Loading...
14-102775City effederal Way Community & Econ. Dev. Services 333258th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 0 FILE Project Name: WYNSTONE EASE' LOT 59 Project Address: 909 SW 338TH ST fuilding - Single Fdn ily Permit #: 14-1027754 -SF Inspection Request Line: (253) 835-3050 Parcel Number: 957850 0590 Project Description: NEW - Construction of a 2,845 square foot 2 -story single family residence with basement, 60 square foot covered entry and 372 square foot covered garage. Includes plumbing & mechanical. ***4 bedrooms; $369,950 estimated selling price*** Owner Applicant Contractor Lender LENNAR NORTHWEST INC LENNAR NORTHWEST INC LENNAR NORTHWEST INC OWNER IS LENDER 33455 6TH AVE S SUITE 1-B 33455 6TH AVE S SUITE 1-B LENNANI893QG (11/7115) Plumbing to be Included?.......................................Yes FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 33455 6TH AVE S SUITE 1-B family) FEDERAL WAY WA 98003 Census Category: 101- New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load- oadFloor Type V - B FloorAreas . ft. 2,905 0 0 0 Additional Permit Information New / Additional Sq. Feet -1 st Floor....................1200 Occupancy # 1 -Area (Sq. Feet).............................2905 New / Additional Sq. Feet - 3rd Floor....................0 No New / Additional Sq. Feet - Basement...................518 0 Occupancy #I - Construction Type. ....................... Type V - B New / Additional Sq. Feet - Garage .......................372 60 Occupancy # 1- Class.............................................R-3 Plumbing to be Included?.......................................Yes Zoning Designation...............................................RM Occupancy # 1 -Use ............................................... Residence (1 or 2 family) Ducting........................................... 1 Furnaces ......................................... 1 Hot Water Tanks ............................ 1 New / Additional Sq. Feet - 2nd Floor...................1127 Occupancy # 1 -Area (Sq. Feet).............................2905 BasicPlan?........................................................... No New / Additional Sq. Feet - Deck. ......................... 0 Mechanical to be Included? ................................... Yes New / Additional Sq. Feet - Other .......................... 60 New / Additional Sq. Feet - Total .......................... 3277 Zoning Designation...............................................RM 3600 ' Mechanical Fixtures Fans................................................ 7 Gas Piping ...................................... 1 Plumbing Fixtures Bathtubs ......................................... 2 Dishwashers................................... 1 Fireplace Inserts ............................. 1 Gas Pipe Outlets ............................. 4 Laundry Washer Outlets .............. Lavatories....................................... 6 Showers.......................................... 3 Sinks............................................... 1 Water Closets ................................. 4 Hose Bibbs..................................... 2 PERMIT EXPIRES Monday, March 23, 2015 Permit Issued on Wednesday, September 24, 2014 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: Q�2� LAW & N -e� 3 -3J- PA G City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: WYNSTONE EAST LOT 59 Permit #: 14102775 -01 -SF Address: 909 SW 338TH ST Includes: #1 #2 #3 #4 Occu an Class: R-3 Construction Type: Type V - B Occupancy Load Floor Area (sq. ft.) 1 2,905 0 0 0 Owner Name: LENNAR NORTHWEST INC ress: 33455 6TH AVE S SUITE 1-B FEDERAL WAY WA 98003 Building Official 3 —31 - I7 Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severiy affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner / occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said shucture or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. CITY OF Federal Way PERMIT #: 14 -102775 -01 -SF THIS CARD IS TOIN ON-SITE Construction InrZ:tion Record INSPECTION REQ (253) 835-3050 Address: 909 SW 338TH ST Project: LENNAR NORTHWEST INC FEDERAL WAY, WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. SWM Precon Site Mtg (4400) Initial Erosion Control (4365) ❑ Footings/Setback (4110) Approved To be done prior to breaking ground Approved to place concrete By Date By Date By Date Drainage/Downspout (4048) By Plumbing Groundwork (4190) EJ Rough Electrical Approved 1:1Approved Final Electrical 1:1Approved Right of Way By Foundation Wall (4115) By Drainage/Downspout (4048) By Plumbing Groundwork (4190) Approved to cc concrete Approved to backfill Approved to cover By roe Dater B Date�� By Date/ Slab/Concrete Floor (4255) Underfloor Framing (4285) Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date _ By P/rL— Date (Z 3� • 1 y By PA j , Date (Z . 3,0- (1{ Shear Walls (4245) Roof Sheathing (4220) 0 Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved By Date S By Date 1 Z • j t By I> A.� Date Mechanical Rough -in (4165) ❑ Gas Piping (4125) ❑ Fire/Draft Stops (4095) Approved Approved to release test Approved By P /k -L�- Date 1 �, j ,� By Q Aesv Date By F^— Date 1-2—b Interim Erosion Control (4370) Framing (4120) prior to scheduling a Framing inspection; Approved Electrical, Plumbing &Mechanical Rough -in and Approved to insulate PN Irl k By ate �� FirdDraft Stop inspections must be signed -off and approved IBC 1093.4 By r2_ Date S— Insulation (4150) Gypsum Wallboard Nailing (4130) Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By a Date .1 � _ i S By P p, Date -ol , (S' By Date ❑ Final - Mechanical (4065) Final - Plumbing (4075) Final - Building (4050) Approved Approved Approved By Date3_ 31 -)r By PA -z— Date _3 Z�_ (S� By r-,1'7- Date EJ Rough Electrical Approved 1:1Approved Final Electrical 1:1Approved Right of Way By Date By Date By Date J INSPECTOR AREA ANDTNTE 017 INSPECTION deck va►c Dp�ueu f -a; _ be PA1- D601 -L - AN6,G* _ QL)N i boot LCCA 3 - ZS— (S A -t- _ iLt F to n L, 31-0 G, EK- A)d C '7L' -r 7- 71 04 )A cl 'TE -i — A J CITY Of 4& Federal Way PERMIT NUMBER / RECEIVED • !i1G 2 1 2 01 4 0 bowl PERMIT APPLICATION CITY OF FEDERAL WAY CDS l L(LA 7 7s TARGET DATE SITE ADDRESS SUITE/UNIT # 909 SW 338th Street PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL # $ 185,020.00 RS7.2 957850 _ 0590 TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Wynstone East Construct new SFR 4 bedroom, 3.5 bath home PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER Lennar NW Inc. 253-590-2208 MAILING ADDRESS E-MAIL 33455 6th Ave South, Unit 1 B norena. edgecombe@lennar.com CITY STATE ZIP Federal Way WA 98003 NAME PHONE Lennar NW Inc. 253-590-2208 MAILING ADDRESS E-MAIL CONTRACTOR 33455 6th Ave South, Unit 1 B norena. edgecombe@lennar.com CITY STATE ZIP FAX Puyallup WA 98003 WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSE(ESS LICENSE # LENNAN1893QG 11/ 07 15 20 -13 -100182 -00 -BL NAME PRIMARY PHONE Lennar NW Inc. 253-590-2208 APPLICANT MAILING ADDRESS 33455 6th Ave South, Unit 1B E -MAD, norena. edgecombe@lennar.com CITY STATE ZIP FAX Puyallup WA 98003 NAME PRIMARY PHONE PROJECT CONTACT Norena Edgecombe 253-590-2208 MAILING ADDRESS 33455 6th Ave South, Unit 1 B E MAD. norena. edgecombe@lennar.com (The lndivuival to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) Puyallup WA 98003 PROJECT FINANCING NAME N/A - Owner Financed OWNER -FINANCED Required value of $5, 000 or more MAILING ADDRESS, CITY, STATE, ZIP PHONE (RCW 19 27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. l further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and flied against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: DATE 8/18/2014 PRINT NAME: orena dgecombe Bulletin #100 — January 1, 2013 Page 1 of 3 k:\Handouts\Permit Application s MECHANICAL PERMIT CRITICAL ARRAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF ECHANICAL WORK 1$4,800 . 00 Indicate how many of each hipe of fixture to be installed or relocated as part of this project. Do not include existing fLxtures to remain. AIR HANDLING UNITS 7 FANS GAS PIPE OUTLETS OTHER (Descnbe) AIR CONDITIONER 1 FIREPLACE INSERTS HOODS (eommere,at( to be installed or relocated as BOILERS 1 FURNACES HOT WATER TANKS (cas( COMPRESSORS 4 TOILETS GAS LOG SETS REFRIGERATION SYST - DUCTING 4 GAS PIPING WOODSTOVES 3 GENERAL INFORMATION CRITICAL ARRAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF PLUMBING WORK PLUMBING PERMIT Lakehaven Lakehaven 1$7,900.00 EXISTING/PREVIOUS USE LOT SIZE (Iu Squue Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? None 5196 Indicate how many of each type offixture ❑ Yes 4 No to be installed or relocated as part of this project Do not include existing res to remain. 2 BATHTUBS (or Tub/Shower Combo) 6 LAVS ([land S, ks) 4 TOILETS WATER PIPING DISHWASHERS - RAINWATER SYSTEMS URINALS OTHER (Descnbe) DRAINS 3 SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS 1 SINKS (K,mhe /Uehry( WATER HEATERS (eleee,e( 21 HOSE BIBBS k, SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL ARRAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS None Lakehaven Lakehaven None EXISTING/PREVIOUS USE LOT SIZE (Iu Squue Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? None 5196 ❑ Yes d No ❑ Yes 4 No RESH)ENTIAL - NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE AREA DESCRIPTION Occupancy Group(s) FIRST FLOOR (or Mobile Home) None 1200 1200 ve COVERED ENTRY None RPMu 60 60 f� s t•?; .' .IM •tib""- -Z" - �'�• GARAGE W1 CARPORT ❑ None 372 372 ADDITION Eusmra '..roam Area Totals - 3277 TMAL 3277 Mf -40 COMMERCIAL — REMODEL/TENANT IMPROVEMENTS Area k, Construction ESTIMATED SELLING PRICE $ 369,950 # OF BEDROOMS 4 COMMERCIAL — NEW/ADDITION Area Construction # of AREA DESCRIPTION Occupancy Group(s) Additional Information in Ware Feet ve Stories .. � ^"'". 'Eni+' '4 ^N� �' f� s t•?; .' .IM •tib""- -Z" - �'�• ADDITION COMMERCIAL — REMODEL/TENANT IMPROVEMENTS Area Construction # of AREA DESCRIPTION Occupancy Group(s) Additional Information is Square Feet a Stories w�.,�, Vit? �y'y.Y •^F G-- Y•; i " I:' .An`� vi R.A 2 h., �.'. :'n :}. f.^ . kYN: ,_ TENANT AREA ONLY '��YA< 'rF;-.--- h:'Vr.• •.4.: `Yc..S�f+� `'S - .: 4, \k".. .:' M.,Y..+x'..3yr' "�"y"�',':�."�•,�' +_kyr:.:} .y�r _:Y_�4Fh..F+'R•'.•x' ��'`,.'. '+yi'+ Vi' rAM.ry `y,•�y}� Epp,,��;;�� . _ ..iY.. i'•O E��'r�'y�R, % 1. y-�,.�, , ,ygnuli•. Bulletin #100 —January 1, 2013 Page 2 of 3 k:\I-Iandouts\Permit Application Federal Way REW,IVED JUN 112014 CITY OF FEDERAL WAY CDS • S9 PERMIT APPLICATION PERMIT NUMBER [4— _ ( 0 Z —7 -S SF TARGET DATE �� 1 SITE ADDRESS SUITE/UNIT # 909 SW 338th Street PROJECT VALUATION ZONINGASSESSOR'S TAR/PARCEL # $ 185,020.00 RS7.2 957850 _ 0590 TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Wynstone East Construct new SFR 4 bedroom, 3.5 bath home PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER Lennar NW Inc. 253-590-2208 MAILING ADDRESS E-MAIL 12815 Canyon Rd. E., Ste. F norena. edgecombe@lennar.com CITY STATE ZIP Puyallup WA 98373 NAME !HONE Lennar NW Inc. 253-590-2208 MAILING ADDRESS E-MAIL CONTRACTOR 12815 Canyon Rd. E., Ste. F norena. edgecombe@lennar.com CITY STATE ZIP FAX Puyallup WA 98373 WA STATE CONTRACTOR'S LICENSE N EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE R LENNAN1893QG 11/ 07 15 20 -13 -100182 -00 -BL NAME PRIMARY PHONE Lennar NW Inc. 253-590-2208 APPLICANT MAILING ADDRESS 12815 Canyon Rd. E., Ste. F LMAIL norena. edgecombe@lennar.com CITY STATE ZIP FAX Puyallup WA 98373 253-446-6751 NAME PRIMARY PHONE PROJECT CONTACT Norena Edgecombe 253-590-2208 MAILING ADDRESS 12815 Canyon Rd. E., Ste. F E•MAD. norena. edgecombe@lennar.com (The indwidual to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) Puyallup WA I 98373 PROJECT FINANCING NAME N/A - Owner Financed OWNER -FINANCED Required value of $5, 000 or more MAILING ADDRESS, CITY, STATE, ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE: Ak�iAcyDATE 5/19/2014 PRINT NAME: NOrena EdgeCOm Bulletin #100 —January 1, 2013 Page 1 of 3 kAHandouts\Peimit Application t IV 0 • GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR VALUE OF PLUMBING WORK VALUE OF ECHANICAL WORK MECHANICAL PERMIT Lakehaven Lakehaven 1$4,800 . 00 Indicate how many of each type of $ 7,900.00 re to be installed or relocated as part of this project. Do not include existing Fixtures to remain. AIR HANDLING UNITS existing tures to remain. FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER DISHWASHERS FIREPLACE INSERTS HOODS (commercial) OTHER (Describe) BOILERS 3 SHOWERS FURNACES HOT WATER TANKS (cap( DRINKING FOUNTAINS COMPRESSORS WATER HEATERS (eieco-Nc GAS LOG SETS REFRIGERATION SYST SUMPS DUCTING 5 GAS PIPING WOODSTOVES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR VALUE OF PLUMBING WORK PLUMBING PERMIT None Lakehaven Lakehaven $ None EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) $ 7,900.00 Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing tures to remain. 2 BATHTUBS (nr Tub/Shower combo( 6 LAVS (Hand Sinks( 5 TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS 3 SHOWERS VACUUM BREAKERS In uare Feeta DRINKING FOUNTAINS 1 SINKS (Kachen/UmNry) WATER HEATERS (eieco-Nc 21 2 HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS None Lakehaven Lakehaven $ None EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTDIG FIRE SPRMBLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? None 5196 ❑ Yes d No ❑ Yes Q( No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION Area Occupancy Group(s) AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE Stories I :- FIRST FLOOR for Mobile Home) None 1199 1199 AREA DESCRIPTION Area Occupancy Group(s) Construction # of Additional Information In uare Feeta COVERED ENTRY None 105 105 fj s �. :p GARAGE R1 CARPORT ❑ None 430 430 • "s :. }` •'� IF:s ��r £�t%y. — ."�'£' :— �fP:il!'a'•. •'Y';T, .�.' •i+�'-.. t .�`k"'.�. i `- Area Totals �n 3277 AL 3277 3277 ESTIMATED SELLING PRICE $ 369,950 # OF BEDROOMS 4 COMMERCIAL — NEW/ADDITION AREA DESCRIPTION Area Occupancy Group(s) Construction # of Additional Information in Square Feet a Stories ADDITION COMMERCIAL — REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area Occupancy Group(s) Construction # of Additional Information In uare Feeta Stories s �. TENANT AREA ONLY • "s :. }` •'� IF:s ��r £�t%y. — ."�'£' .: jii'j �fP:il!'a'•. •'Y';T, .�.' •i+�'-.. t .�`k"'.�. i `- Bulletin #100 – January 1, 2013 Page 2 of 3 k:\Handouts\Permit Application Web date: 04/28/2007 FILs op Department ni Developmsrrt and En%4ronmental Semic Building services Division RECEI VD ERU 900 Oakesdale Avenue Southwest � i 206-2"00Renton, Washington 98057-5212 For altemate formats, Call 206296-6600. N zo6-2oo TTY 206-298-7217 204 - This certificate provides the Public Health - Seattleg County Department and the Department of Q>�^I5 Development and Environme4ifidt�i %* Mn necessary to evaluate development proposais� po not write in this box CU5 14& 4• 1 Q 277.5 77.5 . Number Name MBuliding Permit $Wrellminary Plat or PUD ❑ Short Subdivision ❑ Rezone or other: ✓ Applicant's name: Proposed use. •S 40cation (attach map and legal description if necessary): R f)N5 QO 9 -4' 4 b ' `700 SLA3 Citmfts bAt\36 1' Water pUrveyor inforiiiation: d 1. ❑ a. Wates can be provided by service connection only to an existing (size) water main that is OR feet from the site. b. Water service will require an improvement to the water system of: am - 0 feet of water main to reach the site; and/or (2) The construction of a distribution system on the site, and/or MU 19T ticAcce is Y ird (3) Other (describe)-. CO Rte Wr DEW1.6 E R M>T"31,6 N 0k Q1, iE 1Wr 60. 2. a. The water system is in conformance with a County. approved water comprehensive pian. OR !+aiVA%)60, ❑ b. The water system Improvement is not in conformance with a County approved water comprehensive plan and will require a water comprehensive plan amendment. (This may cause a delay In issuance of a permit or approval.) q/ 3. IN a. The proposed project Is within the corporate limits of the district, or has been granted Boundary Review Board approval for extension of service outside the district or city, or is within the County approved service area of a private water purveyor. OR ❑ b. Annexation or Boundary Review Board (BRB) approval will be necessary to provide service. 4. a. Water is or will be available at the ratg of flow and duration indicated below at no less than 20 psi measured at the nearest fire hydrant �"j_5-m 'tJ-3Go feet from the building/property (or as marked on the attached map): Rate offlow at Peak Demand: 0 leas than 500 gpm (approx. gpm) 0 500 to 999 gpm 01000 ppm or more 0 flow test of gpm 0 calculation of Dwadon: 0 less than 1 hour 0 r.1 hour to 2 tours 10 2 hours or more Other �Lras g� :1�QF' OR (Note: Commercial building permits *Mch include multifamily structures require flow test or calculation.) ❑ b.. Water system is not capable of providing fire flow. 5. a. -Water system has certificates of water rights or water right claims sufficient to provide service. OR ❑ b. Water system does not currently have necessary watet rights or water right claims.. �! Comments/conditions: W A'P` O- _ 511qR.ut,Cl5 CONNGIcjjb)j Aff(1 �►"7u $ tR. ALI W I certify that the above water purveyor information is true. This certification shall be valid for one, year from date of signature. LAKEHAVEN UTILITY DISTRICT Btu,. 06zb Agency name Slgnatoryna e Title Sign '?' /^ j2. Date --- - _ _ _ ......:�. _ In �'R Pressure Zone; Lowest Highest Etevatton of Property 'iib 91 �- ; Eat. Min. Pressure . psi -,. Max. The District, at its sole discretion, reserves the riga to delay or deny water service based upon capacity limitations In District and Other Purveyor facilities. Water availability form Rev. 05-19-2003 Page 1 of 1 • � Page 2 of ' -2 OF 1 00 r 00 49 CO CO 00 XJ to CDCO f r- 4 a► Cp M r o 1� 12 CC) 1 � 1 � o0 CO 1 339 rN $ r � v 41=L Hydrants: +i- 5 36G a,,cr main: +; ', 5 ;c xt� TO Co' i ,,� —'a lot, kk CO d 407(1 �, ry V w CO 2006: Lakehaven Utility District neither warrants nor guarantees the accuracy of any facility information shown. 1-acmty locations and conditions are subject to field verification. http://cOlumbia/lion/inap.aspx 7/13/2012 0 0 LAKEHAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form Requested By: KRB Date: 10/19/1999 Location to be Modeled: SW 3441-11 ST & 12 AVE SW (approx.) L ak-ellaven /, section Grid: 10/22/1999 Intersection: SW 344"1' / 12TH SW Add, Description: See attached map Pressure LOne: 538 Results By: Date: Model Run No.: JCB (form update 3/17/11 10/22/1999 Master Water System Model 2007.t1et BTA) FF 9133 Condition Pressure (psi) Flow (gpm) Static 46 0 Fire Flow 20 3000 MOTES: Lakehaven's adopted level of service goals for fire flow rates are 1000 gpm within single family residential areas (including duplexes) and 2500 gpm for multi -family, commercial, industrial areas. Model results depict the theoretical performance of the water system under high demand conditions and are not guaranteed to represent actual system performance. A design professional should be consulted for site specific design purposes. The calculated fire flow capacity in the above table is based on a currently available residual system pressure of 20 psi at the location modeled. The model indicates that Lakehaven's standard maximum allowable velocity of 10 ftls is exceeded at a fire flow rate above 2500 gpm. Fire flow capacities greater than 2500 gpm may be accommodated through water system improvements. Form Rev. 5/30/08 G� �� I., � 6p r -- --- 6p 1 k—�' rD 9� . :s Al. ���xs e C' 17 V ,q :4 S _ to e p ✓ ■a „, ..,. _ .. -._ .,tom.:'• .. u y t' a7 --. st sy, o • _f» u it _, 4f 9U se ,� �• ,r, >a.w .x ti� '�<—=1:-��h,N, G, ani } �,`(t to . 57 `ti• �q . •'`h y/q S JERll'0 D Boa ,a "� ` ' ' e _ H If1 114 rx s, ` 5t r" jie•r-,e;,, � W is u ` v 4 ... ,,. , is F•o to31 r I >o .. t� tlt. °'-01 5Y .! •1� 41 0 9 LAKEHAVEN UTILITY DISTRICT Hydraulic Model Fire Flow Estimate Request/Reporting Form John Bowman -ate--- Date: 03/18/98 Requested By: Kathy Brown Hydrant Location: See attached site plan 1/4 Section: G-11 Intersection: 10t" Ave Sha & SVJ Campus Drive Add. Description: John Bowman -ate--- Rull M. . 03/20/98 95LUDSFF.INP FF1E61. Condition'' Pressure (psi) Flow (gpm) Static 91 0 Fire Flow 20 6300 NOTE: The fire flow analysis was performed at the 10" pipe crossing near 10t" Ave SW and Campus Drive. On-site fire flow estimates would have to be determined during design of the water system improvements. This fire flow rate will cause velocities in excess of 10 f/s within the water distribution system and pressures in some areas to drop below 20 psi. A fire flow rate less than 3200 gpm will maintain flow velocities below 10 f/s and system pressures above 20 psi. There is no guarantee that the Hydraulic Model results will represent actual system performance. Model results depict the theoretical performance of the system under high demand conditions. Field measurements should always be obtained for design purposes. mac' ). :,�_` 5 -",(---_- .x. � �" •,. / C. i r� �3 JO T z:~ W✓ ��\ � •±,rtt:t•� OAC. ✓ 4�'� ,.6d 6 2S7, zs 'v zz�r 28 U94�ttf" �"tis.�a•[iA,' y9 'V/'1 So 49 tF1.50�^9f +•�� 52 Do 6 , ©AAs s .4•_IrOl Asv.s. r-tn roo s- V�57 Yeo C' 56 y L 60 A 24 16 82 23 E� �co•'63 ag 22 24 54 1? �- 53 P 21 � 17 27 sy 52 20 F e 5' 19 43 29 30 to 44 .,� �y J 50 ' p°4 42 Y ''a. 31 4 41 32 49 40 75 312 FACILITY _MAP 39 49 UTILITY 33 '\ \ 47 1 48 34 N s J � 1Y ayeE s 5_ cgLE �N FEEi r loo Otytp 6 9ASED VPW iME t �[ nlF4etN71W1. R 6 ut [ P �gR1K PURPDSES GtIL� .. ts4R 70 sMDW �. HAN/'EN DISTRICT G-1 PROPERTY/LOT LINE A RIGHT OF WAY LINE AIR VACUUM VALVE ASSEMBLY ROAD CENTERLINE — EDGE OF PAVING/CURB LINE --------- CONTOUR LINE NATURAL GAS STUB STORM DRAIN CATCH BASIN EAVE` I� X16.68' 296 l {— STORM DRAIN LINE D SANITARY SEWER MANHOLE CONCRETE SANITARY SEWER LINE ---- — SANITARY SIDE SEWER LINE SS --- CLEAN OUT :rr WATER METER %WM WATER MAIN UNE W FIRE HYDRANT FH S* 338TH STREET _ 13=1,032.50 D=02'57'40' INSTALL SILT ,.F 4� FENCE AS SHOWN M"Y IDF FEUERiaf_'ddAY CDS LOT SIZE = 5,196 A PORCH AIR VACUUM VALVE ASSEMBLY LOT ADDRESS: TOTAL IMPERVIOUS: 2,208 SF (42.5%) 909 SW 338TH STREET R — NATURAL GAS STUB a G�GARAGE EAVE` I� X16.68' 296 l {— POWER STUB OP CONCRETE LEGAL DESCRIPTION _____ Id"RD �N85'O6' NEW IMPERVIOUS/DRIVEWAY C. �; '_, ------- � _� �-__- PATIO: 72 SF WYNSTONE EAST, RECORDED �__ ROOF DOWNSPOUT CONNECTION ------ -®--^—�j/-^-'�-(- N5 BSBL 20121205001817, RECORDS RETAINING WALL OF KING COUNTY, M - POINT OF MEASUREMENT Q �i SIDE: 5' t q 28' h POINT OF ELEVATION i SILT FENCE 17.56'1 I Us DS LOT SIZE = 5,196 A FILL ROCKERY' I IMPERVIOUS COVERAGE: LOT ADDRESS: TOTAL IMPERVIOUS: 2,208 SF (42.5%) 909 SW 338TH STREET ---___ FEDERAL WAY, WA 98023 - — _'— ROOF: 1,821 SF DRIVEWAY: 280 SF LEGAL DESCRIPTION _____ Id"RD �N85'O6' WALKWAY. 35 SF LOT 59 OF THE PLAT OF - - S6"W 60.98' -' - PATIO: 72 SF WYNSTONE EAST, RECORDED j8"RD Sb UNDER AUDITOR'S FILE NO. — BSBL 20121205001817, RECORDS FRONT: 10' OF KING COUNTY, REINFORCED FILL 72 GARAGE: 20' FROM R WASHINGTON. ROCKERY MAX SIDE: 5' HEIGHT 10.0' REAR: 5' Scale 71 Daae -B,5- IVGHA& 18215 72ND AVENUE SOUTH For: Dron Aa Horizontol Q' KENT, WA 98032 LENNAR NORTHWEST INC. =zo (425)251-6222 12815 CANYON RD E, STE F m 2 Checked a"s 4 (425)251-8782 FAX VerVcal y PUYALLUP, WA 98327 App—ed eMs e' CIVIL ENGINEERING, LAND PLANNING, Date 5/2/14 NVA �r"'VG+ENG1SURVEYING, ENVIRONMENTAL SERVICES (253) 590-2205 File:P:\16000s\16305\lots\16305-Wynstone Lots.dwg Plot Dote/Time:5/2/2014 12:20 PM DBRIGGS 2'x10' PERFORATED TROOF DOWNSPOUT PIPE CONNECTION TRENCH ONNECTION PER 2009 KC SWDM FIGURE C.2.11.A APPROX. LOCATION, CONTRACTOR TO FIELD LOCATE ...... _................_...... ,j MAP A 00 ma7� HOUSE PLAN # 3' h a. Job Ntco Title: RESIDENTIAL SITE PLAN `o WYNSTONE-LOT 5916w;, PARCEL 957850-0590 Sb O z�''� PROPERTY/UT UNE w— I I 11 GA 1AVE — -- - -11 �-_ -1 RIGHT OF WAY LINE G Svv 338TH POWER STUB OP S-rfje ROAD CENTERLINE 1— 7-1 L=53.36' EDGE OF PAVING/CURB LINE R=1,032.50 CONTOUR LINE D,02-57'40" INSTALL SILT FENCE AS SHOWN STORM DRAIN CATCH BASIN ------..u.-____._ jOiL L L STORM DRAIN LINE —D— PATIO: 67 SF SANITARY SEWER MANHOLE l-T— SANITARY SEWER LINE 0 W I PLANTER SANITARY SIDE SEWER LINE _$s— ROW SIDEWALK CLEAN OUT 0 12 WATER METER &Wm DI 1p BSP WALK �R WATER MAIN LINE Vf--53 SO DS FIRE HYDRANT FIT H5.47 PORCH 19 `16 6.59 AIR VACUUM VALVE ASSEMBLY w— I I 11 GA 1AVE — -- - -11 �-_ -1 NATURAL GAS STUB G 58 POWER STUB OP 4 CONCRETE 1— 7-1 - -296-, - NEW IMPERVIOUS/DRIVEWAYr7 t ROOF: 1,823 SF377---- 1 ROOF DOWNSPOUT CONNECTION ------..u.-____._ jOiL L L RETAINING WALLBUILDING - - N85' 60.98 - - - - - - - PATIO: 67 SF WYNSTONE EAST, RECORDED l-T— POINT OF MEASUREMENT 0 raENVELOPE� FRONT: 10' GARAGE: 20' FROM T 2 POINT OF ELEVATION 0 "'i 1 SILT FENCE 17,59'1 I DS LOT SIZE - 5,196 SF PERFORATED RATIO, FILL ROCKER IMPERVIOUS COVERAGE: LOT ADDRESS: PER 2009 KC SWDM TOTAL IMPERVIOUS: 2,145 SF (41.3%) 909 SW 338TH STREET LOCATION, CONTRACTOR TO FIELD LOCATE FEDERAL WAY, WA 98023 ROOF: 1,823 SF377---- DRIVEWAY: 220 SF WALKWAY: 35 ST LEGALDESCRIPTION-- LOT 59 OF THE PLAT OF - 8"PD - - N85' 60.98 - - - - - - - PATIO: 67 SF WYNSTONE EAST, RECORDED l-T— BS8L UNDER AUDITOR'S FILE NO. 20121205001817, RECORDS FRONT: 10' GARAGE: 20' FROM T OF KING COUNTY, 72 REINFORCED FILL 71 SIDE: 5' WASHINGTON. ROCKERY MAX HEIGHT 10.0' REAR: 5' Scale: m --2'xlO' PERFORATED --ROOF ROOF DOWNSPOUT PIPE CONNECTION TRENCH CONNECTION PER 2009 KC SWDM FIGURE C.2,11A APPROX.- 0 0 LOCATION, CONTRACTOR TO FIELD LOCATE .BMS IV el"A(j0 18215 72ND AVENUE SOUTH For: 1 Drawn _Aj Horizontal KENT, 251 WA 98-62222 LENNAR NORTHWEST INC. (425)03 Checked SMS (425)251 -8782 FAX 33455 6TH AVENUE SOUTH, UNIT 1-13 Vertical 0 Appro,ed SMS 1,� CIVIL ENGINEERING, LAND PLANNING, FEDERAL WAY, WA 98003 N/A 1� SURVEYING, ENVIRONMENTAL SERVICES V,fe 8/15/14 ?�"VG E N Glll`� (253) 590-2205 File:P:\16000s\16305\lots\16305-Wynstone Lots.dwq Plot Dcite/Time:8/15/2014 9:13 AM DBRIGGS RECEIVED AUG 9, 6 2014 CM OF FEDERAL V)AY 11c MAP -0 > 70 m ;u C) IT 0 M M n 0, co -0 IHOUSE PLAN # 2845B Job Tffl"`: RESIDENTIAL SITE PLAN Number 16305 WYNSTONE-LOT 59 PARCEL 957850-0590 Sheet 1 - 1 0