Loading...
13-102458 ? e • • .. 4. r ilding —Single Family • City of Federal Way ", .//� �/ Community&Econ.Dev.Services '? k Permit tt. 1 3-���t �VQ -��-�' 333258th Ave S Federal Way,WA 98003 a FL ` Ph:(253)835-2607 Fax (253)835-2609 Inspection Request Line: (253)835-3050 Project Name: WYNSTONE EAST LOT 34 Project Address: 813 SW 341ST ST Parcel Number: 957850 0340 Project Description: NEW-Construction of a 2,778 square foot 2-story single family residence with basement, 334 square foot covered entry and 372 square foot attached garage. Includes plumbing& mechanical. **4 Bedrooms; $361,950 estimated selling price** Owner Applicant Contractor Lender LENNAR NORTHWEST INC LENNAR NORTHWEST INC LENNAR NORTHWEST INC OWNER IS LENDER 12815 CANYON RD E SUITE F 12815 CANYON RD E SUITE F LENNANI893QG (11/7/13) PUYALLUP WA 98373 PUYALLUP WA 98373 12815 CANYON RD E SUITE F PUYALLUP WA 98373 Census Category: 101 -New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load 0 0 0 Floor Area(sq.ft.) 3,484 tF� Additional Permit Information New/Additional Sq.Feet-1st Floor 1167 New/Additional Sq.Feet-2nd Floor 1093 New/Additional Sq.Feet-3rd Floor 0 Occupancy#1 -Area(Sq.Feet) 3484 New/Additional Sq.Feet-Basement 518 Basic Plan? No Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 372 Mechanical to be Included? Yes Plumbing Work Valuation? 7900 Occupancy#1 -Class R-3 New/Additional Sq.Feet-Other 334 Plumbing to be Included') Yes New/Additional Sq.Feet-Total 3484 Occupancy#1-Use Residence(1 or 2 family) Zoning Designation. RM 3600 Mechanical Fixtures Ducting 1 Fans 6 Fireplace Inserts 1 Furnaces 1 Gas Piping 1 Gas Pipe Outlets 3 Hot Water Tanks 1 Plumbing Fixtures Bathtubs 1 Dishwashers 1 Laundry Washer Outlets. 1 Lavatories 7 Showers 2 Sinks 1 Water Closets 4 Hose Bibbs 2 PERMIT EXPIRES Monday, March 31, 2014NALEn Permit Issued on Wednesday, October 2, 2013 �' I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. J Owner or agent � \ Date: �O/Z I- -- „. i 4- 2-3 ( . cam, T_ssu �� c1.9 orf f- • • 'City of F.ideral Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: WYNSTONE EAST LOT 34 Permit#: 13-102458-00-SF Address: 813 SW 341ST ST Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 3,484 0 0 0 Owner Name: LENNAR NORTHWEST INC Owner Address: 12815 CANYON RD E SUITE F PUYALLUP WA 98373 Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severly affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. ,' - THIS CARD IS TO viVIAIN ON-SI'ZE CITY OF } • Construction In action Record Federal Way INSPECTION REQUE TS: (253)835-3050 PERMIT#: 13-102458-00-SF Address: 813 SW 341ST ST Project: LENNAR NORTHWEST INC FEDERAL WAY, WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your. inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. SWM Precon Site Mtg(4400) Initial Erosion Control(4365) Footings/Setback(4110) Approved To be done prior to breaking ground Approved to place concrete By Date By Date Date (6) ( ((' Foundation Wall(4115) 0 Drainage/Downspout(4040) El Plumbing Groundwork(4190) Approved to place concrete Approved to backfill Approved to cover By k I, Date (,o (3l 113 By Date ///(//3 By 0 Az.-- Date t—t -13 ▪ Slab/Concrete Floor(4255) Underfloor Framing(4285) Floor Sheathing(4105) Approved to place concrete Approved to sheath floor Approved to install flooring B ✓ Date( / 0:)//i, By Date By 55 Date 7__/ z' Shear Walls( 245) 0 Roof Sheathing(4220) 0 Rough Plumbing(4230) Approved to install siding Approved to install roofing //�� Approved By (� Date it By ktg Date laic I I? By 0 �r� ' Datet ▪ Mechanical Rough-in(4165) 'El Gas Piping(4125) Fire/Draft Stops(4095) Approved Approved to release test Approved By 5) Date/...- By( Date® , I By Date i • EI Interim Erosion Control(4370) Prior to scheduling a Framing inspection; El Framing(4120) Approved Approved to insulate Electrical,Plumbing&Mechanical Rough-in and Fire/Draft Stop inspections must be signed off and By Date approved. IBC 109.3.4 By (-N. l �, 1 — ))L1lJ,l� . Insulation(4150) Gypsum Wallboard Nailing(4130) 0 Final Erosion Control(4375) A roved to install wallboard Approved to install mud&tape Approved • Date '1- By ; Date — By Date Final-Mechanical(4065) El Final-Plumbing(4075) El Final-Building(4050) Approved Approved Approved .B Date 4_\v.--\ By j Date L l�. ( By C Date / -/Z Rough Electrical Final Electrical El Right of Way Approved Approved Approved By Date Date iiL'�c/ By Date *RECEIVE® Cr• ofA. PERMI'1DAPPLICATION Federal Way JUN 0 4 2013 fin1 CITY OF FEDERAL WAY tij PERMIT NUMBER / / 0 a ��D R' _ 5 TARGET DATE7p37/3 SITE ADDRESS SUITE/UNIT# 813 SW 341st St PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ 152,790.00 RS7.2 957850 _ 0340 TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Wynstone East bbl , L Construct new SFR PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER Lennar NW Inc. 253-590-2205 MAILING ADDRESS E-MAIL 12815 Canyon Rd.E.,Ste. F karen.hruza@lennar.com CITY STATE ZIP Puyallup WA 98373 NAME PHONE Lennar NW Inc. 253-590-2205 MAILING ADDRESS E-MAIL CONTRACTOR 12815 Canyon Rd.E.,Ste. F karen.hruza@lennar.com CITY STATE ZIP FAX Puyallup WA 98373 253-446-6751 WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# LENNANI893QG 11/ 07 13 20-13-100182-00-BL NAME PRIMARY PHONE Lennar NW Inc. 253-590-2205 APPLICANT MAILING ADDRESS E-MAIL 12815 Canyon Rd.E.,Ste. F karen.hruza@lennar.com CITY STATE ZIP FAX Puyallup WA 98373 253-446-6751 NAME PRIMARY PHONE PROJECT CONTACT Karen Hruza 253-590-2205 (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence 12815 Canyon Rd. E., Ste. F karen.hruza@lennar.com concerning this application) CITY STATE ZIP FAX Puyallup WA 98373 253-446-6751 NAME PROJECT FINANCING N/A-Owner Financed 0 OWNER-FINANCED Required value of$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs, expenses, and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the ci SIGNATURE: DATE PRINT NAME: Karen Hruza Bulletin#100—January 1,2013 Page 1 of 3 k:\Handouts\Permit Application i • L 1 VALUE OF MECHANICAL WORK MECHANICAL PERMIT $4,800.00 • Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. AIR HANDLING UNITS 6 FANS GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER I FIREPLACE INSERTS HOODS(commercial) BOILERS 1 FURNACES HOT WATER TANKS(Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING 3 GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT $7,900.00 Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. BATHTUBS(or Tub/Shower combo) 7 LAVS(Hand Sinks) 4 TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS 2 SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS 1 SINKS(Kitchen/utility) WATER HEATERS(Electric) 2 HOSE BIBBS SUMPS 1 WASHING MACHINES 31 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS None Lakehaven Lakehaven None EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? ❑Yes d No ❑Yes R' No None 5236 RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE i FIRST FLOOR(or Mobile Home) None 1167 1167 1 ................................................................................................ COVERED ENTRY None 334 334 -4,4ffrazt: 10,C ................................................................................................................................................................................................ GARAGE C✓J CARPORT ❑ None 372 372 yr`- mu EXISTIRO PROPOSED TOTAL Area Totals - 3484 3484 ESTIMATED SELLING PRICE$ 361,950 # OF BEDROOMS 4 COMMERCIAL—NEW/ADDITION AREA DESCRIPTION Area Occupancy Group(s) Construction #of Additional Information in Square Fee-11 Jt Stories ADDITION COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area Occupancy Group(s) Construction #of Additional Information in S.uare Feeta Stories .u Ar TENANT AREA ONLY j (1i l , 'a , 11 Bulletin#100—January 1,2013 Page 2 of 3 k:\Handouts\Permit Application ` Web d r ' 4 . 007 ♦ :Ai ', i d d i 2 - 4 , l , 7i i d 1 { g Department of Development and Environmental Services ,1 __,-,-- ; , ., , ' J Building Services Division ___..___ w..... '....�_..__:..,__.,_� .._ x .. _, El u 900 Oakesdale Avenue Southwest Renton,Washington 98057..5212 1EFor alternate formats, call 206-296-6600.x_NE • 206-2966600 TTY 206-2967217 This certificate provides the Public Hea - ing County Department and the Department of Development and Environmental Services with information necessary to evaluate de •w •z ,.,1,'osals,r Do not write in this box RE ., # 4 Number Name UN 0 4 2913 I .Fir Building Permit Ea-Preliminary Plat or PUD 0 Short Subdivision 0 Rezone or other: CITY OF FEDERAL WAY J L .�.#1Applicant's name: t � -} y I Proposed use: •h, „i. A,. t — , 6 lip' _16_. =. V Location(attach map and legal description if necessary): pt.pp top(t 4....'9<')t t '4' "r 6i' I” R a 9 ab St.A3 C. tx S MIQC r Water purveyor information: +f 1. 0 a. Wates can be provided by service connection only to an existing (size)water main that is 0 4R feet from the site. .'4 id b. Water service will require an improvement to the water system of: (1 W 410. 0 feet of water main to reach the site;and/or 11(2) The construction of a distribution system on the site;and/or MU gT St&Ca MEP g iy 6(3) Other(describe): co KO MT oewLopEK E 14N 1441-ketl .». c +'t ,/ 2. iii a. The water system Is In conformance with a County.approved water comprehensive plan; OR P t{V 1L51w, 0 b. The water system Improvement is not in conformance with a County approved water comprehensive plan and will require a water comprehensive plan amendment. (This may cause a delay in issuance of a permit or approval.) r✓ 3. 4 a. The proposed project is within the corporate limits of the district,or has been granted Boundary Review Board approval for extension of service outside the district or city,or is within the County approved service area of a private water purveyor. OR ❑ b. Annexation or Boundary Review Board(BRB)approval will be necessary to provide service. f 4. MO a. Water is or will be available at the rat of flow and duration indicated below at no less than 20 psi measured at the nearest fire hydrant :i/..•5-m 't"/ 346 feet from the building/property(or as marked on the attached map): Rate of Row at Peak Demand: ❑less than 500 gpm(approx, gpm) 0 500 to 999 gpm 0 1000 gpm or more 0-flow test of gpm L]calculation of gpm Duration, 0 lass than 1 hour Li 1 hour to 2 hours 114 2 hours or more Other S e 411'*kc*I. P (Note: Commercial building permits which include multifamily structures require flow test or calculation.) OR 0 b. Water system is not capable of providing fire flow. 5; ® a. ` Water system has certificates of water rights or water right claims sufficient to provide service. OR ❑ b. Water system does not currently have necessary water rights or water right claims.. V Comments/conditions: WM (2 Srsit.441.CIE CONNeC ia,r,„i 4PfUC 15 (4411 ite I certify that the above water purveyor information is true. This certification shall be Valid for one year from date of signature. Tf„ LAKEHAVEN UTILITY DISTRICT 8/“... 0 ei-S+6 P..1 ` Agency name Signatory.na e F-14 6. TE,c.fi, Tr - 7/13/i--2-- TitleSign litrik i7//1/2. Date • ./ 4/. Pressure Zone; Highest �a, xc In 45-'11t Lowest Elevation of Property �O+� 29-a- ;Est. Max. Pressure psi The District, at its sole discretion, reserves the right to delay or deny water service based upon capacity limitations in District and Other Purveyor facilities. Water availability form Rev.06-19-2003 Page 1 of 1 , , 11II Page 2 of 2 . , ... . ea lb . tio. a -.4- 1- . 'II — ccw 8 - t , co 8 III .., p i , 0 "c/‘'/'.-•14.",.1...-..iv'A1l0I0j1IeiIIi11iiP tk ii'agiit _''., , ..,,,,. ./ . 1-:-• 8 ( 1",$... -_.2 i- .,ij.. .,..-..., Nri-.-;3''•''''' ..-, „1•.I°A. 0.._10t _ . H .,--f_l'..,„„_. 4,.ra 2,7-•-:-.11.-',7-,-- - " ' •or.,.., {i%\\ 11 Ad. .-. 9 dr dr ....i, e 1.3 e . 'II '8 0.ez_____,._._ . ,..-..--- . L;:d• .4*' ydrarits: +1-5 cr -360 c,... .., , ater mai n: +/-15 1,4 ..., ---------*17- ...- i ---.,, INIMicaliiiii 11111111111r.1111M , ill•it,:iir moiliv,;41isir ; 'Ng 111' 'weed “ INIlliaiiik '4100, .1..dikill11141111b* a \11111k,... .., 8 , ‘,- ..4'... , ' 1e•., 8 ;;11 • CP # o1114,v1ie..11l.11.1l11c1 o,7.LX-0i 11,iiE11111li1i11l11 . ...'kV'''itSA:',-1°.•1111 .1.811141181—401ft r, i68 MillAs .14 I ©2006:Lakehaven Utility District neither warrants nor guarantees the accuracy of any facility information shown.Facility locations and conditions are subject to field verification. http://coluiiibia/lion/rnap.aspx 7/13/2012 • • LAKEHAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form Requested By: Date: KRB 10/19/1999 Location to be Modeled. TB ' SW 344w ST& 12 AVE SW(approx.) Lakehaven v4 Section Grid: G.-11 intenection: SW 344Th/12T11 SW Add,Description: See attached map Pressure Zone: 538 ---- __ Results By: Date: Model Rim No.: JCB (form update 3/17/11 10/22/1999 Master Water System Model 2007 net BIA) FF#133 Condition Pressure(psi) Flow(gpm) Static 46 0 Fire Flow 20 3000 NO IES: Lakehaven's adopted level of service goals for fire flow rates are 1000 gpm within single family residential areas (including duplexes) and 2500 gpm for multi-family, commercial, industrial areas. Model results depict the theoretical performance of the water system under high demand conditions and are not guaranteed to represent actual system performance. A design professional should be consulted for site specific design purposes. The calculated fire flow capacity in the above table is based on a currently available residual system pressure of 20 psi at the location modeled. The model indicates that Lakehaven's standard maximum allowable velocity of 10 ft/s is exceeded at a fire flow rate above 2500 gpm. Fire flow capacities greater than 2500 gpm may be accommodated through water system improvements. ...,,, -,.. q Form Rev.5/30/08 • ` \ .-tea p ---,..c--2---1,-;-----7 _ %'< tv Ctt �„a. • =tv ti;cT.t n �\,,.-1 l 1 ';$ ". y,.� ,,rte il� .r , -r 11 5v-i„.:\ ,- Sam + • «, �{—^^ ,y ¢*" U-"/l. *19 ;a'�))off•-'[-"•�a- � A��p-��r-} YY 4> 'T µ5"-SA.... • 6 fit,fY j �` <J \-/�(•f' ,\ [7- ,. 7 ,,,, ,., . ,. .r... , , ,_ V,. S ral 69 1r"tm 16 Y1 _ _ 767,,17'011 str .4411114%.T. `N a pQj1J 0-7 { ' [1. • d 7 Ea ,t .4- 69 '• X `,— . OF ![�1`C 7.- 69 ,- .s 6$ yVa' as ` • •a.1 Y� 11 i9 8 a 4 9 i? .n -. 1° \:I !3.411-1 Pl : a,rp-a �.' 1.r , , u a s� 1, JJ`' U 5 n _ a I af" sn ( [- a U t`j., {n 11 �, t.} t`13 4d ' '��n U. .1q al - < M +1 7 ,, +. i,5 S5 I p.p..� ,,, r to JB _ v, r R •.1.� 6 - z M i [�1'trC1 Ile% w s ata yr �" a 1t'C)I ,`�'1' `"' 3 �� Via. „r-tror. ry �G__.2. � lie _ EL ;�t`1 ICY . f E1.69 - V - ,,,,.., 21 A N Y za0000: ii frog"" +ifi• —,a. •f. ,�� s¢Y 5< iia ��� X9`3' .. f }d �.ne L_ i lK as ,. ..... /f x • a w, (\ 4 ar a / .:.d� ,t !b / x ^ ),.. 11 l3 �` 06 37 l' ` S_. i yY ]$. rillr `R a5 s ' � "/® to ��.6 : -.-.._ Sb .`_.'� 4Q .. -'�" +v �'rr� - Apr" �..._ ,) 1� r•1 �t4VIF ba 1s y �'�GYl.. as cv iuift.0 `• t. ' 1fj )bl �` I .. - ( 111{ tv711 3a r e1 „: m1- r 'f.� ''�, l S • . : , LAKE HAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form Requested By' Date: Kathy Brown 03118/98 Hydrant Location: See attached site plan 1/4 Section: G-11 In tersection. ' 10th Ave SW & SW Campus Drive Add. Description: nr 5ut TS, e : - vr�ra s knuu li ACTfl NU.; _. John. Bowman " 03/20/98 95�,UDSFF.INP FF #61 ConditiofPressure (psi) Flow (gp ) Static 91 0 ' Fire Flow 20 6300 NOTE: The fire flow analysis was performed at the 10" pipe crossing near 10th Ave SW and Campus Drive, On-site fire flow estimates would have to be determined during design of the water system improvements, This fire flow rate will cause velocities in excess of 10 /s within the water distribution system and pressures in some areas to drop below 20 psi. A fire flow rate less than 3200 gpm will maintain flow velocities below 10 f/s and system pressures above 20 psi. There is no guarantee that the Hydraulic Model results will represent actual system performance. Model results depict the theoretical performance of the system under high demand conditions. Field measurements should always be obtained for design purposes. v A t i --- /, \ i 7...er[v---1--- . '---,, ''',. '-.-. ,i,.„;•-....„, r .,,. ..e,,..2., +4-4.14 * +. .4. ' "k '4.•-:.. .\,./.',...„/ 1.,''',.. '''' '...t.::'--"."-------tf,. ' -' , og 56 ,,,,,,....----.---- \ ......„. ...a•, ' 4 C) &AN .s______1:6 72,'''. lip • .\ '*------...„,..,,,,,._ ... ---.6.--- ------i-r-- 0 2: . 413‘,.... .......,.: ) , ---- ___ -- ----- ------.. 41.4, ---, • __________ ----------- ., ,., ,.....p.„; .„.> ,0 _ ‘. 4.--"-- .. , L/6) \ , : , , ,/1 : / ,-"1 „ , ..,.....,", , , , ,- ,-' , -- , \/ , -- - -, r 59 _ / ...\)// / 7 /1 / / -,' ,, / 56 of a. e AV 'L,'" / 6O e'''''' .4" 9._. )` e e / e 9.9 .. A . r' r / .z , C•k 55 o- 4 ' „,, 40 - 22.0 48 S. '' •///‘5bi 44-'14',,,e, / 7.<4.4.............,."Tr'Dt r \ / / r .., e e 21 „ft 027 .0.„ 28 c,6 N ,, ,,- kt'S`‘ As 43 *4 0 51 .- rv--.-s, ,..- 419 4'''` -• • <6''' ' - , ,, e / 44 k, 4Se ,' .,7 , t4.: ,., At7 e .., -,' - •''` \ <-\\ . 41 ...- 4- 6 i 1 y G.' ...449 ly / e' C , • - (),' .."' \-) 40 •.a. illi ._ „ 16 - 41,4 47 kc3 0, ' OCI 4'.411111L'4 111111L-WA111111 S / '' 15 .0 • .._,,,,,,_______i____,,SCALE 100 516Tom WO IS BASED UPON Mr E 1 m000lME mtForly/MoM IT S Di' 2 01 FOR Pt/4MM puRpOSES MX NOT GUARANTEED 10 SNOW ADD ANASUNENENTR. 1...,_ " ri< . . 11—I ". 'Nit. n 1 ,..,.- . T I T Y I L U T FACILITY MAP F31627 1st Avenue S. Fedorot 1,499 995s14i .14911 DISTRICT ....,,s.. „ . TOT R 19.. PROPERTY/LOT LINE Scale: RIGHT OF WAY LINE For: ROAD CENTERLINE — EDGE OF PAVING/CURB LINE 18215 72ND AVENUE SOUTH KENT, WA 98032 CONTOUR LINE /'' '302_-- ' STORM DRAIN CATCH BASIN IN STORM DRAIN LINE —D— SANITARY SEWER MANHOLE 12815 CANYON RD E, STE F SANITARY SEWER LINE — SANITARY SIDE SEWER LINE SS CLEAN OUT PUYALLUP, WA 98327 • — — — _ — — — — — — WATER METER WM WATER MAIN LINE W FIRE HYDRANT FH AIR VACUUM VALVE ASSEMBLY NATURAL GAS STUB . G POWER STUB OP CONCRETE 0 NEW IMPERVIOUS/DRIVEWAY ROOF DOWNSPOUT CONNECTION ------+ ------ RETAINING WALL POINT OF MEASUREMENT Q SILT FENCE • • LOT SIZE = 5,236 SF LOT ADDRESS: 813 SW 341ST STREET FEDERAL WAY, WA 98023 IMPERVIOUS COVERAGE: TOTAL IMPERVIOUS: 2,152 SF LEGAL DESCRIPTION LOT 34 OF THE PLAT OF ROOF: 1,784 SF WYNSTONE EAST, RECORDED DRIVEWAY: 232 SF UNDER AUDITOR'S FILE NO. WALKWAY: 34 SF 20121205001817, RECORDS PATIO: 102 SF OF KING COUNTY, WASHINGTON. BSBL FRONT: 10' GARAGE: 20' FROM R SIDE: 5' REAR: 5' L=15.36'----\ INSTALL SILT FENCE AS SHOWN e POWER STUB (APPROX LOCATION) o \ / 'p,\ 'O \ 2'X10' PERFORATED PIPE CONNECTION TRENCH PER 2009 KC SWDM FIGURE C.2.1 1 ^A APPROX. LOCATION, CONTRACTOR TO FIELD LOCATE VIONU RAP OS (DOWNSPOUT CONNECTION)(TYP) °gig"ed SMS Scale: EAVE For: LOT 34 2778 C \ \ Q 18215 72ND AVENUE SOUTH KENT, WA 98032 LENNAR NORTHWEST INC. ` " 33 \ \a\ (425)251-6222 (425)251-8782 FAX 12815 CANYON RD E, STE F Av°Ye -BIAS Vertical N/A 4' S^ G( �. .4.� CIVIL ENGINEERING, LAND PLANNING, GI iDtKYitell` CAAAOl1Af1/LA?A� CCO .1- PUYALLUP, WA 98327 • — — — _ — — — — — — °gig"ed SMS Scale: GHgVs For: AI Horizontal Q 18215 72ND AVENUE SOUTH KENT, WA 98032 LENNAR NORTHWEST INC. a,ec*ey BMs (425)251-6222 (425)251-8782 FAX 12815 CANYON RD E, STE F Av°Ye -BIAS Vertical N/A 4' S^ G( �. .4.� CIVIL ENGINEERING, LAND PLANNING, GI iDtKYitell` CAAAOl1Af1/LA?A� CCO .1- PUYALLUP, WA 98327 • — — — _ — — — — — — File:P:\16000s\16305\lots\16305—Wynstone Lots.dwg Plot Dote/Time:4/22/2013 10:36 AM AJONES KI 4' MAX ROCKERY mmmr� p p rn E1 Y ()1)�xFEDERAL JVR m O d n � c HOUSE PLAN #` Title: RESIDENTIAL SITE PLAN 11 �, WYNSTONE-LOT 34 o, .. PARCEL 957850-0340.