19-101174 1
al
v .
• Building - Single Family
City of Federal Way Permit #:19-101174-00-SF
Community Development Dept.
33325 8th Ave S
Federal Way,WA 98003 Inspection Request Line: (253)835-3050
Ph:(253)835-2607 Fax:(253)835-2609
Project Name: RETREAT MEADOWS LOT 50
Project Address: 35829 1ST PL SW Parcel Number:724290 0500
Project Description: NEW-Construction of a 3183 square foot 2-story single family residence with a 19 square foot
covered entry and a 583 square foot attached garage. Includes plumbing and mechanical. ***4
Bedrooms;$350,000 Estimated Selling Price***
Owner Applicant Contractor Lender
LENNAR NORTHWEST INC SPENCER FITCHLENNAR LENNAR NORTHWEST INC OWNER IS LENDER
33455 6TH AVE S SUITE I-B NORTHWEST INC 33455 6TH AVE S SUITE 1-B
FEDERAL WAY WA 98003 33455 6TH AVE S UNIT I-B FEDERAL WAY WA 98003
FEDERAL WAY WA 98003
Census Category: 101 -New Single Family House
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 3,183.00
Additional Permit Information
New/Additional Sq.Feet-1st Floor 1738 New/Additional Sq.Feet-2nd Floor 1445
' 'Ilk New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 3183
New/Additional Sq.Feet-Basement 0 Basic Plans No
y Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0
New/Additional Sq.Feet-Garage 583 Mechanical to be Included? Yes
i Plumbing Work Valuation? 20000 Mechanical Work Valuation? 10000
Number of Stories 2 New/Additional Sq.Feet-Other 19
Plumbing to be Included? Yes New/Additional Sq.Feet-Total 3785
Will Certificate of Occupancy be Issued? Yes Occupancy#1-Use Residence(1 or 2
family)
Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2
Residential
Total Valuation:418,569.32
. ,+ ' ' `,"' ,e war i ..•.-1,',,,-..,'"a '` ,`
ot,s
Ducting 1 Fans 8 Fireplace Inserts 1
Furnaces 1 Gas Piping . 4 Gas Pipe Outlets 4
Hot Water Tanks 1
.'" 3°r£h�' i; , 32 ce n( 4 6 R Ms
� ii k.7 � aG" , k, r,'„:`,,;.= e_),4-4," , ,--�e4' : ti�
Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 2
Lavatories 6 Sinks 2 Water Closets 4
Hose Bibbs 2
jat
4.411
#_
PERMIT EXPIRES Wednesday,30 October,2019
Permit Issued on Friday,May 3,2019
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: Dater 3
-/ti
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance,this structure was in
compliance with the various ordinances of the City regulating building construction or use.This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: RETREAT MEADOWS LOT 50 Permit# 19-101174-00-SF
Address: 35829 1ST PL SW
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 3,183.00
Owner Name: LENNAR NORTHWEST INC
Owner Address: 33455 6TH AVE S SUITE 1-B
FEDERAL WAY WA 98003
mss'/
/moi/.ism
: ildin:Official Date
The priority foc.s in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the genera!public. Although the City has made as complete
a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises.
. `` w 4
THIS CARD IS TO REMAIN ON-SITE
CITY OF - Construction Inspection Record
Federal Way INSPECTION REQUESTS:(253)835-3050
PERMIT#: 19 101174 00 Address: 35829 1ST PL SW
Project: LENNAR NORTHWEST INC FEDERAL WAY WA 98023
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
0 SWM Precon Site Mtg(4400) 1 0 Initial Erosion Control(4365) El Footings/Setback(4110)
Approved To be done PRIOR to breaking ground Approved to place concrete
By Date ' By Date Byjf4F Date s
0 Foundation Wall(4115) 0 Drainage/Downspout(4040) 0 Plumbing Groundwork(4190)
Approved to place concret Approved to backfill I Approved to cover
By L/V Date 1��7 ; By rod Date 5/20)/1 By 44,A) Date 5/20/4
Ar
® Slab/Concrete Floor(4255) 0 Underfloor Framing(4285) 0 Floor Sheathing(4105)
Approved to place concrete Approved to sheath floor Approved to install flooring
By Date I By S Date 2,- By Date
El Shear Walls(4245) Roof Sheathing(4220) El Rough Plumbing(4230)
Approved to install siding Approved to install roofing Approved •
ByL . Date ✓ /4 By Date 4 14 (t By Date a,r 4'
El Mechanical Rough-in(4165 i El�!�,c�• Gas Piping(4125) ElFire/Draft Stops(4095)
Approved Approved to release test Approved
By jJ S Date vole/1 e/� By/Ga/5. Date 7�� By Date 7
•rn
16 Interim Erosion Control(4370) Prior to scheduling a Framing inspection; 7 Framing(4120)
Approved Electrical,Plumbing&Mechanical Rough-in Approved to insulate
in and Fire/Draft Stop inspections must be signed-
By 1111�/J ' Date 1) 1 1 1 11‘1 . off and approved. IBC 109.3.4 By �/
Date
El Insulation(4150) •as Gypsum Wallboard Nailing(4130) Ed Final Erosion Control(4375)
Approved to install wal boar Approved to install mud&tape I Approved
By -. Date a By ' 73 Date 7 a 9 (By Date
ElFinal—Mechanical 4065) ®
Final-Plumbing(4075) El Final-Building(4050)
Approved / Approved Approved
�Bty (/� Datep1207 ��By�4�S Date 2.,c/4" ..ByLt‘i Date 0,0 .
of 0 $&fAtk9.ei' Cl4t-Ae4, fr,14.4;te.
• &s - -9- /9
0 Rough Electrical ❑ Final Electrical 0 Right of Way
Approved Approved Approved
By Date By Date By Date
„"...„40010!„ RECEIVED PERMIT APPLICATION
CITY Of
Federal Way MAR 13 2019 PERMIT CENTER+33325 8th Avenue South+Federal Way,WA 98003-6325
253-835-2607+FAX 253-835-2609+permitcenter<!cityoffederalway.com
CITY OF
COMMUNITY UEVE._ ) 4 ;['
PERMIT NUMBER / _ I 0 1 / 7 t/ _ S i .
TARGET DATE
SITE ADDRESS SUITE/UNIT#
35829 1st PI SW
PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL 4
$ 175,000.00 RS7.2 7 2 4 9 0 0 5 0 0
TYPE OF PERMIT C BUILDING ®PLUMBING ®MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION
NAME OF PROJECT Retreat Meadows
PROJECT DESCRIPTION Build 2 Story SFR 3183 Sq. Ft Lot 50
Detailed description of work to
be included on this permit only
NAME PRIMARY PHONE
Lennar Northwest Inc. 253-590-2215
PROPERTY OWNER MAILING ADDRESS E-MAIL
33455 6th Ave S.,Unit 1-B spencer.j.fitch@lennar.com
CITY STATE ZIP
Federal WayWA 98003
NAME PHONE
Lennar Northwest Inc. 253-590-2215
MAILING ADDRESS E-MAIL
CONTRACTOR 33455 6th Ave S.,Unit 1-B • spencer.j.fitch@lennar.com
CITY STATE ZIP FAX
Federal Way WA 98003
WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE S
CC LENNNANI893QG -II/ 7 2019
NAME Spencer Fitch PRIMARY PHO E
15
APPLICANT MAILING ADDRESS E-MAIL
33455 6th Ave S.,Unit 1-B spencer.i.fitch(Flennar.com
CITY STATE ZIP FAX
Federal Way WA 98003
NAME PRIMARY PHONE
PROJECT CONTACT Spencer Fitch 253-590-2215
e individual to receive and MAILING ADDRESS E-MAIL
rr1,
1”` 33455 6th Ave S.,Unit 1-B spencer.j.frtch@lennar.com
lennar.rnm
respond to all correspondence
concerning this application) CITY STATE ZIP FAX
Federal Way WA 98003
NAME
PROJECT FINANCING Lennar Northwest Inc. 0 OWNER-FINANCED
When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE
(RCW 19.27.095) 33455 6th Ave S.,Unit 1-B Federal Way,WA 98003 253-590-2215
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in
the investigation and defense of such claim),which may be made by any person, including the undersigned, and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as a part of this application.
SIGNATURE: 5.'el2'frte--424' •4 DATE 2/8/18
PRINT NAME: Spencer Fitch
Bulletin#100—January 29,2016 Page 1 of 2 k:\Handouts\Pernut Application
Niko...,
VALUE OF MECHANICAL WORK
MECHANICAL PERMIT
$ 10,000.00
Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain.
AIR HANDLING UNITS 8 FANS 4 GAS PIPE OUTLETS OTHER(Describe)
AIR CONDITIONER 1 FIREPLACE INSERTS HOODS(commerciai)
BOILERS 1 FURNACES 1 HOT WATER TANKS(Gas)
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
1 DUCTING 4 GAS PIPING WOODSTOVES
) VALUE OF PLUMBING WORK
PLUMBING PERMIT $ 20,000.00
Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existinq fixtures to remain.
2 BATHTUBS or Tub/Shower Combo( 6 LAVS(Hand Sinks) 4 TOILETS WATER PIPING
1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe)
DRAINS 1 SHOWERS VACUUM BREAKERS
DRINKING FOUNTAINS 2 SINKS(Kitchen/Utility) WATER HEATERS(Electric)
2 HOSE BIBBS SUMPS 2 WASHING MACHINES 20 TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS
N/A Lakehaven Utility District $ N/A
EXISTING/PREVIOUS USE LOT SIZE(in Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM?
VacantR480 ❑Yes k No ❑Yes a No
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
3ASEMENT;; , gOt
�" I' '.2''''-A- #' 1,-r
FIRST FLOOR(or Mobile Home) 0 1738 1738
SECOND FLOOR „ • 0 1445 1445 1
COVERED ENTRY 0 19 19
i
DECK a, x �t 4' a
GARAGE M CARPORT ❑ 0 583 583
OR � �THE (desc�) F-
EXISTING PROPOSED
Area Totals 3183 31OJ
ESTIMATED SELLING PRICE$ 350,000.00 # OF BEDROOMS 4
COMMERCIAL—NEW/ADDITION
AREA DESCRIPTION Area m Occupancy Group(s) Construction #of Additional Information
Square Feet Type Stories
. :, IW BUIf+I7lINGIre ��
, • ,"
ADDITION
COMMERCIAL—REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION Area in Occupancy Group(s) Construction #of Additional Information
Square Feet Type Stories
TOTAL BUILDING n y r :,t
TENANT AREA ONLY
.PROJECT AREA.ONLY
Bulletin#100—January 29,2016 Page 2 of 2 k:\I-Iandouts\Permit Application
4 ,
Lakehaven -n
WATER&SEWER DISTRICT
swim
Lakehaven Water&Sewer District - Development Engineering Section
31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: I Building Permit-SFR(56) El Building Permit-MFR 0 Building Permit-Other
❑ Subdivision 0 Short Subdivision 0 Binding Site Plan
❑ Rezone 0 Boundary Line Adjustment
❑ Other(specify/describe)
Tax Parcel Number(s): TBD(orig. 3021049020. 3021049021. 3021049058, 30210490821 Site Address: Multiple
Ex. Bldg. Area to Remain: N/A sf New Bldg.Area Proposed: 3.500-4.500 sf Lakehaven GIS Grid: H-13
Applicant's Name: Lennar NW. Inc.
SEWER SYSTEM INFORMATION
1. ® Sewer service can be provided by service connections to new 2". 3" or 6" diameter sewer mains that are approximately
5+/- to 150+/-feet from the plat lots and the sewer system has the capacity to serve the proposed land use.
2. ❑ Sewer service for the site will require an improvement to Lakehaven's sanitary sewer system of:
❑ a. feet of "diameter sewer main or trunk to reach the site; and/or
❑ b. The construction of a sanitary sewer collection system on the site; and/or
❑ c. A major portion of Lakehaven's comprehensive wastewater system plan would need to be implemented and/or
constructed; and/or
❑ d. Other(describe):
3. ® a. The existing sewer system Is In conformance with Lakehaven's Comprehensive Wastewater System Plan.
O b. The existing sewer system is not in conformance with Lakehaven's Comprehensive Wastewater System Plan and an
Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits.
4. ® a. The proposed site land use is within the corporate limits of Lakehaven Water&Sewer District,or has been granted
Boundary Review Board approval for extension of sewer service outside of Lakehaven's sewer service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service,
5. Sewer service is subject to:
® a. Payment of connection charges (to be determined by Lakehaven);
CI b. Proof or reservation of easement(s) as required by Lakehaven;
• c. Other: Sewer Service Connection Permit(1/Ion reauired. Private Grinder PumD Aareement(1/lot) reauired.
Comments/special conditions: Associated Developer Extension Agreement project(#6314010) must be accepted by Lakehaven. prior
to activating service connections.
I hereby certify that the above sewer system information Is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR
/
Signature: ...�... Date: 3/
� 1151
PERMIT#: 19-101174-00-V RECEIVED
ADDRESS: 35829 1ST Place SW MAR 13 2019
PROJECT: New Construction , Q
" vl Abows LOT 50 CITY OF FEDERAL WAY
DATE: 03/12/2019 COMMUNITY DEVELOPMEN1
Retreat Meadows swr.docx(Form Update 1/3/17) Page 1 of 2
... IP
% •
a
•
sW 35610 ST .
.: ..*■ter.■ i
,,,,,up. W`
1 :/g)
S ■ty
NI E :4
.q
h
4
302104902
3021049036
11W41111*
..
- 4b:
..
r
t
1
10 56
I.
3021049125 11
12 . 3021049118
54535 _
3021049164 13 .
•
14 ►
.4,■ • ., Nae• • SW358THST
lin I
43 46 1 3021049156
3021049121 16
17 42 51 B i
41 50 3
3517.4.4.1
8�H P q
rr••• 40 49 4 3021049004
18 •� 39 46 le
•4 n
19 - s
e
..it
4 35 34
3021049126 20 . p I 4 3021049157
. 11111
MEEN►S359TH Pt ,f
. an
r 3021049092
C
3021049013 ■■■■u■■r■r■r■■■' ■■. .06 N
'M
hal Lakehaven Water and Sewer
SewerGerbficate of Availability
District neither warrants nor guarantees Piet of Retreatment Meadows
the accuracy of any Tacitly information 0 100 400
provided.Facility locations and conditions
are subject to fieldveryiaation.
Feet 3/5/2018 8IA
Retreat Meadows swr.docx (Form Update 1/3/17) Page 2 of 2
4111 .
•
LAKEHAVEN UTILITY DISTRICT
Hydraulic Model Fire Flow Estimate
Request/Reporting Form
Requested By: Date:
Bert Ross 03/3/98
Hydrant Location: Off site of Illahee Jr HS
1/4 Section: H-14
Intersection: Approx. S 360th and 1 Ave S
Add. Description:
HL'SUL1S ZSI: L)AY'6: .._.__ WUUSL KLN 40.:-- __-- .-
John. Bowman 03/05/98 95LUDSFF.INP FF#57
Condition Pressure (psi) Flow (gpm)
Static 100 0
Fire Flow 20 4800
NOTE:
This fire flow rate will cause velocities in excess of 10 f/s
within the water distribution system. A fire flow rate less
than 2700 gpm will maintain flow velocities below 10 f/s.
There is no guarantee that the Hydraulic Model results will
represent actual system performance. Model results depict
the theoretical performance of the system under high demand
conditions. Field measurements should always be obtained for
design purposes.
V‘- i`\
' 114
i''-
4
i
Lakehaven
WATER&SEWER DISTRICT
Lakehaven Water &Sewer District - Development Engineering Section
31623 - 1st Ave S * PO Box 4249 * Federal Way, WA 98063-4249
Telephone: 253-945-1581 or 253-945-1580 * Email: DE@Lakehaven.org
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, water service based upon capacity &/or supply limitations
in Lakehaven's or Other Purveyor's system facilities.
Proposed Land Use: ® Building Permit-SFR(56) 0 Building Permit-MFR 0 Building Permit-Other
❑ Subdivision 0 Short Subdivision 0 Binding Site Plan
❑ Rezone 0 Boundary Line Adjustment
❑ Other(specify/describe)
Tax Parcel Number(s): TBD (orig. 3021049020. 3021049021. 3021049058. 3021049082) Site Address: Multiple
Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: 3,500-4.500 sf Lakehaven GIS Grid: H-13
Applicant's Name: Lennar NW. Inc.
WATER SYSTEM INFORMATION
1. ® Water service can be provided by service connections to a new 8" diameter water main that is approximately 10+/- to
185+/-feet from the plat lots.
2. 0 Water service for the site will require an improvement to Lakehaven's water distribution system of:
❑ a. feet of "diameter water main to reach the site; and/or
❑ b. The construction of a water distribution system on the site; and/or
❑ c. A major portion of Lakehaven's comprehensive water system plan would need to be implemented and/or
constructed; and/or
❑ d. Other(describe): .
3. ® a. The existing water system is in conformance with Lakehaven's Comprehensive Water System Plan.
❑ b. The existing water system is not in conformance with Lakehaven's Comprehensive Water System Plan and an
Amendment to this Plan will be required.This may cause a delay in issuance of land use approvals or permits.
4. ® a. The subject property is within the corporate limits of Lakehaven Water&Sewer District,or has been granted
Boundary Review Board approval for extension of water service outside of Lakehaven's water service area.
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
5. Water service is subject to:
ISI a. Payment of connection charges (to be determined by Lakehaven);
® b. Proof or reservation of easement(s)as required by Lakehaven;
❑ c. Other: Water Service Connection applications(1/lot) required.
Comments/special conditions: Associated Developer Extension Agreement project(#6314010) must be accepted by Lakehaven. prior
to activating service connections. Service pressure Greater than 80 psi indicated for some plat lots. some Pressure Reducing Valves
indicated. contact local building official for requirements&/or additional information.
The nearest fire hydrants are approximately 5+/- to 375+/-feet from the plat lots (as shown on map on the back of this page).
System hydraulic model results (FF #57, copy attached), at no less than 20 psi, indicate that Lakehaven's standard maximum
allowable liquid velocity of 10 ft/s is exceeded at a fire flow rate above 2.700 GPM (approximate). This flow figure depicts the
theoretical performance of the water distribution system under high demand conditions. Fire flow rates greater than this may be
accommodated through water distribution system improvements,contact Lakehaven for additional information.
450 Pressure Zone Est. Meter Elevation(s)-GIS: High 276+/-, Low 248+/- Est. Pressure Range at Meter(s) (psi): 73-87
I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN/ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR
Signature: G 044.— Date: �/457/�
Retreat Meadows wtr.docx (Form Update 1/3/17) Page 1 of 2
�•
•
41.
365111
66 ST *
1.3 - 12■
SW �ti P. .r '1 "in -ox x "DI
r 'PI'.�— _.
K'_f~ II 1 N Hyd r.
Hyd r. 2 "r
3 z�
4 ro
302104902 7b 1 k 4 3021049036
-,___J NO
9 Ars
8 - Hyd r.
NI
to ri,A5IL
3021049125 11 4
s
H12 eb 302104911B
3021049164 13
14 _ 'fi•t 352I
sw , :TH ST
15 I
43 1. 46 47 3021049156
3021049121 16 1
17 42 51 B
I 4111211 .
50
.i 358TH PL "* '
40 49 3021049004
n 3 39 Mal
19 MEI
_ 1:1 in'35 34
3021049126 20 3021049157
Ell trilgriff/ • "at 41111.1
* �rR
22
24 25 2, 28 29 30 3021049092
23
! �_l��
3021049013 g•DI 9�OtoTf 9t
• 1611:
MOTE: Lakehaven Wrier and Sewer
Water Certificate ofAvaiiabdity
District nether warrants nor guarantees plat of Retreatment Meadows
the accuracy of any facility information U WO 40n
provided.Facility locations and conditions I
are subject to fieldvereication.
Fed 3/512018 BIA
Retreat Meadows wtr,docx (Form Update 1/3/17) Page 2 of 2
AFTER RECORDING RETURN TO:
City of Federal Way
33325 8th Avenue South
Federal Way, WA 98003-6325
ATTN: Permit Center
RESTRICTIVE COVENANT
Grantor(s): Lennar Northwest,Inc
Grantee(s): CITY OF FEDERAL WAY, a Washington municipal corporation
Assessor's Tax Parcel ID#: 724290 0500
This Restrictive Covenant("Covenant") is made by Lennar Northwest,Inc.
("Grantors")for the purposes of recording a restrictive covenant covering certain real property commonly
known as 35829 1St P1 SW,Federal Way, Washington,98023, and legally described as follows:
Legal Description:
Lot 0050,Retreat Meadows, according to the plat thereof,recorded under Auditor's File No.
20180625000948, records of King County, Washington
A. Grantor has made application to the City of Federal Way under City of Federal Way Permit No.
19 101174 000 00 -SF("Permit")for the purposes of constructing a new single family dwelling
unit,which dwelling unit appears to have components of an Accessory Dwelling Unit("ADU")
including separate living, sleeping, sanitation and cooking facilities. The single-family residence
is not an ADU as it does not have permanent provision for cooking and it is not intended as an
ADU.
B. Federal Way Revised Code("FWRC") 19.05.040 defines a"dwelling unit"as a complete,
independent living facility exclusively for one family. Per FWRC 19.200.010, only one dwelling
unit may be located on the subject property.
NOW, THEREFORE, Grantor agrees as follows:
1. Use of Single Family Dwelling. Grantor agrees that the Property shall at all times be
used exclusively as one single family dwelling unit and the single family dwelling shall not be converted
into an ADU without City approval. Per FWRC 19.05.010,an ADU is defined as a structure accessory to
the main dwelling unit, providing complete, independent living facilities exclusively for one single
housekeeping unit,including permanent provisions for living, sleeping,cooking, and sanitation. This
Covenant shall not prohibit the Grantor from applying for a permit to establish an ADU.
2. Successors and Assigns. This Covenant shall be binding upon and shall inure to the
benefit of Grantor's successors in interest,heirs, grantees or assigns.
[Signature Page Follows]
DATED this 2a-1t• day of Tk1 1 , 2019.
City of Federal Way
By: 4
B ian Davis
Director of Community Development
Grantori /
Af/ i • e
By: LehvIGtP• Nor`VVWes+, the.
William Salvesen Company
Vice President
Property Owners
Lennar Northwest,Inc.
33455 6th Ave S#1-B
Federal Way, WA 98003
(253)590-2211
STATE OF WASHINGTON )
) ss.
COUNTY OF 1<;,,xj )
On this day personally appeared before me, W► I I 4.,..,,‘w‘ S q t v c.s er. ,
to me known to be the individuals described in and who executed the foregoing instrument, and
on oath swore that they executed the foregoing instrument as their free and voluntary act and
deed for the uses and purposes therein mentioned.
GIVEN my hand and official seal this 2A-1- day of d L.,17 , 2019.
Notary's signature
0%uilnutu,,,
`,`
5cp
r ,' Notary's printed name 0-o s ee g tr-e2k v�o•0Ol
Notary Public in and for the State of Washington.
n9 INA.*Ast �°, My commission expires Ock/0 I /101-1
%o'',OF.... ti
��:-a��T�- ���o l i�7�-����=�
���� : �� �r .�s-� L S�
�('Ow��� ���� �C�S t�-�
m 5�
w � T- r
b� Q � � N �
t o
o � � � � Z N �n
I
�
� W a O � � Ti
.. � �C/7 � � � U Z �
Y� N � pr� l� pp Z O Z
;W ��� `no o � J
� � � M N U O �
�N � N d
p � � a W
o � v� � � � w �
� g p� � J J � Z
m w ��� II w � � O I
W F- � (n �/� �
vi
J � w ~ W ��J N � a � Z Z �
> N � c.� i? Q rn� cn J w � II II a O
m � � � � ��o � �o � J � ao � �
� ``' � � J oMw o oo� aQ � � � W i m
F--� o3 �
� � MS �d1SLN � � N �= a � o �
w o
� m �`� � z z
� o ZQ J �
� - _ - � Q � w
. d ,:: Q I— � U
�
--SS—�I16'M341 W Z m Q
3 ,00'£6 3.6t,LZ.ION � Q � �
,6--- -- —
m o w... w W �
�o �\ 25� � � �� �
� —— Q a � W
� � �_3�� N w � �
� O� p ..
z r�'� �
p�� Q < � �
J.bM3Alba a� W �'� . F-
31321�N0� J < +-
,8l _ � � a
� w �► m
9 �Q j� �� �� o��� � �
W r
I ��-� f' � u.
� a 3�eav� Z w w � ti�. �jr V �'_' M
o �oQ
i 8�8 � � � z �o� ' a � J- w ? � o
o I � oo J� V m ~ �
� � � �' I g � } Q � _ � Ln
`° � W No� o a m � � �
� �
� � � � °� � � � o � N
^ � � �yo/�/ �z o �Q� � � � a
� O N �" �wp Q p Q O I . N O � I_ N
I = c/!
� I— �� � �N� I � -� O
I
z Qa J wa�o � � � _ �' W
i � o- � _ � z a �
I �¢ oz � OZ3
� X � I' Z W M
i .o� N � � Qa �n
I : _ � N
�s - - - -� �. Z H W v
�� � � �
z z ,.,, o. — .L Z (C 0
�� � a W � W
m g 25� . . � � J � LL
` M
�� � M
cn o LL
xZ
'-'-'o
U
N
O
n
N �
H N
F�- Z U
S
N� O ZN
m� � S
� a�
� X o�
Z a Zw
w N '1 g� �
Q N) N N -p �
9SZ o c� oo �� �
pooc� � ?5 0
,._.,...... _ z rn c� ao w w
N Q I I Z �
,00'£9 3„til,LZ.ION r � `n `n �'z a
� i�i� W� M
e- fV Z N N J� �
00 W > �
� r- Y �� UN �
� �
u�
O "
J
0
(pN �"''s �
�j a�, y
�- z � J �� ��� z o
w
O�-� w � z � � Zw�� Q ,�� ' Z o
�- � a� o z � � ��ago'� _.(� � J 2 �
� Q� } N� J �/ �
Q �wN -�0� � 1- �� SO�� O � � , J"` v°
wZ ? � a >�� W r�-cwn �=c" = �� d►�� coNS �
o � � =�p �� o � ��w � c�o 0
JQ� �O�W >- � �� -�Omw� � d
(/) � `L � cn � � O p �
owpcn � w cn�w cnz�NUm o �
OL`p ¢�� aw0? ��� O��w�= o o N c°� � �
wN� z�wJC`� JU I YW � ZF- � � .- � Z y
� ��Q� ]O Q Q � �O w �� Z I- N o >
� 2 0
� Y�I� � � �OF-QmZ� Qtn� 0�� ��p W� m� i
� R Q 2' Z�O Q �� N �Q w ��-- � w =� Z V I; � N N � �
=� 0 � Qp W� W O�m JtnO � F- J � �m; � �m m � N
� � o�o� � c.� w a- J ¢�� � � Q �w $ t� N
(%jN�� Q o
�J� � W �' � � �Q ��jJ � �W� �" � �i v j � o�o
W Z W I OW QO � �-- W Z W2 ZO= � Z � O ,4, 3 Y Q �
�� JCDI- ml..� QC�Nm QJ(n - C�F- OQ z2 Hq p b' /
O , O O U � O a
Z � N M �
}, r
����� ' '