT LOW VOLTAGE TEMPORARY SERVICE ❑ Fire Alarm System 1 g Service/Feeder Additional Feeders ❑ Security Alarm System 311 Voice/Data Cabling 0-- 60 amp x $ 71.00 x $ 32.00 ❑ Other61 - 100 amp x $ 80.50 x $ 39.00 Area to be served by system: 5000 1•e 2,500 ft2-$71.00:each additional 2,500 ft2-$18.50 1{11' 100 amp, ' $103.50 x $ 51.00 201-400 amp •X $121.00 x $ 60.50 #of Thermostats 401--600 amp ;x'$164.00 x $ 80.50 First$60.50;each additional$18.50 Over 600 amp $184.50 x $ 92.00 #of Signs FEE CALCULATIONS First$60.50:each additional$28.50 • Fees are determined by the scope of work as indicated. Yard Pole/meter loops/pedestal x$ 80.50 • A$6.00 Automation Fee will be added to all permits. • For assistance in calculating fees or completing the Portable Generator(transfer equipment) x$101.00 application form,contact the Permit Center at Ditch cover/inspection only x$121.00 253-835-2607 33325 8th Avenue South•PO Box 9718•Federal Way♦WA♦98063-9718•253-835-2607♦fax:253-835-2609♦www.cityoffederalway.com Bulletin#160-April 9,2010 Page 2 of 2 k:\l-Iandouts\Electrical Permit Application